• Title/Summary/Keyword: cold environment

Search Result 925, Processing Time 0.028 seconds

The Effect of Carbon on the Hot Corrosion of lron by Sulfur Containing Environment. (철의 고온 황화부식에 미치는 탄소의 영향)

  • 최성필;강성군;백영남
    • Journal of Surface Science and Engineering
    • /
    • v.21 no.2
    • /
    • pp.53-67
    • /
    • 1988
  • The high temperature corrosion of Fe-C alloys were studied at I atm SO gas in the temperature range 500~80$0^{\circ}C$ by means of a thermogravimetric analysis. The Na2SO4 induced high tempwrature corrosion rate was also measured at atm O2 gas under above the temperature renge. The reaction products were identified with the aid of X-ray diffraction technique, and micostruction of the alloy/scale interface was observed with a optical microscope and SEM. The experimental results were disussed by the themodeynamic calcutions. Under above the experimental condition. the reaction rates decrbon with increasing carbon content. The transfer of Fe ion was limited by a residue of carbon precipitated at alloy scale interface due to the oxidation of Fe-C alloys at alloy surface. The effect of cold working on reaction rate was different between the Fe containing low carbon and Fe-C Alloy containing carbon above 0,73 wt%. In a cold worked iron containing low carbon content, the crystallization of metal surface leads to the poor adherence between the alloy and the cavity formed between the alloy and scale. The outward diffusion of ion through the scale is estimated to be hindered by the cavity formed between the scale, consequently decreasing reaction rate. In the case Fe-C containing carbon above 0.73 Wt% alloy, the reaction rate was little affected by cold working, because the effect of content on reaction rats is greater than the effect of cold working.

  • PDF

Field Application of Insulation Curing Method for the Concrete applying Double Layer Bubble Sheets Subjected to Cold Weather (이중버블시트를 이용한 단열보온 양생공법의 한중콘크리트 현장적용)

  • Hong, Seak-Min;Son, Ho-Jung;Oh, Chi-Hyun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.83-85
    • /
    • 2011
  • This study investigated the results of insulation heat curing method using double layer bubble sheet in concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that concrete was protected from early freezing by remaining between 7℃ and 3℃ even in case outside temperature drops -7℃ below zero until the 3d day from piling. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF

Field Application of Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather (이중버블시트를 이용한 단열양생공법의 한중콘크리트 현장적용)

  • Hong, Seak-Min;Lee, Il-Sun;Baek, Dae-Hyun;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.25-28
    • /
    • 2009
  • This study investigated the results of insulation heat curing method using double layer bubble sheet in slab concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that slab concrete was protected from early freezing by remaining between 5 and $l0^{\circ}C$ even in case outside temperature drops $-11^{\circ}C$ below zero until the 4nd day from piling. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF

Strength and Reduction Behaviour of Cold-bonded Pellet for Blast Furnace Burden using Iron-bearing Dust (함철 더스트를 원료로 한 고로용 비소성 펠릿의 강도 및 환원거동)

  • 김태동;백찬영;조종민
    • Resources Recycling
    • /
    • v.4 no.1
    • /
    • pp.60-68
    • /
    • 1995
  • Iron-bearing dust which stems from steelworks were pelletized and bonded with portland cement in order to attempt to use for blast iurnace burdens. The characterist~cs of cold bonded dust pellet were investigated. It was found that the compression strength of cold bonded pellet contaning portland cement of 10 wt.% reached above 150kg/p by proper curing treatment. Direcl contad of carbon with iron oxides seems to greately enhance a reduction reaction and herewxth increased chances to lorn pores at high temperature environment. Tumbler strength, RDI, and swelling of cold bonded pellet were similiar to and/or better than those of iron ore sinter and fired pellet.

