• Title/Summary/Keyword: collimation

Search Result 114, Processing Time 0.028 seconds

Multi-tracer Imaging of a Compton Camera (다중 추적자 영상을 위한 컴프턴 카메라)

  • Kim, Soo Mee
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.18-27
    • /
    • 2015
  • Since a Compton camera has high detection sensitivity due to electronic collimation and a good energy resolution, it is a potential imaging system for nuclear medicine. In this study, we investigated the feasibility of a Compton camera for multi-tracer imaging and proposed a rotating Compton camera to satisfy Orlov's condition for 3D imaging. Two software phantoms of 140 and 511 keV radiation sources were used for Monte-Carlo simulation and then the simulation data were reconstructed by listmode ordered subset expectation maximization to evaluate the capability of multi-tracer imaging in a Compton camera. And the Compton camera rotating around the object was proposed and tested with different rotation angle steps for improving the limited coverage of the fixed conventional Compton camera over the field-of-view in terms of histogram of angles in spherical coordinates. The simulation data showed the separate 140 and 511 keV images from simultaneous multi-tracer detection in both 2D and 3D imaging and the number of valid projection lines on the conical surfaces was inversely proportional to the decrease of rotation angle. Considering computation load and proper number of projection lines on the conical surface, the rotation angle of 30 degree was sufficient for 3D imaging of the Compton camera in terms of 26 min of computation time and 5 million of detected event number and the increased detection time can be solved with multiple Compton camera system. The Compton camera proposed in this study can be effective system for multi-tracer imaging and is a potential system for development of various disease diagnosis and therapy approaches.

Evaluation to X-ray Tube Variable Beam Limiting Device Ability Test, Collimation and Beam Alignment Test of Diagnostic X-ray Unit (진단용 X선발생장치의 X선관 가변조리개 성능검사와 조사야일치검사 및 중심선속 일치검사에 대한 평가)

  • Im, In-Chul;Lee, Sang-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.3
    • /
    • pp.250-255
    • /
    • 2009
  • This study performed and evaluated the performance test in 40 general X-ray units among diagnostic X-ray units, which were being used in hospitals of gyeongsangnam-do gimhae-si through X-ray tube variable limiting device ability test, the light field and X-ray field alignment test and collimation and beam alignment test of diagnostic X-ray unit. The results are as followings: In a variable beam limiting device ability test, the result of maximum X-ray field test showed that 4(10%) of were incongruent while the result of minimum X-ray field test represented that 5(12.5%) of were incongruent. The result of the light field and X-ray field alignment test showed 23(57.5%) of were within 2% of maximum permissible level and the other 17(42.5%) units were misalignment. The result of beam alignment test represented that 11(27.5%) coincided and another 11(27.5%) within $0.5^{\circ}$ respectively, 10(25%) were $0.6^{\circ}-1.5^{\circ}$ intervals, 7(17.5%) were $1.6^{\circ}-3^{\circ}$ and 1(2.5%) were more than $3^{\circ}$.

Development of Automatized Quantitative Analysis Method in CT Images Evaluation using AAPM Phantom (AAPM Phantom을 이용한 CT 영상 평가 시 자동화된 정량적 분석 방법 개발)

  • Noh, Sung Sun;Um, Hyo Sik;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.163-173
    • /
    • 2014
  • When evaluating the spatial resolution images and evaluation of low contrast resolution using CT standard phantom, and might present a automated quantitative evaluation method for minimizing errors by subjective judgment of the evaluator be, and try to evaluate the usefulness. 120kVp and 250mAs, 10mm collimation, SFOV(scan field of view) of 25cm or more than, exposure conditions DFOV(display field of view) of 25cm, and were evaluated the 24 passing images and 20 failing images taken using a standard reconstruction algorithm by using the Nuclear Associates, Inc. AAPM CT Performance Phantom(Model 76-410). Quantitative evaluation of low contrast resolution and spatial resolution was using an evaluation program that was self-developed using the company Mathwork Matlab(Ver. 7.6. (R2008a)) software. In this study, the results were evaluated using the evaluation program that was self-developed in the evaluation of images using CT standard phantom, it was possible to evaluate an objective numerical qualitative evaluation item. First, if the contrast resolution, if EI is 0.50, 0.51, 0.52, 0.53, as a result of evaluating quantitatively the results were evaluated qualitatively match. Second, if CNR is -0.0018~-0.0010, as a result of evaluating quantitatively the results were evaluated qualitatively match. Third, if the spatial resolution, as a result of using a image segmentation technique, and automatically extract the contour boundary of the hole, as a result of evaluating quantitatively the results were evaluated qualitatively match.

