• Title/Summary/Keyword: coil

Search Result 3,847, Processing Time 0.049 seconds

Separation Inverter Noise and Detection of DC Series Arc in PV System Based on Discrete Wavelet Transform and High Frequency Noise Component Analysis (DWT 및 고주파 노이즈 성분 분석을 이용한 PV 시스템 인버터 노이즈 구분 및 직렬 아크 검출)

  • Ahn, Jae-Beom;Jo, Hyun-Bin;Lee, Jin-Han;Cho, Chan-Gi;Lee, Ki-Duk;Lee, Jin;Lim, Seung-Beom;Ryo, Hong-Je
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.271-276
    • /
    • 2021
  • Arc fault detector based on multilevel DWT with analysis of high-frequency noise components over 100 kHz is proposed in this study to improve the performance in detecting serial arcs and distinguishing them from inverter noise in PV systems. PV inverters generally operate at a frequency range of 20-50 kHz for switching operation and maximum power tracking control, and the effect of these frequency components on the signal for arc detection leads to negative arc detection. High-speed ADC and multilevel DWT are used in this study to analyze frequency components above 100 kHz. Such high frequency components are less influenced by inverter noise and utilized to detect as well as separate DC series arc from inverter noise. Arc detectors identify the input current of PV inverters using a Rogowski coil. The sensed signal is filtered, amplified, and used in 800kSPS ADC and DWT analysis and arc occurrence determination in DSP. An arc detection simulation facility in UL1699B was constructed and AFD tests the proposed detector were conducted to verify the performance of arc detection and performance of distinction of the negative arc. The satisfactory performance of the arc detector meets the standard of arc detection and extinguishing time of UL1699B with an arc detection time of approximately 0.11 seconds.

Evaluation of Usefulness for Diagnosis of Lung Cancer on Integrated PET-MRI Using Decision Matrix (판정행렬을 기반한 일체형 PET-MRI의 폐암 진단 유용성 평가)

  • Kim, Jung-Soo;Yang, Hyun-Jin;Kim, Yoo-Mi;Kwon, Hyeong-Jin;Park, Chanrok
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.635-643
    • /
    • 2021
  • The results of empirical researches on the diagnosis of lung cancer are insufficient, so it is limited to objectively judge the clinical possibility and utilization according to the accuracy of diagnosis. Thus, this study retrospectively analyzed the lung cancer diagnostic performance of PET-MRI (Positron Emission Tomography-Magnetic Resonance Imaging) by using the decision matrix. This study selected and experimented total 165 patients who received both hematological CEA (Carcinoembryonic Antigen) test and hybrid PET-MRI (18F-FDG, 5.18 MBq/kg / Body TIM coil. VIVE-Dixon). After setting up the result of CEA (positive:>4 ㎍/ℓ. negative:<2.5㎍/ℓ) as golden data, the lung cancer was found in the image of PET-MRI, and then the SUVmax (positive:>4, negative:<1.5) was measured, and then evaluated the correlation and significance of results of relative diagnostic performance of PET-MRI compared to CEA through the statistical verification (t-test, P>0.05). Through this, the PET-MRI was analyzed as 96.29% of sensitivity, 95.23% of specificity, 3.70% of false negative rate, 4.76% of false positive rate, and 95.75% of accuracy. The false negative rate was 1.06% lower than the false positive rate. The PET-MRI that significant accuracy of diagnosis through high sensitivity and specificity, and low false negative rate and false positive rate of lung cancer, could acquire the fusion image of specialized soft tissue by combining the radio-pharmaceuticals with various sequences, so its clinical value and usefulness are regarded as latently sufficient.

