• Title/Summary/Keyword: cold temperature

Search Result 3,360, Processing Time 0.033 seconds

Properties of Strength Development Under Various Curing Condition at Early Age of Cement Mortar Using Agent for Enduring Cold Weather (내한성 혼화제를 이용한 시멘트 모르타르의 초기양생 온도변화에 따른 강도증진 특성)

  • Han, Cheon-Goo;Hong, Sang-Hee;Kim, Hyun-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.5 no.2
    • /
    • pp.191-197
    • /
    • 2001
  • In this study, the admixtures for agents for enduring cold weather used widely are collected and applied to cement mortar to analyze the strength development due to variation of curing temperature at early age. The test results show that anti-freezing admixture have some problems due to high chloride content, which may cause the corrosion of reinforcement embedded in concrete. However, the mortar applied by accelerator and another kind of agent for enduring cold weather produced by S company lead to delay of strength development in low temperature. Also, it is clarified that there are no significant problems for cement mortar in strength development due to low temperature if a suitable kind of agent enduring cold weather is used and cement mortar is cured for more than $7.5^{\circ}D.D$ at early age.

  • PDF

Thermoregulation and Clothing Selection Behavior of the Sensitive Person to the Cold (추위에 민감한 사람의 체온조절반응과 의복선택행동)

  • 정운선
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.2
    • /
    • pp.199-204
    • /
    • 2000
  • This study was conducted to investigate the thermoregulatory responses and wearing behavior of the cold-sensitive men when exposed to the mild cold of 14$^{\circ}C$. Two sessions of experiment were carried out and five healthy young men for the cold-sensitive group(CSG) and four healthy young for the cold-insensitive group(CIG) participated in the study as subjects CSG maintained rectal temperature lower than CIG due to their thicker clothing resulted in larger decrease of rectal temperature. CSG maintained skin temperatures higher than CIG. CSG felt cooler than CIG but wore thicker clothing for thermal comfort and this made keep their sensation warmer. These results were discussed in terms of autonomic and behavioral temperature regulation.

  • PDF

Effects of Soup Temperature on Hunger, Energy and Nutrient Intake (국의 온도가 공복감, 열량 및 영양소 섭취량에 미치는 영향)

  • 김석영;장희애;김주영;박경민
    • Journal of Nutrition and Health
    • /
    • v.36 no.8
    • /
    • pp.859-869
    • /
    • 2003
  • The purpose of this study was to compare the effects of soup temperature on hunger, energy, and nutrient intake. The hot meal consisted of 400 g of hot beef-vegetable soup (75$^{\circ}C$), Yubu Chobap, Bulgogi, cucumber pickle and radish pickle. The cold meal component were the same as the hot meal except 300 g of water (8$^{\circ}C$) and boiled vegctables (100 g), instead of the hot beef-vegetable soup ot the hot meal. Thirst, core temperature and blood pressure were also measured before and after consumption the test meals in a within-subjects, repeated measures design. 30 women consumed 17% more kilocalories, 13% more protein and lipid and 16% more carbohydrate in the cold meal than in the hot meal. The core temperature at the end of the test meal was higher in the hot meal than in the cold meal. Energy and nutrient intake were inversely correlated with the hunger scores within 1 hour after the hot meal, however those are not related with each other in the cold meal. So hunger feeling might be disturbed in the cold meal. It is concluded that energy and nutrient consumptions were higher in the cold meal, partly because of the distrubed hunger feeling in the cold meal.

Measurement of Irrigation Water Temperature and Preventive Measure against Cold Watter Damage to Paddy Rice (벼의 냉수피해 감소를 위한 관개수온 조사와 대책수립)

  • 정상옥
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.1
    • /
    • pp.52-59
    • /
    • 1999
  • Paddy rice is semi-tropical crop and requires warmirrigation water. If mean water temperature at the water source during the growing period is below 18$^{\circ}C$, sime kinds of water warming mechanism should be taken. In this study irrigation water temperature is measured and preventive measures to cold water damage on paddy rice are suggested. Field observations were performed at 100ha field area downtream of the Unmoon reservoir during the growing season of 1997. Land use, canal system, water temperature at irrigation canals. reservoir, and paddy fields were observed. In addition, growth and yield of the rice at selected plots were observed. Accordingly to the record, cold water damage occurred in this area due to the cold irrigation water supply in 1996. It did not occur because of the effective irrigation water management practice in 1997. However, several preventive measures such as pontoon intake system, using existing weir and construting a new warming pond, are suggested to prevent cold water damage in the future. If a new warming pond is construted to raise irrigation water temperature by 2 $^{\circ}C$, a pond area of 2.94 ha is required.

