• 제목/요약/키워드: collagenase activity

검색결과 240건 처리시간 0.028초

사람 연골하골 중간엽 줄기세포의 효율적인 골형성 유도 (Induction of Effective Osteogenesis by Mesenchymal Stem Cells from the Human Subchondral Bone)

  • 허정은;조윤제;유명철;백용현;이재동;최도영;박동석
    • Journal of Acupuncture Research
    • /
    • 제23권5호
    • /
    • pp.69-77
    • /
    • 2006
  • Background : Mesenchymal stem cells (MSCs) are present in most of the tissue matrix, taking part in their regeneration when injury or damage occurs. The aim of this study was to investigate the presence of cells with pluripotential characteristics in human subchondral bone and the capacity of these cells to differentiate to osteoblast. Methods : Human subchondral bone were digested with collagenase. Isolated cells were cultured with a-MEM, 15% FBS, 10-8M dexamethasone and 50 ng/mL ascoric acid. Cells from 0 day(isolated cells), 7 day (first subculture) and 14 days (third subculture) were used to carry out phenotypic characterization experiments flowcytometry analysis with 11 monoclonal antibodies) and osteogenic differentiation experiments. Osteogenic differentiation of cells was assessment by quantification of bone extracellular matrix components by following analysis: alkaline phosphatase(ALP) stains to detect ALP activity, RT-PCR and western blot to detect osteocalcin (OCN), osteopontin (OPN) and type I collagen(Col I), and Alizarin red stains to detect calcium deposition. Results : Flowcytometry analyses showed that in our population more than 98% of cells were positive for MSC markers: SH-2(CD105, 99%), CD29 (95%), CD73 (95%). Cells were negative for hematopoietic markers (CD11b, CD34, and CD45). Furthermore, cells showed positive stain to multipotent markers such as CDl17 (c-kit) (15.1%), and CD166 (74.9%), and cell adhesion molecules such as CD54 (78.1%) and CD106 (63.5%). The osteogenic specific marker analyses showed that the culture of these cells for 7 and 14 days stimulates ALP, OCN, OPN and Col I synthesis by RT-PCR and Western blot analysis. Also, after 14 days in the culture of MSCs induces mineralization by Arizarin red stain. Conclusion : In this work, we demonstrated a new and efficient method for osteoblastic differentiation of human subchondral bone stem cells. As MSCs takes part in reparative processes of adult tissues, these cells could play an important role in osteogenesis.

  • PDF

Transcription factor EGR-1 transactivates the MMP1 gene promoter in response to TNFα in HaCaT keratinocytes

  • Yeo, Hyunjin;Lee, Jeong Yeon;Kim, JuHwan;Ahn, Sung Shin;Jeong, Jeong You;Choi, Ji Hye;Lee, Young Han;Shin, Soon Young
    • BMB Reports
    • /
    • 제53권6호
    • /
    • pp.323-328
    • /
    • 2020
  • Matrix metalloproteinase 1 (MMP-1), a calcium-dependent zinccontaining collagenase, is involved in the initial degradation of native fibrillar collagen. Tissue necrosis factor-alpha (TNFα) is a pro-inflammatory cytokine that is rapidly produced by dermal fibroblasts, monocytes/macrophages, and keratinocytes and regulates inflammation and damaged-tissue remodeling. MMP-1 is induced by TNFα and plays a critical role in tissue remodeling and skin aging processes. However, the regulation of the MMP1 gene by TNFα is not fully understood. We aimed to find additional cis-acting elements involved in the regulation of TNFα-induced MMP1 gene transcription in addition to the nuclear factor-kappa B (NF-κB) and activator protein 1 (AP1) sites. Assessments of the 5'-regulatory region of the MMP1 gene, using a series of deletion constructs, revealed the requirement of the early growth response protein 1 (EGR-1)-binding sequence (EBS) in the proximal region for proper transcription by TNFα. Ectopic expression of EGR-1, a zinc-finger transcription factor that binds to G-C rich sequences, stimulated MMP1 promoter activity. The silencing of EGR-1 by RNA interference reduced TNFα-induced MMP-1 expression. EGR-1 directly binds to the proximal region and transactivates the MMP1 gene promoter. Mutation of the EBS within the MMP1 promoter abolished EGR-1-mediated MMP-1 promoter activation. These data suggest that EGR-1 is required for TNFα-induced MMP1 transcriptional activation. In addition, we found that all three MAPKs, ERK1/2, JNK, and p38 kinase, mediate TNFα-induced MMP-1 expression via EGR-1 upregulation. These results suggest that EGR-1 may represent a good target for the development of pharmaceutical agents to reduce inflammation-induced MMP-1 expression.

