• Title/Summary/Keyword: color sensitivity

Search Result 316, Processing Time 0.03 seconds

Proposal on the Severity Scoring System of Rhinitis ; Comparison, Analysis and Establishment (비염의 평가 방법에 대한 제언 ; 비교 분석 및 설립)

  • Hwang Sun-Yi;Hwang Min-Bo;Lim Jin-Ho;Jee Seon-Young;Kim Sang-Chan;Baek Jung-Han;Lee Sang-Gon
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.1
    • /
    • pp.235-244
    • /
    • 2006
  • There is much confusion in the field of Rhinitis regarding how to best measure disease severity objectively, Therefore, we aimed to establish a new adequate scoring system for Rhinitis, that should be based on comparison analysis of various scoring systems. We report as follows. We researched for data relating to severity scoring systems for rhinitis in Entrez PubMed from 1995 to 2005 and in Kiss Kstudy. Results and Conclusions: Properties of severity scoring systems were validity, sensitivity of change and ease of use. The essential items of severity scoring systems were subjective symptoms. The criterion of severity were divided into subjective symptoms and complication and Quality of Life. Intensity items are nasal obstruction, rhinorrhea, sneezing, itching, Postnasal drip, nasal mucosa swelling, nasal mucosa color, complication. Subjective symptoms is difficulty of Life. The significant items of severity scoring system are nasal symptoms. The whole score does with the maximum 30 scores. As it were, we assumed nasal symptoms accounted for around 80% of each total score, with complication and difficulty of Life representing 20%.

Development of PKNU3: A small-format, multi-spectral, aerial photographic system

  • Lee Eun-Khung;Choi Chul-Uong;Suh Yong-Cheol
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.5
    • /
    • pp.337-351
    • /
    • 2004
  • Our laboratory originally developed the compact, multi-spectral, automatic aerial photographic system PKNU3 to allow greater flexibility in geological and environmental data collection. We are currently developing the PKNU3 system, which consists of a color-infrared spectral camera capable of simultaneous photography in the visible and near-infrared bands; a thermal infrared camera; two computers, each with an 80-gigabyte memory capacity for storing images; an MPEG board that can compress and transfer data to the computers in real-time; and the capability of using a helicopter platform. Before actual aerial photographic testing of the PKNU3, we experimented with each sensor. We analyzed the lens distortion, the sensitivity of the CCD in each band, and the thermal response of the thermal infrared sensor before the aerial photographing. As of September 2004, the PKNU3 development schedule has reached the second phase of testing. As the result of two aerial photographic tests, R, G, B and IR images were taken simultaneously; and images with an overlap rate of 70% using the automatic 1-s interval data recording time could be obtained by PKNU3. Further study is warranted to enhance the system with the addition of gyroscopic and IMU units. We evaluated the PKNU 3 system as a method of environmental remote sensing by comparing each chlorophyll image derived from PKNU 3 photographs. This appraisement was backed up with existing study that resulted in a modest improvement in the linear fit between the measures of chlorophyll and the RVI, NDVI and SAVI images stem from photographs taken by Duncantech MS 3100 which has same spectral configuration with MS 4000 used in PKNU3 system.

Consumer Perception and Evaluation of Cynanchi Atrati Radix Fermented Oriental Cosmetics for Skin Whitening (피부 미백용 백미발효 한방 화장품에 대한 소비자 인식과 평가)

  • Son, Chang-gue;Jang, Eun-su;Lee, Sam-keun;Barng, Kee-jung
    • Journal of Fashion Business
    • /
    • v.23 no.5
    • /
    • pp.137-150
    • /
    • 2019
  • This study aimed to provide consumer perception and evaluation of natural Cynanchi Atrium Fermented Original Cosmetics for Skin Whitening that can improve skin by using oriental medicinal ingredients. The product was applied three times a day for two weeks by a total of 60 users who agreed to participate in a clinical trial assessing the usability and skin sensitivity to extracts that had already completed component safety testing. This study subjects reported which images were most reminiscent of Korea. They preferred products that bore Korean images because they felt trust and recognized that the quality of the cosmetics was excellent. The responses also showed that many consumers were willing to buy a product, even though it was luxurious, elegant, and expensive. The cognitive evaluation of Original Cosmetics was high and showed that the quality was likely to be good. The usability and CMF(Color, Material, Finishing) evaluation of Original Cosmetics showed good product the product is long-lasting and tightened and moisturized skin naturally. They are think about that this product it has moisturizing effects and good application for use, so it is light and soft to use. And had a whitening effect. It was intended to assist in the development of products that meet consumers' desires and expectations for safe, healthy, and beautiful skin by developing a skin whitening Original Cosmetics prototype that can inhibit the production of melanin and tyrosinase activity safely and effectively.

