• 제목/요약/키워드: color imaging

검색결과 405건 처리시간 0.032초

D.I.T.I.를 이용한 족삼리(ST36)자침이 안면부 절대온도변화에 미치는 영향 (Characteristics of Acupuncture at Chok-Samni(ST36) on Facial Thermographic Change of D.I.T.I.)

  • 조은희;박민철;최덕화
    • 동의생리병리학회지
    • /
    • 제17권6호
    • /
    • pp.1493-1499
    • /
    • 2003
  • This study was examined for effects of acupuncture of Chok-Samni(ST36) on the facial thermography in health subjects, The volunteers who participating in this study had taken rest for 15 mins in room temperature (19-21 ℃) before the examination and informed them what to prohibit smoking, drinking and administration of drug for the previous day, The thermography of face was taken using Digital Infrared Thermographic Imaging (D.I.T.I. : Dorex, DTI-16UT1, U.S.A.) by time interval of 35 minutes at 15 min before and 20 min after acupuncture stimulation. Thermal temperature of Yangbaek(GB14), Myon-koryo(ST3) and Chichang(ST4) was measured and compared, The results showed that acupuncture of Chok-Samni(ST36) decreased the Absolute difference of temperature between Myon-koryo(ST3) and Chichang(ST4) (p<0,05, Data were represented mean±S,E.M.(n=33)), But, acupuncture of Chok-Samni(ST36) particularly decreased the absolute difference of temperature between Yangbaek(GB14) and Chichang(ST4) and particularly decreased the absolute difference of temperature between Vangbaek(GB14) and Myon-koryo(ST3) (p<0,05, Data were represented mean±S,E.M.(n=33)). Also, it was observed that acupuncture of Chok-Samni(ST36) decreased variety of the color tone of thermographic contour line and decreased thermal distribution. The results showed that acupuncture of Chok-5amni(ST36) significantly decreased the absolute difference of temperature of partial facial surface. Hereafter, study about if acupuncture of Chok-Samni(ST36) significantly decrease the absolute difference of temperature of all the areas of facial surface is requested. Also, continued study of effects of acupuncture of other meridian on the facial thermography is requested.

Endoscopic Fluorescence Angiography with Indocyanine Green : A Preclinical Study in the Swine

  • Cho, Won-Sang;Kim, Jeong Eun;Kim, Sae Hoon;Kim, Hee Chan;Kang, Uk;Lee, Dae-Sic
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권6호
    • /
    • pp.513-517
    • /
    • 2015
  • Objective : Microscopic indocyanine green (ICG) angiography is useful for identifying the completeness of aneurysm clipping and the preservation of parent arteries and small perforators. Neuroendoscopy is helpful for visualizing structures beyond the straight line of the microscopic view. We evaluated our prototype of endoscopic ICG fluorescence angiography in swine, which we developed in order to combine the merits of microscopic ICG angiography and endoscopy. Methods : Our endoscopic ICG system consists of a camera, a light source, a display and software. This system can simultaneously display real-time visible and near infrared fluorescence imaging on the same monitor. A commercially available endoscope was used, which was 4 mm in diameter and had an angle of $30^{\circ}$. A male crossbred swine was used. Results : Under general anesthesia, a small craniotomy was performed and the brain surface of the swine was exposed. ICG was injected via the ear vein with a bolus dose of 0.3 mg/kg. Visible and ICG fluorescence images of cortical vessels were simultaneously observed on the display monitor at high resolution. The real-time merging of the visible and fluorescent images corresponded well. Conclusion : Simultaneous visible color and ICG fluorescent imaging of the cortical vessels in the swine brain was satisfactory. Technical improvement and clinical implication are expected.

