• Title/Summary/Keyword: color measuring

Search Result 502, Processing Time 0.026 seconds

Implementation of Intelligent Expert System for Color Measuring/Matching (칼라 매저링/매칭용 지능형 전문가 시스템의 구현)

  • An, Tae-Cheon;Jang, Gyeong-Won;O, Seong-Gwon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.7
    • /
    • pp.589-598
    • /
    • 2002
  • The color measuring/matching expert system is implemented with a new color measuring method that combines intelligent algorithms with image processing techniques. Color measuring part of the proposed system preprocesses the scanned original color input images to eliminate their distorted components by means of the image histogram technique of image pixels, and then extracts RGB(Red, Green, Blue)data among color information from preprocessed color input images. If the extracted RGB color data does not exist on the matching recipe databases, we can measure the colors for the user who want to implement the model that can search the rules for the color mixing information, using the intelligent modeling techniques such as fuzzy inference system and adaptive neuro-fuzzy inference system. Color matching part can easily choose images close to the original color for the user by comparing information of preprocessed color real input images with data-based measuring recipe information of the expert, from the viewpoint of the delta Eformula used in practical process.

COLOR DIFFERENCE OF THE DENTAL COMPOSITES MEASURED BY DIFFERENT COLOR MEASURING INSTRUMENTS (복합레진 색상의 측정 기기에 따른 차이)

  • Park, Su-Jung;Noh, Eun-Young;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.199-207
    • /
    • 2009
  • The objective of this study was to evaluate the effect of color measuring instrument by measuring the color of dental composite resins. Nine shade light cured composite resin disks were prepared (diameter : 15 mm, thickness : 4 mm). CIE $L^*a^*b^*$ color scale of each disk was measured with 3 different types of spectrophotometer [MiniScan XE plus (Model 4000S, Hunter Lab, USA), CM-3500d (Minolta, Japan) and Specbos 2100 Miniature VIS Reflection spectrometer (Serial No: 319416, JETI Technishe VIS Instrumentic GmbH. Germany)]. Miniscan XE Plus and CM-3500d using identical measuring geometry with different size of viewing aperture. But Specbos 2100 using different measuring geometry. Within the limitation of this study, there were color difference (${\Delta}E^*$) from 2.4 to 7.8 between Miniscan XE Plus and CM-3500d, but $L^*$, $a^*$, $b^*$ values showed the high correlation. However, there were great color difference (${\Delta}E^*$) in the extent of about 20 between instruments with the different measuring geometry. Therefore, color scale measured by color measuring instrument should be used as a relative value rather than an absolute value in the field of dentistry.

Distance Measuring Method for Motion Capture Animation (모션캡쳐 애니메이션을 위한 거리 측정방법)

  • Lee, Heei-Man;Seo, Jeong-Man;Jung, Suun-Key
    • The KIPS Transactions:PartB
    • /
    • v.9B no.1
    • /
    • pp.129-138
    • /
    • 2002
  • In this paper, a distance measuring algorithm for motion capture using color stereo camera is proposed. The color markers attached on articulations of an actor are captured by stereo color video cameras, and color region which has the same color of the marker's color in the captured images is separated from the other colors by finding dominant wavelength of colors. Color data in RGB (red, green, blue) color space is converted into CIE (Commission Internationale del'Eclairage) color space for the purpose of calculating wavelength. The dominant wavelength is selected from histogram of the neighbor wavelengths. The motion of the character in the cyber space is controlled by a program using the distance information of the moving markers.

Measuring of the Perceptibility and Acceptability in Various Color Quality Measures

  • Kim, A-Ri;Kim, Hong-Suk;Park, Seung-Ok
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.310-317
    • /
    • 2011
  • Perceptibility and acceptability are the most often used threshold units in the field of color science. The former refers to a just perceptible difference and the latter evokes a tolerable color difference. Such thresholds can be very significant to color quality control processes in the printing industry and should be defined in quality measure units. Optical density (OD) and color difference models are usually utilized as color quality measures and have been provided in a considerable number of commercial measuring devices such as spectrophotometers. However, their merits and traits are far less understood in the literature. The present study intends to evaluate performance of those color quality measures including the OD and widely known color difference models, e.g. ${\Delta}E{^*}_{ab}$, ${\Delta}E_{CMC(l:c)}$ and ${\Delta}E{^*}_{00}$. A set of psychophysical assessments were carried out in order to accumulate the perceptibility and acceptability thresholds data, and their central trend was compared with the color quality measure estimates.