  • PDF

NOx Conversion Efficiency of SCR Diesel Vehicle Under Cold Start Condition (냉간 시동 조건에서의 SCR 경유자동차의 NOx 전환 효율)

  • Lee, Dong In;Yu, Young Soo;Park, Junhong;Chon, Mun Soo;Cha, Junepyo
    • Journal of ILASS-Korea
    • /
    • v.23 no.4
    • /
    • pp.244-253
    • /
    • 2018
  • Recently, The ministry of Environment in korea have introduced Euro-6d temp which was strengthened at the same time as Europe. Small Light-duty passenger vehicles need the SCR system of after-treatment to meet enhanced emission regulations. However, SCR system has a low conversion efficiency in a low temperature less than 200 degree. In this study, the NOx conversion efficiency of SCR system was analyzed by installing a NOx sensors and a temperature sensors in a diesel vehicle. Also, in order to analyze the effect of the cold-start, the test was performed on the same RDE route and compared with the test of hot-start. As a result, SCR system has characteristics of low conversion efficiency under cold-start conditions.

The Study on the Strength Properties of High Volume Fly-Ash Concrete (플라이애시를 다량 사용한 콘크리트의 강도특성에 관한 연구)

  • Paik, Min-Su;Lee, Young-Do;Jung, Sang-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.4
    • /
    • pp.169-176
    • /
    • 2002
  • To study of binder and fine aggregate a lot of replacement fly-ash concrete, initial characteristics, standard environment of curing temperature $20^{\circ}C$, hot-weather environment, cold weather environment of curing temperature $5^{\circ}C$. Flash concrete tested slump, air contest, setting and Hardening concrete valuated setting period of form, day of age 3, 7, 28 compression strength in sealing curing. Underwater curing specimen compression strength of age 3. 7, 28day used strength change accordingly fly-ash concrete curing temperature. Purpose of study is consultation materials in field that variety of fly-ash replacement concrete mix proportion comparison and valuation. (1) Setting test result, fly-ash ratio of replacement higher delay totting time. Same volume of fly-ash ratio of replacement is lower fly-ash ratio of replacement fine aggregate delay setting time. Setting test in curing temperature $35^{\circ}C$ over twice fast setting in curing temperature $20^{\circ}C$ and all specimen setting delay in curing temperature $5^{\circ}C$. F40 specimen end of setting about 30 time. (2) Experiment result age 28day compression strength more fisher plan concrete then standard environment in curing temperature $20^{\circ}C$, cold weather environment in curing temperature $5^{\circ}C$, most strength F43 is hot-weather environment in curing temperature $35^{\circ}C$ replacement binder 25%, fine aggregate 15%. (3) Hot-weather environment replacement a mount of fly-ash is a same of plan concrete setting period of form. Age 28day compression strength replacement a mount of fly-ash more hot-weather concrete then plan concrete.

Characterization of Glass Melts Containing Simulated Low and Intermediate Level Radioactive Waste

  • Jung, Hyun-Su;Kim, Ki-Dong;Lee, Seung-Heon;Kwon, Sung-Ku;Kim, Cheon-Woo;Park, Jong-Kil;Hwang, Tae-Won;Ahn, Zou-Sam
    • Journal of the Korean Ceramic Society
    • /
    • v.43 no.3 s.286
    • /
    • pp.148-151
    • /
    • 2006
  • In order to examine the process parameters for the vitrification of Low and Intermediate Level radioactive Waste (LILW) generated from nuclear power plants, measurements of several melt properties was performed for four selected glasses containing simulated waste. Electrical conductivity and viscosity were determined at temperatures ranging from 1123 to $1673^{\circ}C$. The temperature dependences of both properties in the molten state showed a similar behavior in which their values decrease as the temperature increases. The values of the electrical conductivity and viscosity at a temperature of 1423K adopted in an induction cold crucible melter process were $0.27{\sim}0.42$ S/cm and $9.8{\sim}42$ dPas, respectively.