해안가 야간경관조명의 빛공해 평가 - 부산시를 중심으로 - (Light Pollution of Outdoor Lighting in Coastal Area - Focused on Busan City -)

  • 공효주;김정태
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.18-26
    • /
    • 2010
  • 도시공간의 안정과 쾌적함을 위하여 옥외조명은 우리 사회에서 필수적인 부분이 되었다. 그러나 옥외조명을 잘못 설치할 경우 조명에너지의 낭비뿐만 아니라 건축물 야간경관 훼손을 야기시킨다. 최근 야간 경관조명의 중요성이 부각되면서 지자체마다 야간경관 이미지 구축에 집중을 하고 있다. 그 중 해안가 주변의 옥외조명은 지역 내에 특화된 관광 상권을 구성하며 생동감 있는 도시 이미지를 부여하고 도시경쟁력을 강화 시킬 수 있다. 본 연구는 우리나라의 대표적 항구 도시인 부산의 해안가의 야간경관조명의 빛공해를 평가하는데 그 목적이 있다. 디지털 광학 계측기인 Radiant Imaging ProMetric-1400으로 광안리 해수욕장, 마린시티, 그리고 해운대 해수욕장 주변의 옥외조명을 측정하였다. 모든 옥외조명의 휘도는 국제조명위원회 권고기준과 비교했을 때 약 2~20배 정도 높게 나타났다. 주상복합 상부조명 및 해안에 면한 상가 저층부는 색채 및 휘도의 제한이 필요한 것으로 사료된다.

COMPUTATIONAL ANTHROPOMORPHIC PHANTOMS FOR RADIATION PROTECTION DOSIMETRY: EVOLUTION AND PROSPECTS

  • Lee, Choon-Sik;Lee, Jai-Ki
    • Nuclear Engineering and Technology
    • /
    • 제38권3호
    • /
    • pp.239-250
    • /
    • 2006
  • Computational anthropomorphic phantoms are computer models of human anatomy used in the calculation of radiation dose distribution in the human body upon exposure to a radiation source. Depending on the manner to represent human anatomy, they are categorized into two classes: stylized and tomographic phantoms. Stylized phantoms, which have mainly been developed at the Oak Ridge National Laboratory (ORNL), describe human anatomy by using simple mathematical equations of analytical geometry. Several improved stylized phantoms such as male and female adults, pediatric series, and enhanced organ models have been developed following the first hermaphrodite adult stylized phantom, Medical Internal Radiation Dose (MIRD)-5 phantom. Although stylized phantoms have significantly contributed to dosimetry calculation, they provide only approximations of the true anatomical features of the human body and the resulting organ dose distribution. An alternative class of computational phantom, the tomographic phantom, is based upon three-dimensional imaging techniques such as magnetic resonance (MR) imaging and computed tomography (CT). The tomographic phantoms represent the human anatomy with a large number of voxels that are assigned tissue type and organ identity. To date, a total of around 30 tomographic phantoms including male and female adults, pediatric phantoms, and even a pregnant female, have been developed and utilized for realistic radiation dosimetry calculation. They are based on MRI/CT images or sectional color photos from patients, volunteers or cadavers. Several investigators have compared tomographic phantoms with stylized phantoms, and demonstrated the superiority of tomographic phantoms in terms of realistic anatomy and dosimetry calculation. This paper summarizes the history and current status of both stylized and tomographic phantoms, including Korean computational phantoms. Advantages, limitations, and future prospects are also discussed.

악관절에 대한 자기 공명 영상의 연구 (A STUDY ON MAGNETIC RESONANCE IMAGING OF THE TEMPOROMANDIBULAR JOINT)

  • 김형식;김재덕
    • 치과방사선
    • /
    • 제20권2호
    • /
    • pp.187-198
    • /
    • 1990
  • Examinations of the temporomandibular joints were performed on a 1.5 Tesla magnetic resonance (MR) system. An MR surface receiver coil 3 inch in diameter was placed on plastic frame, the patient's head being placed in the frame so that the coil was pressed against the temporal region. In taking advantage of the magnetic resonance imaging that has been studied briskly till now, author obtained the images of parasagittal and paracoronal planes about the temporomandibular joint by using MPGR (Multi-Planar Gradient Recalled), GRASS (Gradient Recalled Acquisition in the Steady State), and CSMEMP (Contiguous Slice Multiple Echo, Multi-Planar), that differ from the Spin Echo pulse sequence which the previous authors used. Five subjects with no symptoms of temporomandibular joint pain and dysfunction were studied. The plane images obtained by these methods were compared with those by Spin Echo pulse sequence. The results were as follows: 1. The optimal repetition times (TR) and echo times (TE) for T.M.J. image were; a. 400 msec and 18 msec in PMGR pulse sequence. b. 40 msec and 12 msec in GRASS pulse sequence. c. 700 msec and 30 msec in CSMEMP pulse sequence. d. 500 msec and 20 msec in Spin Echo pulse sequence. 2. When the MPGR pulse sequence was using, T2-weighted image was obtained in very short time. On the image of the paracoronal plane by GRASS pulse sequence, meniscus showed the moderate signal intensity, and the meniscus and its anteromedial, posterolateral attachments were observed definitely with gray color. 4. The signal intensity of Spin Echo pulse sequence was equal to that of CSMEMP pulse sequence, but the image by CSMEMP pulse sequence showed relatively lower level in its resolution.