A Study on the Compound Colors by Cross-Dyeing of Cotton/PET Union Fabrics (면(綿)/PET 교직물(交織物)의 Cross Dyeing에 의한 복합색상(複合色相) 연구(硏究))

  • Lee, Mi-Kyung
    • Journal of Fashion Business
    • /
    • v.11 no.1
    • /
    • pp.15-25
    • /
    • 2007
  • As a part of the study for the materials development of compound feelings, therefore, this study investigated into the effects of the colors of warp and weft on the overall colors of fabrics, along with the visual changes of colors by the measuring angle of both warp and weft, by means of cross-dyeing of cotton/PET union fabrics. First, the dyeing of cotton and PET fabrics individually with the same color, the dyeing of PET fabrics followed by that of cotton fabrics resulted in a small difference in color than the dyeing in the reversed order. Second, in the case of the dyeing of cotton/PET union fabrics with the color of one fiber fixed and that of the other in ten colors, the color of cotton fiber, which is warp, gave much influence. In addition, the color change was remarkable among complementary colors, while it was negligible among adjacent colors. Third, in the case of dyeing of cotton/PET union fabrics with the color of one fiber fixed and that of the other in ten colors, the results were different by the measuring angle. When PET was fixed in green and cotton was dyed in ten colors, color-deepening was observed by the inclination in the direction of warp and weft without the dominance over all colors like cotton. When cotton was dyed in red and PET in ten colors, the color of PET appeared dimly in the horizontal case by the direction of the light, and red appeared as inclined in the direction of warp and weft. This is because of the dominance of cotton color over the overall color, since the density of cotton fiber, the warp of union fabrics, is higher than that of PET, the weft. Thus, this is to be considered in the selection of the warp's color. In view of the above results, the color changes are outstanding when the color of warp dominates the overall color and when the colors of warp and weft are complementary, in comparison with the case when the colors are adjacent. The colors also change by the measuring angle.

POLYGONIOSCOPE a new instrument for fastest luminance, color and viewing angle measurement with highest accuracy

  • Laur, Juergen
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1370-1373
    • /
    • 2008
  • This paper introduces a novel display measuring instrument that allows accurate, spectro-radiometric measurement of the complete viewing cone while the measuring time is similar to that of a CCD camera with transform lens optics. Actually the new instrument, named POLYGONIOSCOPE, is orders of magnitude faster compared to a conventional spot spectrometer.

  • PDF

EVALUATION 01 OIL DISPERSION AGENT BY ASSESSMENT 01 COLOR STRENGTH 01 ORGANIC PIGMENT

  • H., Young-Chan;R., Seo-Joon;L., Dong-Wook;H., Soon-Taek
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.24 no.3
    • /
    • pp.73-80
    • /
    • 1998
  • This Study was performed to get the suitable oil dispersion agent by assessment of color strength of organic pigment in non-aqueous systems. Organic pigment is used as a color expression material with other body pigments in the make-up products. But occasionally aggregation or agglomeration occurs for the lack of affinity with medium, This function is the cause of disturbing homogeneous dispersion, and then bring about an instability of products. Our study, research of dispersion mechanism between the pigment and oil phase, has been executed to solve this problem, and find a oil dispersion agent having optimum dispersion condition. Generally dispersion is related to between the solid-liquid mutual properties and electrical phenomena associated with solid-liquid interface. This factor is determined to input energy, milling time, optical properties, particle size, rheological properties, etc. Ideal dispersion state is told that coloring primary solid particle is homogeneously dispersed in medium. Good dispersed colorants are strongly and clearly appeared. We are already known that the particle size of organic pigment, chemical properties and viscosity of medium, refractive index. Consequently We determine the affinity of medium and organic pigment by measuring of color strength in the same mechanical condition. UV-VISIBLE RECORDING SPECTRO PHOTOMETER is used for measuring apparatus. We can decided the dispersion level of oil dispersion agent by measuring absorbance of color strength in the visible range that diluted medium for colloid colorant particles.

