• Title/Summary/Keyword: coliform group

Search Result 190, Processing Time 0.031 seconds

A Study on the Drinking Water Quality for Primary Lunch School in Seoul (서울지역 급식 국민학교의 음용수 수질에 관한 연구)

  • 이원묘;이용옥;방형애
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.1
    • /
    • pp.7-20
    • /
    • 1995
  • The aims of this study are to enhance the students' knowledge of the drinking water and its reliability by investigating drinking water situation on the drinking water. The results are as following 1. Status and drinking behavior about school drinking water (1) 97.82% of the schools are using the tap water as the resource of drinking water. (2) 46 schools are in possession of water tank and 18 schools of them are using the water tank as the resource of drinking water. The clearing and sanitization of the tank are carried out once in a year with hypochloronatrium by the low-level officials. (3) 51.28% of the schools are providing the students with drinking water and 75% of them with boiled water. The drinking water supply managers are low-level officials, nurse teachers, and dietitian. 2. Analysis of the drinking water quality (1) Most of the drinking water provided by the school are tap water 35.8%, barely tea 5.85%, filtered water 6.3%, ground water 1.1% and all turned out to be suitable for drinking. (2) The drinking water carried from home turned out to be unsuitable for drinking except pH criterion, especially the test of APC(Aerobic Plate Count) and Coliform group showed worse degree. These results were caused by the hygiene problem and maltreatment in water container.

  • PDF

Survival of Sanitary Indicative Bacteria Inoculated in Fish Muscle Homogenates during Freezing and Frozen Storage (어육에 접종한 위생지표세균의 동결저장중 변화)

  • CHOI Jong Duck;CHANG Dong Suck;KIM Young Man
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.4
    • /
    • pp.356-362
    • /
    • 1986
  • This experiment was designed to evaluate effects of freezing and frozen storage on survival of sanitary indicative bacteria in seafoods. Culture of bacteria such as Escherichia coli type I, Citrobacter freundii type I, Klebsiella aerogenes type I and Streptococcus faecalis was inoculated into homogenates of pollack, shrimp, and sardine frozen in a contact plate freezer at $-40^{\circ}C$ and chest freezer at $-20^{\circ}C$, stored at $-20^{\circ}C$, and then survival of the inoculated bacteria was determined over a period of 95 days. Coliform group was highly sensitive to freezing and frozen storage showing survival of about $2\%$ after 95 days of frozen storage at $-20^{\circ}C$, whereas Streptococcus faecalis was relatively resistant with $20\%$ survival rate. The sanitary indicative bacteria count was rapidly decreased in the early stage of frozen storage revealing 90 to $95\%$ loss of coliform group and 40 to $70\%$ loss in case of Streptococcus faecalis after 10 days storage. In determining recovery rate, most probable number (MPN) method gave more reproducible recovery of the tested strain than did the selected agar plate method.

