• Title/Summary/Keyword: collecting cell

Search Result 109, Processing Time 0.027 seconds

Particle Charging and Collection in Two-Stage, Parallel-Plate Electrostatic Precipitators (2단 평행판 정전식 집진기에서의 입자하전 및 포집)

  • 오명도;유경훈;이준식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.2
    • /
    • pp.432-445
    • /
    • 1994
  • From a theoretical analysis point of view, the 2-stage precipitator is decomposed into two units: charging cell and collecting cell. Collection efficiency predictions of the two-stage parallel-plate electrostatic precipitator have been performed theoretically incorporating with the charging and the collecting cells. Particle trajectorise passing the charging cell have been modeled as a simple one. Particle charge distribution at the outlet of the charging cell is calculated through integration of the present unipolar combined charging rate along the entire particle trajectory, and average charge of particles at the outlet of the charging cell is obtained from the particle charge distribution. As for the collecting cell, the diminution of particle concentration along the longitudinal direction of the collecting cell is investigated considering the conventional Deutsch's theory and the laminar theory. One should note that the collection efficiency formula derived is based on monodisperse aerosols. It has been confirmed through the analysis that predictions of particle charge by applying White's unipolar diffusion charging theory overpredict actual cases in the continuum regime, while predictions by Fuch's unipolar diffusion charging theory indicate the reasonable result in the same regime. Theoretical predictions of collection efficiency are also compared with the available experimental results. Comparisons show that the experimental results are consistently located in the collection efficiency region bounded by the two limits, the Deutsch and the laminar collection efficiencies. Finally design parameters of the 2-stage electrostatic precipitator have been investigated systematically through the one-variable-at-a-time method in terms of collection efficiency. Applied voltages on the corona wire of the charging cell and the plate of the collecting cell, and the average air velocity have been selected as the design parameters.

Effects of the Block Distance of Collecting Plate and Particle Size on the particle Deposition Efficiency in the Two-Stage Electrostatic Precipitator (2단식 전기집진기의 집진판 블록간격 및 입자크기가 입자의 부착효율에 미치는 영향)

  • 박청연
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.2
    • /
    • pp.165-178
    • /
    • 2000
  • In this study the effects of block distance have been investigated on the particle deposition efficiency in the collecting cell of two-stage electrostatic precipitator by numerical analysis. Particle trajectories have been changed by the electrostatic and inertial force of particle with the inlet velocity electrostatic number and particle diameter. The total deposition efficiency has a minimum value by the interaction between the effect of particle inertial force and electrostatic force in the collecting cell. The increase of block distance makes the total deposition efficiency decrease under the range of the particle size which has the minimum deposition efficiency. However beyond the range of particle size which has minimum deposition efficiency total deposition efficiency has no trend with the variation of block distance.

  • PDF

Effects of the Block Arrangement on the Collection Efficiency in the Two-Stage Electrostatic Precipitator with Charging Plate (평판형 방전판을 갖는 2단식 전기집진기의 집진판 블록배열이 집진효율에 미치는 영향)

  • 박성호;박청연;김태권
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.6
    • /
    • pp.641-652
    • /
    • 2000
  • The effect of block arrangement has been investigated on the particle deposition in the specified collecting cell of two-stage electrostatic precipitator by numerical analysis. Recirculation zone existed at the downstream of the block in the collecting cell, and the particles entering the recirculation zone were deposited on the collecting plate. Particle trajectory and deposition had considerably different phenomenon according to electrostatic and inertial effect, which depended on inlet mean velocity, electrostatic number, and particle diameter in the collecting cell. The total collection efficiency reached a minimum value through an interaction of electrostatic and inertial effect. In the computational domain, total collection efficiency for the case of two blocks in the computational domain was more than that of one block at the relative small electrostatic number. However as the block distance and inertial effect increased, the difference between the collection efficiency of two cases decreased. In the range of relatively small particle size total collection efficiency was always superior to particle collection efficiency that was predicted by Deutsch equation.

  • PDF

Upregulation of aquaporin 2 and aquaporin 4 in the water-deprived mongolian gerbil (Meriones unguiculatus) kidney (절수시 Mongolian gerbil (Meriones unguiculatus) 콩팥의 Aquaporin 2, Aquaporin 4 발현변화)

  • Song, Ji-Hyun;Kwon, Jin-Seuk;Kim, Yong-Hwan;Park, Yong-Deok;Han, Ki-Hwan;Ryu, Si-Yun;Jung, Ju-Young
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.4
    • /
    • pp.363-370
    • /
    • 2007
  • Mongolian gerbil (Meriones unguiculatus) has been as an model animal for studing the neurological disease such as stroke and epilepsy because of the congenital incompleteries in Willis circle, as well as the investigation of water metabolism because of the long time-survival in the condition of water-deprived desert condition, compared with other species animal. Aquaporin 2 (AQP2) expressed at the surface of principal cells in collecting duct results from an equilibrium between the AQP2 in intracellular vesicles and the AQP2 on the plasma membrane. Aquaporin 4 (AQP4), which is expressed in cell in a wide range of organ, is also present in the collecting duct principal cells where this is abundant in the basolateral plasma membranes and represent potential exit pathways from the cell for water entering via AQP2. In this research, we divide 3 groups of which each group include the 5 animals. In the study of 7 or 14 days water restricted condition, we investigated the AQP2 and AQP4 by using a quantitative immunohistochemistry in the kidney. The results obtained in this study were summarized as followings. AQP2 is abundant in the apical plasma membrane and apical vesicles in the collecting duct principal cell and at rare abundance in connecting tubules. In the water-deprived Mongolian gerbil kidney, expression of AQP2 was continuosly increased in the cortical collecting duct and inner medullary collecting duct. This increase was both the apical region and cytoplasm. AQP4 is mainly expressed in the inner medulla, although some expression is also noted in the more proximal segment. In the water-deprived Mongolian gerbil kidney, AQP4 was also increased in the inner medullary collecting duct. Immunoactivity was increased in entire inner medullary collecting duct and newly detected in cytoplasm of principal cell. These findings suggest that increased levels of AQP2 and AQP4 in the cortical and inner medulalry collecting duct may play a important role for maintain fluid balance in the water-deprived kidney.

