• 제목/요약/키워드: coefficient of performance

Search Result 4,619, Processing Time 0.04 seconds

Energy Performance Evaluation of Apartment Houses According to Window Energy Consumption Efficiency Rating System in Korea (창호 에너지소비효율등급제에 따른 공동주택의 열성능 평가)

  • Lim, Hee Won;Kim, Dong Yun;Lee, Soo Man;An, Jung Hyuk;Yoon, Jong Ho;Shin, U Cheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.4
    • /
    • pp.159-166
    • /
    • 2018
  • The Korean fenestration energy consumption efficiency rating system only considers thermal performance of the heat transfer coefficient (U-value) and airtightness excluding optical characteristics of the solar heat gain coefficient (SHGC). This study analyzed annual heating and cooling energy requirements on the middle floor of apartment by optical and thermal performance of windows to evaluate the suitability of the rating system. One hundred and twenty-eight windows were analyzed using THERM and WINDOW 7.4, and energy simulation for a reference model of an apartment house facing south was performed using TRNSYS 17. The results showed that window performance was the main factor in the heating and cooling load. The heating load of the reference model was 539 kWh to 2,022 kW, and the cooling load was 376 kWh to 1,443 kWh. The coefficient of determination ($R^2$) of the heating and cooling loads driven from the SHGC were 0.7437 and 0.9869, which are more compatible than those from the U-value, 0.0558 and 0.4781. Therefore, it is not reasonable to evaluate the energy performance of windows using only the U-value, and the Korean fenestration energy consumption efficiency rating system requires a new evaluation standard, including SHGC.

An Analysis of Factors Influencing Insulation Performance of Inorganic Autoclaved Lightweight Concrete Sandwich Wall Panels Using Shear Connectors (전단연결재를 적용한 무기계 경량기포콘크리트(ALC) 샌드위치 외벽 패널의 단열성능에 미치는 영향요인 분석)

  • Kang, Dong Howa;Kang, Dong Hwa;Shin, Dong Hyeon;Kim, Hyung Joon
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.79-87
    • /
    • 2018
  • The purpose of this study was to analyze factors influencing insulation performance of inorganic Autoclaved Lightweight Concrete(ALC) sandwich wall panels with the application of shear connectors. To analyze the effect of shear connectors on the thermal performance of sandwich wall panels, heat transfer analysis was conducted by using the three-dimensional heat transfer simulation software. Four types of shear connector such as Pin, Clip, Grid, and Truss were selected for insulation performance analysis. Thermal bridge coefficient was calculated by varying typical panel thickness and shear connector thickness and materials such as steel, aluminum, and stainless steel. The results showed that Grid and Truss type widely distributed along the section of sandwich wall panel had a great influence on the thermal bridge coefficient by changing the influence factors. Based on the results of thermal and structural performance analysis, effective heat transmission coefficient of the sandwich wall panel satisfying the passive house insulation criteria was calculated. As a result, it was found that heat transmission coefficient was increased from $0.132W/m^2{\cdot}K$ to $0.141{\sim}0.306W/m^2{\cdot}K$ depending on the shear connector types and materials. In the majority of cases, the passive house insulation criteria was not satisfied after using shear connectors. The results of this study were likely to vary according to how influence factors were set, but it is important to apply the methods that reduce the thermal bridge when there would be a possibility of greatly affecting the insulation performance.

Performance Evaluation of Ground Source Heat Pump System Utilizing Energy Pile in Apartment (공동주택에서 에너지 파일을 이용한 지열히트펌프 시스템의 성능 분석)

  • Lee, Jin-Uk;Kim, Taeyeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.41-46
    • /
    • 2012
  • In Korea, Apartment houses recently occupy over 80% of all buildings. Ground source system has to be designed to consider feature of apartment house. Most apartment houses use PHC pile to get a bearing power of the soil. Therefore, the purpose of this study is to evaluate performance of ground source heat pump system utilizing energy pile under apartment. Object of experiment is low-energy experiment apartment in Song-do and Energy Pile are applied to 80%, 100% energy reduction model for heat-source. First, performance evaluation of Energy Pile geothermal system was done during summer season. As a result, The COP(coefficient of performance) about geothermal heatpump was approximately 5-6 while cooling. In winter season, Long experiment was performed because it was very important to evaluate ground condition for long time. During heating experiment, Indoor room set temperature was $20^{\circ}C$ and kept constant by heating. Coefficient of performance for heat pump and overall system was calculated. It was 3.5-4.5 for COP and 2.5-3.7 for system COP.