  • PDF

Microbiological Hazard Analysis for HACCP System Application to Non Heat-Frozen Carrot Juice (비가열냉동 당근주스의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Lee, Ung-Soo;Kwon, Sang-Chul
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.79-84
    • /
    • 2014
  • This study has been performed for about 270 days at analyzing biologically hazardous factors in order to develop HACCP system for the non heat-frozen carrot juice. A process chart was prepared by manufacturing process of raw agricultural products of non heat-frozen carrot juice, which was contained water and packing material, storage, washing, cutting, extraction of the juice, internal packing, metal detection, external packing, storage and consignment (delivery). As a result of measuring Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, Enterohemorrhagic E. coli before and after washing raw carrot, Standard plate count was $4.7{\times}10^4CFU/g$ before washing but it was $1.2{\times}10^2CFU/g$ detected after washing. As a result of testing airborne bacteria (Standard plate count, Coliform group, Yeast and Fungal) depending on each workplace, number of microorganism of in packaging room, shower room and juice extraction room was detected to be 10 CFU/Plate, 60 CFU/Plate, 20 CFU/Plate, respectively. As a result of testing palm condition of workers, as number of Standard plate count, Coliform group and Staphylococcus aureus was represented to be high as $6{\times}10^4CFU/cm^2$, $0CFU/cm^2$ and $0CFU/cm^2$, respectively, an education and training for individual sanitation control was considered to be required. As a result of inspecting surface pollution level of manufacturing facility and devices, Coliform group was not detected in all the specimen but Standard plate count was most dominantly detected in scouring kier, scouring kier tray, cooling tank, grinding extractor, storage tank and packaging machine-nozzle as $8.00{\times}10CFU/cm^2$, $3.0{\times}10CFU/cm^2$, $4.3{\times}10^2CFU/cm^2$, $7.5{\times}10^2CFU/cm^2$, $6.0{\times}10CFU/cm^2$, $8.5{\times}10^2CFU/cm^2$ respectively. As a result of analyzing above hazardous factors, processing process of ultraviolet ray sterilizing where pathogenic bacteria may be prevented, reduced or removed is required to be controlled by CCP-B (Biological) and critical level (critical control point) was set at flow speed is 4L/min. Therefore, it is considered that thorough HACCP control plan including control criteria (point) of seasoning fluid processing process, countermeasures in case of its deviation, its verification method, education/training and record control would be required.

Water Quality Variations due to Tidal Change in the Lower Part of the Nagdong River (조석에 따른 낙동강 하류수질의 변화)

  • KIM Yong-Gwan;CHANG Dong-Suck;MOON Hong-Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.2
    • /
    • pp.109-118
    • /
    • 1985
  • This experiment was carried out to evaluate the water quality in the lower part of the Nagdong river in Korea. Three hundred and sixty water samples were collected from the 15 stations from December 1981 to November 1982 by tide(see Fig.1). Water temperature, pH, chloride ion, salinity, total coliform, fecal coliform, viable cell count and the composition of coliform were observed to evaluate the water quality. The variations of water temperature was ranged from $2.0^{\circ}C\;to\;29.5^{\circ}C$ and as mean value from $15.8^{\circ}C\;to\;18.9^{\circ}C$. The range of pH was 6.00-8.88 and 7.20-7.96 as mean value. The concentration of chloride ion from St. 1 to 5 was higher as 17.51-771 mg/l in flood tide than 13.12-264.58 mg/l in ebb tide. Specially, water quality at St.1 (Samrangjin) which located about 46 km far from Hadan was also influenced by tide. Salinities of water in flood tide were a litte higher ($11.05{\sim}31.08\%0$) than those of in ebb tide ($7.80{\sim}29.28\%0$). Total coliform MPN's ranged from 3.6/100 m/l to 460,000/100ml. The geometric mean value of the upper area (included St. $1{\sim}3$) was $259{\sim}538/100ml$, that of the middle area (included St. $4{\sim}6$) was $1,097{\sim}39,544/100ml$ for it leveled heavy contamination. Specially, in the ebb tide St. 10 was influenced by St. 6 and 7. In the upper area, the geometric mean value of fecal coliform MPN's was $109{\sim}199/100ml$ but in the area in cluded St. 5, 6 and 7 were heavily contaminated by domestic sewage, waste water from the factories area and bird's excrement. Composition of coliform was $17\%$ Escherichia coli group, $33\%$ Citrobacter freundii group, $28\%$ Enterobacter aerogenes group and $21\%$ others. Plate count of samples was varied from <30 to $3.9{\times}10^4/ml$ during the study period.