CFD on the possibility of performance evaluation of heat pump outdoor unit in duct-type constant temperature chamber (덕트형 항온챔버에서 히트펌프 실외기의 성능평가 가능성에 대한 CFD)

  • Kim, Jong-Ryeol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.116-121
    • /
    • 2021
  • A lot of research is being done to develop a high-efficiency heat pump to save energy, and research to reduce or eliminate the phenomenon of frost occurring in the outdoor unit coil is also being conducted at the same time. A curved constant temperature chamber was constructed that can be tested under the same conditions as in the natural state so that the research can be conducted in which frost does not occur on the outdoor unit of the heat pump regardless of the season. Simulations were performed to verity whether such a curved constant temperature chamber has feasibility as an experimental device. For CFD conditions, the length of the straight duct in front of the outdoor unit located in the duct-type constant temperature chamber was 1, 5, 10 and 15 times the diameter of the duct. As a result, it was found that a straight space must be secured 10 times the diameter of the duct.

Operating Frequency Design for Stable Initial Operation of Loosely Coupled Resonant DAB Converter (Loosely Coupled Resonant DAB 컨버터의 안정적인 초기 구동을 위한 동작 주파수 설계)

  • Baek, Seung-Hyuk;Kim, Sungmin;Lee, Jaehong;Lee, Seung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.6
    • /
    • pp.437-445
    • /
    • 2021
  • This paper proposes an operating frequency design method that limits the voltage applied to aload-side converter during the initial operation of a loosely coupled resonant dual-active bridge (LCR-DAB) converter and an initial operating strategy that applies it. The LCR-DAB converter uses two wireless power transfer coils instead of the high-frequency transformer of the general DAB converter. The wireless power coil has a physical distance of several tens of millimeter or more between the two coils; thus, the LCR-DAB converter is a bidirectional isolated power conversion system that can easily achieve high insulation performance. However, for the initial operation of the LCR-DAB, if the power-side converter is operated at the resonance frequency while the load-side converter is not operating, then a very high voltage due to resonance is applied to the load-side converter, thereby causing damage to the converter. Therefore, a method that can stably charge the DC link voltage of the secondary-side converter during the initial operation is needed. This paper proposes a method to initially charge the secondary-side DC link by operating the primary-side converter at a frequency with limited voltage gain rather than at a steady-state operating frequency. The validity of the proposed frequency design method and initial operating sequence is verified through simulation and experimentation of the 1 KW LCR-DAB converter.

Evaluation of electromechanical properties in REBCO CC tapes under transverse compression using anvil test method

  • Diaz, Mark Angelo;Shin, Hyung-Seop
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.57-61
    • /
    • 2022
  • One of the major applications of REBCO coated conductor (CC) tapes is in superconducting magnets or coils that are designed for high magnet fields. For such applications, the CC tapes were exposed to a high level of stresses which includes uniaxial tensile or transverse compressive stresses resulting from a large magnetic field. Thus, CC tapes should endure such mechanical load or deformation that can influence their electromechanical performance during manufacturing, cool-down, and operation. It has been reported that the main cause of critical current (Ic) degradation in CC tapes utilized in coil windings for superconducting magnets was the delamination due to transversely applied stresses. In most high-magnetic-field applications, the operating limits of the CC tapes will likely be imposed by the electromechanical properties together with its Ic dependence on temperature and magnetic field. In this study, we examined the influence of the transverse compressive stress on the Ic degradation behaviors in various commercially available CC tapes which is important for magnet design Four differently processed REBCO CC tapes were adopted to examine their Ic degradation behaviors under transverse compression using an anvil test method and a newly developed instantaneous Ic measurement system. As a result, all REBCO CC tapes adopted showed robustness against transverse compressive stresses for REBCO coils, notably at transverse compressive stresses until 250 MPa. When the applied stress further increased, different Ic degradation behaviors were observed depending on the sample. Among them, the one that was fabricated by the IBAD/MOCVD process showed the highest compressive stress tolerance.

