• Title/Summary/Keyword: color Doppler ultrasonography

Search Result 36, Processing Time 0.028 seconds

Prediction of successful caudal epidural injection using color Doppler ultrasonography in the paramedian sagittal oblique view of the lumbosacral spine

  • Yoo, Seon Woo;Ki, Min-Jong;Doo, A Ram;Woo, Cheol Jong;Kim, Ye Sull;Son, Ji-Seon
    • The Korean Journal of Pain
    • /
    • v.34 no.3
    • /
    • pp.339-345
    • /
    • 2021
  • Background: Ultrasound-guided caudal epidural injection (CEI) is limited in that it cannot confirm drug distribution at the target site without fluoroscopy. We hypothesized that visualization of solution flow through the inter-laminar space of the lumbosacral spine using color Doppler ultrasound alone would allow for confirmation of drug distribution. Therefore, we aimed to prospectively evaluate the usefulness of this method by comparing the color Doppler image in the paramedian sagittal oblique view of the lumbosacral spine (LS-PSOV) with the distribution of the contrast medium observed during fluoroscopy. Methods: Sixty-five patients received a 10-mL CEI of solution containing contrast medium under ultrasound guidance. During injection, flow was observed in the LSPSOV using color Doppler ultrasonography, following which it was confirmed using fluoroscopy. The presence of contrast image at L5-S1 on fluoroscopy was defined as "successful CEI." We then calculated prediction accuracy for successful CEI using color Doppler ultrasonography in the LS-PSOV. We also investigated the correlation between the distribution levels measured via color Doppler and fluoroscopy. Results: Prediction accuracy with color Doppler ultrasonography was 96.9%. The sensitivity, specificity, positive predictive value, and negative predictive value were 96.7%, 100%, 100%, and 60.0%, respectively. In 52 of 65 patients (80%), the highest level at which contrast image was observed was the same for both color Doppler ultrasonography and fluoroscopy. Conclusions: Our findings demonstrate that color Doppler ultrasonography in the LS-PSOV is a new method for determining whether a drug solution reaches the lumbosacral region (i.e., the main target level) without the need for fluoroscopy.

Incidence of Deep Vein Thrombosis before Hip Fracture Surgery Diagnosed by Color Doppler Sonography Surveillance (고관절 주위 골절환자에서 술 전 색 도플러 초음파를 이용하여 진단한 심부 정맥 혈전의 빈도)

  • Jung, Jae-Hoon;Lee, Kyung-Jae;Min, Byung-Woo;Son, Eun-Seok;Koo, Tae-Won
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.7 no.2
    • /
    • pp.98-104
    • /
    • 2014
  • Purpose: To evaluate the incidence of deep vein thrombosis (DVT) before hip fracture by duplex color Doppler ultrasonography. Materials and Methods: From June 2013 to May 2014, 27 patients who had agreed to perform color Doppler ultrasonography before hip fracture surgery were evaluated for the incidence of DVT. Patients who had history of DVT were excluded. Five patients were men and 19 patients were women. The mean age was 74.3 years old (41-87). There were 15 cases of femoral neck fracture, 11 cases of intertrochanteric fractures and one case of acetabular fracture. Surgical intervention underwent within 48 hours from admission and duplex color Doppler ultrasonography was carried out at the day of admission. Results: DVT occurred in six cases (22.2%). Four cases (14.8%) occurred in proximal deep vein and two cases (7.4%) occurred in distal deep vein. The mean period of immobilization was longer in patients who had DVT. But there was no significant difference. The mean age was 79 years old (75-87) in patients who had DVT and 72 years old (65-86) in patients who had not. There was significant difference (p=0.038). Conclusion: The incidence of DVT which was diagnosed by duplex color Doppler ultrasonography before hip fracture surgery was relatively high (22.2%). So it is necessary to undergo duplex color Doppler ultrasonography more aggressively to rule out DVT before hip fracture surgery.

  • PDF

Extraction of Blood Flow of Brachial Artery on Color Doppler Ultrasonography by Using 4-Directional Contour Tracking and K-Means Algorithm (4 방향 윤곽선 추적과 K-Means 알고리즘을 이용한 색조 도플러 초음파 영상에서 상환 동맥의 혈류 영역 추출)

  • Park, Joonsung;Kim, Kwang Baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.11
    • /
    • pp.1411-1416
    • /
    • 2020
  • In this paper, we propose a method of extraction analysis of blood flow area on color doppler ultrasonography by using 4-directional contour tracking and K-Means algorithm. In the proposed method, ROI is extracted and a binarization method with maximum contrast as a threshold is applied to the extracted ROI. 4-directional contour algorithm is applied to extract the trapezoid shaped region which has blood flow area of brachial artery from the binarized ROI. K-Means based quantization is then applied to accurately extract the blood flow area of brachial artery from the trapezoid shaped region. In experiment, the proposed method successfully extracts the target area in 28 out of 30 cases (93.3%) with field expert's verification. And comparison analysis of proposed K-Means based blood flow area extraction on 30 color doppler ultrasonography and brachial artery blood flow ultrasonography provided by a specialist yielded a result of 94.27% accuracy on average.