  • PDF

Chemical and Bacteriological Water Qualify of the Sonakdong River (서낙동강 강수의 화학적${\cdot}$세균학적 수질)

  • KIM Yong Gwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.4
    • /
    • pp.347-355
    • /
    • 1986
  • The Sonakdong river is very important water source not only for agricultural water of Kimhae field but also for fishery water. Recently the middle and lower areas of the river have the tendency to be heavily contaminated by domestic sewage and agricultural chemicals. Fifty six water samples were collected from 8 stations from July to December in 1985 for the experiment (Fig. 1). To evaluate the water quality, pH, water temperature, electrical conductivity, chloride ion, nutrients ($NO^{-}_{2}-N,\;NO^{-}_{3}-N,\;NH^{+}_{4}-N,\;PO^{3-}_{4}-P,\;SiO_2-Si$), total coliform, fecal coliform, and fecal streptococcus were determined. Range and mean value of the samples were as follows; pH $6.3{\sim}9.4$, 7.91; water temperature $6.1{\sim}34.8^{\circ}C,\;23.88^{\circ}C$; electrical conductivity (from St. A to G) $1.575{\times}10^2{\sim}30.50{\times}10^2{\mu}{\mho}/cm,\;6.57{\times}10^2{\mu}{\mho}/cm$; chloride ion $23.5{\sim}14,300mg/l$, 770.0mg/l; nitrite-nitrogen $0.007{\sim}0.110mg/l$, 0.053mg/l; nitrate-nitrogen $0.001{\sim}1.638mg/l$, 0.649 mg/l; ammonia-nitrogen $0.017{\sim}4.200mg/l$, 0.497mg/l; phosphate-phoshorus $0.011{\sim}0.281mg/l$, 0.086mg/l; and silicate-silicious $2.4{\sim}6.5mg/l$, 4.43mg/l. Electrical conductivity and chloride ion of the station F(Chomanpo) were $2.676{\times}10^2{\mu}{\Omega}cm$ and 123.99mg/l which were lower than those of others. Among the analyzed nutrients, silicate-silicious concentration was the highest through all the samples. The bacterial density of the samples ranged $36{\sim}110,000/100ml$ for total coliform, $15{\sim}46,000/100ml$ for fecal coliform and $3.6{\sim}15,000/100ml$ for fecal streptococcus. The range and the mean of the TC/FC ratio were $3.0{\sim}9.6$, 5.51 and those of the FC/FS ratio were $1.1{\sim}9.2$, 6.19, respectively. On the other hand, fecal coliform was not detected in about $78\%$ of the water samples examined. Composition of coliform was $52\%$ Escherichia coli group, $3\%$ Citrobacter freundii group, $13\%$ Enterobacter aerogenes group and $31\%$ others.

  • PDF

A STUDY ON THE MICROBIAL CONTAMINATION OF DENTAL UNIT AND ULTRASONIC SCALER (덴탈유니트의 핸드피스 및 초음파 치석 제거기의 미생물 오염에 관한 연구)

  • Lee, Byung-Moon;Kim, Chang-Whe;Kim, Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.64-80
    • /
    • 1998
  • The risk of cross-contamination in dental clinic is very high. Those who are engaged in dental clinic are exposed to various microorganisms in saliva and blood of patient. Potential possibility of cross-contamination of patient to patient, patient to dentist, dentist to laboratory technician always exist, which is important in the view of public health. It is well known that microorganisms may cause cross-contamination by suck-back of microorganisms into the water supply line or air supply line of dental unit and sprayed back into the next patient's oral cavity. The majority of microorganisms coming from dental unit are water microorganisms from the main water supply which have colonized the tube within the units and multiplied in the relatively warm and stagnant conditions. The purpose of this study is to measure the extent of microbial contamination of dental unit and ultrasonic scaler, to evaluate that dental unit water supply is suitable for drinking water, and to assess the effect of flushing on reduction of microbial contamination of dental unit and ultrasonic scaler. In the first experiment, water samples(50ml) from 20 dental units and 10 ultrasonic scalers in Seoul National Univ. Hosp. were tested for the presence of coliform. The samples were filtered by membrane filtration technique.(Microfil system, Millipore Co. U. S. A.) The filter was then placed onto MacConkey agar plate and the plates with filter on it were incubated aerobically at $37^{\circ}C$ for 5 days. The colors and shapes of colonies were examined if those were coliform. To verify the presence of coliform, the colonies were inoculated into phenol red lactose broth and incubated aerobically at $37^{\circ}C$ for 2 days. The fomation of gas was observed. In the second experiment, water samples from 20 handpieces, 10 ultrasonic scalers and 30 A/W syringes after 0, 2, 4, 6 min. flushing respectively were taken. $200{\mu}l$ water samples were spreaded on Brain Heart Infusion agar plate and the plates were incubated aerobically at $37^{\circ}C$ for 5 days. The number of colony was counted. The results obtained were summarized as follows 1. The water from dental unit and ultrasonic scaler was not suitable for drinking water. 2. No coliform was founded in dental unit and ultrasonic scaler water supply. 3. The number of colony of dental unit and ultrasonic scaler was highest in the group of o min. flushing(p<0.05). 4. There was no statistically significant difference in the extent of microbial contamination among handpiece, ultrasonic scaler and A/W syringe (p>0.05). 5. The number of colony was lowest in the group of 4 min. flushing, but there was no statistically significant difference among 2, 4, 6 min. flushing groups.(p>0.05) 6. It is recommended to flush dental unit water line for 4 min. after use on each patient.

