• Title/Summary/Keyword: colloid

Search Result 429, Processing Time 0.033 seconds

Quantitative Evaluation of Dysphagia Using Scintigraphy (신티그라피를 이용한 연하곤란증의 정량적 평가)

  • Park, Seok-Gun;Hyun, Jung-Keun;Lee, Seong-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.276-289
    • /
    • 1998
  • Purpose: To evaluate dysphagia objectively and quantitatively, and to clarify the effect of neck position and viscosity changes in patients with aspiration and laryngeal penetration. Materials and Methods: We studied 35 patients with dysphagia and 21 normal controls using videofluoroscopy and scintigraphy. Videofluoroscopy was performed with barium with three different viscosity, and scintigraphy was done with water, yogurt, and steamed egg mixed with Tc-99m tin colloid. If aspiration was found during videofluoroscopic examination, patient's neck position was changed and study repeated. Videofluoroscopy was analyzed qualitatively. We calculated 7 quantitative parameters from scintigraphy. According to the videofluoroscopic findings, we divided patients into 3 subgroups; aspiration, laryngeal penetration, and no-aspiration group. Results: The result of videofluoroscopy revealed that the most common finding was the delay in triggering pharyngeal swallow. Pharyngeal transit time (PTT) and pharyngeal swallowing efficiency(PSE) in patients with aspiration were signifi-cantly different from other groups. After neck position change, aspiration could be reduced in all of 7 patients, and laryngeal penetration reduced by about 82%. PTT and PSE were also improved after position change. Aspiration and laryngeal penetration occurred more frequently in thin liquid swallowing than in thick liquid and solid swallowing. Conclusion: PTT and PSE were useful for the evaluation of dysphagia. Aspiration and laryngeal penetration could be reduced when appropriate position assumed. We could decrease the chance of aspiration by changing the patient diet consistency. Scintigraphy might be useful tool to quantitate and follow up these changes.

  • PDF

Gastric Emptying Time in Acute and Chronic Hepatitis B Patients (급성 및 만성 B형 간염환자의 위배출시간에 관한 연구)

  • Lee, Kyung-Han;Kim, Ho-Jong;Choo, Kil-Yeon;Kim, Jung-Han;Kim, Jae-Myung;Won, Chong-Hyun;Park, Gwun-Taek;Kim, Seoung-Wok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.307-311
    • /
    • 1992
  • Anorexia, nausea, and vomiting are one of the most frequent symptoms in viral hepatits patients. These may be due to poorly detoxified substances by dysfunctioned hepatocytes or by gastritis, but the pathophysiology is not totally understood. The symptoms interfere with adequate nutrient intake and are managed by metoclopramide, which accelerates gastric emptying. Thus delayed gastric emptying may well be a contributing factor to such symptoms. To determine such a relationship, we measured gastric emptying time in 11 normal subjects,9 acute (AVH), and 12 chronic B viral hepatitis (CVH) patients. All were males with a mean age of 23 years. An egg was labeled with 0.5 mCi of $^{99m}Tc-sulfur$ colloid, fried, then eaten between 2 slices of bread with 100 cc of water. Anterior and posterior images were taken at 20 minute intervals over a 2 hour period. A geometric mean of activity pertaining to the gastric region was measured, and $T_{1/2}$ was calculated from the time activity curve. $T_{1/2}$ for normal the group was $57.8{\pm}6.3$ minutes while that for the AVH and CVH group was $58.2{\pm}8.2$ (p=0.40) and $64.1{\pm}10.5$ (p=0.09), respectively. There was 1 AVH Patient and 4 CVH patients with prolonged $T_{1/2}$. Anorexia and nausea was seen in 71% and 46% of the patients, respectively. 80% and 60% of the patients with prolonged $T_{1/2}$ had anorexia and nausea, respectively.

  • PDF

Tc-99m Labeling of Dione Bisoxime Compounds (Dione Bisoxime 계통의 화합물에 대한 테크네슘표지 원리에 관한 연구)