A LAMP-SNP Assay Detecting C580Y Mutation in Pfkelch13 Gene from Clinically Dried Blood Spot Samples

  • Khammanee, Thunchanok;Sawangjaroen, Nongyao;Buncherd, Hansuk;Tun, Aung Win;Thanapongpichat, Supinya
    • Parasites, Hosts and Diseases
    • /
    • v.59 no.1
    • /
    • pp.15-22
    • /
    • 2021
  • Artemisinin resistance (ART) has been confirmed in Greater Mekong Sub-region countries. Currently, C580Y mutation on Pfkelch13 gene is known as the molecular marker for the detection of ART. Rapid and accurate detection of ART in field study is essential to guide malaria containment and elimination interventions. A simple method for collection of malaria-infected blood is to spot the blood on filter paper and is fast and easy for transportation and storage in the field study. This study aims to evaluate LAMP-SNP assay for C580Y mutation detection by introducing an extra mismatched nucleotide at the 3' end of the FIP primer. The LAMP-SNP assay was performed in a water bath held at a temperature of 56℃ for 45 min. LAMP-SNP products were interpreted by both gel-electrophoresis and HNB-visualized changes in color. The method was then tested with 120 P. falciparum DNA from dried blood spot samples. In comparing the LAMP-SNP assay results with those from DNA sequencing of the clinical samples, the 2 results fully agreed to detect C580Y. The sensitivity and specificity of the LAMP-SNP assay showed 100%. There were no cross-reactions with other Plasmodium species and other Pfkelch13 mutations. The LAMP-SNP assay performed in this study was rapid, reliable, and useful in detecting artemisinin resistance in the field study.

Gold Nanoparticle and Polymerase Chain Reaction (PCR)-Based Colorimetric Assay for the Identification of Campylobacter spp. in Chicken Carcass

  • Seung-Hwan Hong;Kun-Ho Seo;Sung Ho Yoon;Soo-Ki Kim;Jungwhan Chon
    • Food Science of Animal Resources
    • /
    • v.43 no.1
    • /
    • pp.73-84
    • /
    • 2023
  • Campylobacteriosis is a common cause of gastrointestinal disease. In this study, we suggest a general strategy of applying gold nanoparticles (AuNPs) in colorimetric biosensors to detect Campylobacter in chicken carcass. Polymerase chain reaction (PCR) was utilized for the amplification of the target genes, and the thiolated PCR products were collected. Following the blending of colloid AuNPs with PCR products, the thiol bound to the surface of AuNPs, forming AuNP-PCR products. The PCR products had a sufficient negative charge, which enabled AuNPs to maintain a dispersed formation under electrostatic repulsion. This platform presented a color change as AuNPs aggregate. It did not need additional time and optimization of pH for PCR amplicons to adhere to the AuNPs. The specificity of AuNPs of modified primer pairs for mapA from Campylobacter jejuni and ceuE from Campylobacter coli was activated perfectly (C. jejuni, p-value: 0.0085; C. coli, p-value: 0.0239) when compared to Salmonella Enteritidis and Escherichia coli as non-Campylobacter species. Likewise, C. jejuni was successfully detected from artificially contaminated chicken carcass samples. According to the sensitivity test, at least 15 ng/μL of Campylobacter PCR products or 1×103 CFU/mL of cells in the broth was needed for the detection using the optical method.