Evaluation of Mitigation Effect of Upo-Swamp on the Air temperature Variation with Nighttime Cooling Rate (야간 냉각율을 이용한 우포늪의 기온변화 완화효과 평가)

  • Park, Myung-Hee;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.20 no.3
    • /
    • pp.309-319
    • /
    • 2011
  • In this study, we investigated the effects of Upo-swamp upon local thermal environment with nighttime cooling rate. To do this, we set up the AWS(Automatic Weather observation System) over the central part of Upo-swamp on the early October 2007. We conducted the study by comparing the AWS data with another weather data observed by several meteorological observations of the Korea Meteorological Administration located at the vicinity of Upo-swamp for one year. The air temperature of Upo-swamp was higher than that of the surrounding in cold-climate season. But it was opposite in warm-climate season. We confirmed that Upo-swamp roles to mitigate the daily and annual air temperature ranges. And the daily air temperature variation of Upo-swamp lagged behind the land one. This phenomenon represent that the heat reservoir capacity of Upo-swamp is much larger than that of the ground.

Trends in the effects of climate change on terrestrial ecosystems in the Republic of Korea

  • Choi, Sei-Woong;Kong, Woo-Seok;Hwang, Ga-Young;Koo, Kyung Ah
    • Journal of Ecology and Environment
    • /
    • v.45 no.3
    • /
    • pp.117-129
    • /
    • 2021
  • In this review, we aimed to synthesize the current knowledge on the observed and projected effects of climate change on the ecosystems of Korea (i.e., the Republic of Korea (ROK) or South Korea), as well as the main causes of vulnerability and options for adaptation in these ecosystems based on a range of ecological and biogeographical data. To this end, we compiled a set of peer-reviewed papers published since 2014. We found that publication of climate-related studies on plants has decreased in the field of plant phenology and physiology, whereas such publication has rapidly increased in plant and animal community ecology, reflecting the range shifts and abundance change that are occurring under climate change. Plant phenology studies showed that climate change has increased growing seasons by advancing the timing of flowering and budburst while delaying the timing of leafing out. Community ecology studies indicated that the future ranges of cold-adapted plants and animals could shrink or shift toward northern and high-elevation areas, whereas the ranges of warm-adapted organisms could expand and/or shift toward the areas that the aforementioned cold-adapted biota previously occupied. This review provides useful information and new insights that will improve understanding of climate change effects on the ecosystems of Korea. Moreover, it will serve as a reference for policy-makers seeking to establish future sectoral adaptation options for protection against climate change.

Molecular Cloning and Chaperone Activity of DnaK from Cold-adapted Bacteria, KOPRI22215

  • Sung, Min-Sun;Im, Ha-Na;Lee, Kyung-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.6
    • /
    • pp.1925-1930
    • /
    • 2011
  • Psychrophilic bacteria have acquired cold-resistance in order to protect themselves against freezing temperatures, which would otherwise be lethal. DnaK/DnaJ/GrpE systems are molecular chaperones which facilitate proper folding of newly synthesized proteins. Efficient folding processes are of great importance especially in a cold environment, such as the Arctic. In order to understand the protection mechanisms of psychrophilic bacteria against cold temperatures, we have explored a genome of KOPRI22215, tentatively identified as Psychromonas arctica, whose genome sequence has not yet been discovered. With an aim of searching for a coding gene of DnaK from KOPRI22215, we have applied a series of polymerase chain reactions (PCR) with homologous primers designed from other Psychromonas species and LA PCR in vitro cloning. 1917 bp complete coding sequence of dnaK from KOPRI22215 was identified including upstream promoter sites. Recombinant plasmids to overexpress PaDnaK along with EcDnaK (DnaK of E. coli) were then constructed in pAED4 vector and the pET-based system to induce PaDnaK expression by IPTG. Characterization assays of expressed PaDnaK were carried out by measuring survival rates upon 4 day incubation at 4 $^{\circ}C$: a refolding assay as molecular chaperone, and ATPase assay for functional activity. Taking account of all the data together, we conclude that PaDnaK was identified, successfully expressed, and found to be more efficient in providing cold-resistance for bacterial cells.