  • Jeong, Jae-Min;Cho, Jung-Hyuk;Oh, Seung-Joon;Lee, Myung-Chul;Chung, Soo-Wook;Chung, June-Key;Lee, Dong-Soo;Kwark, Cheol-Eun;Lee, Kyung-Han;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.110-117
    • /
    • 1995
  • Tc-99m Labeled hexamethylenepropyleneamineoxime ([$^{99m}Tc$]-HMPAO) is a famous amino-oxime compound and is widely used to construct SPECT images of cerebral blood flow. To investigate the relationship between chemical structure and radiolabeling in these kind of diamine-oxime compounds, we synthesized seven compounds by Schiff's base formation and successive reduction with sodium borohydride. They were (RR/SS )-4,8-diaza-3,6,6,9-tetramethylundecane-2,10-dione bisoxime (2), (RR/SS/meso)-4,8-diaza-3,9-dimethy-lundecane-2,10-dione bisoxime (4), (RR/SS/meso)-4,8-diaza-3,10-dimethyldodecane-2,11-dione bisoxime (5), (RR/SS/meso)-4,7-diaza-3,6,6,8-tetramethyldecane-2,9-dione bisoxime (8), (RR/SS/meso)-4,7-diaza-5,6-cyclohexyl-3,8-dimethyldecane-2,9-dione bisoxime (10), (RR/SS/meso)-3,4-bis(1-aza-2-methyl-3-oxime-1-butyl)-benzoic acid (12), and (RR/SS/ meso)-2,3-bis(1-aza-2-methyl-3-oxime-1-butyl) benzophenone (14). Chemical structures of all the synthesized compounds were identified by taking $^1H$ spectrum. Among them, 2 and 4 are propyleneamine oxime (PnAO), 6 is butyleneamine oxime (BnAO) and 8, 10, 12 and 14 are ethyleneamine oxime (EnAO). Each compound (0.5 mg) was incubated with stannous chloride (0.5 g - 8 g), carbonate-bicarbonate buffer (final concentration = 0.1 M, pH 7 - pH 10) and Tc-99m-pertechenate (1 ml). Tc-99m labeling of these compounds were checked by ITLC (acetone), ITLC (normal saline), reverse phase TLC (50 % acetonitrile) and ITLC (ethyl acetate). According to the results, EnAO's were not labeled by Tc-99m in any of above condition. About 11 % of maximum labeling efficiency was obtained with BnAO. However, 4 (PnAO) was labeled with Tc-99m to 85 % which is similar to the labeling efficiency of 2 (HMPAO). Hydrophilic impurity (9 % ) was the most significant problem with the labeling of 4, however, pertechnetate (3 % ) and colloid (3 %) were minor problem. In conclusion, we synthesized seven diamine blsoxlme compounds. Among them, four EnAO compounds were not labeled by Tc-99m. A BnAO was labeled poorly and two PnAO's were labeled well. These labeling can be explained by tertiary structure of their Tc-99m chelate.

  • PDF

Bone Marrow Immunoscintigraphy for the Detection of Skeletal Metastasis in Malignant Tumors: A Comparison with $^{99m}Tc$-MDP Bone Scan (악성종양에서 골수면역신티그라피를 이용한 골수전이의 평가 : $^{99m}Tc$-MDP 뼈스캔과의 비교)

  • Lee, Kyung-Han;Choi, Chang-Woon;Bang, Yung-Jue;Chung, Jun-Key;Chung, Hong-Keun;Lee, Myoung-Chul;Kim, Byoung-Kook;Kim, Noe-Kyeong;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.89-97
    • /
    • 1994
  • Although bone scan is a highly sensitive test for detecting bone metastasis, its findings are often limited in specificity and cannot be used for assessing the bone marrow. Bone marrow scintigraphy may provide useful information but previous experience with radiolabelled colloid has been disappointing. Recently, $^{99m}Tc$ labeled anti-granulocyte monoclonal antibody (anti-NCA-95 MAb) has been introduced as a new bone marrow imaging agent. To evaluate the usefulness of $^{99m}Tc$ anti-NCA MAb bone marrow scans for detecting skeletal metastasis, bone marrow scans of 44 malignant tumor patients were evaluated and compared with bone scan findings. Bone scan showed abnormal lesions in 26(59%) cases, and 18 of these patients also had an abnormal bone marrow scan. Seven of the 8 patients who had normal bone marrow scan despite bone scan lesions were confirmed to be free from metastasis. There was one case with a marrow defect despite normal bone scan but the presence of metastasis was not determined due to loss of follow up. Bone scan demonstrated a total of 64 lesions while bone marrow scan showed 38 lesions. Fifty percent (32/64) of the bone scan lesions had matching marrow defects while the remaining 50% did not. Most of these non matched lesions were suggested to be nonspecific lesions such as rib fractures or degenerative change. Meanwhile bone marrow scan was able to detect 6 new lesions not detected by bone scan, bit metastasis in each lesion was not confirmed. Bone marrow scan was also helpful in assessing equivocal bone scan lesions to be of metastatic nature in 10 patients by demonstrating a matched marrow defect. Thus $^{99m}Tc$ anti-NCA MAb bone marrow scan can help exclude metastasis in patients with nonspecific bone scan lesions and may be able to detect metastatic lesions not seen with bone scan. It appears useful as a complementary study to bone scan in evaluating malignant tumor patients.

