• 제목/요약/키워드: coil loss

검색결과 206건 처리시간 0.026초

과도서지를 이용한 가속열화 시험법에 따른 견인전동기 고정자 코일의 전기적 특성 변화 (Properties of Electrical Performance on Stator Coil of Traction Motor by Accelerated lest using Transient Surge)

  • 박현준;장동욱;이길헌;최종선;김저우
    • 한국전기전자재료학회논문지
    • /
    • 제16권9호
    • /
    • pp.783-789
    • /
    • 2003
  • The winding problems of traction motor are the major determinant of motor's life. The root cause of winding failure is gradual deterioration of the insulation due to thermal, electrical, mechanical and environmental stresses. The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking, the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss(tan$\sigma$), capacitance and partial discharge. The method of diagnosis is able to analyze the insulation condition and evaluate the life of the traction motor.

Analyzed Model of The Active Filter combined with SMES

  • Kim A-Rong;Kim Jae-Ho;Kim Hae-Jong;Kim Seok-Ho;Seong Ki-Chul;Park Min-Won;Yu In-Keun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권2호
    • /
    • pp.20-24
    • /
    • 2006
  • Recently, utility network is becoming more and more complicated and huge due to IT and OA devices. In addition to, demands of power conversion devices which have non-linear switching devices are getting more and more increased. Consequently, because of the non-linear power semiconductor devices, current harmonics are unavoidable. Sometimes those current harmonics flow back to utility network and become one of the main reasons which can make the voltage distortion. Also, it makes noise and heat loss. On the other hands, voltage sag from sudden increasing loads is also one of the terrible problems inside of utility network. In order to compensate the current harmonics and voltage sag problem, AF(active filter) systems could be a good solution method. SMES is a very good promising source due to it's high response time of charge and discharge. Therefore, the combined AF and SMES system can be a wonderful device to compensate both harmonics current and voltage sag. However, SMES needs a superconducting magnetic coil. Because of using this superconducting magnetic coil, quench problem caused by unexpected reasons have always been unavoidable. Therefore, to solve out mentioned above, this paper presents a decisive method using shunt and series active filter system combined with SMES. Especially, authors analyzed the change of original energy capacity of SMES regarding to the size of resistance caused by quench of superconducting magnetic coil.

고온초전도 혼합적층선재의 외부자장 변화에 따른 손실 특설 (Characteristics of AC loss of Hybrid Multi-Stacking with HTS Wires in External Magnetic Field)

  • 임형우;이동민;윤기현;차귀수;이희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.71-73
    • /
    • 2006
  • AC loss on variation of external magnetic field is a very important factor in development of power applications. In this paper, we measured and compared AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires and uniform-multi-stacked wire made of one type of wires, 1G wires or 2G wires. Measurement was performed using by the linked-picked coil method. As results, as the number of wires increase, AC loss per unit volume of both stacked wires in low external magnetic field is reduced. Also AC loss of 2G slacked wire is higher than that of 1G wire. AC loss per unit length of 2G stacked wire is less than that of 1G stacked wire. And AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires was between uniform-multi-stacked wire made of 1G wires and 2G wires.

  • PDF

Eddy Loss Analysis and Parameter Optimization of the WPT System in Seawater

  • Zhang, Ke-Han;Zhu, Zheng-Biao;Du, Luo-Na;Song, Bao-Wei
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.778-788
    • /
    • 2018
  • Magnetic resonance wireless power transfer (WPT) in the marine environment can be utilized in many applications. However, energy loss in seawater through eddy loss (EL) is another consideration other than WPT in air. Therefore, the effect of system parameters on electric field intensity (EFI) needs to be measured and ELs calculated to optimize such a system. In this paper, the usually complicated analytical expression of EFI is simplified to the product of frequency, current, coil turns, and a coefficient to analyze the eddy current loss (ECL). Moreover, as the calculation of ECL through volume integral is time-consuming, the equivalent eddy loss impedance (EELI) is proposed to help designers determine the optimum parameters quickly. Then, a power distribution model in seawater is conceived based on the introduction of EELI. An optimization flow chart is also proposed according to this power distribution model, from which a prototype system is developed which can deliver 100 W at 90% efficiency with a gap of 30 mm and a frequency of 107.1 kHz.

A Study on Power Stability Improvement in the Inductive Coupled RFID Transponder System

  • Kim, Gi-Rae;Choi, Young-Kyu
    • Journal of information and communication convergence engineering
    • /
    • 제5권2호
    • /
    • pp.150-154
    • /
    • 2007
  • Transponders of RFID system are classified as active or passive depending on the type of power supply they use. In passive transponders the data carrier has to obtain its power from the induced voltage. The induced voltage is converted into direct current using a low loss bridge rectifier and then smoothed. In practice, the induced voltage in the transponder coil is variable according to the coupling coefficient k and the load resistance ($R_L$). Therefore, the rectified voltage is unstable and the transponder of RFID is unstable sometimes. In this paper, a voltage-dependent shunt resistor ($R_s$) circuits are designed and inserted in parallel with the load resistance of RFID transponder in order to improve the stability of power.