  • PDF

Progress report of the deep and wide-field imaging survey of nearby galaxies with KMTNet

  • Byeon, Woowon;Kim, Minjin;Sheen, Yun-Kyeong;Ho, Luis C.;Jeong, Hyunjin;Kim, Sang Chul;Lee, Joon Hyeop;Park, Byeong-Gon;Seon, Kwang-Il
    • 천문학회보
    • /
    • 제42권1호
    • /
    • pp.58.3-58.3
    • /
    • 2017
  • In a ${\Lambda}CDM$ universe, galaxies are believed to evolve by mergers and accretions. The debris resulting from such processes remains as diffuse, low-surface brightness structures, such as outer disks, stellar halos, and faint companions. These structures will give us fruitful insight into the recent mass assembly history of galaxies, but it is challenging to observe them due to their low surface brightness. In order to explore the structural properties of outskirts of nearby galaxies, we conduct deep wide-field imaging survey with KMTNet. Here we present a progress report of data reduction for the images of NGC 1291, a lenticular barred galaxy with outer rings. To achieve accurate flat fielding, we use dark sky flat and remove the sky gradient of each exposure with a polynomial fit. As a result, we are able to reach 1 sigma depth of ${\mu}_R{\sim}29.6\;mag\;arcsec^{-2}$. We expect to investigate the surface brightness profile of NGC 1291 in 1-D profile, and color-gradient in the outer part of the galaxy using the B- and R-band images.

  • PDF

High Efficiency AMOLED using Hybrid of Small Molecule and Polymer Materials Patterned by Laser Transfer

  • Chin, Byung-Doo;Suh, Min-Chul;Kim, Mu-Hyun;Kang, Tae-Min;Yang, Nam-Choul;Song, Myung-Won;Lee, Seong-Taek;Kwon, Jang-Hyuk;Chung, Ho-Kyoon;Wolk, Martin B.;Bellmann, Erika;Baetzold, John P.
    • Journal of Information Display
    • /
    • 제4권3호
    • /
    • pp.1-5
    • /
    • 2003
  • Laser-Induced Thermal Imaging (LITI) is a laser addressed patterning process and has unique advantages such as high-resolution patterning with over all position accuracy of the imaged stripes of within 2.5 micrometer and scalability to large-size mother glass. This accuracy is accomplished by real-time error correction and a high-resolution stage control system that includes laser interferometers. Here the new concept of hybrid system that complement the merits of small molecule and polymer to be used as an OLED; our system can realize easy processing of light emitting polymers and high luminance efficiency of small molecules. LITI process enables the stripes to be patlerned with excellent thickness uniformity and multi-stacking of various functional layers without having to use any type of fine metal shadow mask. In this study, we report a full-color hybrid OLED using the multi-layered structure consisting of small molecules and polymers.

Strain elastography of tongue carcinoma using intraoral ultrasonography: A preliminary study to characterize normal tissues and lesions

  • Ogura, Ichiro;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki
    • Imaging Science in Dentistry
    • /
    • 제48권1호
    • /
    • pp.45-49
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the quantitative strain elastography of tongue carcinoma using intraoral ultrasonography. Materials and Methods: Two patients with squamous cell carcinoma (SCC) who underwent quantitative strain elastography for the diagnosis of tongue lesions using intraoral ultrasonography were included in this prospective study. Strain elastography was performed using a linear 14 MHz transducer (Aplio 300; Canon Medical Systems, Otawara, Japan). Manual light compression and decompression of the tongue by the transducer was performed to achieve optimal and consistent color coding. The variation in tissue strain over time caused by the compression exerted using the probe was displayed as a strain graph. The integrated strain elastography software allowed the operator to place circular regions of interest (ROIs) of various diameters within the elastography window, and automatically displayed quantitative strain (%) for each ROI. Quantitative indices of the strain (%) were measured for normal tissues and lesions in the tongue. Results: The average strain of normal tissue and tongue SCC in a 50-year-old man was 1.468% and 0.000%, respectively. The average strain of normal tissue and tongue SCC in a 59-year-old man was 1.007% and 0.000%, respectively. Conclusion: We investigated the quantitative strain elastography of tongue carcinoma using intraoral ultrasonography. Strain elastography using intraoral ultrasonography is a promising technique for characterizing and differentiating normal tissues and SCC in the tongue.

