• 제목/요약/키워드: coil

검색결과 3,839건 처리시간 0.052초

악관절의 자기공명영상과 시상단층 방사선촬영상에 관한 비교연구 (A COMPARATIVE STUDY ONMAGNETIC RESONANCE IMAGE AND SECTOGRAPH OF HUMAN TNJ)

  • 이성복;최대균;최부병
    • 대한치과보철학회지
    • /
    • 제31권2호
    • /
    • pp.249-270
    • /
    • 1993
  • For understanding of anatomy, physiology, and diseases of human TMJ, it is required to evaluate quantitatively the movement of the disc and condyle head of mandible. The histologic section of cadaver TMJ were examined, and the magnification of the MR image and its details of anatomy were evaluated. And then a quantitative analytic method, by comparing the Sectograph and the MR image of vital human TMJ, was proposed. For this study, 15 subjects(Male, 24~35years) were selected from a prosthodontic examination randomly, and each subject’s five interocclusal rubber registration records were made on the ICP, and 5, 10, 15, and 20mmjaw opening positions. All subjects were radiographed with a Denar Quint Sectograph Image System(Denar Corp., USA), and imaged with a MRP-20EX MR Image System(0.2T, Permanent Magnet Type, Hitachi Medical Corp., Japan) using an 100mm diameter bilateral type surface coil. These images were traced on the acetate tracing paper, and analyzed In this study, the findings led to the following conclusions. 1. In comparison of the histologic section of autopsy specimen with the MR image at the same section, the size(dimension) of MR image was 70% of the real one. It was possible to recognize the shape of articular disc, anterior and posterior attachments, and adjacent soft tissues, because of the excellent reproducibility of anatomical structure. 2. When we compared the amount of joint space on MR image with that of joint space on sectograph, the amount of joint space on sectograph was significantly greater than that of joint space on MR image, except at the top of condylar head. 3. The position of minimum joint space on sectograph at intercuspal position didn't coincide with the middle position of articular disc on MR image, and was approximately in the anterior third of posterior band of articular disc. 4. The amount of condylar movement on MR image at opening movement was greater than that of articular disc movement. From Intercuspal position to 5mm jaw-opening movement, the condylar movement showed hinge one, and over the range 5mm jaw-opening it suggested hinge & translatory one. 5. In terms of area variation of articular disc measured on MR image in sagittal plane, the area of posterior band increased with increasing the amount of Jaw opening, but the area of anterior band decreased conversely.

  • PDF

나선형 튜브내의 난류 열전달에 대한 수치적 연구 (Numerical Study of Turbulent Heat Transfer in Helically Coiled Tubes)

  • 윤동혁;박주엽;설광원
    • 대한기계학회논문집B
    • /
    • 제36권8호
    • /
    • pp.783-789
    • /
    • 2012
  • 본 연구에서는 나선형 튜브내의 난류 열전달 및 하중 특성을 수치해석 방법을 이용하여 파악하였다. 열교환기와 같은 공학적 설비에서 관내 열전달을 향상시키기 위해 튜브의 형상을 나선형으로 설계한다. 이에 나선형 튜브내의 열전달 및 난류 특성에 대한 많은 실험적 연구가 이루어 졌으나, 대부분의 연구가 압력 강하 및 열전달 상관관계에 초점이 맞추어 진행되었다. 나선형 튜브내의 유동은 원심력에 의해 튜브 바깥쪽에서는 상대적으로 높은 열전달 및 전단응력이 발생하지만, 안쪽에서는 낮은 열전달 및 전단응력이 발생하게 된다. 따라서 본 연구에서는 튜브의 원주방향으로 발생하는 전단 응력 및 Nusselt 수의 변화를 Reynolds 수와 나선 코일의 지름을 변경하며 정량적으로 살펴보았다. 나선 코일 안쪽에서 국부적인 전단응력과 열전달율이 크게 낮게 특정되었으며, 이는 튜브 재질의 안정성에 영향을 미칠 것으로 판단되었다. 또한 본 연구에서는 마찰계수와 Nusselt 수에 대한 기존 상관관계식을 검증하였으며, 직관에서의 마찰계수와 Nusselt 수의 상관관계식이 나선형 튜브의 형상에도 적용될 수 있음을 관측하였다. 본 연구의 결과는 열교환기나 증기발생기의 안전성 평가를 위해 중요한 데이터로 활용될 수 있을 것이다.

