• Title/Summary/Keyword: coefficient region

Search Result 1,348, Processing Time 0.022 seconds

Effect of applied magnetic fields on Czochralski single crystal growth (Part II) (Czochralski 단결성 성장특성제어를 위한 자장형태에 관한 연구 (Part 2))

  • Chang Nyung Kim
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.4 no.1
    • /
    • pp.46-56
    • /
    • 1994
  • The characteristics of flows, temperatures, concentrations of the boron are numerically studied when uniform axial magnetic fields are applied in the Czechralski crucible. The to governing factors to the flow regimes are buoyancy, thermocapillarity, centrifugal forces, magnetic forces, diffusion coefficient and segregation coefficient of the boron. Since the concentration of the boron is so low that buoyancy effects are negligible, it cannot affect the flow and temperature fields. From the fact that the flow fields are rotationally symmetric, two velocity components in the meridional plane and the circumferential velocity are calculated together with the temperature in the steady state. Based on the known velocity and temperature distributions the unsteady concentration distributions of the boron are calculated. As the strength of the magnetic is increased, the flow velocities are decreased. Circumferential velocities are large near the crucible side-wall and in the region below the rotating crystal. Steep temperatures gradient near the edge of the rotating crystal causes the Marangoni convection. It has been found out that the convection characteristics affects the unsteady transport phenomena of the boron.

  • PDF

An Experimental Study on Heat Transfer and Pressure Drop Characteristics of Carbon Dioxide During Gas Cooling Process in a Hellically Coiled Tube

  • Oh, Hoo-Kyu;Son, Chang-Hyo;Yu, Tae-Geun;Kim, Dae-Hui
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.263-271
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during 9as cooling process of $CO_2$ (R744) in a helically coiled copper tube with the inner diameter of 4.55 mm and outer diameter of 6.35 mm were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter a pre-heater and a helically coiled type gas cooler (test section). The refrigerant mass fluxes are varied from 200 to $800kg/m^2s$ and the inlet pressures of gas cooler are 7.5 to 10.0 MPa. The heat transfer coefficients of $CO_2$ in a helically coiled tube are higher than those in a horizontal tube. The Pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with those predicted by Ito's correlation developed for single-phase in a helically coiled tube. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Pitla et al. However. at the region near pseudo-critical temperature. the experiments indicate higher values than the Pitla et al correlation. Therefore, various experiments in helically coiled tubes have to be conducted and it is necessary to develop the reliable and accurate prediction determining the heat transfer and pressure drop of $CO_2$ in a helically coiled tube.

Fabrication of 1-3 Piezo-composites with a "Dice & Fill" Method and Characterization of Their Piezoelectric Properties as a Function of Lateral Spatial Scale ("Dice와 fill" 방식을 이용한 1-3 압전복합재의 제조와 횡방향 단위 크기에 따른 압전특성 평가)

  • Kim, Young-Deog;Kim, Kwang-Il;Jeong, Woo-Cheol;Kim, Heung-Rak;Kim, Dong-Su
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.354-360
    • /
    • 2002
  • The piezoelectric composites had many advantages in comparison with conventional piezoelectric ceramics and piezopolymers for ultrasonic transducers used in NDT and in medical ultrasionic imaging. The electromechanical coupling coefficient should be high and the acoustic impedance should be low in these applications. However, the cross-coupling with spurious oscillations caused by laterally running plate waves exhibited complex motions in the surface of piezoelectric composites with coarse lateral spatial scale. The thickness mode electromechanical coupling coefficient of 1-3type of piezoelectric compoistes were 0.36 to 0.64, and the acoustic impedance of them were 9.8 to 22.7 MRayl. The lateral resonance frequency of 1-3 type piezoelectric composites shifted to high frequency region with decreasing lateral spatial scale.