상용화 된 고속카메라와 후두내시경을 이용한 성대촬영 방법의 소개 (Commercially Available High-Speed Cameras Connected with a Laryngoscope for Capturing the Laryngeal Images)

  • 남도현;최홍식
    • 대한후두음성언어의학회지
    • /
    • 제21권2호
    • /
    • pp.133-138
    • /
    • 2010
  • Background and Objectives : High-speed imaging can be useful in studies of linguistic and artistic singing styles, and laryngeal examination of patients with voice disorders, particularly in irregular vocal fold vibrations. In this study, we introduce new laryngeal imaging systems which are commercially available high speed cameras connected with a laryngoscope. Materials and Method : The laryngeal images were captured from three different types of cameras. First, the adapter was made to connect with laryngoscope and Casio EX-F1 to capture the images using $2{\times}150$ Watt Halogen light source (EndoSTROB) at speeds of 1,200 tps (frame per second)($336{\times}96$). Second, Phantom Miro ex4 was used to capture the digital laryngeal images using Xenon Nova light source 175 Watt (STORZ) at speeds of 1,920 fps ($512{\times}384$). Finally, laryngeal images were captured using MotionXtra N-4 with 250 Watt halogen lamp (Olympus CLH-250) light source at speeds of 2,000tps ($384{\times}400$) by connecting with laryngoscope. All images were transformed into the Kymograph using KIPS (Kay's image processing Software) of Kay Pentex Inc. Results: Casio EX-F1 was too small to adjust the focus and screen size was diminished once the images were captured despite of high resolution images. High quality of color images could be obtained with Phantom Miro ex4 whereas good black and white images from Motion Xtra N-4 Despite of some limitations of illumination problems, limited recording time capacity, and time consuming procedures in Phantom Miro ex4 and Motion Xtra N-4, those portable devices provided high resolution images. Conclusion : All those high speed cameras could capture the laryngeal images by connecting with laryngoscope. High resolution images were able to be captured at the fixed position under the good lightness. Accordingly, these techniques could be applicable to observe the vocal fold vibration properties in the clinical practice.

  • PDF

평안감사향연도(平安監司饗宴圖)의 채색 재료 특성 연구 -연광정연회도(練光亭宴會圖)를 중심으로- (A Study of the Characteristics of Painting Materials Used in Welcome Feast for the Pyeongan Governor: Focusing on Banquet at Yeongwangjeong Pavilion)

  • 박진호;장연희;고수린
    • 박물관보존과학
    • /
    • 제28권
    • /
    • pp.109-136
    • /
    • 2022
  • 본 연구에서는 조선 후기 기록화인 《평안감사향연도》 총 3점 중 <연광정연회도>를 분석하여 채색 재료를 규명했다. 포인트 위주의 분석으로 인해 발생 가능한 문제를 최소화하고자 우선 파장별 이미지를 촬영했다. 엑스선을 통해 먹, 금, 유·무기 안료를 분류했고, 적외선으로 먹과 구리계 안료를 파악했다. 초분광으로는 흑색, 청색, 녹색 재료 중에서 안료와 유기 염료를 구별해냈다. 색상별 선정 지점을 분석하여 백색(연백), 흑색(먹/쪽), 적색(연단+진사), 분홍색(염료), 자주색(염료), 갈색(산화철), 황색(석황/염료), 녹색(석록/석록+염료/쪽)과 청색(석청/연백+쪽/쪽), 자색(쪽+연지), 금색(금박) 등의 재료를 규명했다. 향후 파장별 라이브러리가 확보되면 더 효율적인 분석이 가능할 것으로 기대된다.