  • PDF

Bacterial Flora of East China Sea and Yosu Coastal Sea Areas 1. Horizontal Distributions According to Number of Bacteria, Vibrio spp. and Coliform Group (여수연안 및 동중국해의 세균상 1. 일반 세균, Vibrio spp., 대장균군 균수에 따른 수평 분포)

  • JUNG Kyoo-Jin;SHIN Suk-U
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.1
    • /
    • pp.9-16
    • /
    • 1996
  • In order to understand microbial ecosystem in the fast china sea and Yosu coastal sea horizontal distributions of bacterial flora, Vibrio spp., coliform group, temperature, and salinity in this sea area, were studied 42 sampling stations during 6th-l4th August, 1992. From the results, salinity and temperature were $24.64\~33.78\%_{\circ}$ and $22.53\~29.18^{\circ}C$, respectively. As the open sea far from land goes on, salinity became low while temperature became high. Viable cell counts of bacteral flova, Vibrio spp., and roliform group in Yosu coastal sea water were $1.0\times10^2\~3.0\times10^4/ml,\;0.2\times10\~9.0\times10^3/ml,\;and\;0.3\times10\~3.0\times10^3/ml$ while those of these in the open sea water were $0.4\times10\~2.0\times10^3/ml,\;0.8\times10\~3.0\times10/ml,\;and\;0.9\times10\~1.3\times10/ml$, respectively.

  • PDF

Evaluation of the Microbiological Safety for the Seawater in a Part of the South Coast, Korea (남해안 일부해역 해수의 세균학적 위생안전성 평가)

  • Park, Yeong Min;Yoon, Hyun Jin;Ham, In Tae;Yoo, Hean Jae;Choi, Jong-Duck
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.4
    • /
    • pp.350-358
    • /
    • 2015
  • This study was designed to evaluate the sanitary characteristics of sea water in a part of the south coast, Korea and to check the seawater which is in compliance with the recommended bacteriological criteria for shellfish cultivation. The samples of sea water were collected at 14 sampling stations established in the survey area between March 2014 and October 2014. Food poisoning caused by seafood consumption is often associated with pathogenic microorganisms originated from fecal contamination. Therefore, fecal coliform is very important criteria for evaluating the safety of fisheries in coastal areas. The range of geometric mean (GM) and the estimated 90th percentile values of total coliform were 4.1~83.1 MPN/100 mL, and 11.7~834.1 MPN/100 mL, respectively. The GM and the estimated 90th percentile values of fecal coliform were 2.5~22.7 MPN/100 mL and 2.5~170.0 MPN/100 mL, respectively. Therefore, the bacteriological safety of seawater at this shellfish-growing area met with the Korean Shellfish Sanitation Program (KSSP) criteria for a growing area. However, the values are seasonally exceed the KSSP criteria, suggesting that the monitoring and evaluation of seawater quality is very important in shellfish-growing area.