리장 설차 (Nekemias grossedentata )의 화장품적 적용 효능 분석 (Analysis on the Efficacy of Cosmetic Application of Lijang Snow Tea (Nekemias grossedentata))

  • 문영;이설훈
    • 대한화장품학회지
    • /
    • 제47권4호
    • /
    • pp.281-287
    • /
    • 2021
  • 중국 운남성 리장지방에 자생하는 리장설차의 화장품적 적용 가능성을 분석 하였다. 우선 리장 설차의 DNA 분석을 통해서 Nekemias grossedentata (N. grossedentata) 라는 종을 확인한 후, 대표적인 차인 녹차와 각 효능분석에 대표적인 대조군을 사용하여 실험하였다. 먼저 리장 설차는 70% (v/v)에탄올 수용액으로 추출하였다. 리장설차 추출물내의 폴리 페놀함량 (gallic acid equivalent, 23.9 ± 3.2 mg/mL)은 녹차(16.4 ± 2.3 mg/mL)보다 많은 양을 포함 하고 있었다. 한편 추출물내의 고형분을 기준으로 항산화 활성(라디칼소거, IC50 104 ㎍/mL), Tyrosinase 효소 억제 활성(미백, IC50 40.7 ㎍/mL), 대장균 성장 억제 활성(방부: IC50 2.85 mg/mL)을 분석한 결과 녹차(항산화, 라디칼 소거, IC50 234 ㎍/mL) 보다 우수한 것 확인 하였다. 또한 항산화 (비타민C, IC50 108 ㎍/mL), 미백 (비타민C: IC50 80 ㎍/mL), 방부(메틸 파라벤: IC50 4.35 mg/mL)등의 기존에 사용되던 활성물질과도 유사한 효능을 보여 주었. 그러나 콜라게네이즈 억제 활성(주름) 은 녹차가 더 우수한 것으로 나타났다. 이를 통해 리장 설차의 화장품적 적용 가능성이 높은 것을 확인할 수 있었다.

향나무추출물의 광손상으로부터 피부세포 보호와 자극완화 효과에 대한 연구 (Protection of UV-derived Skin Cell Damage and Anti-irritation Effect of Juniperus chinensis Xylem Extract)

  • 김진화;박성민;심관섭;이범천;표형배
    • 대한화장품학회지
    • /
    • 제30권1호
    • /
    • pp.63-71
    • /
    • 2004
  • 태양광선과 산소는 피부세포에 자유라디칼(free radical)과 활성산소종(Reactive oxygen species, ROS)을 생성시켜 DNA의 손상과 세포막 지질의 과산화를 유발한다. 또한 콜라겐과 같은 세포 외 기질을 파괴하는데 관여하는 효소(matrix metallo-proteinhse, MMPs)의 발현에 영향을 주어, 결합조직을 손상시키며, 피부 염증을 유발시켜 조직을 파괴하고 노화를 가속화시킨다. 본 연구는 자외선과 SLS에 의한 피부손상에 대한 향나무추물물의 피부 보호 효과에 대한 것이다. 실험 결과 프리라디칼 및 슈퍼옥사이드 라디칼 소거 효과가 우수하게 나타났으며, 피부 콜라겐과 같은 메트릭스를 분해하는 효소인 MMP-1의 활성 및 발현 저해 효과는 섬유아세포에서 UVA 조사에 의한 실험에서 우수하게 나타났으며, 피부세포 배양액에 대해 zymography를 실시하여 활성이 감소됨을 확인하였다. 피부 각질형성세포에서 자외선에 의해 유도된 염증관련 사이토카인인 인터루킨 6의 발현량 실험에서도 무처리군에 비해 향나무추출물이 인터루킨 6를 30% 정도 저해효과가 나타났으며, 염증반응 중 cyclooxygenase (COX)에 의한 경로에서 생성되는 프로스타글란딘 E$_2$의 생성량도 감소시켰다. 사람 피부에서 SLS (0.5%)첩포로 유발된 자극성 피부염의 항염증 효과 평가 시 SLS에 의해 유발되는 자극정도가 피검자의 피부상태에 따라 다양하게 나타났으며, 향나무추출물 함유 에멀젼 제품 도포 실험에서는 피부 홍반 완화 효과와 피부장벽 회복 효과가 우수하게 나타났다. 따라서 향나무추출물은 자외선 조사 및 SLS에 의한 피부손상에 대한 보호 효과를 가진 화장품에서 우수한 소재로 적용될 수 있다. 녹두추출물을 화장품에 사용하였을 경우 우수한 항자극 효과를 보임을 확인하였다.완화시키는데 기여하였다. 이러한 결과를 종합하여 한국에서 삼림쇠퇴를 유발할 수 있는 스트레스요인들의 잠재적 상호작용을 모식화하였다. 나아가 그것을 완화할 수 있는 복원방안을 토양개량과 식생복원의 측면에서 제시하였다. mg/l)치 농도가 높을지라도 이것이 낮은 cinnamic acid와 protocatechuic acid에서 현저한 억제현상을 보였다. 서양등골나물 임상의 토양보다 서양등골나물이 분포하지 않는 토양의 중금속 함량이 전반적으로 높았다. 특히 Al, Fe 및 Mn의 함량이 높았으며 이들 중금속은 total phenolic compound 함량이 높은 잎에 대부분이 축적되었다." separating himself from the real world. Thirdly, The nature of "Gang-Ho" is 'absence of worldly desire' and 'cordiality' that one could be deserved his diligency becoming a part of the harmonious idealistic living place. Fourthly, on the character of story teller. Originally he is a incomer of "Gang-Ho" from real world. so that reason, he is showing dualism not to deny the loyalty oath to his king, while he intends to satisfy with the life in "Gang- Ho" separating himself from real world. As