Somatic cell counts determination in cow milk by near infrared spectroscopy: A new diagnostic tool

  • Tsenkova, R.;Atanassova, S.;Kawano, S.;Toyoda, K.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.4104-4104
    • /
    • 2001
  • Milk somatic cell count (SCC) is a recognized indicator of cow health and milk quality. The potential of near infrared (NIR) spectroscopy in the region from 1100 to 2500nm to measure SCC content of cow milk was investigated. A total of 196 milk samples from 7 Holstein cows were collected for 28 days, consecutively, and analyzed for fat, protein, lactose and SCC. Three of the cows were healthy, and the rest had mastitis periods during the experiment. NIR transflectance milk spectra were obtained by the InfraAlyzer 500 spectrophotometer in a wavelength range from 1100 to 2500 nm. The calibration for logSCC was performed using partial least square (PLS) regression and different spectral data pretreatment. The best accuracy of determination was found for equation, obtained using smoothed absorbance data and 10 PLS factors. The standard error of calibration was 0.361, calibration coefficient of multiple correlation 0.868, standard error of prediction for independent validation set of samples 0.382, correlation coefficient 0.854 and the variation coefficient 7.63%. The accuracy of logSCC determination by NIR spectroscopy would allow health screening of cows, and differentiation between healthy and mastitic milk samples. When the spectral information was studied it has been found that SCC determination by NIR milk spectra was indirect and based on the related changes in milk composition. In the case of mastitis, when the disease occurred, the most significant factors that simultaneously influenced milk spectra were alteration of milk proteins and changes in ionic concentration of milk.

  • PDF

Analysis on the Wave Characteristics of Submerged Breakwater Considering Energy Dissipation of Seabed (해저면의 에너지 감쇠를 고려한 불투과 잠제의 파랑특성해석)

  • Kim Nam-Hyeong;Yang Soon-Bo;Park Min-Su;Kim Sang-Jin
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.7 no.3
    • /
    • pp.131-136
    • /
    • 2004
  • The transmission coefficients of impermeable submerged breakwater on permeable bottom are computed numerically using a boundary element method. The analysis method is based on the wave pressure function with the continuity in the analytical region including fluid and structures. Wave motion over permeable bottom is simulated by introducing a linear dissipation coefficient and an added mass coefficient. The results indicate that the wave over permeable bottom travels being damped, and that transmission coefficients for permeable bottom are smaller than those for impermeable bottom, and result from the change of width and height of submerged breakwater.

  • PDF

Face Detection Algorithm Using Pulse-Coupled Neural Network in Color Images (컬러영상에서 Pulse-Coupled Neural Network를 이용한 얼굴 추출 알고리즘)

  • Lim, Young-Wan;Na, Jin-Hee;Choi, Jin-Young
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.14 no.5
    • /
    • pp.617-622
    • /
    • 2004
  • In this work, we suggested the method which improves the efficiency of the face detection algorithm using Pulse-Coupled Neural Network. Face detection algorithm which uses the color information is independent on pose, size and obstruction of a face. But the use of color information encounters some problems arising from skin-tone color in the background, intensity variation within faces, and presence of random noise, and so on. Depending on these conditions, we obtained the mean and variance of the skin-tone colors by experiments. Then we introduce a preprocess that the pixel with a mean value of skin-tone colors has highest level value (255) and the other pixels in the skin-tone region have values between 0 and 255 according to a normal distribution with a variance. This preprocess leads to an easy decision of the linking coefficient of Pulse-Coupled Neural Network.

Cooling Heat Transfer Characteristics of CO2 in Helical Coil Type Gas Coolers (헬리컬 코일형 가스냉각기 내 CO2의 냉각 열전달 특성)

  • Son, Chang-Hyo;Jeon, Min-Ju;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.699-706
    • /
    • 2007
  • The cooling heat transfer coefficient and pressure drop of $CO_2$(R-744) in helical coil copper tubes were investigated experimentally The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter. a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45 and 4.55mm inner diameter The refrigerant mass fluxes were varied from 200 to $600 [kg/m^2s]$ and the inlet pressures of 9as cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows a relatively food agreement with those Predicted by Ito's correlation developed for single-phase in helical coil tubes. Though a few correlation available with the data. the local heat transfer coefficient of $CO_2$ agrees well with those presented by Pitla et al. among the predictions. However at the region near pseudo-critical temperature. the experiment data indicate higher values than the Pitla et al. correlation.