Comparison of the effects of zinc oxide and zinc aspartic acid chelate on the performance of weaning pigs

  • Sarbani Biswas;De Xin Dang;In Ho Kim
    • Journal of Animal Science and Technology
    • /
    • v.66 no.1
    • /
    • pp.125-134
    • /
    • 2024
  • In this research, the growth efficiency, nutritional utilization, fecal microbial levels, and fecal score of weaned pigs were evaluated using therapeutic zinc oxide (ZnO) and zinc aspartic acid chelate (Zn-Asp). In a 42-day feeding trial, 60 weaned pigs ([Yorkshire × Landrace] × Duroc) were arbitrarily allotted (age: 21 days; 7.01 ± 0.65 kg preliminary body weight) to 3 different treatment groups with 5 repetitions (2 male and 2 female piglets) in each pen. The trial had 2 different phases, including 1-21 days as phase 1, and 22-42 days as phase 2. The nutritional treatments were: basal diet as control (CON), basal diet incorporated with 3,000 ppm ZnO as TRT1, and basal diet incorporated with 750 ppm Zn-Asp as TRT2. In comparison to the CON group, the pigs in the TRT1 and TRT2 groups had greater (p < 0.05) body weight on day 42; an average daily gain, and an average daily feed intake on days 22-42. Furthermore, during days 1-42, the average daily gain in the treatment groups trended higher (p < 0.05) than in the CON group. Additionally, the fecal score decreased (p < 0.05) at week 6, the lactic acid bacteria count tended to increase (p < 0.05), and coliform bacteria presented a trend in reduction (p < 0.05) in the TRT1 and TRT2 groups compared to the CON group. However, there was no difference in nutrient utilization (p > 0.05) among the dietary treatments. Briefly, the therapeutic ZnO and Zn-Asp nutritional approaches could decrease fecal score and coliform bacteria, increase lactic acid bacteria, and improve growth efficiency; moreover, Zn-Asp (750 ppm) can perform a comparable role to therapeutic ZnO (3,000 ppm). So we can use Zn-Asp (750 ppm) instead of therapeutic ZnO (3,000 ppm) for the better performance of weaning pigs and the reduction of environmental pollution, as therapeutic ZnO is responsible for environmental pollution.

A Study on Microbial Contamination of Foods Exposed to Multiple Environments

  • KIM, Dan-Bee;CHA, Seong-Soo
    • The Korean Journal of Food & Health Convergence
    • /
    • v.5 no.3
    • /
    • pp.35-40
    • /
    • 2019
  • In this study, general bacterial counts and coliform counts, which are hygienic indicator microorganisms, were tested for candy, chocolate, and jelly which are easily available and enjoyed around. After dropping each sample on the desk, indoors, and outdoors, it is immediately collected, or washed and collected to confirm the myth of the 3-second rule. Immediately after removing the wrapping paper, each sample was dropped on the desk, indoors, and outdoors, and after 3 seconds from the moment of contact with the surface, and then collected in a sample bag using sterilized sanitary gloves. After the same operation, each sample was rinsed for 5 seconds using sterilized sanitary gloves and sterilized distilled water, and then collected in a sample bag. The number of bacteria detected in non-washing candies was 41 CFU/g at outdoor and the number of bacteria detected in non-washing chocolate was 76 CFU/g at outdoor. The number of bacteria detected in non-washing jellies was 79 CFU/g at outdoor. Coliform group was not detected in all samples. This showed good results at the level of m = 10,000 or less, which is an allowable value suggested in the Food Code. Also, effect of washing on contaminated food was confirmed. This result is remarkably low compared with the microorganism specimens shown in Food Code, and it is confirmed that contamination occurs but not high value. Therefore, the myth of the 3-second rule is true compared to the figures based on Food Code. However, it showed the characteristics of bacteria that could survive and cross-contaminate on dry food surfaces and emphasized the importance of hygiene through food contact to unsanitary surfaces to minimize the risk of food poisoning.