약용식물추출물의 광보호 효과와 항염증 효과 연구 (Photoprotection and Anti-inflammatory Effects of Chinese Medical Plants)

  • Jin-Hwa, Kim;Sung-Min, Park;Gwan-Sub, Sim;Bum-Chun , Lee;Hyeong-Bae, Pyo
    • 대한화장품학회지
    • /
    • 제30권2호
    • /
    • pp.227-233
    • /
    • 2004
  • 자외선이 피부에 지속적으로 조사되면 썬번, 염증, 광노화와 같은 다양한 부작용이 생기게 된다. 따라서 광손상에 대한 보호작용은 점점 중요성이 인식되고 있으며, 천연 식물추출물에서 자외선에 대한 광보호효과가 있는 안전하고 효과적인 물질개발에 대한 연구가 진행되고 있다. 본 연구는 자외선에 의해 유도된 피부손상에 대한 보호효과가 우수한 천연식물추출물에 대한 것이다. 향나무, 능소화, 비자추출물에서 자외선에 의해 생성되는 라디칼에 대한 항산화효과, MMP 발현 및 활성 저해, 염증관련 사이토카인인 인터루킨 1알파, 6, 프로스타글란딘 E$_2$ 생성저해효과 등으로 피부세포보호 효과를 연구하였다. 실험결과 천연추출물 중 향나무추출물과 능소화추출물이 프리라디칼 및 슈퍼옥사이드 라디칼 소거효과가 우수하게 나타났으며 피부 콜라겐과 같은 메트릭스를 분해하는 효소인 MMP-1의 활성 및 발현 저해효과는 섬유아세포에서 UVA 조사에 의한 실험에서 우수하게 나타났으며, 피부세포 배양액에 대해 zymography를 실시하여 활성이 감소됨을 확인하였다. 피부 각질형성세포에서 자외선에 의해 유도된 염증관련 사이토카인인 인터루킨 6의 발현량 실험에서도 무처리군에 비해 향나무추출물이 인터루킨 6을 30% 정도 저해효과가 나타났으며, 염증반응 중 cyclooxygenase(COX)에 의한 경로에서 생성되는 프로스타글란딘 E$_2$의 생성량도 감소시켰다. 사람피부에서 SLS (0.5%) 첩포로 유발된 자극성 피부염의 항염증 효과 평가 시 SLS에 의해 유발되는 자극정도가 피검자의 피부상태에 따라 다양하게 나타났으며, 향나무 추출물 함유 에멀젼 제품 도포 실험에서는 피부 홍반 완화 효과와 피부장벽 회복효과가 우수하게 나타났다. 이상의 결과로 향나무추출물은 자외선 조사 및 SLS에 의한 피부손상에 대한 피부세포보호작용이 우수하여 광노화에 대응하는 자극완화 소재로서의 화장품 응용 가능성을 확인하였다.