Usefulness of Color Doppler for Non-dilatational Ureteral Stone (비확장성 요관결석에 대한 컬러 도플러의 유용성)

  • Sim, Hyun-Sun
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.1
    • /
    • pp.120-128
    • /
    • 2017
  • Acute flank pain from urolithiasis is the most common condition in people visiting emergency rooms. This study is to evaluate the usefulness of color Doppler in detecting ureteral stones in patients without hydronephrosis. We performed ultrasonography and retrospective analysis on 161 patients who were suspected of urinary stones through plain radiography of the kidney, ureter, and bladder examination or urine tests that showed positive signs of hematuria. In ultrasonography, a total of 154 (95.6%) cases from the 161 patients were diagnosed with ureteral stones. In color Doppler, ureteral stones with twinkling artifact (TA) in the absence of hydronephrosis was shown in 18 (85.7%) cases of the 21 patients(p<0.001). The use of color Doppler has a high diagnostic efficacy for the detection of indistinguishable stones, non-dilatational ureteral stones, and middle ureter stones.

Color Doppler Ultrasonographic Evaluation in Observing the Affects of $Osteoset^{(R)}$ on Radial Defects in Beagle Dogs (개에서 $Osteoset^{(R)}$의 요골 결손부 충진에 대한 색도플러초음파검사의 유용성 평가)

  • Jeon, Jong-Hoon;Seong, Yun-Sang;Eom, Ki-Dong;Kim, Jae-Hoon;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • This study is conducted to compare ultrasonographs with plain radiographs in monitoring bone regeneration during reconstruction of critical sized radial defects in dogs. A 15 mm bony defect was taken on each of the eight dog's radius using an electrical saw and an external fixator was applied. The experimental groups were divided into non-treated group(group 1) and $Osteoset^{(R)}$-treated group(group 2). Each fracture site was evaluated using plain radiography and ultrasonography. Radiographic callus formation occurred after $11.50{\pm}1.12$ days in group 1 and $11.50{\pm}0.5$ days in group 2. Neovascularized flow signal could be seen $6.50{\pm}1.5$ days and the vascular signal disappeared after $45.00{\pm}6.16$ days after operation in group 1. Neovascularized flow signal was observed $6.75{\pm}1.78$ days and vascular signal disappeared $23.25{\pm}3.03$ days after surgery which was caused by acoustic shadowing in group 2. Early stages of regeneration were observed more clearly with color Doppler ultrasonography than with plain radiography. Also from the results it is concluded that color Doppler ultrasonography are useful in observing initial stages of bone repair.

Usefulness of Twinkling Artifacts in Color Doppler Ultrasonography (컬러 도플러 초음파에서 Twinkling artifacts의 유용성)

  • Sim, Hyun-Sun;Kwon, Kyung-Tae
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.10
    • /
    • pp.291-298
    • /
    • 2016
  • The aim of the study was to investigate the diagnostic value of the color Doppler twinkling artifact in disease of urinary system. The intensity of twinkling artifact(TA) with color Doppler was classified into 3 levels, 0(non-TA) to 3(distinct TA). In the in vitro study, acorn jelly with various materials on top was examined using color Doppler at B-mode sonography in a water bath for TA. 31 patients with diagnosis of urinary calculi(renal stones 16, urinary stones 15) based on B-mode sonography were studied in vivo for TA. The materials with rough surfaces such as salt, screw and cubics at B-mode sonography with color Doppler contributed to causing TA. At B-mode sonography without color Doppler 37% of renal stones and 60% of ureter stones were detected. but at B-mode sonography with color Doppler TA was demonstrated for all cases. Superficial roughness of materials affected occurrence of TA at B-mode sonography with color Doppler. Therefore, TA at B-mode sonography without color Doppler could play a role in confident diagnosis of the disease of urinary system.

Evaluation of ultrasonography as a diagnostic tool in the management of periapical cysts and granulomas: A clinical study

  • Avci, Fatma;Etoz, Meryem;Ustun, Yakup;Arslan, Tugrul
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.209-217
    • /
    • 2022
  • Purpose: The aim of this study was, firstly, to determine the concordance of ultrasonographic and histopathological diagnoses in patients in whom apical resection was already indicated. Secondly, this study aimed to determine whether lesions were periapical granulomas or cysts, and to compare them after root canal treatment using ultrasonography and periapical radiographs. Materials and Methods: In the first stage of the study, ultrasonographic and histopathologic diagnoses of 10 lesions were compared. Secondly, the periapical radiographs and ultrasonographic images of 44 lesions were measured. The presence of internal vascularity was determined by ultrasonographic color and power Doppler modes. Follow-up examinations of healing after root canal treatment were performed using ultrasonography and periapical radiographs, and these modalities were compared. Results: In the periapical granuloma and cyst groups, the measurement values decreased for all variables. There was no significant difference in the dimensional changes of lesions between the 2 groups, and ultrasonography and periapical radiographs were compatible. The pre-diagnoses were compared with histopathological diagnoses and were found to be compatible. Conclusion: The ultrasonographic color and power Doppler techniques could be an effective method for diagnosing periapical lesions as cysts or granulomas. After root canal treatment of granulomas and cysts, the dimensional shrinkage and healing patterns appear to be similar. Ultrasonography and periapical radiographs were consistent in terms of dimensional comparisons, and ultrasonography may be an alternative method for follow-up of the healing of periapical lesions.

