• Title/Summary/Keyword: coil number

Search Result 287, Processing Time 0.04 seconds

A study on the Development of the Shell-type Pole Transformer Using the Zig-Zag Winding (Zig-Zag 귄선에 의한 내철형 주상변압기 개발에 관한 연구)

  • Min, Yun-Hong;Shin, Dae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.121-128
    • /
    • 2007
  • In this thesis, we would show how to lay out and produce the shell-type transformer using the world's first Zig-Zag winding way, instead of a general winding. Also, we omit the progress of varnish-impregnation, so that we could develop the new shell-type transformer winding which improves the short-circuit characteristics and dielectric strength. It has a copernican effect to reduce the thickness and the number of insulation papers, as compared with a general winding transformer. We would prove that it is far superior in cost reduction, loss reduction, and mechanical force of short-circuit. And eventually you must find it useful in the pole transformer for power distribution in the domestic power companies.

Design and Evaluation of An Electromagnetic Driven Actuator for Near-field Optical Recording System (근접장 광기록 시스템용 전자기구동 액추에이터의 설계 및 평가)

  • 김석중;이용훈;이철우;서중언
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.11
    • /
    • pp.2732-2741
    • /
    • 2000
  • Combination of magnetic recording technology and optical recording technology such as Near Field Optical Recording is watched recently. In order to accomplish this technology, the development of an electromagnetic driven mm-sized mirror shifting laser beam in track direction have to needed. In Near Field Optical Recording System, shifting laser beam in track direction mean as fine tracking and means as coarse tracking. Therefore in Near Field Optical Recording, 2-stage actuator is composed of servo controller in reading or recording information on disc layer. In our research, through design and simulation process of driven mm-sized mirror, we arrange systematically design process of driven mm-sized mirror having good frequency transfer characteristics. Design and simulation processes included modal analysis of spring, calculation of magnetic moment according to the number of turns and geometric configuration of coil and magnetic circuit analysis meaning that calculation of magnetic flux density in air gap of magnetic circuit. After that we design and make parts of driven mm-sized mirror, assemble and evaluate our electriomagnetic driven mm-sized mirror. we compared design values with actual characteristic values and present solution scheme. Through these processes we performed manufacturing of an electromagnetic driven mm-sized mirror having good frequency-domain characteristics and high sensitivity characteristics.

A Study on the Characteristics of Discharge and Ozone Generation for Ozonizer of Neon Discharge Tube Type (네온방전관형 오존발생기의 방전특성 및 오존생성특성에 관한 연구)

  • Song, H.J.;Woo, S.H.;Kim, S.G.;Kim, K.C.;Lee, K.S.;Lee, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1857-1860
    • /
    • 1996
  • In this paper, ozonizer of neon discharge tube type( Neolamp ) by using silent discharge has been designed and manufactured. The discharge and ozone generation characteristics of Neolamp have been studied with variation of turn-on number( N ) of Neolamp, quality( Q ) and shape of external electrode. The discharge voltage is proportional to gap spacing of spiral external electrode( G ) for constant applied volatge. The discharge current is inversely proportional to G for constant applied volatge. The ozone concentration is inversely proportional to Q and G. Also, ozone concentration and generation are proportional to N. The sterilization characteristics of Escherichia coil have been obtained more than 97[%] at $1.30[mg/{\ell}]$ of liquid ozone concentration.

  • PDF

The Copper Rotor Die-casting of Single Phase Induction Motor and the Stator Design for Reducing Loss (단상유도전동기의 동 다이캐스팅과 손실 저감을 위한 고정자 설계)

  • Lee, Sang-Hoon;Kim, Ki-Chan;Kim, Kwang-Soo;Kim, Won-Ho;Kim, Soo-Yong;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.705-706
    • /
    • 2008
  • There has been, in recent years, effort to make cast copper rotors for industrial use of induction motors. Because the incorporation of copper for the conductor bars and end rings of the induction motor in place of aluminum would result in attractive improvements in motor energy efficiency. The purpose of this method is a reducing the copper loss as using higher conductivity of copper. In this paper as the single phase induction motor is studied, the stator slots and coil turn number is designed for adjusting the slot fill factor and improving its efficiency. At this time design is basis on calculation of reducing loss. And finally this paper shows that the before and after result is compared and analyzed.