  • PDF

A Study on Synthesis and Dispersion of Silver Nano Particle Using Trisodium Citrate (Trisodium Citrate을 이용한 은 나노입자의 합성 및 분산성에 관한 연구)

  • Lee, Jong Jib
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.772-779
    • /
    • 2016
  • Silver nanoparticles were prepared by reacting silver nitrate and trisodium citrate in an aqueous solution. Their size and shape were investigated by scanning electron microscopy (SEM). The synthesis was carried with different silver nitrate concentration, addition of TSC, solvent, surfactant, ultrasonication, and dispersing agent. With higher concentration of silver nitrate or TSC, the particles became large or agglomerated. The SEM results showed that the nanoparticles have spherical and pseudospherical shape with a narrow size distribution. The hydrophobic solvent did not affect the dispersibility, but the hydrophilic solvent enhanced it. The addition of HPMC surfactant caused the size to increase (50-100 nm) with non-uniform shapes and partial agglomeration. The dispersibility was significantly improved by ultrasonication for over 3 hours after the addition of a dispersing agent. Complete dispersion was achieved by adding the dispersant, and the nanoparticle sizes were as follows: 30-40 nm (BYK-182) < 42-78 nm (BYK-192) < 51-113 nm (BYK-142). The nanoparticles were 38.45-46.28 nm after the addition of 2-4 wt% TSC in 0.002 M silver nitrate solution.

Sorption of aqueous uranium(VI) ion onto a cation-exchangeable K-birnessite colloid (양이온 교환능을 갖는 K-Birnessite 콜로이드에 의한 수용성 우라늄(VI) 이온의 흡착 연구)

  • Kang, Kwang-Cheol;Kim, Seung-Soo;Baik, Min-Hoon;Kwon, Soo-Han;Rhee, Seog-Woo
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.566-571
    • /
    • 2010
  • This paper describes the sorption behaviors of aqueous uranium ions on the K-birnessite. K-birnessite was synthesized by adding a concentrated HCl to an aqueous solution of $KMnO_4$. Physicochemical characteristics of the K-birnessite, such as structure, specific surface area and surface charge, were investigated. K-birnessite is a layered material and the $K^+$ ions exist in the interlayer of layered K-birnessite. BET specific surface area of the K-birnessite was 38.30 m2/g. The surface charge of K-birnessite was $-1.65\;C/m^2$ at pH 5.00 and ionic strength of 0.010 M $NaClO_4$, at which the sorption experiments of uranium ions were carried out. Uranium ions were incorporated into the interlayer of the K-birnessite by cation-exchange reaction with $K^+$ ions, and the distribution coefficient is quite similar to those of common ion-exchange materials. The results might be applicable in the retardation of migration of radioactive materials from the underground disposal site of high-level radioactive waste.

Effect of the Sulfur Removal in Manufacturing Pt/C Electrocatalysts on the Performance of Phosphoric Acid Fuel Cell (인산형 연료전지용 백금촉매제조에서 황의 제거에 따른 전극 성능)

  • Shim, Jae-Cheol;Lee, Kyung-Jik;Lee, Ju-Seong
    • Applied Chemistry for Engineering
    • /
    • v.9 no.4
    • /
    • pp.486-490
    • /
    • 1998
  • Pt/C powder which was used as electrocatalyst in a Phosphoric Acid Fuel Cell(PAFC) was fabricated by colloid method. It was reported that the sulfur from reductant, $Na_2S_2O_4$, worked as a poison against catalyst during long term operation. To remove these sulfurs, we try to treat Pt/C powder by three different methods. First, we tried to remove the sulfur according to temperature and time in $H_2$ atmosphere. As the heat treatment temperature is raised up, the effect of the removal is increased but the electrode performance is decreased because of the growth of Pt particle size. The optimal heat treatment temperature is $400^{\circ}C$, the size of Pt particle is approximately $35{\sim}40{\AA}$ and the electrode performance is $360mA/cm^2$ at 0.7 V. At $400^{\circ}C$, even though the time of heat treatment is extended, size of Pt, amounts of remaining sulfur and electrode performance is almost constant. Secondly, when we removed in a crucible at $900^{\circ}C$ the removal of the sulfur was not better, but the size of Pt particle, approximately $80{\AA}$, was smaller than that of heat treatment in $H_2$ atmosphere at $900^{\circ}C$. Lastly we treated with solvents such as acetone, benzene, and carbon disulfide. It was observed that sulfur components were removed partly by extraction with solvents, the electrode performances were similar each other.