Numerical Study of Channel Area Effects on the Performance Characteristics of Regenerative Type Fuel Pump (재생형 연료펌프의 채널 면적 변화가 성능 특성에 미치는 영향에 대한 수치해석적 연구)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Son, Kwang-Eun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.5
    • /
    • pp.41-45
    • /
    • 2007
  • The effects of channel area on the performance of regenerative type fuel pump were numerically studied by commercial CFD code (ANSYS CFX-10). To examine the effects of channel area, the shapes of the side channel and blade were simplified. The channel area affected the flow characteristics of the internal recirculation flow between the side channel and the blade groove and also made a difference in the overall performance. These loss mechanism with circulation flow were adopted as a loss coefficient in the performance prediction program. The loss coefficient was newly derived from the results of calculations with different channel area, and compared with the experimental results in the reference paper and used to modify the performance prediction program. The circulation flow characteristics with different channel area, which is related with loss mechanism, were also discussed with the results of 3-dimensional flow calculations.

The Effects of Intellectual Capital on Financial Performance of Korean Banks (지식자본이 은행의 재무성과에 미치는 영향)

  • Kim, Sung Woo;Lee, Ki Hwan
    • International Area Studies Review
    • /
    • v.22 no.4
    • /
    • pp.37-54
    • /
    • 2018
  • This study examines empirically on relevance between bank performance and IC(Intellectual Capital) in the field of banking sector in Korea. IC is measured by VAIC(Value Added Intellectual Capital) and VAIC consists of HCE(Human Capital Efficiency Coefficient), CEE(Capital Employed Efficiency Coefficient) and SCE(Structural Capital Efficiency Coefficient). Main results are as follows. First, the effects of IC(Intellectual capital) on banks performance show significant (+) effect on the performance of banks. Second, Human capital and bank size shows the significant effect on the banks financial performance but SCE, CEE, and other variables didn't show it. As a concluding remark, IC(Intellectual capital) is very helpful for banks to go forward financially to get information and knowledges easily. This study help stakeholders and investors assess the value creating potential of banks and policy makers to implement policies for performance establishment of a Korean banking sector.

A Study on the Flow Characteristics and Engine Performance with Swirl Ratio Variance of Intake Port (흡기포트 선회비 변경에 따른 유동특성 및 엔진성능에 관한 연구)

  • Yoon, Jun-Kyu;Cha, Kyung-Ok
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.899-905
    • /
    • 2000
  • The characteristics of air flow and engine performance with swirl ratio variance of intake port In a turbocharged DI diesel engine was studied in this paper. The intake port flow is important factor which have influence on the engine performance and exhaust emission because the properties in the injected fuel depend on the combustion characteristics. The swirl ratio for ports was modified by hand-working and measured by impulse swirl meter. For the effects on performance and emission, the brake torque and brake specific fuel consumption were measured by engine dynamometer and NOx, smoke were measured by gas analyzer and smoke meter. As a result of steady flow test, when the valve eccentricity ratio are closed to cylinder wall, the flow coefficient and swirl intensity are increased. And as the swirl ratio is increased, the mean flow coefficient is decreasing, whereas the gulf factor is increasing. Also, through engine test its can be expected to meet performance and emission by optimizing the main parameters; the swirl ratio of intake port, injection timing and compression ratio.

  • PDF

Noise Robust Text-Independent Speaker Identification for Ubiquitous Robot Companion (지능형 서비스 로봇을 위한 잡음에 강인한 문맥독립 화자식별 시스템)

  • Kim, Sung-Tak;Ji, Mi-Kyoung;Kim, Hoi-Rin;Kim, Hye-Jin;Yoon, Ho-Sub
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.190-194
    • /
    • 2008
  • This paper presents a speaker identification technique which is one of the basic techniques of the ubiquitous robot companion. Though the conventional mel-frequency cepstral coefficients guarantee high performance of speaker identification in clean condition, the performance is degraded dramatically in noise condition. To overcome this problem, we employed the relative autocorrelation sequence mel-frequency cepstral coefficient which is one of the noise robust features. However, there are two problems in relative autocorrelation sequence mel-frequency cepstral coefficient: 1) the limited information problem. 2) the residual noise problem. In this paper, to deal with these drawbacks, we propose a multi-streaming method for the limited information problem and a hybrid method for the residual noise problem. To evaluate proposed methods, noisy speech is used in which air conditioner noise, classic music, and vacuum noise are artificially added. Through experiments, proposed methods provide better performance of speaker identification than the conventional methods.

  • PDF

Off-Design Performance Prediction of Multi-Stage Axial-Compressor by Stage-Stacking Method (단 축적법을 이용한 다단 축류 압축기 탈설계 성능예측)

  • Park, Tae-Jin;Baek, Je-Hyun;Yoon, Sung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.789-794
    • /
    • 2001
  • In this study, a program for the off-design performance prediction of multi-stage axial-compressors is developed based on stage-stacking method. To account for the increased losses at off-design conditions, generalized performance curve is applied. The purpose of this study is to investigate the influence of the choice of generalized performance curve and stator exit angle. For this purpose, we tested various generalized performance curves and stator exit angles. In conclusion, Muir's pressure coefficient curve gives a good prediction results regardless of the efficiency curve for a low-stage compressors. On the other hand, for high-stage compressors, The combination of Muir's pressure coefficient curve and Stone's efficiency curve gives a optimistic results. Stator exit angle has a small effect on overall performance curve.

  • PDF

Performance Prediction Comparison of Multi-Stage Axial-Compressor by Stage-Stacking Method (단 축적법을 이용한 다단 축류 압축기 성능예측 비교)

  • Park, Tae Jin;Yoon, Sungho;Baek, Je Hyun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.143-148
    • /
    • 2001
  • In this study, to investigate the effect of the generalized performance curve on the performance prediction and to find the optimal ones, a systematic study is performed. For this purpose, we compared the influence of the stage performance curves with experimental data in multi-stage axial compressors. As a result, it is discovered that the optimal generalized performance curves vary according to the number of the stages in compressors. And we found that for a low-stage compressors, Muir's pressure coefficient curve gives the best prediction results at design rotational frequency regardless of the efficiency curve. On the other hand, for high-stage compressors, Stone's pressure coefficient curve gives the optimistic results about the performance prediction at design rotational frequency.

  • PDF

Effect of Expansion Ratio on Contact Heat Transfer Coefficient in Fin-Tube Heat Exchanger (핀관 열교환기에서 확관율이 접촉열전달계수에 미치는 영향)

  • Lee, Sang-Mu;Park, Byung-Duck
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.1
    • /
    • pp.45-50
    • /
    • 2012
  • The plate fin and tube type of heat exchanger is widely used in air conditioner, and the heat exchanger is assembled by the mechanical expansion of copper tubes and fastening the aluminum fin. The objective of the present study is to investigate how the mechanical expansion of copper tube affects on the heat transfer performance of a plate fin and tube type heat exchanger. This study has been performed by experimental and numerical methods. The numerical and experimental results show that the tube expansion ratio has a influence on the heat transfer performance. Within the tested expansion ratio, the contact pressure shows the peak value and it decreases as the expansion ratio increases. Air-side heat transfer coefficient increases until the expansion ratio reaches 1.23, and then decreases with the similar pattern to the contact pressure. Also, contact heat transfer coefficient shows the maximum when the contact pressure is highest as well as the air-side heat transfer coefficient.