  • PDF

Calculation of DC resistance of strand-to-strand joints for KSTAR (KSTAR 용 소선-소선 접합부의 직류저항 계산)

  • Ho-Jin Lee;Hyun-Il Nam;Ki-Baik Kim;Gye-Won Hong
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.104-110
    • /
    • 2001
  • Since the strand-to-strand type joint far CICC (Cable-In-Conduit Conductor) is small in size and has low DC resistance, it is expected to be useful type fur a superconducting magnet system which had a compact structure like the KSTAR (Korea Superconducting Tokamak Advanced Research) coil system. The DC resistance is changed according to the distribution patterns of strands in cables connected together in the joint. A commercial code was used for the calculation of the DC resistance. With the decrease of outer diameter of the Joint, Which means the increase of strand volume fraction in the joint, the calculated DC resistance decrease rapidly and non-lineally. The variation of resistance depends mainly on the volume fraction of solder which has higher resistivity than copper. The resistance decrease inversely with the increase of the length of the joint. The resistance increase with increase of number of triplets in each stack contacted with that of another terminal cable. In case of the strand-to-strand joint that has 62mm of outer diameter, 52mm of inner diameter, 100mm of overlap length, and four triplets in each stack, the calculated DC resistance is less than 1 n-Ohm.

  • PDF

Turn-to-Turn Dielectric Characteristics of Coils for HTSFCL (고온초전도 한류기용 코일의 턴간 절연 특성)

  • Baek, Seung-Myeong;Joung, Jong-Man;Lee, Chang-Hwa;Nguyen, Van Dung;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.15-18
    • /
    • 2003
  • Fault current limiters (FCL) are extensively needed to suppress fault currents, especially for trunk power systems heavily connected to high voltage/large current transmission lines. Due to its ideal electrical behavior, high-temperature superconductor fault current limiter (HTSFCL) becomes one of the most important developing trends of limiters in power system. This paper describes the result of an investigation of the dielectric characteristics of turn-to-turn insulation for pancake and solenoid type reactor coil in liquid nitrogen. The influence of thickness in a variety length, on AC, DC and impulse surface flashover has been investigated. Also, the relationships between the number of turn and breakdown characteristics were clarified. The information gathered in this test series should be helpful in the design of liquid nitrogen filled DC reactor type HTSFCL.

  • PDF

Preparation and Characterization of Nanoparticles Using Poly(N-isopropylacrylamide)-$Poly({\varepsilon}-caprolactone)$ and Poly(ethylene glycol)-$Poly({\varepsilon}-caprolactone)$ Block Copolymers with Thermosensitive Function

  • Choi, Chang-Yong;Jang, Mi-Kyeong;Nah, Jae-Woon
    • Macromolecular Research
    • /
    • v.15 no.7
    • /
    • pp.623-632
    • /
    • 2007
  • Thermosensitive nanoparticles were prepared via the self-assembly of two different $poly({\varepsilon}-caprolactone)$-based block copolymers of poly(N-isopropylacrylamide)-b-$poly({\varepsilon}-caprolactone)$ (PNPCL) and poly(ethylene glycol)-b-$poly({\varepsilon}-caprolactone)$ (PEGCL). The self-aggregation and thermosensitive behaviors of the mixed nanoparticles were investigated using $^1H-NMR$, turbidimetry, differential scanning microcalorimetry (micro-DSC), dynamic light scattering (DLS), and fluorescence spectroscopy. The copolymer mixtures (mixed nanoparticles, M1-M5, with different PNPCL content) formed nano-sized self-aggregates in an aqueous environment via the intra- and/or intermolecular association of hydrophobic PCL chains. The microscopic investigation of the mixed nanoparticles showed that the critical aggregation concentration (cac), the partition equilibrium constants $(K_v)$ of pyrene, and the aggregation number of PCL chains per one hydrophobic microdomain varied in accordance with the compositions of the mixed nanoparticles. Furthermore, the PNPCL harboring mixed nanoparticles evidenced phase transition behavior, originated by coil to the globule transition of PNiPAAm block upon heating, thereby resulting in the turbidity change, endothermic heat exchange, and particle size reduction upon heating. The drug release tests showed that the formation of the thermosensitive hydrogel layer enhanced the sustained drug release patterns by functioning as an additional diffusion barrier.

