• 제목/요약/키워드: collimation

검색결과 113건 처리시간 0.021초

동적 시준을 이용한 CT 촬영과 볼록한 관심영역의 영상재구성 (Dynamically Collimated CT Scan and Image Reconstruction of Convex Region-of-Interest)

  • 진승오;권오경
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.151-159
    • /
    • 2014
  • Computed tomography (CT) is one of the most widely used medical imaging modality. However, substantial x-ray dose exposed to the human subject during the CT scan is a great concern. Region-of-interest (ROI) CT is considered to be a possible solution for its potential to reduce the x-ray dose to the human subject. In most of ROI-CT scans, the ROI is set to a circular shape whose diameter is often considerably smaller than the full field-of-view (FOV). However, an arbitrarily shaped ROI is very desirable to reduce the x-ray dose more than the circularly shaped ROI can do. We propose a new method to make a non-circular convex-shaped ROI along with the image reconstruction method. To make a ROI with an arbitrary convex shape, dynamic collimations are necessary to minimize the x-ray dose at each angle of view. In addition to the dynamic collimation, we get the ROI projection data with slightly lower sampling rate in the view direction to further reduce the x-ray dose. We reconstruct images from the ROI projection data in the compressed sensing (CS) framework assisted by the exterior projection data acquired from the pilot scan to set the ROI. To validate the proposed method, we used the experimental micro-CT projection data after truncating them to simulate the dynamic collimation. The reconstructed ROI images showed little errors as compared to the images reconstructed from the full-FOV scan data as well as little artifacts inside the ROI. We expect the proposed method can significantly reduce the x-ray dose in CT scans if the dynamic collimation is realized in real CT machines.

진단방사선 일반촬영에서의 X-ray Beam Collimator 사용 전국 실태조사 (Nationwise Survey of the X-ray Beam Collimator Utilization in General Diagnostic Radiograph)

  • 김지혜;성동욱;김정욱;신진호;이순근;정경일;엄종권;이기남;성호진;김윤현;김혁주
    • 한국의학물리학회지:의학물리
    • /
    • 제24권2호
    • /
    • pp.119-126
    • /
    • 2013
  • 방사선 검사에서 CR, DR의 도입으로 인해 X-선속 조사야의 사용이 경시되고 있는 실정이다. 일반방사선 검사에서 검사 부위별 조사야를 적절히 사용하고 있는지에 대해 현장 실태 조사와 설문 조사하고, 조사야의 기준의 필요성을 강조하며 표준 조사야를 제시하고자 한다. 서울, 경기도, 전라도, 충청도, 강원도, 부산 지역 총 333개 의료기관을 대상으로 X-선속 조사야의 사용 실태를 현장 조사하여, 검사부위별, 의료기관종별, 영상종류별로 조사야 조절의 사용 여부를 분석하였다. 또한 조사야 조절이 방사선피폭에 미치는 영향과 인식을 평가하기 위해 종합병원 10곳, 병원 10곳, 의원 10곳의 일반촬영실에 근무하는 168명의 방사선사를 대상으로 X-선속 조사야 조절이 환자피폭선량 저감화에 끼치는 영향에 대한 인식, 조사야 조절 방법과 실제 사용하고 있는 검사부위별 X-선속 조사야 크기를 설문 조사하였다. 검사부위별 적합한 조사야을 사용하고 있는 의료기관은 61.3%이었으나, 주요 장기가 밀집된 요추 검사의 경우에는 적합한 사용이 49.9%에 불과하였다. 의료기관종별에서는 종합병원이 약 69%, 영상종류별로 보면 DR을 사용하는 병원의 65.0%에서 적합한 조사야을 사용하였다. 설문 조사에서는 응답자의 97.6%가 조사야 조절이 환자에게 끼치는 선량을 줄일 수 있다고 인식하고 있었으나, 실제로 부위별 X-선속 조사야의 크기를 조절하여 검사하는 경우는 83.3%이었다. 일반방사선 검사에서 적절한 조사야를 사용하는 경우가 실태조사를 통해 낮게 나타났으며 이는 환자에 대한 방사선 피폭선량을 줄이기 위한 노력이 시급히 필요하며, 조사야에 대한 통일된 표준 규격이 필요하여 철저한 교육이 동반되어야 한다.

Correlation Between Collimation-Corrected Peak Luminosity and Spectral Lag of Gamma-ray Bursts in the Source Frame

  • Chang, Heon-Young
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권3호
    • /
    • pp.253-258
    • /
    • 2012
  • We revisit the relation between the peak luminosity $L_{iso}$ and the spectral time lag in the source frame. Since gamma-ray bursts (GRBs) are generally thought to be beamed, it is natural to expect that the collimation-corrected peak luminosity may well correlate with the spectral time lag in the source frame if the lag-luminosity relation in the GRB source frame exists. With 12 long GRBs detected by the Swift satellite, whose redshift and spectral lags in the source frame are known, we computed $L_{0,H}$ and $L_{0,W}$ using bulk Lorentz factors ${\Gamma}_{0,H}$ and ${\Gamma}_{0,W}$ archived in the published literature, where the subscripts H and W represent homogeneous and wind-like circumburst environments, respectively. We have confirmed that the isotropic peak luminosity correlates with the spectral time lag in the source frame. We have also confirmed that there is an anti-correlation between the source-frame spectral lag and the peak energy, $E_{peak}$ (1 + z) in the source frame. We have found that the collimation-corrected luminosity correlates in a similar way with the spectral lag, except that the correlations are somewhat less tight. The correlation in the wind density profile seems to agree with the isotropic peak luminosity case better than in the homogeneous case. Finally we conclude by briefly discussing its implications.