지리산오갈피, 가시오갈피, 오갈피나무, 오가나무 추출물의 항염증, 피부장벽개선, 항노화 효능 비교 (Comparison of Anti-inflammatory, Skin Barrier Improvement, and Anti-aging Efficacy of Eleutherococcus divaricatus var. chiisanensis and various Eleutherococcus Genus Extract)

  • 한지원;남보미;이범석;고진아;황지영
    • 대한화장품학회지
    • /
    • 제48권4호
    • /
    • pp.373-383
    • /
    • 2022
  • 활성산소로 인한 염증 유발과 그로 인한 장벽손상은 꾸준히 주름생성의 원인으로 지목되어 왔다. 본 연구에서는 오갈피나무속에 속해있는 지리산오갈피와 가시오갈피, 오갈피나무, 오가나무 4종의 추출물에 대한 항산화, 항염증 및 피부 장벽개선, 항노화 관련 기능성 화장품 소재로서의 활용가치를 검증하고자 유효 지표성분 탐색과 효능 분석을 수행하였다. 먼저, 오갈피나무속 식물인 지리산오갈피와 가시오갈피, 오갈피나무, 오가나무 각각을 50% 에탄올을 용매로 추출, 농축, 동결건조 하여 시료를 제조하였다. 유효 지표성분탐색을 위해 주요 지표 성분인 eleutheroside E와 오갈피나무속에서 주로 검출되는 폴리페놀류 중 chlorogenic acid, caffeic acid 에 대하여 고성능 액체크로마토그래피를 통해 성분 함량을 측정하였으며, 오갈피나무속 중 지리산오갈피에서 eleutheroside E와 chlorogenic acid의 함량이 가장 높은 것을 확인하였다. 항산화활성은 DPPH 라디칼 소거활성이 지리산오갈피에서 가장 높았으며, 항염증 효능의 경우 LPS로 염증이 유발된 대식세포 내 NO 생성 억제 효능은 가시오갈피, 오가나무, 오갈피나무 추출물 100 ㎍/mL에서 각각 25%, 26%, 32% 일 때 지리산오갈피 추출물 100 ㎍/mL는 40% 억제 효능을 보였고 pro-inflammatory cytokine으로 알려진 IL-6 발현 억제 효능은 가시오갈피, 오가나무, 오갈피나무 추출물 100 ㎍/mL 농도에서 각각 20%, 36%, 23% 일 때 지리산오갈피 추출물 100 ㎍/mL는 41% 억제 효능을 보였다. 또한, 지리산오갈피 추출물 100 ㎍/mL에서 피부장벽 관련 인자인 filaggrin, involucrin의 발현이 각각 2.5 배, 1.6 배 증가되었으며, 주름관련 인자인 콜라겐분해효소는 29% 억제 효능을 나타내어 오갈피나무속 4 종 중 지리산오갈피는 피부의 염증 억제와 장벽강화, 주름개선용 화장품소재로써 활용가능하리라 판단된다.

포도전정가지 추출물이 UVB로 유도된 결합 조직 손상에 미치는 피부 보호 효과 (Skin Protection Effect of Grape Pruning Stem Extract on UVB-induced Connective Tissue Injury)