Collection Efficiency of Particles with Effect of Blocks in the Two-Stage Electrostatic Precipitator (2단식 전기집진기 내에서 블록의 영향에 따른 입자의 집진효율)

  • 박성호;박청연
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.217-218
    • /
    • 2000
  • 유해입자 배출 저감을 위한 대기오염 제어장치로는 필터(filter), 관성장치(inertialdevices), 침전조(settling), 스크루버(scrubber), 전기집진기(ElectroStatic Precipitator, ESP)등이 있다. 이 중, 정전기력을 이용한 전기집진기는 대전과정과 집진과정이 동일한 곳에서 이루어지는 1단식(one-stage)과 독립적으로 이루어지는 2단식(two-stage)으로 분류되며, 2단식의 경우, 대전부(charging section)와 집진부(collecting section)는 몇 개의 대전셀(charging cell)과 집진셀(collecting cell)들로 구성되어져 있다. (중략)

  • PDF

Urothelial Carcinoma of the Renal Pelvis with Synchronous Ipsilateral Collecting Duct Carcinoma: Two Case Reports (동측 신장에서 발생한 동시성 집합관세포암종과 요로상피세포암: 2예 보고)

  • Sang Bin Bae;Seong Kuk Yoon;Seo-hee Rha
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.222-229
    • /
    • 2024
  • Synchronous renal malignancies are seldom encountered or diagnosed post-renal resection. A combination of renal cell carcinoma (RCC) and urothelial carcinoma (UC) is most commonly reported. Typically, the RCC subtype is clear-cell RCC; however, a combination of collecting duct carcinoma (CDC) and UC has rarely been reported in the existing literature. Here, we present two cases of synchronous renal malignancy, specifically a combination of CDC and UC, in the ipsilateral kidney.

Numerical Analysis on Performance Changes of the Tubular SOFCs according to Current Collecting Method (전류집전 방법에 따른 원통형 고체산화물 연료전지의 성능 변화 수치해석)

  • Yu, Geon;Park, Seok-Joo;Lee, Jong-Won;Lee, Seung-Bok;Lim, Tak-Hyoung;Song, Rak-Hyun;Shin, Dong-Ryul;Kim, Ho-Young
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.2
    • /
    • pp.129-138
    • /
    • 2011
  • Performance changes of an anode-supported tubular SOFC including current collectors are analyzed at different current collecting methods using numerical simulation. From the two dimensional numerical model of the solid oxide fuel cell with nickel felts as anodic current collectors and silver wires as cathodic ones, the performance curves and the distributions of temperature, concentration, current density are obtained. Also, the voltage loss of the cell is divided into three parts: activation loss, concentration loss and ohmic loss. The results show that the performance change of the cell is dominantly influenced by the ohmic loss. Although the temperature and concentration distributions are different, the total activation loss and concentration loss are nearly same. And the ohmic loss is divided into each parts of the cell components. The ohmic loss of the anodic current collectorreaches about 60~80% of the cell's total ohmic loss. Therefore, the reduction of the ohmic loss of the anodic current collector is very important for stack power enhancement. It is also recommended that the load should be connected to the both ends of the anodic current collector.

Fabrication and Application of Micro Polymer Chip Platform for Rare Cell Sample Preparation (희귀 세포 샘플 준비를 위한 마이크로 폴리머 칩 플랫폼 제작 및 활용)

  • Park, Taehyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.3
    • /
    • pp.217-222
    • /
    • 2018
  • In this paper, a new micro polymer chip platform and protocol were developed for rare cell sample preparation. The proposed platform and protocol overcome the current limitation of the dilution method which is based on statistics and the FACS method which expensive and requires fluorescence staining. It allows collecting exact number of target cells simply and selectively because the cells are visually confirmed during the collecting process. The collected cells can be transported or spiked into a desired locations, such as a microchamber, without cell loss. This research may applicable not only to a rare cell sample preparation for Lab on a Chip cancer diagnosis, but also to a single/double/multiple cell sample preparation for a cell analysis field. To verify this platform and protocol, five human breast cancer cells (MCF-7) were collected and transported into a hemocytometer chamber.

Constructing a Standard Clinical Big Database for Kidney Cancer and Development of Machine Learning Based Treatment Decision Support Systems (신장암 표준임상빅데이터 구축 및 머신러닝 기반 치료결정지원시스템 개발)

  • Song, Won Hoon;Park, Meeyoung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_2
    • /
    • pp.1083-1090
    • /
    • 2022
  • Since renal cell carcinoma(RCC) has various examination and treatment methods according to clinical stage and histopathological characteristics, it is required to determine accurate and efficient treatment methods in the clinical field. However, the process of collecting and processing RCC medical data is difficult and complex, so there is currently no AI-based clinical decision support system for RCC treatments worldwide. In this study, we propose a clinical decision support system that helps clinicians decide on a precision treatment to each patient. RCC standard big database is built by collecting structured and unstructured data from the standard common data model and electronic medical information system. Based on this, various machine learning classification algorithms are applied to support a better clinical decision making.