Automatic Multileaf Collimation Quality Assurance for IMRT using Electronic Portal Imaging

  • Jin, Ho-Sang;Jason W. Sohn;Suh, Tae-Suk
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.305-308
    • /
    • 2002
  • More complex radiotherapy techniques using multi leaf collimation(MLC) such as intensity-modulated radiation therapy(IMRT) has been increasing the significance of verification of leaf position and motion. Due to the reliability and robustness, quality assurance(QA) of MLC is usually performed with portal films. However, the advantage of ease of use and capability of providing digital data of electronic portal imaging devices(EPIDs) have attracted many attentions as alternatives of films for routine quality assurance in spite of the concerns about their clinical feasibility, efficacy, and the cost to benefit ratio. In our work, the method of routine QA of MLC using electronic portal imaging(EPI) was developed. The verification of availability of EPI images for routine QA was performed by comparison with those of the portal films which were simultaneously obtained when radiation was delivered and known prescription input to MLC controller. Specially designed test patterns of dynamic MLC were applied to image acquisition. Quantitative off-line analysis using edge detection algorithm enhanced the verification procedure in addition to on-line qualitative visual assessment. In conclusion, the EPI is available enough for routine QA with the accuracy of portal films.

  • PDF

The Image Resolution Compare to Having Lead Plate or Not Lumbar Lateral Projection

  • Kim, Hyun-Soo;Min, Jung-Whan;Dong, Kyung-Rae
    • 대한디지털의료영상학회논문지
    • /
    • 제13권4호
    • /
    • pp.145-151
    • /
    • 2011
  • The purpose of this study is to know some changes of resolution and image if we remove scattered ray using lead plate when doing lumbar lateral projection. Using 3 DR system(2 FD types, 1 CCD type) equipments and 2 film system equipments, we gain the image whether the phantom of abdomen equivalent sticking resolution chart has lead plate or not, whether we do collimation or not. Also, we use ion chamber, measure radiation exposure rate and change to entrance surface dose from it. we gain that images in the greatest condition of taking in clinic. 5 people in this group decoded resolution with our eyes, measured thickness of images and compared them from each equiments. Resolution has difference to size of collimation in DR FD type. Also there is no difference the original image with the new image which we abbreviated mAs. In DR CCD type, resolution didn't have difference whether lead plate is or not and whether we do collimation or not. In film type, existing or nonexisting of lead plate didn't influence on resolution. Lead plate makes the quality of image higher due to reducing scattered ray, it doesn't influence on resolution.

  • PDF

High performance γ-ray imager using dual anti-mask method for the investigation of high-energy nuclear materials

  • Lee, Taewoong;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2371-2376
    • /
    • 2021
  • As the γ-ray energy increases, a reconstructed image becomes noisy and blurred due to the penetration of the γ-ray through the coded mask. Therefore, the thickness of the coded mask was increased for high energy regions, resulting in severely decreased the performance of the detection efficiency due to self-collimation by the mask. In order to overcome the limitation, a modified uniformly redundant array γ-ray imaging system using dual anti-mask method was developed, and its performance was compared and evaluated in high-energy radiation region. In the dual anti-mask method, the two shadow images, including the subtraction of background events, can simultaneously contribute to the reconstructed image. Moreover, the reconstructed images using each shadow image were integrated using a hybrid update maximum likelihood expectation maximization (h-MLEM). Using the quantitative evaluation method, the performance of the dual anti-mask method was compared with the previously developed collimation methods. As the shadow image which was subtracted the background events leads to a higher-quality reconstructed image, the reconstructed image of the dual anti-mask method showed high performance among the three collimation methods. Finally, the quantitative evaluation method proves that the performance of the dual anti-mask method was better than that of the previously reconstruction methods.

양전자 방출 단층기

  • 나종범;조장희;노용만
    • 전기의세계
    • /
    • 제38권8호
    • /
    • pp.26-31
    • /
    • 1989
  • PET는 다른 nuclear imaging system(SPECT등)과는 달리 기계적 collimator가 필요없이 전자적 collimation을 할 수 있고 이런 collimation역할로 인하여 SPECT보다 감도(sensitivity)가 좋고 또한 전체 영상영역에 걸쳐 해상도와 감도가 균일하며 감쇄상수의 보정이 쉽다. 기존 X선 CT나 NMR-CT에 비해 해상도와 신호대 잡음비가 떨어짐에도 불구하고 PET 시스템 독특한 장점은 영상 자체가 단순한 영상을 재현하는 것이 아니라 인체내의 생태학적 또는 생리학적인 변화에 대한 정량적 분석이 가능하다는데 있다. 즉, $^{11}$ C, $^{13}$N, $^{15}$ O, $^{18}$ F와 같은 물질은 인체내에 생리적현상과 매우 밀접한 관계를 가지고 있어 이들 물질의 분포나 변화를 제공하는 것은 다른 의료 영상기기와 뚜렷이 구별되는 점이라 할 수 있다. 따라서 앞으로 분해 능력이 2-3mm의 PET시스템의 개발은 임상은 물론 의료연구용으로 매우 유용할 것이며 종래의 NMR과 X선 CT 와는 다른 보완적인 정보를 제공하는 영상시스템으로써 의료산업계의 발전에 크게 기여를 할 것이라고 본다.

  • PDF