  • PDF

A Study on the Measurement of Colour Fastness by CCM and New Fastness Formula (CCM을 이용한 변퇴색 견뢰도 등급의 판정 및 New Fastness Formula에 관한 연구)

  • Hong Min-Gi;Park Ju-Young;Park Yong-Mi;Koo Kang;Huh Man-Woo;Kim Sam-Soo
    • Textile Coloration and Finishing
    • /
    • v.18 no.2 s.87
    • /
    • pp.15-23
    • /
    • 2006
  • A new fastness formula based on CIEDE2000 color-difference formula is developed by B. Rigg and his coworkers. It is very simple to calculate fastness grade for color change than ISO 105-A05 fastness formula based on CIELAB color-difference formula. Sample pair sets which cover a wide range color space were accumulated from NCS(Natural Color System) color book. For those sample pair sets, visual measurement experiment and instrument measurement experiment of fastness grade were carried out and each performance of ISO 105-A02 fastness formula and newly developed fastness formula was compared through degree of agreement for visual measurement result. Newly developed fastness formula indicated improved performance for measuring fastness grade but current ISO fastness formula for assessing change in color, ISO 105-A05, was confirmed that it's performance is inadequate to measure fastness grade. Then fastness formulae were examined more closely according to particular color spaces and the correlation of hue, lightness and chrom for measuring fastness grade was also considered in this study.

Determination of Ammonia Nitrogen by Color Saturation Measurement System (채도측정시스템을 이용한 암모니아성 질소의 정량방법)

  • Lee, Hyeong-Choon
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.136-141
    • /
    • 2012
  • Objectives: The objective of this study was to investigate whether the ammonia nitrogen concentration of aqueous samples such as drinking water can be determined by measuring the saturation of the samples colored by indophenol method. Methods: A color saturation measurement system was constructed by connecting a notebook computer to an image acquisition device composed of a PC camera and a light source, and was then used to measure the saturation of samples colored by blue indophenol complex. Results: Between two available light sources, a fluorescent lamp was selected due to its demonstrating better linearity between color saturation and ammonia nitrogen concentration. Prediction by quadratic regression was more accurate than by linear regression, and prediction by quadratic regression in the concentration range of 0.1-1.0 $mg/l$ was more accurate than in the concentration range of 0.0-1.0 $mg/l$. Regression-based predictions over 0.25 $mg/l$, 0.55 $mg/l$ and 0.75 $mg/l$ concentrations were implemented both by spectrophotometric method and by measuring color saturation. In the case of 0.25 $mg/l$, the predicted concentration by spectrophotometric method was $0.256{\pm}0.0076\;mg/l$ and the predicted concentration by measuring color saturation was $0.246{\pm}0.0086\;mg/l$ (p=0.051). In the case of 0.55 $mg/l$, they were $0.561{\pm}0.0068\;mg/l$ and $0.564{\pm}0.0166\;mg/l$ (p=0.660). In the case of 0.75 $mg/l$, they were $0.755{\pm}0.0139\;mg/l$ and $0.762{\pm}0.0088\;mg/l$ (p=0.215). Conclusions: There were no statistically significant differences (p>0.05) between the data from the two methods in all three of the concentrations. Therefore, the color saturation measurement method proposed in this paper may be considered applicable for determining the ammonia nitrogen concentration of aqueous samples such as drinking water.

A study on the Modification of Fastness Formulae and the Measurement of Staining Fastness by CCM

  • Park, Ju-Young;Hong, Min-Gi;Lee, Nan-Hyeng;Kim, Sam-Soo;Hudson Samuel M.;Park, Sung-Su
    • Textile Coloration and Finishing
    • /
    • v.18 no.5 s.90
    • /
    • pp.80-87
    • /
    • 2006
  • A new fastness formula based on the CIEDE2000 color-difference formula was developed by B. Rigg and his coworkers. It is much simpler to calculate the staining fastness grade than the ISO 105-A04 fastness formula based on the CIELAB color-difference formula. Sample pair sets, which cover a wide color space range were accumulated from the NCS(Natural Color System) color book. for those sample pair sets, a visual measurement experiment and an instrumental measurement experiment of fastness grade were carried out. Each performance of the ISO 105-A43 fastness formula and newly developed fastness formula was compared through degree of agreement for visual measurement results. The newly developed fastness formula indicated improved performance for measuring fastness grade as it was confirmed that the performance of the current ISO fastness formula ISO 105-A04 for assessing staining, was inadequate for measuring fastness grade. Then the fastness formulae were examined more closely according to the particular color spaces and the correlation of hue, lightness and chroma for measuring staining fastness grade was also considered to recommend more improved fastness formula. By modifying the weighting functions of CIEDE2000, which is a basis of new fastness formula developed by B. Rigg, a modified fastness formula is proposed in this study.