Heat transfer performance of a helical heat exchanger depending on coil distance and flow guide for supercritical cryo-compressed hydrogen

  • Cha, Hojun;Choi, Youngjun;Kim, Seokho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.62-67
    • /
    • 2022
  • Liquid hydrogen (LH2) has a higher density than gaseous hydrogen, so it has high transport efficiency and can be stored at relatively low pressure. In order to use efficient bulk hydrogen in the industry, research for the LH2 supply system is needed. In the high-pressure hydrogen station based on LH2 currently being developed in Korea, a heat exchanger is used to heat up supercritical hydrogen at 700 bar and 60 K, which is pressurized by a cryogenic high-pressure pump, to gas hydrogen at 700 bar and 300 K. Accordingly, the heat exchanger used in the hydrogen station should consider the design of high-pressure tubes, miniaturization, and freezing prevention. A helical heat exchanger generates secondary flow due to the curvature characteristics of a curved tube and can be miniaturized compared to a straight one on the same heat transfer length. This paper evaluates the heat transfer performance through parametric study on the distance between coils, guide effect, and anti-icing design of helical heat exchanger. The helical heat exchanger has better heat transfer performance than the straight tube exchanger due to the influence of the secondary flow. When the distance between the coils is uniform, the heat transfer is enhanced. The guide between coils increases the heat transfer performance by increasing the heat transfer length of the shell side fluid. The freezing is observed around the inlet of distribution tube wall, and to solve this problem, an anti-icing structure and a modified operating condition are suggested.

Design of a Smart Safety Vest Incorporated With Metal Detector Kits for Enhanced Personal Protection

  • Rajendran, Salini D.;Wahab, Siti N.;Yeap, Swee P.
    • Safety and Health at Work
    • /
    • v.11 no.4
    • /
    • pp.537-542
    • /
    • 2020
  • Background: Personal protective equipment (PPE) has been designed in such a way to reduce accident rates. Unfortunately, existing PPE is rather ineffective as it is not able to provide warning signals when hazard is around. The integration of intelligent systems is envisaged to increase the efficiency of existing PPE. Methods: This project designed a safety vest incorporated with metal detectors which can provide immediate warning to the field workers when there is metal hazard around. This product has greater freedom of design via smart manufacturing as it involves the assembly of few commercially available parts into a single entity. Briefly, the metal detector is a do it yourself (DIY) kit, and the safety vest is purchasable from any local market. The DIY kit was connected to a copper coil and being sewed into the safety vest. Results: The metal detector induces beeping sound when there is metal hazard around. A total of 121 engineering students were introduced to the prototype before being requested to answer a survey associated with the design. Respondents have rated >3.00/5.00 for the design simplicity, ease of usage, and light weight. Meanwhile, respondents suggested that the design should be further improved by increasing the metal detection range. Conclusion: It is envisaged that the introduction of this smart safety vest will allow the workers to carry out their duties securely by reducing the accident rates. Particularly, such design is expected to reduce workplace accident especially during night time at construction sites where the visibility is low.

A comparison of different O-antigen serogroups of Escherichia coli in semen samples of fertile and infertile men

  • Nabi, Ali;Khalili, Mohammad Bagher;Eslami, Gilda;Vakili, Mahmood;Anbari, Fatemeh;Torki, Alireza
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.49 no.1
    • /
    • pp.33-39
    • /
    • 2022
  • Objective: Male genital tract infections have been associated with infertility, and Escherichia coli has drawn increasing attention as an important bacterium in this context. This investigation aimed to characterize and compare the distributions of O-antigen serogroups of E. coli in the semen samples of fertile and infertile men. Methods: In this case-control study, semen samples were collected from 618 fertile and 1,535 infertile men. The E. coli-positive samples were evaluated in terms of concentration, morphology, viability, and motility parameters according to the World Health Organization 2010 guidelines. Finally, different serogroups of E. coli were identified by multiplex polymerase chain reaction targeting the O-antigen variations of the bacterium. Results: The prevalence of E. coli among fertile men was significantly higher than among infertile men (p<0.001). The sperm morphology, viability, and motility in the E. coli-positive fertile group were significantly higher than in the E. coli-positive infertile group (p<0.001). E. coli O6 was the most prevalent serogroup found in both groups. However, there was no significant difference in the frequency of different serogroups of E. coil between the two groups (p=0.55). Conclusion: Despite the higher prevalence of E. coli among fertile men, E. coli had more detrimental effects on semen parameters in infertile men. There was no significant difference in E. coli serogroups between the fertile and infertile groups.