FPD 공정을 위한 램프하우스 열전달 특성 연구

  • Kim, Tae-An;Seo, Won-Ho;Kim, Jun-Hyeon;Kim, Yun-Je
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.10a
    • /
    • pp.132-137
    • /
    • 2006
  • With the help of the development of digital-multimedia in the middle of 1990's, FDP(Flat Panel Display) had attracted considerable attention. Collimation proximity exposure system that transfers the pattern on wafer or glass exactly using mask and light with appropriate wavelength is core process in semiconductor and liquid display element. The performances of resolution required in precision exposure system are evaluated by resolving power, depth of focus and storage area. Most of development has targeted on these three factors. The optical design including lamp house has played an important role on the performance of exposure process. In this study, we evaluate the cooling system, concerning on exposure device with mercury lamp among the kernel equipment for the production of LCD, to prevent the instability of lighting due to long term accumulation of excessive heating inside the lamp house. Numerical analysis is conducted on full-scale model. The characteristics of three-dimensional flow, pressure and temperature distribution on exposure system are graphically depicted to estimate the whole cooling system for lamp house and to establish the design criteria.

  • PDF

THE FORMATION OF THE DOUBLE GAUSSIAN LINE PROFILES OF THE SYMBIOTIC STAR AG PEGASI

  • Hyung, Siek;Lee, Seong-Jae
    • Journal of The Korean Astronomical Society
    • /
    • v.53 no.2
    • /
    • pp.35-42
    • /
    • 2020
  • We analyze high dispersion emission lines of the symbiotic nova AG Pegasi, observed in 1998, 2001, and 2002. The Hα and Hβ lines show three components, two narrow and one underlying broad line components, but most other lines, such as HI, HeI, and HeII lines, show two blue- and red-shifted components only. A recent study by Lee & Hyung (2018) suggested that the double Gaussian lines emitted from a bipolar conical shell are likely to form Raman scattering lines observed in 1998. In this study, we show that the bipolar cone with an opening angle of 74°, which expands at a velocity of 70 km s-1 along the polar axis of the white dwarf, can accommodate the observed double line profiles in 1998, 2001, and 2002. We conclude that the emission zone of the bipolar conical shell, which formed along the bipolar axis of the white dwarf due to the collimation by the accretion disk, is responsible for the double Gaussian profiles.

Earth and Environmental Sciences with Synchrotron Radiation (방사광의 원리와 지구환경과학에의 응용)

  • 김영호
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.212-221
    • /
    • 2001
  • This paper introduces the characteristics and generation of the synchrotron radiation (SR). SR has the very high spectral brilliance, broad spectral range, X-ray wavelength tunability, high degree of polarization and collimation, and pulsed time structure. Also describes the technologies to apply in the fields of geology and environmental sciences. These include X-ray tomography, XRF, EXAFS, XANES, DAC, IVP experiments. Further, nuclear power generation and nuclear waste disposal methods are mentioned relating to energy. Using these, analyses of the chemistry, crystal structure and chemical combining states of minerals and rocks can be carried out. Applications in the fields of the economic geology, paleontology and environmental sciences are open too. Informations of the Earth interior materials' behavior under high pressure-temperature can be acquired.

  • PDF

Design and Development of Asymmetry Glass Array Lens (비축대칭 Glass Array Lens의 설계 및 개발)

  • Park, Soon-Sub;Hwang, Yeon;Lee, Ki-Young;Kim, Geon-Hee;Won, Jong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.12
    • /
    • pp.39-46
    • /
    • 2008
  • Asymmetric glass lens core for portable projection optic system was designed and simulated. And it was machined by newly developed non-rotational ultra precision grinding method. With the designed lens data which optimized for multi-collimation, we generated the we core surface data. Mold pressing conditions analyzed by FEM. In the machining process, ground profile errors were compensated based on measured data, minimized feed rate and depth of cut. The deviations of machined core profile were acceptable level for glass mold press. Mold pressed glass array lens was coated with $SiO_2\;and\;Ta_2O_5$ for anti-reflection.