  • PDF

Improvement in the Dispersion Stability of Iron Oxide (Magnetite, Fe3O4) Particles with Polymer Dispersant Inject (고분자 분산제 주입을 통한 철산화물(Magnetite, Fe3O4) 입자의 분산 안정성 향상)

  • Song, Geun Dong;Kim, Mun Hwan;Lee, Yong Taek;Maeng, Wan Young
    • Applied Chemistry for Engineering
    • /
    • v.24 no.6
    • /
    • pp.656-662
    • /
    • 2013
  • The iron oxide ($Fe_3O_4$) particles in the coolant of the secondary system of a nuclear power plant reduce the heat transfer performance or induce corrosion on the surface of the heat transfer tube. To prevent these problems, we conducted a study to improve the dispersion stability of iron oxide using polymeric dispersant injection in simulated secondary system water. The three kinds of anionic polymers containing carboxyl groups were selected. The dispersion characteristics of the iron oxide particles with the polymeric dispersants were evaluated by performing a settling test and measuring the transmission, the zeta potential, and the hydrodynamic particle size of the colloid solutions. Polymeric dispersants had a significant impact on the iron oxide dispersion stability in an aqueous solution. While the dispersant injection tended to improve the dispersion stability, the dispersion stability of iron oxide did not increase linearly with an increase in the dispersant concentration. This non-linearity is due to the agglomerations between the iron oxide particles above a critical dispersant concentration. The effect of the dispersant on the dispersion stability improvement was significant when the dispersant concentration ratio (ppm, dispersant/magnetite) was in the range of 0.1 to 0.01. This suggests that the optimization of dispersant concentration is required to maximize the iron oxide removal effect with the dispersant injection considering the applied environments, the iron oxide concentration and the concentration ratio of dispersant to iron oxide.

Fabrication of Nano $Y_{2}O_{3}-CeO_{2}$ Sintered Body Using Dispersion Stability (분산 안정성을 이용한 나노 $Y_{2}O_{3}-CeO_{2}$ 소결체의 제조)

  • Kim, Eun-Jung;Lee, Sang-Hoon;Choi, Sung-Churl
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.9
    • /
    • pp.853-859
    • /
    • 2001
  • The dispersion stability of nano $Y_2O_3-CeO_2$ system was investigated using colloid surface chemistry. Green body of $Y_2O_3$ doped $CeO_2$ was prepared by slip casting in and aqueous system. The dispersion stability of suspension between powders and organic additive was accomplished through electrokinetic behavior of suspension, which was done by ESA apparatus. The dynamic mobility of particles was enhanced when the anionic dispersant of the amount of 1wt% was added. The dissolution of $Y^{3+}$ ion in suspension occurred in the acidic region so that pH value in slurries did not move to below 7.0. In the $CeO_2-Y_2O_3$ system, optimal preparation of suspension was made after adding the anionic dispersant as the amount of 1wt% and pH value of 11.0, and then slip-cast and sintered at 1400$^{\circ}$C, 2 hrs. It appeared relative density of >98% and homogeneous distribution of Y element in depth direction as well as in the microstructure of surface.

  • PDF

The Effects of Charge Transfer Complex on the Reaction of N,N-dimethylaniline and Iodine (N,N-Dimethylaniline과 Iodine간의 반응에 있어서 Charge Transfer Complex의 영향)

  • Oh-Yun Kwon;U-Hyon Paek;Eung-Ryul Kim
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.2
    • /
    • pp.191-196
    • /
    • 1992
  • Reaction of N,N-dimethylaniline(N,N-DMA) and iodine in $CHCl_3,\;CH_2Cl_2 : CHCl_3$(1:1), $CH_2Cl_2$(1:1), and CH2Cl2 has been studied kinetically by using conductivity method. Pseudo first-order rate constants ($k_{obs}$) and second-order rate constants ($k_{obs}$/[N,N-DMA]) are dependent on the N,N-DMA concentration. Second-order rate constants obtained were decreased with increasing N,N-DMA concentration. We analysed these results on the basis of formation of charge transfer complex as a reaction intermediate. From the construction of reaction scheme and activation parameters for the formation and transformation of charge transfer complex. The equilibrium constants decreased when the dielectric constant of solvent was increased, and the value is 1.9${\sim}$4.2$M^{-1}$. The rate of transformation are markedly affected by the solvent polarity.${\Delta}H^{\neq}$ is 6.3-12.6kJ/mol, and ${\Delta}S^{\neq}$ is large negative value of -234J/mol K.

  • PDF