Effect of medium or high concentrations of in-office dental bleaching gel on the human pulp response in the mandibular incisors

  • Douglas Augusto Roderjan;Rodrigo Stanislawczuk;Diana Gabriela Soares;Carlos Alberto de Souza Costa;Michael Willian Favoreto;Alessandra Reis;Alessandro D. Loguercio
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.2
    • /
    • pp.12.1-12.11
    • /
    • 2023
  • Objectives: The present study evaluated the pulp response of human mandibular incisors subjected to in-office dental bleaching using gels with medium or high concentrations of hydrogen peroxide (HP). Materials and Methods: The following groups were compared: 35% HP (HP35; n = 5) or 20% HP (HP20; n = 4). In the control group (CONT; n = 2), no dental bleaching was performed. The color change (CC) was registered at baseline and after 2 days using the Vita Classical shade guide. Tooth sensitivity (TS) was also recorded for 2 days post-bleaching. The teeth were extracted 2 days after the clinical procedure and subjected to histological analysis. The CC and overall scores for histological evaluation were evaluated by the Kruskal-Wallis and Mann-Whitney tests. The percentage of patients with TS was evaluated by the Fisher exact test (α = 0.05). Results: The CC and TS of the HP35 group were significantly higher than those of the CONT group (p < 0.05) and the HP20 group showed an intermediate response, without significant differences from either the HP35 or CONT group (p > 0.05). In both experimental groups, the coronal pulp tissue exhibited partial necrosis associated with tertiary dentin deposition. Overall, the subjacent pulp tissue exhibited a mild inflammatory response. Conclusions: In-office bleaching therapies using bleaching gels with 20% or 35% HP caused similar pulp damage to the mandibular incisors, characterized by partial necrosis, tertiary dentin deposition, and mild inflammation.

Efficient Sign Language Recognition and Classification Using African Buffalo Optimization Using Support Vector Machine System

  • Karthikeyan M. P.;Vu Cao Lam;Dac-Nhuong Le
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.6
    • /
    • pp.8-16
    • /
    • 2024
  • Communication with the deaf has always been crucial. Deaf and hard-of-hearing persons can now express their thoughts and opinions to teachers through sign language, which has become a universal language and a very effective tool. This helps to improve their education. This facilitates and simplifies the referral procedure between them and the teachers. There are various bodily movements used in sign language, including those of arms, legs, and face. Pure expressiveness, proximity, and shared interests are examples of nonverbal physical communication that is distinct from gestures that convey a particular message. The meanings of gestures vary depending on your social or cultural background and are quite unique. Sign language prediction recognition is a highly popular and Research is ongoing in this area, and the SVM has shown value. Research in a number of fields where SVMs struggle has encouraged the development of numerous applications, such as SVM for enormous data sets, SVM for multi-classification, and SVM for unbalanced data sets.Without a precise diagnosis of the signs, right control measures cannot be applied when they are needed. One of the methods that is frequently utilized for the identification and categorization of sign languages is image processing. African Buffalo Optimization using Support Vector Machine (ABO+SVM) classification technology is used in this work to help identify and categorize peoples' sign languages. Segmentation by K-means clustering is used to first identify the sign region, after which color and texture features are extracted. The accuracy, sensitivity, Precision, specificity, and F1-score of the proposed system African Buffalo Optimization using Support Vector Machine (ABOSVM) are validated against the existing classifiers SVM, CNN, and PSO+ANN.

Stiffness of the Central Corpus Cavernosum on Shear-Wave Elastography Is Inversely Correlated with the Penile Rigidity Score in Patients with Erectile Dysfunction

  • Joo Yong Lee;Dae Chul Jung;Seungsoo Lee;Nam Gyu Kang;Young Taik Oh;Kyunghwa Han
    • The World Journal of Men's Health
    • /
    • v.39 no.1
    • /
    • pp.123-130
    • /
    • 2021
  • Purpose: To perform real-time quantitative measurements of penile rigidity for patients with erectile dysfunction (ED) using shear-wave elastography (SWE). Materials and Methods: A total of 92 patients with clinically diagnosed ED filled out an abridged five-item version of the International Index of Erectile Function (IIEF-5) questionnaire and underwent SWE as well as penile color Doppler ultrasound (CDUS) after intracavernosal injection for penile erection. Elasticity measurements were repeated on two sites of the corpus cavernosum (central and peripheral elasticity of corpus cavernosum [ECC]) and the glans penis during the erection phase. Correlations between penile elasticity and rigidity scores or IIEF-5 were evaluated statistically. Penile elasticity was also compared with the ED types based on CDUS. Results: The mean age of all patients was 53.5±13.4 years, and the mean IIEF-5 score was 9.78±5.01. The rigidity score and central ECC value demonstrated a significant correlation (r=-0.272; 95% confidence interval: -0.464 to -0.056; p=0.015). The IIEF-5 score was not significantly correlated with penile elasticity. Vascular ED patients showed significantly higher central ECC values than nonvascular ED patients (p<0.001). At a cut-off value of 8.05 kPa, the central ECC had a specificity of 41.5%, a sensitivity of 84.6%, and an area under the ROC curve of 0.720 with a standard error of 0.059 (p=0.019) for predicting vascular ED. Conclusions: Quantitatively measuring Young's modulus of the corpus cavernosum using SWE could be an objective technique for assessing penile erectile rigidity and the vascular subtype in patients with ED.