Heat Transfer Characteristics of Inclined Helical Coil Type Heat Exchanger (경사진 헬리컬 코일 열교환기의 열전달 특성에 관한 연구)

  • Son, Chang-Hyo;Jeon, Min-Ju;Jang, Seong-Il;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.707-714
    • /
    • 2007
  • The heat transfer coefficient and Pressure drop during gas cooling process of $CO_2$ (R-744) in inclined helical coil copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver. a variable-speed pump. a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45mm inner diameter. The refrigerant mass fluxes were varied from 200 to $600[kg/m^2s]$ and the inlet Pressures of gas cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in the inclined helical coil tubes increases with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with those Predicted by Ito's correlation developed for single-phase in a helical coil tube. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Pitla et al. However, at the region near pseudo-critical temperature. the experiments indicate higher values than the Pitla et al. correlation. Therefore. various experiments in the inclined helical coil tubes have to be conducted and it is necessary to develop the reliable and accurate prediction determining the heat transfer and pressure drop of $CO_2$ in the inclined helical coil tubes.

Organic Solvent Dyeing(III) -The Interpretation of Dyeing Behavior by Thermodynamic Parameters on Dyeing of Polyester Fiber in Alkanes as Dyeing Media- (유기용매염색(III) -Alkane류를 염색매체로 한 PET의 염색에 있어서 열역학적 파라미터에 의한 염착거동 해석-)

  • 김태경;임용진;조광호;조규민
    • Textile Coloration and Finishing
    • /
    • v.12 no.1
    • /
    • pp.52-60
    • /
    • 2000
  • In the prior studies, we reported that the dye uptakes of C. I. Disperse Violet 1 on polyester fiber in hexane and cyclohexane were higher than those in the other solvents, as the number of carbon atoms of alkanes decreased, the dye uptake increased, and the logarithmic plot of the dye uptakes vs. the solubilities of the dye showed that the dye uptakes are inversely proportional to the solubilities. In this study, for Interpretation of dyeing behavior of C. I. Disperse Violet 1 on polyester in alkanes, the thremodynamic parameters of dyeing, such as standard affnity, heat of dyeing(enthalpy change), entropy change, diffusion coefficient, and activation energy of diffusion, were obtained from isotherms and dyeing rates at different temperature. As the number of carbon atoms of alkanes increased, the standard affinity decreased, but the heat of dyeing(enthalpy change) and the entropy change showed larger negative values. These results mean that as the number of carbon atoms of alkanes increases, the dye uptake decreases, but both the fraction of the dye molecules dyed at relatively highly aligned or compact region of polyester fiber and the regularity of dye aggregates in the fiber become increased. As the number of carbon atoms of alkanes increased, the diffusion coefficient decreased, but the activation energy of diffusion increased. In the alkane of larger number of carbon atoms, because the solubility of the dye is higher, the desorption rate of the dye is faster and the diffusion coefficient is smaller than those in the smaller alkanes. But the energy required to separate the dye molecules from the alkane molecules is much higher because the interaction between the alkane molecule and the dye molecule become strong with the number of carbon atoms.

  • PDF

The Boundary Element Analysis of Waves coming with Oblique Angle to a Submerged Breakwater (잠제에 경사로 입사하는 파랑의 경계요소 해석)

  • Kim, Nam Hyeong;Woo, Su Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5B
    • /
    • pp.295-300
    • /
    • 2012
  • Reflection coefficients of wave due to the types of a submerged breakwater on the inclined incident wave are numerically computed by using boundary element method. The analysis method is based on the wave pressure function with the continuity in the analytical region including fluid and structures. When compared with the existing results on the inclined incident wave, the results of this study show good agreement. It is found that both maximum and minimum values of the reflection coefficient are appeared frequently, as the width of a submerged breakwater becomes wider, and the reflection coefficient increase, as the wave period is longer. In addition, the effect on the reflection coefficient due to the change of submerged breakwater hight is lager than that due to the change of submerged breakwater width. The results indicate that dissipating characteristics of wave due to the types of a submerged breakwater own high dependability regarding the change of inclined incident waves. Therefore, the results of this study is estimated to be applied as an accurate numerical analysis referring to inclined incident waves in real sea.