슬관절 수술용 전기소작완드에 적용되는 형상기억합금 코일스프링의 회복력 및 행정거리의 관계 (Relationship between Restoring Force and Typical Stroke with SMA Coil Spring in Electrosurgical Knee Wand)

  • 양영규;한기봉;김철웅
    • 대한기계학회논문집B
    • /
    • 제35권12호
    • /
    • pp.1301-1307
    • /
    • 2011
  • 슬관절 소작용 완드(Electrosurgical Knee Wand, EKW)는 고주파 소작법으로 슬관절 인대, 조직 등의 응고, 삭마, 절제, 등에 적용된다. EKW와 radiofrequency를 이용한 조직응고, 삭마 등의 슬관절 수술에서 수술안전성, 편의성 및 성공률을 극대화하기 위해서는 병변에 매우 정확하고 안전하게 EKW가 선택적 접근을 할 수 있도록 유도하는 탁월한 방향조종제어능이 핵심기술이다. 따라서 본 연구에서는 대퇴경골부 제한적인 공간에서 가장 적합한 수술용 의료기기 액추에이터로 판단되는 형상기억합금(SMA) 와이어를 이용하여 형상기억효과를 극대화 할 수 있는 SMA 인장스프링 모델을 제작하여 실험을 수행하였다. 또한 SMA의 열전기적 특성 및 전류변화에 따른 온도특성에 대한 연구를 수행하고 SMA 인장스프링의 설계조건에 따른 회복력 및 행정거리의 관계를 평가하였다. 그 결과, SMA 인장스프링의 직경이 작아질수록 최대온도는 증가하였다. 전류인가 15초의 경우는 전류량 증가와 힘의 증가가 비례한 반면, 전류인가 30초는 매우 불안정한 결과가 나타났다. 반면, 전류량 증가와 행정거리(TS) 증가 관계는 전류인가 15초일 때가 전류인가 30초일 때보다 더 안정적인 결과가 나타났다.

게 가공폐기물을 이용한 식품보존료의 개발에 관한 연구 (A Development of Food Preservative with the Waste of Crab Processing)

  • 장동석;조학내;구효영;최위경
    • 한국수산과학회지
    • /
    • 제22권2호
    • /
    • pp.70-78
    • /
    • 1989
  • 게 껍질 속에 함유된 chitin으로 부터 높은 항균력을 나타내는 chitosan의 제조 방법과 특성을 구명하였으며, 이 chitosan을 이용하여 식품의 변질에 관련된 미생물을 중심으로 항균력을 조사하여 천연 식품 보존료로 이용 가능성을 검토하였다. 1. 상법에 따라 조제한 분자량 2,800,000의 고분자 chitosan은 2,000ppm의 농도로 대장균의 증식을 억제시킬 수 있는 등, 항균력을 보유하고 있기는 하였으나 미약하였다. 2. Deacetylation 처리 시 $50\%$ 수산화나트륨 용액에서 8시간 boiling시켜 얻은 분자량 35,000의 저분자 chitosan은 75ppm으로 대장균의 중식을 억제시킬 수 있어서 고분자 chitosan에 비해 20배 가량 항균력이 증대되었다. 3. 세균에 대한 chitosan의 항균력에 있어서 Bacillus sp. 나 구균류 등의 Gram 양성균은 50ppm 첨가로 균의 증식이 억제되었으나, Gram 음성균에 대해서는 균종에 따라 차이가 커 Pseudomonas sp. 와 Vibrio sp. 는 100ppm으로, Salmonella는 2,000ppm으로 증식을 억제시킬 수 있었다. 4. 진균류에 있어서 Saccharomyces sp.는 100ppm으로 억제되었으나, Hansenula sp.는 5,000ppm에서도 증식이 일어나 효모류는 균종간에 차이가 켰으며, 곰팡이류에 대해서는 별 효과가 없는 것으로 나타났다. 5. 숙성시킨 물김치에 chitosan을 첨가하여 저장수명을 연장시킬 수 있었는데, chitosan $0.2\%$ 첨가후 $5^{\circ}C$에 저장함으로서 무첨가구에 비해 10일 가량 품질을 안정하게 유지시킬 수 있었다. 따라서 이 chitosan은 천연 식품 보존료로 이용 가능하다고 하겠다.