  • 김정희;김극준
    • 생명과학회지
    • /
    • 제28권2호
    • /
    • pp.141-147
    • /
    • 2018
  • 본 연구는 포도수확 후 버려지는 가지를 이용한 포도전정가지 추출물(Grape Pruning Stem Extracts, GPSE)에 함유된 polyphenol류 중 항산화, 항염증, 항암 등의 효과가 있다고 알려진 rutin, procyanidin B3, quercetin, kaempferol의 함량을 분석하고, UVB로 유도된 HR-1 mice의 손상된 피부에 대한 교원섬유, 탄력섬유 파괴억제 효과를 측정하여 기능성 화장품 소재로서의 응용 가능성을 확인하고자 하였다. 포도전정가지에서 polyphenol 성분을 80% EtOH로 추출하고 여과하여 농축한 후, 동결건조하여 $-20^{\circ}C$에 보관하면서 사용하였다. GPSE의 유효성분 함량은 HPLC를 사용하여 분석하였다. 피부손상을 유도하기 위해 UVB를 HR-1 hairless mice에 조사하였고, 손상된 피부에 교원섬유 파괴억제 효과를 보기 위해 Masson's trichrome stain, 탄력섬유 파괴 억제 효과를 보기 위해 Verhoeff's elastic fiber stain, MMP-9 단백 발현을 보기 위해 면역조직화학적 염색을 실시하였다. 본 연구에 사용된 포도전정가지 시료 53 kg에서 EtOH 분획 추출물 2.34 kg을 추출하여 4.42%의 수율 결과를 얻었다. 유효성분 분석결과, procyanidin B3, 0.28 mg/g, rutin 12.81 mg/g, quercetin 0.51 mg/g 및 kaempferol 8.24 mg/g로 나타났다. GPSE와 serum base를 혼합 도포한 그룹에서 UVB에 의한 교원섬유와 탄력섬유를 분해하는 MMP-9 단백발현 결과, 대조군 대비 평균 약 90% 감소 억제하는 효과를 볼 수 있었다. 교원섬유 파괴억제 효과는 모든 농도에서 평균 24%의 억제율과, GPSE와 serum base의 혼합물 농도 2,000 mg/kg 에서 43%로 가장 우수한 교원섬유 파괴억제효과가 나타났으며, 탄력섬유파괴 억제 효과는 모든 농도에서 평균 12%의 억제율과 GPSE와 serum base의 혼합물 농도 1,000 mg/kg에서 35%로 가장 우수한 탄력섬유 파괴 억제 효과가 있는 것으로 나타났다. 이 결과는 GPSE가 진피층의 세포 외 기질에 UVB 조사에 의해 파괴되는 교원섬유, 탄력섬유의 파괴를 억제하는 작용을 한다는 것을 알 수 있었다. 이상의 결과로 포도전정가지로부터 rutin, kaempferol, quercetin, procyanidin B3 등의 폴리페놀성 화합물이 화장품 기초 원료인 serum base에 함유토록 제조된 GPSE 는 교원섬유 파괴 억제, 탄력섬유파괴 억제효과 및 피부손상 기능개선 효과의 결과를 얻을 수 있었다. 본 연구의 의의는 지역포도농가에서 수확 후 버려지는 포도전정가지에서 폴리페놀류와 같은 유효성분을 확보하여 화장품 원료로서의 활용 가치가 높을 것으로 기대된다.

유근피가 골세포의 mineralization, bone morphogenetic protein-2, alkaline phosphatase, type I collagen 및 collagennase-1에 미치는 영향 (Effects of Ulmus davidiana Planch(Ulmaceae) on mineralization, bone morphogenetic protein-2, alkaline phosphatase, type I collagen and collagennase-1 in bone cells)

  • 변유석;윤종화;황민섭;김갑성;조현석
    • Journal of Acupuncture Research
    • /
    • 제22권3호
    • /
    • pp.13-22
    • /
    • 2005
  • 손상된 조직의 보호와 항염증작용이 있는 것으로 알려진 유근피를 수액추출하여 골다공증의 치료에 응용 가능한가를 실험하였다. 이전의 실험에서 유근피 추출액이 파골세포를 함유한 장골세포의 치료를 통해 Cathepsin K를 억제하는 것을 확인 하였었다. 이를 통하여 유근피는 골다공증 치료에서 골재흡수억제제로 서의 prodrug의 역할을 할 수 있음을 시사하였다. 본 실험에서는 MC3T3-El pre-osteoblastic 세포조직을 이용하여 골화를 유발한 상태에서 유근피가 골아세포의 성장과 감작에 대한 것을 in vitro로 연구하였다. 이 결과 유근피는 용량과 시간의존적으로 ALP의 활동을 향상시킴으로써 강화작용이 있음을확인할 수 있었다. 투여량은 최소치 $50{\mu}g/m{\ell}$에서 최대치 $150{\mu}g/m{\ell}$에서 관찰되었다. $100{\mu}g/m{\ell}$ UD에서 bone morphogenetic protein-2의 향상을 관찰할 수 있었으며, MC3T3-El 세포내의 ALP mRNA농도역시 증가 하였다. $60{\mu}g/m{\ell}$ UD에서 Type I collagen mRNA에 대해서 오랜 배양 기간 동안 약간의 증가를 나타내었으나 15-20일 사이의 배양에서는 급격히 유전자 발현을 억제하는 것으로 나타났다. 이러한 결과는 골아 세포의 감작을 통해 유근피가 골대사에 영향을 미침을 시사하는 것이다. 그러므로 추후 연구를 통하여 일반적인 골대사질환에 유근피를 적극적으로 활용할 수 있음을 알 수 있었다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF