• Title/Summary/Keyword: cold environment

Search Result 925, Processing Time 0.031 seconds

A Study on the Cold Flow Characteristics of a Flue Gas Recirculation Burner with Both Outlets Opening (양쪽 출구가 트인 배기가스 재순환 버너의 냉간 유동 특성에 관한 연구)

  • Ha, Ji Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.7-12
    • /
    • 2018
  • Thermal NOx is generated in a high temperature environment in a combustion facilities. Exhaust gas recirculation method is widely used among various methods for reducing nitrogen oxides in combustion devices. In the present study, the computational fluid dynamic analysis was accomplished to elucidate the cold flow characteristics in the flue gas recirculation burner with both outlets opening. Because the reciculation pipes is installed toward the tangential direction, the swirling flow is formulated in the burner and the phenomenon of the reverse flow creation is detected at the center area of circular burner. We are confirmed that this is the similar trend with the burner with one side outlet closed. From the present study, it was seen that the recirculated inflow from both recirculated burner outlets increased by about 5% compared to the burner with one side outlet opening. At the outlet located at the exhaust gas recirculation pipe inlet(gas exit 1), the inlet flow was formed in the entire region. At the opposite outlet(gas exit 2), the total flow was discharged, but the center part of the burner was observed to have a reverse flow. The flow rate at the gas exit 2 was 3 ~ 5 times larger than the flow rate at the gas exit 1.

Study on the Complaint ratio of Respiratory Symptoms of Dental Laboratory Technician in Small Cities in Jullabuk-do (전라북도(全羅北道) 중소도시(中小都市) 치과기공사(齒科技工士)의 호흡기장애(呼吸器障碍) 호소율(呼訴率)에 대한 조사(調査))

  • Lee, In-Kye
    • Journal of Technologic Dentistry
    • /
    • v.17 no.1
    • /
    • pp.26-40
    • /
    • 1995
  • A survey has been performed for the dental technicians and office workers in small cities of Julla buk-do on theis problem of cough, phlegm, wheezing, nasal cattarrh & cold, and breathlessness by using SUN-81-AL survey form which is a guletionaire on respiratory symptons The results of the analysis are as follaus. 1. The complaint on cough was made by 15 dental technicians(21.4% and by 10 office workerr(16.7%). Dental technicians showed higher complaint on cough than office workers. The predietor variable for cough was the working hours for dental technicians and the period of smoking for the office sorkess. 2. The complaints on phelgm was made by 34 dental technicians(48.6%) and by 9 office workers(15.0%). The predictor variable on phelgm was the working hour for dental techniume and the period of smoking for the office workers. There was no statistically significant difference between two group on their complaint level. 3. The complaint on the breathlessnesr was made by 24 dental technicians(34.3%) and by 22 office workers(36.7%). The predictor variable on breathlessness was the period of smoking for dental technicians and the working hour for office workers. 4. The wmplaing on nasal catarrh & cold wax made by 29 dental technicians(41.4%) and 22 office workers(36.7%). The predictr variable on nasal catarrh & cold was the working hour for dental workerr, and the perird of smoking for the office workers. 5. The complaint on wheezing was made by 9 dental technicians(12.9%) and 8 office workers(13.3%). The primary predictor variable on wheezing was the working hour for both groups, and the secondary predictor variable was the period of smoking. 6. The complaint on the chest and lung dislase was made by 12 dental technicians(17.1%) and 4 office workers(6.7%) dental technicians showed bigher complaint. on chest and lung disease than the office workers. Bronchitis was the higher frequency illuess reported from both of the groups among chest and lung disease. 7. In conclusion, the predictor variable on respiratory illness was the working hour for dental techniciane, and the period of smoking for the office workers 8. 25 dental technicians(35.7%) and 9 office workers(15.0%) selected air pllution as the most urgent problem that working environment, has had. There was statistically significant difference between two groups(P<0.001)

  • PDF

A Study of Cold Flow Characteristics of a Flue Gas Recirculation Burner using Coanda Nozzles (코안다 노즐을 이용한 배기가스 재순환 버너의 냉간 유동 특성에 관한 연구)

  • Ha, Ji Soo;Park, Chan Hyuk;Shim, Sung Hun;Jung, Sang Hyun
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.152-158
    • /
    • 2016
  • Nitrogen oxide is generated by the chemical reaction of oxygen and nitrogen in higher temperature environment of combustion facilities. The NOx reduction equipment is generally used in the power plant or incineration plant and it causes enormous cost for the construction and maintenance. The flue gas recirculation method is commonly adopted for the reduction of NOx formation in the combustion facilities. In the present study, the computational fluid dynamic analysis was accomplished to elucidated the cold flow characteristics in the flue gas recirculation burner with coanda nozzles in the flue gas recirculation pipe. The inlet and outlet of flue gas recirculation pipes are directed toward the tangential direction of circular burner not toward the center of burner. The swirling flow is formed in the burner and it causes the reverse flow in the burner. The ratio of flue gas recirculation flow rate with the air flow rate was about 2.5 for the case with the coanda nozzle gap, 0.5mm and it was 1.5 for the case with the gap, 1.0mm. With the same coanda nozzle gap, the flue gas recirculation flow rate ratio had a little increase when the air flow rate changes from 1.1 to 2.2 times of ideal air flow rate.

Relationship between Total Body Fat and S/V Ratio and Body Cooling for Two Hours at $15^{\circ}C$ (한냉에 노출된 인체의 냉각과 총지방량 및 S/V 비율 사이의 관계)

  • Chung, Kwan-Ogg;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.3 no.1
    • /
    • pp.19-28
    • /
    • 1969
  • Skin temperatures on 10 sites and rectal temperature at every 10 minutes, oxygen consumption at every 20 minutes were measured on 18 male subjects (ages between 14 and 47 years) after exposure to cold air at $15^{\circ}C$ for two hours in a climatic room. Total body fat measured by means of a skinfold method and ratio of body surface area (S) to body volume (V), S/V, were utilized as basis of observations. Surface area was calculated after DuBois equation and body volume was calculated by our original formula. In influencing on the heat loss from the body core to the cold environment, % fat showed inverse relations, whereas, S/V ratio showed direct relations. Thus these two factors acted antagonistically on the body heat loss. Local skin temperatures showed negative correlations with skinfold thickness on the same site, nemaly, on chest, r=-.567; on back, r=-.507; and on upper arm, r=-.353. The other 7 skin sites showed low correlations with % fat. Minimum mean weighted skin temperature (MWST) showed a negative correlation (r=-.443) with % fat, and showed no correlation with S/V ratio. Oxygen consumption in the cold air at $15^{\circ}C$ increased from the first measurement at 20 minutes after exposure and maintained the same increasing trend up to 120 minutes. ${\Delta}T_R$ was greater in tile lean subjects who showed a greater % change in oxygen consumption. The antagonistic actions of % fat and S/V ratio on the heat loss were manifested by observations as follows: minimum rectal temperature was higher In fat subjects (r=.600) and lower in subjects with a greater S/V ratio (=-.582), ${\Delta}T_R$ was smaller in fat subjects (r=-.738) and greater in subjects with a greater S/V ratio (r=.618). Temperature difference between body core and skin surface (minimum rectal temperature minus minimum MWST) showed a positive correlation with % fat (r=.600) and a negative correlation with S/V ratio (r=-.881). Decrease in the mean body temperature and heat debt, respectively, showed negative correlations with % fat and positive correlations with S/V ratio.

  • PDF

Distribution of Cyanotoxin Microcystin-LR in Han River System and Ecological Park in Seoul and Kyunggi Districts (서울 경기지역의 공원 연못 및 한강 수계내 조류독소 Microcystin-LR의 분포)

  • Suh, Mi-Yeon;Kim, Baik-Ho;Han, Myung-Soo
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.2 s.112
    • /
    • pp.237-248
    • /
    • 2005
  • To determine the content of hazard microcystin (MC) in Han River system and Ecological Ponds in Seoul City and Kyunggi district, a most toxic derivative, microcystin-LR (MCLR) of 15 samples of 7 ponds, 4 rivers and 4 reservoirs during low precipitation and cold season in 2003 were analyzed by ELISA method. With the change of water temperature ($0.4\;{\sim}\;21.9^{\circ}C$), cyanobacteria including Microcystis aeruginosa dominated the cold phytoplankton community in small ecological ponds such as Kyungbokgung Kyunghyaeru (KBP), Seokchon reservoir (SCR), Yangsoori Ryukgakji (YSS), having the long residence time. Contents of MCLR (the detection limit; $0.05\;{\mu}g\;L^{-1}$) were high in cyanobacteria-rich sites, especially, Microcystis aeruginosa. Total MCLR, cell extracted type plus dissolved type, were $1.39\;{\mu}g\;L^{-1}$ in KBP, $0.55\;{\mu}g\;L^{-1}$ in SCR and $0.59\;{\mu}g\;L^{-1}$ in YSS, in the first sampling having a high temperature (>$20^{\circ}C$), while some detected only in YSS during the cold season. As expected, the MCLR content was correlated with Microcystis aeruginosa (r = 0.526 for cell extracted type, r = 0.433 for dissolved type). Therefore, low concentration of MCLR detected in small ponds and Han river system in Seoul metropolitan city and Kyunggi district, maybe hardly affect human recreation activity, especially the drinking water supply.

A Investigation and Analysis of Water Temperature by Juam Regulation Dam Outflow in Downstream and Suncheon Bay (주암조절지댐 방류수에 따른 하천 및 순천만 일대 수온변화 조사분석)

  • Lee, Hyeon No;Jung, Kwan Sue;Cheon, Geun Ho;Hur, Young Teck
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.6
    • /
    • pp.501-509
    • /
    • 2015
  • Lately multipurpose dam is required to consider various interests such as quality, ecological environment as well as flood control, water supply, hydropower generation, etc. The objective of this study is to investigation and analysis of water temperature in the areas where there are social conflicts due to cold water outflow. In this study, we monitored water temperature of Juam regulation dam, downstream river, Suncheon bay in a long term period and performed comparative analysis on a change of water temperature in downstream river and Suncheon bay by using three-dimensional numerical mode (EFDC) considering various external factors such as water outflow amount. The result of monitoring and numerical modelling indicates that effects of cold water outflow takes place from april to september. Also effects of the low temperature discharge of dam was complicatedly altered by various factors such as outflow time and amount, weather and tide level conditions etc. The result of this study can be utilized as a basic data for establishing improvement of dam operation plan to minimize negative effects of dam's cold temperature water outflow to downstream river and coastal area.

Population attributable fraction of indicators for musculoskeletal diseases: a cross-sectional study of fishers in Korea

  • Jaehoo Lee;Bohyun Sim;Bonggyun Ju;Chul Gab Lee;Ki-Soo Park;Mi-Ji Kim;Jeong Ho Kim;Kunhyung Kim;Hansoo Song
    • Annals of Occupational and Environmental Medicine
    • /
    • v.34
    • /
    • pp.23.1-23.14
    • /
    • 2022
  • Background: The musculoskeletal disease (MSD) burden is an important health problem among Korean fishers. We aimed to investigate the indicators of the prevalence of MSD and contributions of significant indicators to MSD in Korean fishers. Methods: This cross-section study included 927 fishers (male, 371; female, 556) aged 40 to 79 years who were enrolled from 3 fishery safety and health centers. The outcome variable was one-year prevalence of MSD in 5 body parts (the neck, shoulder, hand, back, and knee). Independent variables were sex, age, educational attainment, household income, job classification, employment xlink:type, hazardous working environment (cold, heat, and noise), ergonomic risk by the 5 body parts, anxiety disorder, depression, hypertension, diabetes, and hyperlipidemia. The adjusted odds ratio of MSDs by the 5 body parts were calculated using multiple logistic regression analysis. We computed the population attributable fraction (PAF) for each indicators of MSDs using binary regression models. Results: The one-year prevalence of MSD in the neck, shoulder, hand, back, and knee was 7.8%, 17.8%, 7.8%, 27.2%, and 16.2% in males vs. 16.4%, 28.1%, 23.0%, 38.7%, and 30.0% in females, respectively. The ergonomic risk PAF according to the body parts ranged from 22.8%-59.6% in males and 22.8%-50.3% in female. Mental diseases showed a significant PAF for all body parts only among female (PAF 9.1%-21.4%). Cold exposure showed a significant PAF for the neck, shoulder, and hand MSD only among female (25.6%-26.8%). Age was not a significant indicator except for the knee MSD among female. Conclusions: Ergonomic risk contributed majorly as indicators of MSDs in both sexes of fishers. Mental disease and cold exposure were indicators of MSDs only among female fishers. This information may be important for determining priority risk groups for the prevention of work-related MSD among Korean fishers.

A Study on the Thermal Sensation Vote of the Log House in Winter Season (통나무집의 동절기 실내 온열감 평가에 관한 연구)

  • Min, Byeong-Cheol;Jeon, Ji-Hyeon;Shin, Yong-Gyu;Kang, Sang-Woo;Kook, Chan
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.297-300
    • /
    • 2006
  • Various buildings constructed by environmentally friendly resources are being built in KOREA. Especially the building made by the wood, which has environmental characteristics that the reinforced concrete and brick doesn't have, are acknowledged with its superiority. Then, studies on indoor thermal control capability of the wooden building and influence of its indoor environment to sensory environment of occupants are not enough proceed. Thus, there were proceeded 24 hours measurements for indoor and outdoor thermal environmental elements of Log Cabins and the hourly subjective tests to evaluate indoor amenity of occupants in this study. The results of the study are following: 1) Upon evaluation on thermal environment elements, indoor and outdoor dry bulb temp were 22.0$^{\circ}C$ and -2.9$^{\circ}C$, and Indoor and outdoor average relative humidity were 25.8%and 52.7%. Differences of indoor and outdoor temperature and humidity were 24.9$^{\circ}C$ and 26.9%. 2) Upon contrastive analysis between the results of subjective tests, warm and cold sensation vote, and PMV (Predicted Mean Vote) and PPD (Predicted Percent Dissatisfaction), values of subjective tests W.9

  • PDF

A Comparative Study on the Windchill Indices (체감온도이론의 비교 연구)

  • Park, Jeon-Hwan;Han, Uk;Park, Rae-Seol
    • Journal of the Korean earth science society
    • /
    • v.23 no.8
    • /
    • pp.676-682
    • /
    • 2002
  • The concept of sensible temperature in winter is an attempt to quantify the sensation of cold by dry-bulb temperature combined with wind speed. Siple-Passel’s windchill equivalent temperature originated in experiments that are not conformable to various human conditions. Therefore, many investigators have found the flaws which are listed. Steadman’s model is based on the concept of thermal equilibrium and more sound and more representative of human conditions. But no classifications exist for Steadman’s windchill equivalent temperature, yet. The JAG/TI-model which was developed by US and Canada is more accurate, easy to understand and reflects human beings by conducting experiments using human volunteers but didn't take into account solar radiation, wet condition and physical state of the individual. Because of individual differences in people’s age, activity, health, metabolic rate, etc., no experimental evidence exists to suggest whether Siple-Passel’s, Steadman’s and JAG/TI-model’s windchill equivalent temperature is more applicable to the majority of people. Therefore we need the windchill model which is best applicable to Korean Army.

The Characteristics of the Learning Performance according to the Indoor Temperature of the Learning Environment and the Color of the Learning Materials (학습 환경의 실내 온도와 학습재료의 색채에 따른 학습수행의 특성)

  • Kim, Boseong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.681-687
    • /
    • 2013
  • This study examined whether the combination of the indoor temperature on the learning environment and the colors of the learning materials affect the learning performance. To do this, the condition of indoor temperature was divided into three conditions: the neutral condition which is the appropriate temperature condition of the learning activities ($22.5{\sim}24^{\circ}C$), the high-temperature condition (> $24^{\circ}C$), and the low-temperature condition (< $22.5^{\circ}C$). In addition, colors of red, blue, black, and green were used as the warm, cold, and neutral colors, and the verbal-working memory task was used as the learning task. As a result, it was not significant differences in the response time of the learning task, whereas, in the accuracy rate of the learning task, the performance was more accurate in red- and black-color conditions. These results could be interpreted as the saliency and color-temperature of the red color, and the familiarity and specificity of the black color.