  • PDF

식물성 절연유의 가속열화에 따른 주요 성분 및 물성 변화 (Changes of Properties and Gas Components according to Accelerated Aging Test of Vegetable Transformer Oil)

  • 이돈민;이미은;박천규;하종한;박현주;전태현;이봉희
    • 에너지공학
    • /
    • 제25권3호
    • /
    • pp.18-26
    • /
    • 2016
  • 대부분의 변압기에 사용되고 있는 절연유는 석유계 원료를 이용한 광유계 절연유였으나 유출시 환경오염, 낮은 인화점으로 인한 화재 위험성을 가지고 있어 보다 친환경 식물성 원료를 활용한 절연유 도입이 최근 검토되고 있다. 그러나 식물성 절연유의 높은 생분해성과 인화점으로 절연유로서의 높은 적용가능성에도 불구하고 장기운전에 의한 열화가 미치는 영향에서는 아직 많은 연구가 필요한 실정이다. 따라서 본 연구에서는 변압기의 구성요소를 감안하고 실제 운전조건보다 높은 $150^{\circ}C$에서 2주간의 가속열화 시험을 통해 전산가, 수분, 절연파괴전압 등의 주요물성 변화를 통해 식물성 절연유 산화특성과 이 과정에서 생성되는 용존 가스 분석을 실시였다. 이를 통해 식물성 절연유가 기존 광유계 절연유 대비 친수성에 의한 전산가 상승에도 불구하고 절연성능을 유지하는 특징을 가지고 있으며 가스 성분 비교를 통해 주어진 온도 조건에서 우수한 열안정성을 나타내고 있음을 확인하였다.

도홍사물탕(桃紅四物湯)이 광화학적 뇌경색 마우스의 유전자 발현에 미치는 영향 (Effects of Dohongsamul-Tang on the Gene Expression of Photothrombotic Ischemia Mouse Model)

  • 조권일;김혜윤;고석재;이성근;신선호;문병순
    • 동의생리병리학회지
    • /
    • 제23권3호
    • /
    • pp.645-661
    • /
    • 2009
  • The water extract of Dohongsamul-Tang(DHSMT) has been traditionally used to stroke and brain injuries in Oriental Medicine. The present study was designed to investigate the effects of DHSMT on the gene expression profile of cerebral infarction by cDNA microarray in photothrombotic ischemia mouse model. Photothrombotic ischemia was induced in stereotactically held male BALB/c mice using rose bengal and cold light. MRI was performed 24 hours after inducing photothrombosis using 1.5 T MRI and 47 mm surface coil to obtain T2-weighted, and contrast-enhanced images. After MRI test, animal was sacrificed and the brain sections were stained for hematoxylin and eosin and immunohistochemistry. MRI and histological analysis revealed that lesion of thrombotic ischemia was well induced in the cortex with the evidence of biological courses of infarction. The target area of thrombotic infarction was 1 mm anterior to bregma and 3 mm lateral to midline with 2 mm in diameter, which were decreased by administration of DHSMT. To assess gene expression pattern of cerebral infarction, mRNA was isolated and reacted with microarray chip(Agilant's DNA Microarray 44K). Scatter and MA plot analysis were performed to clustering of each functional genes. M value [M=log2(R/G), A={log2(R ${\times}$ G)}/2] was between -0.5 and +0.5 with 40% difference. After pretreatment with DHSMT, the expression levels of mRNA of many genes involved in various signaling pathway such as apoptosis, cell cycle, cell proliferation, response to oxidative stress, immune response, angiogenesis, and inflammatory cytokine were markedly inhibited in photothrombotic ischemia lesion compared to the control group. These results suggest that DHSMT prevent ischemic death of brain on photothrombotic ischemia model of mice through modulation of gene expression at the transcriptional level.

전자기 수치 해석을 이용한 Combo 표준 보정 시험편의 MRPC Probe 와전류 신호 모사 및 평가 (Simulation and Evaluation of ECT Signals From MRPC Probe in Combo Calibration Standard Tube Using Electromagnetic Numerical Analysis)

  • 유주영;송성진;정희준;공영배
    • 비파괴검사학회지
    • /
    • 제26권2호
    • /
    • pp.90-98
    • /
    • 2006
  • 원전 증기 발생기 세관의 MRPC probe 신호를 검사하고 평가하기 위해서는 일반적으로 Combo 표준 보정 시험편 신호가 신호 보정을 위해 사용된다 이렇듯 Combo 표준 보정 시험편 신호는 신호 평가에 중요한 영향을 미치지만, probe 상태나 관 주위의 여러 요소에 의해 쉽게 영향을 받기 때문에 결함 평가 요소인 신호의 크기 값과 위상각을 왜곡시킬 수 있다. 따라서 본 연구는 이런 문제점을 극복하기 위해 Combo 표준 보정 시험편의 실제 신호를 모사 신호로 대체하는 가능성을 알아보기 위해 실험을 해 보았다 이를 위해 MRPC probe와 Combo 표준 보정 시험편의 특성을 조사하였으며 계산 수행을 위해 체적 적분 방법으로 계산되는 상용 전자기 해석 프로그램인 VIC-3D를 사용하였고 모사 신호를 생성한 후 실험 신호와 비교를 통해 신호의 정확성을 확인하였다. 마지막으로, 모사 신호를 이용한 결함 평가를 위하여 실제 결함과 가공 결함에 대해 위상각과 크기 값의 항목으로 평가하여 실제 결함 평가자에 의한 결과와 비교하였다.

변환시설 발생 해체금속폐기물의 용용제염처리

  • 황두성;김동호;이규일;최윤동;박진호;정운수
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2009년도 학술논문요약집
    • /
    • pp.63-64
    • /
    • 2009
  • 변환시설의 해체 시 발생한 해체폐기물은 2009년 현재까지 약 354톤이며, 이들 중 탱크, 배관, 반응기, 펌프류 동의 해체금속폐기물이 약 191톤으로 54% 를 차지하고 있다. 이들 해체금속폐기물은 제염 처리공정을 통하여 전량 자체처분폐기물로 전환시키는 것을 목표로 두고 있다. 이는 오염된 금속류를 효과적으로 제염한 다음 자체처분시킴으로서 방사성폐기물에 대한 처분비용을 저감할 수 있기 때문이다. 해체금속폐기물 중 스테인레스강 해체폐기물은 질산 용액을 사용한 초음파화학제염공정으로 제염한 후 자체처분폐기물로 53톤을 전환하였다. 탄소강 해체물의 경우 스팀제염공정으로 제염한 결과 제영 효율은 좋았으나 변환시설 가동 중 유지 보수를 위하여 페인팅을 하였던 해체물의 경우 페인트를 제거하지 않을 경우 스팀제염장치로는 제염이 안 되었다. 탄소강 해체금속폐기물은 약 117톤 발생하였으며, 이들 중 모터, 펌프 등을 제외한 제염 대상 폐기물은 약 80톤이며, 이들을 용융 제염 및 감용을 위하여 기초 연구를 수행한 결과를 바탕으로 약 180kg/batch 용량의 금속용융제염 설비를 제작 설치하여 탄소강 해체금속폐기물 용융제염 처리를 수행 중에 있다. 금속용융은 장치가 간단하고 폐기물 처리량이 비교적 적고 단속적인 운전에 매우 효과적인 고주파 유도로를 사용하였다. 용융장치는 고주파 발진장지와 용해로체로 구성된 고주파 유도설비와 냉각계통으로 구성된다. 고주파발진장치는 철제 200kg을 용해할 수 있는 용량을 갖추었으며, 실험 및 실제 처리 등 용해로체의 크기 변경이 필요할 경우에는 고주파발진기의 출력 주파수를 변경할 수 있게 하였다. 용융 장치의 발진기 부분의 입력전원은 3상, 440V, 60Hz 이며, 출력전원은 200kW, 출력주파수는 lkHz, 3kHz, 5kHz로 구성되어 있으며, 회당 180kg 의 폐기물을 용융할 시에는 3kHz로 고정하여 사용하였다. 용해로체 부분 중 고주파유도가열부는 heating coil 및 절연부로 구성되어 있고, 그 외 support frame과 lever로 구성되어 있다. 용해로체와 고주파 발진장치의 냉각을 위한 냉각설비는 냉각기와 냉매의 저장을 위한 저장조로 구성되어 있으며, 냉각기의 용량은 20RT 이다. 용융로체의 직경은 약 28cm로 크기가 큰 해체물의 장입이 어려워 작은 크기로 세절을 해야만 하며,용융로의 용량을 증가시킬 경우 해체물을 작은 크기로 세절하는 비용을 절감할 수 있을 것이다. 용융 중 시료 채취는 매 배치마다 수행하였으며, 그림3과 같은 시료 채취용 주형 틀에 국자모양의 채취기로 채취하였다. 해체물의 용융시 ingot를 생성하기 위해서 주형틀에 용융물을 장입하기 전 시료를 채취하였다 그림4는 생성된 ingot이며, 이들의 방사능 농도는 배치마다 차이는 있지만 최대 0.05 Bq/g 이하로 나타나 자체처분 폐기물로 전량 전환 가능하였다 그림5 는 해체물에 함유된 우라늄과 불순물을 제거한 슬래그로 방사능농도는 약 12Bq/g 으로 나타났으며, 이들의 발생량은 약 3wt% 정도로 폐기물 발생량이 작았다. 따라서 금속폐기물의 경우 용융제염으로 처리할 경우 폐기물 발생량을 최대로 줄일 수 있어 처리 효율이 기타 처리 공정보다 효율적인 것으로 판단된다.