Hue Shift Model and Hue Correction in High Luminance Display (고휘도 디스플레이의 색상이동모델과 색 보정)

  • Lee, Tae-Hyoung;Kwon, Oh-Seol;Park, Tae-Yong;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.4 s.316
    • /
    • pp.60-69
    • /
    • 2007
  • The human eye usually experiences a loss of color sensitivity when it is subjected to high levels of luminance, and perceives a discrepancy in color between high and normal-luminance displays, generally known as a hue shift. Accordingly, this paper models the hue-shift phenomenon and proposes a hue-correction method to provide perceptual matching between high and normal-luminance displays. The value of hue-shift is determined by perceived hue matching experiments. At first the phenomenon is observed at three lightness levels, that is, the ratio of luminance is the same between high and normal-luminance display when the perceived hue matching experiments we performed. To quantify the hue-shift phenomenon for the whole hue angle, color patches with the same lightness are first created and equally spaced inside the hue angle. These patches are then displayed one-by-one on both displays with the ratio of luminance between two displays. Next, the hue value for each patch appearing on the high-luminance display is adjusted by observers until the perceived hue for the patches on both displays appears the same visually. After obtaining the hue-shift values, these values are fit piecewise to allow shifted-hue amounts to be approximately determined for arbitrary hue values of pixels in a high-luminance display and then used for correction. Essentially, input RGB values of an image is converted to CIELAB values, and then, LCh (lightness, chroma, and hue) values are calculated to obtain the hue values for all the pixels. These hue values are shifted according to the amount calculated by the functions of the hue-shift model. Finally, the corrected CIELAB values are calculated from corrected hue values, after that, output RGB values for all pixels are estimated. For evaluation, an observer's preference test was performed with hue-shift results and Almost observers conclude that the images from hue-shift model were visually matched with images on normal luminance display.

The Etiologic Diseases and Diagnostic Usefulness of Color Doppler Ultrasonography in Children with Chronic Coughs (소아 만성 기침의 원인 질환과 컬러 도플러 초음파 검사의 진단적 유용성)

  • Park, Sun Young;Lee, Joon Sung
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.4
    • /
    • pp.489-497
    • /
    • 2002
  • Purpose : The objectives of this study were to investigate the causes of chronic cough and to establish the appropriate diagnostic approach to chronic cough in children. Methods : One hundred and thirty two cases of chronic cough were prospectively evaluated. They visitors to pediatric chronic cough clinics at Kang-nam saint Mary's Hospital of Catholic University from August 2000 to July 2001 for 12 months. Careful history taking by questionnaire, physical examination, radiologic studies of chest and sinus, hematologic and immunologic studies, allergic skin tests, and methacholine challenge tests were performed. Color doppler(CD) ultrasonography were performed and compared with simultaneous 24 Hr. esophageal pH monitoring to diagnose gastroesophageal reflux disease(GERD). Results : Age distributions were demonstrated that nine in infants, 82 in early childhood, 38 in late childhood, and three in adolescence. Common causes of chronic cough were bronchial asthma in 40 cases, chronic sinusitis in 22 cases, GERD in seven cases, bronchial asthma combined with sinusitis in 28 cases, bronchial asthma combined with GERD in 14 cases, psychogenic cough in two. cases, foreign body in one case, chronic bronchitis in one case, and bronchiolitis in one case. Comparing with 24 Hr. pH monitoring, sensitivity, specificity, positive predictive value and negative predictive values of CD ultrasonography were 88%, 69%, 85 %, and 73% respectively. Conclusion : The most common causes of chronic cough in children were bronchial asthma, sinusitis and GERD in order. We suggest that CD ultrasonography can be used as a good, convenient screening method for patients with suspected GERD in outpatient settings.