Effect of extraction conditions on the stability and safety of sericin

  • Ji Hae, Lee;Hyun-Bok, Kim;HaeYong, Kweon
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.45 no.2
    • /
    • pp.93-98
    • /
    • 2022
  • To assess the feasibility of silk sericin for non-textile application, the storage stability and biological safety of sericin were examined. It was extracted at 37℃, 70℃, 100℃, and 121℃ for 1, 3, and 5 h to elucidate the effect of extraction condition on the stability and safety of silk sericin. The solubility was increased till approximately 26% with extraction temperature of 121℃ for 1 h. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) showed that the molecular weight distribution depended on the extraction conditions. Extracted sericin displayed typical UV absorption bands upon spectrometric analysis. To examine the reproducibility of its obtained conformation, sericin was extracted thrice and its circular dichroism (CD) spectra was measured each time. Most CD spectra showed reproducibility regardless of temperature and time except under 100℃ extraction condition. The diversity of CD spectrum showed gradual reduction and was finally coincident with extraction time from 1 to 5 h. Notably, sericin has a negative peak of approximately 200 nm attributed to random coil conformation, regardless of extraction condition. However, at the 100℃ extraction condition, sericin showed both bands to be negative bands of approximately 200 and 220 nm, respectively. Sericin was centrifuged to determine the stability of storage conditions. The sericin extracted at 100℃ and 121℃ for 1 h was found to form gel rapidly within 1 h, but at 121℃ condition, the gel fraction was approximately 20% within 1 h which retained its phase regardless of storage time. The gel fraction of sericin extracted at 100℃ for 5 h increased with time, however at the 121℃ for 5 h condition, the gel fraction was measured to be less than 10% regardless of increase in storage time. PetriflimTM AC plates test showed that sericin was safe from aerobic bacteria activity by extraction under high temperature.

Use of a Rigid-Tipped Microguidewire for the Endovascular Treatment of Cavernous Sinus Dural Arteriovenous Fistulas with an Occluded Inferior Petrosal Sinus

  • Deniwar, Mohamed Adel;Kwon, Boseong;Song, Yunsun;Park, Jung Cheol;Lee, Deok Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.5
    • /
    • pp.688-696
    • /
    • 2022
  • Objective : Transvenous embolization (TVE) via an occluded inferior petrosal sinus (IPS) in a cavernous sinus dural arteriovenous fistula (CSDAVF) is challenging, often requiring navigation of a microcatheter through resistive obstacles between the occluded IPS and shunted pouch (SP), although the reopening technique was successfully performed. We report five cases of successful access to the cavernous sinus (CS) or SP using the rigid-tipped microguidewire such as chronic total occlusion (CTO) wire aiming to share our initial experience with this wire. Methods : In this retrospective study, four patients with CSDAVF underwent five procedures using the CTO wire puncture during transfemoral transvenous coil embolization. Puncture success, shunt occlusion, and complications including any hemorrhage and cranial nerve palsy were evaluated. Results : Despite successful access through the occluded IPS, further entry into the target area using neurointerventional devices was impossible due to a short-segment stricture before the CS (three cases) and a membranous barrier within the CS (two cases). However, puncturing these structures using the rigid-tipped microguidewire was successful in all cases. We could advance the microcatheter over the rigid-tipped microguidewire for the navigation to the SP and achieved complete occlusion of the SP without complications. Conclusion : The use of the rigid-tipped microguidewire in the TVE via the occluded IPS of the CSDAVF would be feasible and safe.