Coil-Capacitor Circuit Design of a Transcutaneous Energy Transmission System to Deliver Stable Electric Power

  • Choi, Seong-Wook;Lee, Min-Hyong
    • ETRI Journal
    • /
    • 제30권6호
    • /
    • pp.844-849
    • /
    • 2008
  • A new transcutaneous energy transmission (TET) system was developed for transmitting electrical power to an implanted device, such as an artificial heart in a patient's body. This new design can maintain a stable output voltage independent of the load resistance. The system includes a compensation capacitor to reduce energy loss and increase power transfer efficiency. Experimental results show that the output voltage of the receiving coil changes very little as the load resistance varies from 14.8 ${\Omega}$ to 15 $k{\Omega}$, which corresponds to a change in output power from 0.1 to 97 W.

  • PDF

유한 요소 해석을 통한 자기변형 구동기 자기 회로 설계 (The design of magnetic circuit of magnetostrictive actuator using finite element method)

  • 이석호;박영우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.548-551
    • /
    • 2004
  • Magnetostrictive actuators have seen increasing use in fine positioning system because it has many advantages such as friction free, resolution of ${\mu}{\textrm}{m}$ or nm scale, and powerful output force. Usually, the magnetic circuit of magnetostrictive actuator has components which are flux return path, coil, and magnetostrictive material. It is classified in two types according to existence of the permanent magnet. The magnetic circuit having optimal performances transfer magnetic field which is obtained by providing input current at coil without energy loss. This paper described mathematical model of magnetic circuit for getting design variables. The modeling equation is obtained from the relations between flux and reluctance of the magnetic equivalent circuit. Also, finite element analysis has been used to study the performance of magnetic circuit according to change of design variables such as existence and shape of the permanent magnet, flux return path etc. The modification of dimensions enables us to optimize magnetic circuit.

  • PDF

주상용 몰드변압기의 온도분포 해석과 온도상승 시험 (The Temperature Distribution Analysis and Temperature Rise Test of Pole Mold Transformer)

  • 조한구;이운용;김석수;이종득
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.780-782
    • /
    • 2001
  • The mold transformer has anti-burnt and possibility of small size contrary to oil-immersed transformer. The mold transformer has generally cooling duct between low voltage coil and high voltage coil and also made by one body molding for small size and low loss. In this paper, the temperature distribution of designed 50kVA pole mold transformer for power distribution is investigated by FEM program. The designed transformer is also manufactured and temperature rise test is carried out.

  • PDF

전자장 해석 프로그램을 이용한 와전류 문제의 해석 및 이해 (Analysis and Understanding of Eddy Current Problem using electromagnetic field Packeg)

  • 임건규;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2203-2204
    • /
    • 2006
  • When the coil with alternating current approaches to the conductor the eddy current flows in conductor. Eddy current is concentrated on the conductor surface and decrescent because of skin effet.. In this paper investigated eddy current characteristic that is happened in conductor. Analyzed characteristic using electromagnetic field finite element analysis program that is commercialized to analyze value of eddy current and penetration depth. Analyzed creation value of eddy current and penetration depth in conductor that change operation frequency and the material of conductor, coil outside diameter, inside diameter, position, type of conductor from analyzed eddy current characteristic. The results. using distribution of eddy current and penetration depth data is that will help to forecast ECT(Eddy Current Testing), Eddy current application and use field, eddy current loss.

  • PDF

전자장 해석 프로그램을 이용한 와전류 문제의 해석 및 이해 (Analysis and Understanding of Eddy Current Problem using electromagnetic field Packeg)

  • 임건규;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.571-572
    • /
    • 2006
  • When the coil with alternating current approaches to the conductor the eddy current flows in conductor. Eddy current is concentrated on the conductor surface and decrescent because of skin effet.. In this paper investigated eddy current characteristic that is happened in conductor. Analyzed characteristic using electromagnetic field finite element analysis program that is commercialized to analyze value of eddy current and penetration depth. Analyzed creation value of eddy current and penetration depth in conductor that change operation frequency and the material of conductor, coil outside diameter, inside diameter, position, type of conductor from analyzed eddy current characteristic. The results, using distribution of eddy current and penetration depth data is that will help to forecast ECT(Eddy Current Testing), Eddy current application and use field, eddy current loss.

  • PDF