In-Stent Stenosis of Stent Assisted Endovascular Treatment on Intracranial Complex Aneurysms

  • Yoon, Kyeong-Wook;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.6
    • /
    • pp.485-489
    • /
    • 2010
  • Objective : To introduce the frequency and segment analysis of in-stent stenosis for intracranial stent assisted endovascular treatment on complex aneurysms. Methods : A retrospective study was performed in 158 patients who had intracranial complex aneurysms and were treated by endovascular stent application with or without coil embolization. Of these, 102 patients were evaluated with catheter based angiography after 6, 12, and 18 months. Aneurysm location, using stent, time to stenosis, stenosis rate and narrowing segment were analyzed. Results : Among follow-up cerebral angiography done in 102 patients, 8 patients (7.8%) were shown an in-stent stenosis. Two patients have unruptured aneurysm and six patients have ruptured one. Number of Neuroform stents were 7 cases (7.5%) and Enterprise stent in 1 case (11.1%). Six patients demonstrated in-stent stenosis at 6 months after stent application and remaining two patients were shown at 12 months, 18 months, respectively. Conclusion : In-stent stenosis can be confronted after intracranial stent deployment. In our study, no patient showed symptomatic stenosis and there were no patients who required to further treatment except continuing antiplatets medication. In-stent stenosis has been known to be very few when they are placed into the non-pathologic parent artery during the complex aneurysm treatment, but the authors found that it was apt to happen on follow up angiography. Although the related symptom was not seen in our cases, the luminal narrowing at the stented area may result the untoward hemodynamic event in the specific condition.

Arc-Extinguishing Characteristics of A Rotary-Arc Gas Circuit Breaker (자력소호 가스차단부의 소호특성)

  • Shin, Young-June;Park, Kyong-Yop;Song, Ki-Dong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1593-1598
    • /
    • 1994
  • Recently rotary-arc, thermal expansion and their composite interrupters are widely used in the distribution power system because they have lots of advantages in making the larger interrupting capacity, the smaller size, the lighter weight and the less surge. A model interrupter of rotary-arc type, which has constant stroke and thermal expansion volume, was studied by varying the design parameters, i.e. the number of turns of the driving coil, the inner diameter of the moving contact, the gas pressure and the shape of the fixed contact for this project. Short cicuit current interrupting tests were conducted to the model interrupters by varying the requirements from 42% to 175% of the test voltage, interrupting current and transient recovery voltage for the test duty No.4 of 7.2kV 12.5kA single phase test. The pressure rise, minimum and maximum arcing times were analyzed for each model interrupter. All types of model interrupters showed good interrupting performances and sufficient design margins for the ratings.

  • PDF

MUSIC-based Diagnosis Algorithm for Identifying Broken Rotor Bar Faults in Induction Motors Using Flux Signal

  • Youn, Young-Woo;Yi, Sang-Hwa;Hwang, Don-Ha;Sun, Jong-Ho;Kang, Dong-Sik;Kim, Yong-Hwa
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.288-294
    • /
    • 2013
  • The diagnosis of motor failures using an on-line method has been the aim of many researchers and studies. Several spectral analysis techniques have been developed and are used to facilitate on-line diagnosis methods in industry. This paper discusses the first application of a motor flux spectral analysis to the identification of broken rotor bar (BRB) faults in induction motors using a multiple signal classification (MUSIC) technique as an on-line diagnosis method. The proposed method measures the leakage flux in the radial direction using a radial flux sensor which is designed as a search coil and is installed between stator slots. The MUSIC technique, which requires fewer number of data samples and has a higher detection accuracy than the traditional fast Fourier transform (FFT) method, then calculates the motor load condition and extracts any abnormal signals related to motor failures in order to identify BRB faults. Experimental results clearly demonstrate that the proposed method is a promising candidate for an on-line diagnosis method to detect motor failures.