• Title/Summary/Keyword: collection efficiency

검색결과 971건 처리시간 0.03초

주방환기용 그리스 필터의 형상설계에 관한 수치해석 (A Numerical Study on the Design of a Grease Filter for Kitchen Ventilation)

  • 김기정;배귀남;김영일;허남건
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.619-629
    • /
    • 2003
  • A grease filter is used to remove grease generated from a cooking appliance in a kitchen. Since the inertial impaction is a dominant particle removal mechanism of the grease filter, the performance of the filter is greatly affected by the geometry. This numerical study has been conducted to investigate the effect of geometry on the performance of grease filters for four models having nominal flowrate of 100 m$^3$/h. Four models were designed by changing the shape of impaction surface, the length of eyelid, and the number of eyelids of the grease filter. The flow field and particle trajectories in the grease filter with a flow chamber were simulated using the commercial code of STAR-CD. The difference of air velocity and pressure distributions among four models was discussed in detail. The collection efficiency curves and the pressure drops of four models were also compared. It was found that the grease filter model with flat top surfaces shows highest performance among four models, having high particle collection efficiency and relatively low pressure drop. The cutoff diameter of this model representing 50-% collection efficiency is about 7.1 ${\mu}{\textrm}{m}$ for water droplets at 100 m$^3$/h.

석회석 슬러리 입자 제거를 위한 전기집진기 포집효율 평가 (Evaluation of Collection Efficiency of Electrostatic Precipitator for Removing Limestone Slurry Particles)

  • 이기혁;김문원;류태우;육세진
    • 한국입자에어로졸학회지
    • /
    • 제15권2호
    • /
    • pp.57-65
    • /
    • 2019
  • Recently, there has been much research on the effect of fine dust on human body with increasing interest in the fine dust. Thermal power plant, which is considered as one of the main sources of fine dust, is reported to be responsible for 14% of the total amount of domestic fine dust in the Republic of Korea. Therefore, dust collecting devices in the thermal power plant need to be improved. In this study, the electrostatic precipitator (ESP) was considered to substitute for a mist eliminator used in flue gas desulfurization facility. By considering real situation in the flue gas desulfurization facility, the collection efficiency of the ESP was evaluated by using the sprayed limestone slurry particles. The collection efficiency of the ESP was higher than that of the mist eliminator, showing the possibility of replacing the mist eliminator with the ESP in flue gas desulfurization facility.

Mud handling system 내 cyclone separator의 집진효율 추정을 위한 공기-분체의 CFD 시뮬레이션 (CFD Simulation of Air-particle Flow for Predicting the Collection Efficiency of a Cyclone Separator in Mud Handling System)

  • 전규목;박종천
    • 한국해양공학회지
    • /
    • 제33권1호
    • /
    • pp.42-49
    • /
    • 2019
  • Drilling mud was used once in the step of separating the gas and powder they were transported to a surge tank. At that time, the fine powder, such as dust that is not separated from the gas, is included in the gas that was separated from the mud. The fine particles of the powder are collected to increase the density of the powder and prevent air pollution. To remove particles from air or another gas, a cyclone-type separator generally can be used with the principles of vortex separation without using a filter system. In this study, we conducted numerical simulations of air-particle flow consisting of two components in a cyclone separator in a mud handling system to investigate the characteristics of turbulent vortical flow and to evaluate the collection efficiency using the commercial software, STAR-CCM+. First, the single-phase air flow was simulated and validated through the comparison with experiments (Boysan et al., 1983) and other CFD simulation results (Slack et al., 2000). Then, based on one-way coupling simulation for air and powder particles, the multi-phase flow was simulated, and the collection efficiency for various sizes of particles was compared with the experimental and theoretical results.

자동차 브레이크 미세먼지 포집을 위한 미니 사이클론의 난류모델에 따른 포집효율 변화 (Variation of Collection Efficiency with Turbulence Model in a Mini Cyclone for Collecting Automobile Brake Fine Dust)

  • 한동연;이영림
    • 한국기계가공학회지
    • /
    • 제20권3호
    • /
    • pp.47-52
    • /
    • 2021
  • Fine dust generated from vehicle brakes accounts for a significant amount of fine dust from non-exhaust system. Since such brake fine dust contains a large number of heavy metal components that are fatal to the human body, a device capable of collecting them needs to be developed. A mini cyclone, one of the devices that can effectively collect fine dust, has the advantage of relatively simple shape and high collection efficiency. Therefore, in this study, the collection efficiency of the mini-cyclone was numerically analyzed using CFD in order to find out whether such a mini-cyclone is suitable for collecting brake fine dust. As a result, the cut-off diameter was predicted to be about 1.5㎛, which means that the particle trapping load of the filter can be drastically reduced. Therefore, there is a possibility that the mini-cyclone can be used to collect fine dust from disc brakes.

Improving light collection efficiency using partitioned light guide on pixelated scintillator-based γ-ray imager

  • Hyeon, Suyeon;Hammig, Mark;Jeong, Manhee
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1760-1768
    • /
    • 2022
  • When gamma-camera sensor modules, which are key components of radiation imagers, are derived from the coupling between scintillators and photosensors, the light collection efficiency is an important factor in determining the effectiveness with which the instrument can identify nuclides via their derived gamma-ray spectra. If the pixel area of the scintillator is larger than the pixel area of the photosensor, light loss and cross-talk between pixels of the photosensor can result in information loss, thereby degrading the precision of the energy estimate and the accuracy of the position-of-interaction determination derived from each active pixel in a coded-aperture based gamma camera. Here we present two methods to overcome the information loss associated with the loss of photons created by scintillation pixels that are coupled to an associated silicon photomultiplier pixel. Specifically, we detail the use of either: (1) light guides, or (2) scintillation pixel areas that match the area of the SiPM pixel. Compared with scintillator/SiPM couplings that have slightly mismatched intercept areas, the experimental results show that both methods substantially improve both the energy and spatial resolution by increasing light collection efficiency, but in terms of the image sensitivity and image quality, only slight improvements are accrued.