Case Analysis of Persistent Vasospasm after Cerebral Artery Aneurysm Rupture by Using Transcranial Color Coded Doppler Ultrasonography (경두개 색조 도플러 초음파검사를 이용한 대뇌동맥 파열 이후 지속적인 혈관 연축 증례 분석)

  • Ji, Myeong-Hoon;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.15-23
    • /
    • 2021
  • In this case analysis, a patient was diagnosed with subarachnoid hemorrhage (SAH) in a 49-year-old female and showed persistent vasospasm after coil emboilzation in an aneurysm. The patient suffered from persistent vasospasm and performed angioplasty a total of 6 times. Transcranial color coded doppler (TCCD) was performed 12 times to monitor vasospasm. As a result, repetitive cerebral blood flow tests were low cost and safely performed without exposure to invasive radiation through the TCCD, and the repeatability and reproducibility of the test were confirmed with the capabilities of a trained professional radiological technologist.

Differentiation of Malignant and Benign Cervical Lymph Nodes with Color and Pulsed Doppler Ultrasonography (색채 및 펄스 도플러 초음파를 이용한 경부 림프절의 양성과 악성의 감별)

  • Lee Kang-Dae;Lee Bong-Hee;Lee Yun-Woo;Lee Hwan-Ho;Ahn Kyong-Mo;Lee Young-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.17 no.1
    • /
    • pp.19-25
    • /
    • 2001
  • Objectives: The clinical efficacy of the color and pulsed Doppler ultrasound with spectral waveform analysis for differentiation of malignant from benign cervical lymphadenopathy was prospectively evaluated in cervical lymphadenopathy. Materials and Methods: Color and pulsed Doppler ultrasound examination was prospectively performed in 32 cervical lymph nodes in 28 patients. These 10 nodes from 10 patients were malignant and 22 nodes from 18 patients were benign, proved by operation, biopsy, and follow-up examination. Another 12 lymph nodes from 12 normal volunteers were evaluated as control group. The peak systolic velocity (PSV), minimal diastolic velocity (MDV) , and resistive indexes (RI) of arterial flows within the 32 lymph nodes were assessed to differentiate the malignant from benign nodes with pulsed Doppler ultrasonography. The results were qualitified with one-way ANOVA and Bonferroni method of multiple comparison. Results: The mean values of PSV of malignant, benign, and control nodes were 38.2(10.1-134)cm/sec, 23.3(9-38.5) cm/sec and 11.8(6.7-18.1) cm/sec, respectively. The mean values of MDV of them were 0.9(-7.5-10.7)cm/sec, 9.7(2.9-18.6)cm/sec and 6.5(3.7-9.3)cm/sec, respectively. However, there was no statistical significance in differentiation of malignant from benign nodes with PSV and MDV. The mean values of RI of malignant, benign, and control nodes were 0.99(0.80-1.30), 0.59(0.46-0.77) and 0.45(0.38-0.50), respectively. RI value of 0.8 is suggestive value for discrimination of malignant from benign lymphadenopathy during examination of color Doppler ultrasound of cervical lymphadenopathy. Conclusion: Color and pulsed Doppler ultrasound examination with spectral waveform analysis may be quite helpful in the differentiation between benign and malignant alterations of cervical lymph nodes.

  • PDF

Renal hemodynamics in dogs with experimental hydronephrosis treated with transarterial embolization of renal artery (신장동맥색전술을 실시한 개의 실험적 수신증의 혈동학)

  • Chang, Dongwoo
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.413-419
    • /
    • 2001
  • This study was performed to evaluate the renal hemodynamics using color Doppler ultrasonography in dogs with unilateral experimental hydronephrosis treated with transarterial embolization of the renal artery (TAE-RA). Experimental hydronephrosis was induced by ligation of unilateral ureter in 12 dogs. The mean resistive index (RI) value of kidney was significantly increased at 4, 9, 17 days after ligation of ureter. Unilateral hydronephrosis was established in 12 dogs at 17 days after ligation of ureter. Renal artery embolization was performed using selective catheterization in the hydronephrotic kidney of seven dogs and EKG, $SpO_2$body temperature, pulse, and respiratory rate were within normal ranges during procedures. There were no dogs expired after TAE-RA and no side effects associated with regurgitation of iohexol-ethanol solution. In color Doppler ultrasonographic findings, there was no blood flow into the embolized kidneys treated by TAE-RA, however, blood flow signal was found in contralateral normal kidney of dogs treated with TAE-RA compared to that of normal kidney in normal control group. It is concluded that TAE-RA does not affect the hemodynamics of contralateral normal kidney in dogs with experimental hydronephrosis and color Doppler ultrasonography is simple and non-invasive modality for the monitoring of the revascularization of the renal artery after TAE-RA.

  • PDF