  • PDF

[Retracted]The effect of Massage and Paraffin on Cold Hypersensitivity Patient ([논문표절]수족냉증에 적용한 마사지와 파라핀의 효과)

  • Roh, Hyo-lyun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2017.05a
    • /
    • pp.101-102
    • /
    • 2017
  • This study of purpose was to evaluate the changes in hands and feet temperature by applying massage and paraffin bath.. The subject of this study was 30 university healthy students. Subjects were divided into paraffin bath group and massages group. The digital infrared thermographic imaging was used for thermographic analysis. The visual analog scale was used for subjective information about the degree of cold sensitivity and cold stress test was used for analyzing the temperature recovery rate. After the interventions showed that temperature difference of the right hand and temperature difference of the left hand are less in the paraffin group than the massage group. When applied paraffin bath and massage to the cold hypersensitivity patient the massage group showed difference in the visual analog scale and the paraffin group showed difference in the temperature of the right hand, left hand, left foot and in the visual analog scale. Paraffin bath treatment seems to be useful to patients with cold hypersensitivity on hands and feet.

Temperature Separation Characteristics of a Vortex Tube Based on the Back Pressure of the Cold Air Exit (저온 출구의 배압조건에 따른 볼텍스 튜브의 온도분리 특성 연구)

  • Im, Seokyeon
    • Tribology and Lubricants
    • /
    • v.32 no.5
    • /
    • pp.166-171
    • /
    • 2016
  • Electric vehicle ownership is expanding for two reasons: its technology features have enhanced fuel economy, and the number of vehicle emissions regulations is increasing. Battery performance has a large influence on the capability of electric vehicles, and even though battery thermal management has been actively researched, specific technological improvements to battery performance are not being presented. For instance, many industrial applications utilize vortex tubes as components for refrigeration machines because of their numerous intrinsic benefits. If electric vehicles incorporate vortex tubes for battery cooling, performance and efficiency advancements are possible. This study uses a counter-flow vortex tube to investigate its temperature separation characteristics, based on the back pressure of the cold air exit and the difference between the inlet and back pressures. The experiment uses a vortex tube with the following parameters: six nozzle holes, a 20 mm inner vortex diameter (D), a 14D tube length, a 0.7D cold exit orifice diameter, and a nozzle area ratio of 0.142. The measurements prove that the temperature difference between the hot air and cold air decreased because of the flow resistance of the hot air and the backflow phenomenon at the cold air exit. The flow resistance causes the temperature difference to decrease, and the back pressure of the cold air exit influences the flow resistance. The results show that the back pressure significantly influences the efficiency of temperature separation.

Low Temperature δ-Precipitation of Inconel 718 Alloy Wire during Cold Drawing (인코넬 718합금 선재의 냉간 인발시 δ 상 저온 석출 현상 연구)

  • Park, Jae Man;Kim, Yong Hwan;Jang, Heui Un;Chung, Won Sub
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.7
    • /
    • pp.511-516
    • /
    • 2012
  • Low temperature ${\delta}$-precipitation phenomenon below 2-step aging ($718^{\circ}C$, $8hr+621^{\circ}C$, 8 hr) temperature of cold drawn Inconel 718 alloy wire was investigated. The investigation was carried out on wires with a cold drawn ratio of 0, 20, 50 and 70% using OM, SEM, XRD, TEM, and DSC. In microstructures of 50 and 70% drawn wire, many precipitates were found along the grain boundaries and the twin boundaries in deformation band. From the results of the XRD and TEM analysis, the precipitates were identified as plate-like ${\delta}$-phase. From the results of the DSC analysis, it was also found that a temperature of ${\delta}$-precipitation decreases with an increase of the cold drawn ratio. We concluded that cold drawing of inconel 718 wire promotes the ${\delta}$-precipitation, and under the condition of a high drawing ratio, the ${\delta}$-phase could be precipitated at a temperature below the aging temperature ($718^{\circ}C$).

The Effects of Regular Jjimjilbang Exposure on Cold Tolerance in Young and Elderly Females (정기적인 찜질방노출이 청년과 노년 여성의 내한성에 미치는 영향)

  • Choi, Jeong-Wha;Song, Eun-Young;Hwang, Soo-Kyung
    • The Korean Journal of Community Living Science
    • /
    • v.18 no.4
    • /
    • pp.599-607
    • /
    • 2007
  • We analyzed the effects of regular Jjimjilbang (Korean sauna) exposure on the cold tolerance in young and elderly females. Subjects were young (n=7) and elderly (n=7) females who had never had Jjimjilbang exposure experience. The Jjimjil training group was exposured in the Jjimjilbang 19 times per week. Jjimjibang exposure was limited to three times per day. Jjimjil activity was taken freely. To prove the effects of the cold tolerance, subjects were exposed to cold air ($12{\pm}1^{\circ}C,\;60{\pm}10%$RH). In these conditions, subjects were exposed for 30 minutes at which time rectal temperature, skin temperatures, clothing microclimate, energy expenditure, blood pressure and subjective sensation were measured. To prove the effects of the local cold tolerance, vascular hunting reaction was observed measuring the finger skin temperature while the left middle finger tip was immersed in cold water of $0^{\circ}C$ for 30 minutes. The results are as follows. According to repeated Jjimjil exposure, rectal temperature changes, peripheral temperature and energy expenditure were increased gradually in the cold climate chamber. Blood pressure, subjective sensation and vascular hunting reactions did not show any significant difference. In conclusion, regular Jjimjilbang exposure has negative effects on the ability of the body to improve its regulation of temperature especially in cold tolerance.

  • PDF

Design of closed-loop nitrogen Joule-Thomson refrigeration cycle for 67 K with sub-atmospheric device

  • Lee, C.;Lee, J.;Jeong, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.1
    • /
    • pp.45-50
    • /
    • 2013
  • Closed-loop J-T (Joule-Thomson) refrigeration cycle is advantageous compared to common open loop $N_2$ decompression system in terms of nitrogen consumption. In this study, two closed-loop pure $N_2$ J-T refrigeration systems with sub-atmospheric device for cooling High Temperature Superconductor (HTS) power cable are investigated. J-T cooling systems include 2-stage compressor, 2-stage precooling cycle, J-T valve and a cold compressor or an auxiliary vacuum pump at the room temperature. The cold compressor and the vacuum pump are installed after the J-T valve to create sub-atmospheric condition. The temperature of 67 K is possible by lowering the pressure up to 24 kPa at the cold part. The optimized hydrocarbon mixed refrigerant (MR) J-T system is applied for precooling stage. The cold head of precooling MR J-T have the temperature from 120 K to 150 K. The various characteristics of cold compressor are invstigated and applied to design parameter of the cold compressor. The Carnot efficiency of cold compressor system is calculated as 16.7% and that of vacuum pump system as 16.4%. The efficiency difference between the cold compressor system and the vacuum pump system is due to difference of enthalpy change at cryogenic temperature, enthalpy change at room temperature and different work load at the pre-cooling cycle. The efficiency of neon-nitrogen MR J-T system is also presented for comparison with the sub-atmospheric devices. These systems have several pros and cons in comparison to typical MR J-T systems such as vacuum line maintainability, system's COP and etc. In this paper, the detailed design of the subcooled $N_2$ J-T systems are examined and some practical issues of the sub-atmospheric devices are discussed.

Diagnostic Tool for Cold Sensation of Hands: A Preliminary Study (수부냉증 진단방법에 관한 기초연구)

  • Ko, Seung-woo;Park, Jong-ju;Kong, Kyung-hwan;Go, Ho-yeon
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • Objectives: The aim of this study was to find an effective medical device to detect cold sensation of hands. Methods: Patients with cold sensation of hands (N=42) were recruited in July 2013. We surveyed patients’ general characteristics, severity of cold sensation, body temperature in Nogung (PC8) and Hyeopbaek (LU4) measured with a digital thermometer, digital infrared thermal imaging, and pulse wave velocity. Results: The relation between severity of cold sensation and temperature in Nogung (PC8) and Hyeopbaek (LU4) was statistically significant. The results showed a higher correlation of severity of cold sensation with Nogung (PC9) than with Hyeopback (LU4) temperature. No other indices were statistical significant. Conclusions: Measuring the Nogung (PC9) temperature is most reasonable for assessing the severity of cold sensation of hands. To generalize this result, however, a large-scale study is warranted.