Wave plate 습분제거기의 형상 변경을 통한 성능 개선 (Performance improvement of wave plate mist eliminator through geometry modification)

  • 노정훈;조민철;이승종
    • 한국입자에어로졸학회지
    • /
    • 제18권4호
    • /
    • pp.97-107
    • /
    • 2022
  • The geometry of popular wave plate type mist eliminator for the wet flue gas desulfurization process was improved, fabricated, and experimentally evaluated. A Mist eliminator is a type of inertial particle collector which collection efficiency is proportional to the velocity of the gas phase. However, as the amount of re-entrainment is also proportional to the gas phase velocity, there is a limitation for the gas phase flow rate. Re-entrainment is one of the most important issues in a mist eliminator and is likely to occur as the input of the liquid phase and flow rate of the gas phase increase. In order to resolve this problem, the projection angle of the improved mist eliminator is set to 30° from the conventional one while maintaining the cross-section. With low flow rate conditions, the modified mist eliminator showed a similar pressure drop and overall collection efficiency. However, with conditions in which re-entrainment is obviously occurring, the modified mist eliminator showed better performance in draining droplets than the conventional one. As a result, the modified mist eliminator showed higher overall collection efficiency.

공기조화기 장착용 축상유입식 싸이클론의 입자제거효율에 대한 실험적 연구 (Experimental Study on Particle Collection Efficiency of Axial-flow Cyclone in Air Handling Unit)

  • 김세영;권순박;박덕신;조영민;김진호;김명준;김태성
    • 한국대기환경학회지
    • /
    • 제27권3호
    • /
    • pp.272-280
    • /
    • 2011
  • A novel particle removal system for air handling unit (AHU) of subway station was evaluated experimentally. The novel system was designed in order to minimize the maintenance cost by applying axial-flow cyclones. The system consists of multiple cyclone units and dust trap. Based on our previous numerical study, it was found to be effective for removal $1\sim10{\mu}m$ sized dust particles. In this study, we manufactured the mock-up model and evaluated the model experimentally. Liquid and solid test particles were generated for evaluating collection efficiency of the system and the pressure drop was monitored. The collection efficiency was varied from 41.2% to 85.9% with increasing the sizes of particle from 1 to $6.5{\mu}m$ by particle count ratio of inlet and outlet. The pressure drop was maintained constant less than $20mmH_2O$. In addition, the collection efficiency was estimated by total mass for solid test particles. It was found that the collection efficiency was 65.7% by particle mass ratio of inlet and outlet. It shows that present system can replace current pre-filters used in subway HVAC system for removing particulate matters with minimal operational cost.

고효율 사이클론의 집진효율에 관한 연구 (A Study of High Particle Collection Efficiency of Cyclone)

  • 정진도;이상권
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2227-2232
    • /
    • 2003
  • For a reasonable analysis of grade efficiency of cyclone separator, in-line measurements of particle size and particle concentration are needed. The purpose of this study is to define the correlation of measurement data and to measure grade efficiency and pressure drop. The authors adapted that the grade efficiency could be calculated directly from the counted particle numbers. The problem of collection efficiency calculation was different from counting rate of aerosol counters under the same conditions. It is important factor to use the rate of the particle counters to obtain reliable results. Therefore, the authors should use and calculate compensation factor considering sensitivity of aerosol counters, gas velocity and concentration affect higher 30% than originally measured grade efficiency. As the pressure drop and grade efficiency increase, as flow rate increase and then also pressure drop and grade efficiency increase.

  • PDF

Recent Research and Development on Aerosol Cyclones-Review

  • Lee, K.W.;Kim, H.T.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제16권E호
    • /
    • pp.59-68
    • /
    • 2000
  • In this paper Various aerosol cyclones that are developed recently form Kwangju Institute of Science and Technology(KJIST) for increasing collection efficiency or for decreasing pressure drop are reviewed. For the first time, new sets of experimental data are reported on the particle collection efficiency of cyclones with modified surface bodies namely, spiral guide body, circumferential groove body, and vertical groove body. Multi-cylinder cyclones by adding one or two additional cylindrical walls into the conventional cyclone are also described. Ad an attempt to increase the collection efficiency of small particles, electrocyclone using an externally applied electric field was designed and operated. In addition, factors affecting the cyclone performance were studied including flowrate, body and outlet sizes, cyclone dust outlet, and gas property.

  • PDF

Brownian Dynamics 를 이용한 입자 포집 과정 및 여과 성능 해석 (Analysis of Filtration Performance by Brownian Dynamics)

  • 방종근;윤웅섭
    • 대한기계학회논문집B
    • /
    • 제33권10호
    • /
    • pp.811-819
    • /
    • 2009
  • In the present study, deposition of discrete and small particles on a filter fiber was simulated by stochastic method. Trajectory of each particle was numerically solved by Langevin equation. And Lattice Boltzmann method (LBM) was used to solve flow field around the filter collector for considering complex shape of deposit layer. Interaction between the flow field and the deposit layer was obtained from a converged solution from an inner-loop calculation. Simulation method is properly validated with filtration theory and collection efficiency due to different filtration parameters are examined and discussed. Morphology of deposit layer and its evolution was visualized in terms of the particle size. The particle loaded effect on collection efficiency was also discussed.