  • PDF

자기공명검사에서 통증제어가 불가능한 급성 요통 환자의 옆으로 누운 자세에 대한 영상평가 (Evaluated the L-spine Magnetic Resonance Imaging for the Scanning Method of the Lateral Recumbent Position with to the Embarrassed Control of the Acute Low Back Pain)

  • 이재흔;이재승;임인철
    • 한국방사선학회논문지
    • /
    • 제8권5호
    • /
    • pp.255-260
    • /
    • 2014
  • 본 연구에서는 통증제어가 거의 불가능한 급성요통 환자를 대상으로 바로 누운 자세를 할 수 없는 환자에게 불가피하게 자기공명검사를 받아야할 환자를 위해 기존촬영방법인 정상 체위 바로 누운 자세 대신 변형된 옆으로 누운 자세를 취하게 하여 기존 척추 전용 코일과 복부 전용 코일을 이용하여 요통을 경감시키고 불안정한 자세 보정과 움직임에 의한 인공물을 줄여 장시간 검사를 받는 환자에게 피로감을 감소시켜 자기공명검사의 성공률을 높이고자 한다. 평가방법으로는 영상의 질을 정성적 평가로 하였으며 결과로는 정상인 연구대상자 기존촬영방법인 바로 누운 자세의 평균 점수는 4.64점, 정상인 연구대상자 옆으로 누운 자세(A군)는 3.44점, 극심한 요통을 호소하는 비정상인 연구대상자 옆으로 누운 자세(B군)는 3.40점으로 나타났다. 결론적으로 정상인 연구대상자의 기존촬영방법인 바로 누운 자세에서 검사한 정성적인 평가는 예상대로 높게 나타났으나 정상인 연구대상자 옆으로 누운 자세와 극심한 요통을 호소하는 비정상인 연구대상자 옆으로 누운 자세로 검사한 영상의 정성적 평가는 거의 비슷하게 나타났다. 또한 극심한 요통을 호소하는 비정상인 연구대상자 옆으로 누운 자세(B군)의 영상평가에서 영상의학과 전문의의 영상판독에도 문제가 없는 것으로 나타났다. 이에 바로 누운 자세에서 검사를 진행함에 불편을 겪는 환자에게 이러한 기법이 보편화 된다면 임상에서 많이 활용될 것으로 사료된다.

펄스 와전류를 이용한 알루미늄 두께 평가 (Thickness Evaluation of the Aluminum Using Pulsed Eddy Current)

  • 이정기;서동만;이승석
    • 비파괴검사학회지
    • /
    • 제25권1호
    • /
    • pp.15-19
    • /
    • 2005
  • 일반적인 와전류 검사는 단일 주파수 또는 매우 협소한 주파수 대역을 가지는 정현적 신호 사용하며, 알루미늄과 같은 도체에서 피로 균열 같은 결함을 검출하는데 사용되고 있다. 이에 반하여 펄스 와전류는 아주 넓은 주파수 대역폭을 가지는 펄스 신호를 사용한다. 이것은 여러 주파수를 동시에 사용하는 다중 주파수 와전류 검사를 한번에 수행할 수 있도록 하며, 일상적인 와전류 검사에 비하여 침투 깊이를 더 깊게 할 수 있다는 장점이 있다. 본 연구에서는 부식 또는 침식 등에 의한 금속 손실을 평가하기 위한 펄스 와전류 장치를 개발하였다. 개발된 장비는 최대 40 V의 구형 펄스를 발생시키는 펄스 발생기, 수신된 신호를 52 dB까지 증폭하는 증폭기, 16 bit 20MHz의 A/D 변환기, 윈도우 프로그램으로 운영되는 산업용 개인 컴퓨터로 구성하였다. 펄스 와전류 탐촉자는 구동 코일 안에 검출 코일을 삽입한 pancake 형태로 설계 제작하였다. 검출 코일의 출력 신호는 구동 코일에 전압을 끊을 때 갑자기 증가하고 신호의 후반부는 시간에 따라 지수적으로 감소하였으며, 감쇠율을 나타내는 지수 값은 알루미늄 두께가 두꺼울수록 증가하였다.