Simulation of Diocotron Instability of a Hollow Electron Beam Used for the Collimation of Proton Beam

  • Jeong, Seung-Il;Lee, Yeong-Ho;Jeong, Mo-Se;Lee, Ho-Jun;Lee, Hae-Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.494-494
    • /
    • 2012
  • 최근에 현대 물리학과 과학의 정점에 있는 초전도가속기 같은 고에너지 빔 가속기 시스템에서 Diocotron instability의 연구가 재조명 되고 있다. 환형의 전자 빔 사이로 프로톤 빔을 통과시키는 구조로써 자기장과 회전하는 전자빔의 상호작용에 기초를 두고 있으며 이 환형의 전자 빔이 고에너지의 프로톤 빔을 집속하는 역할을 한다. 하지만 전자빔이 진행함과 동시에 왜곡되는 현상이 발생하는데 이 왜곡되는 현상을 충분히 조절하지 못한다면 프로톤 빔의 손실과 가속하는 빔의 에너지 저하를 초래하게 될 것이고 또한 실험장치 자체에도 큰 결함을 발생 시킬 수 있다. 따라서 Diocotron instability는 가속기를 활성화 하는데 주요한 테마가 될 것이다. 환형의 전자 빔 층은 정전기적 효과로 인해서 안쪽과 바깥쪽의 속도차가 발생하게 되고 이로 인하여 drift instability 가 발생하게 되어서 왜곡이 발생하고 결국에는 몇 개의 소용돌이를 생성하게 된다. 본 연구에서는 이를 2차원 원통형 구조의 Particle-in-cell 시뮬레이션을 통하여 연구하였으며 자기장의 효과에 따른 환형의 전자빔의 왜곡현상을 지연시키는 방안에 중점을 두었다. 특히 자기장의 세기, 전자빔의 밀도, 전자빔 층의 두께, 전자빔의 프로필의 차이에 의한 결과로 연구하였다.

  • PDF

Enrichment Measurement of Nuclear Materials by Passive Gamma-ray Analysis (수동적 감마선분석에 의한 핵물질 농축도 측정)

  • Hong, Jong-Sook;Cha, Hong-Ryul;Park, Hyoung-Nae;Lee, Byung-Doo;Park, Ho-Joon
    • Nuclear Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.233-240
    • /
    • 1991
  • U-235 enrichment has been measured non-destructively by passive gamma-ray pulse height analysis. Measurement source is 185.7 keV gamma-ray which is emitted from uranium sample during alpha decay of U-235 in it. Factors influencing the measurement such as sample composition, attenuation effect of container wall, collimation effect and counting efficiency were evaluated. Under the optimized counting system, the measured relative errors were~8%, ~8% and~1% from Tag values at 95% confidence level for depleted UF$_{6}$ cylinders, depleted UO$_2$powder, and natural UO$_2$powder respectively.

  • PDF

ON THE DYNAMICAL STRUCTURE OF THE JET SYSTEM IN THE DISK WITH THE KEPLERIAN ROTATION (회전 원반계 내 제트 현상의 역학적 구조)

  • 정경숙;최윤정;최규홍;최승언
    • Journal of Astronomy and Space Sciences
    • /
    • v.6 no.1
    • /
    • pp.17-28
    • /
    • 1989
  • The classical solar wind theory proposed by Parker(1963) explains well the dynamics of the wind pheonomena such as stellar wind and accretion disk. While the stellar wind system like the solar wind has the spherically symmetric wind structure, there are various jet phenomena which collimate the system into the narrow space. We can find these dynamical structures in SS433, in the optical jet of M87, and around the active galactic nulei. We present the dynamical structure of the jet system in disks, which conserves the angular monetum, with the Keplerian rotation and the strong relation between the geometrical cross section and the physical change of the jet stream on the basis of the hydrodynamic equations.

  • PDF