• 제목/요약/키워드: codes-of-practice

검색결과 185건 처리시간 0.023초

A systematic comparison of the wind profile codifications in the Western Pacific Region

  • Jiayao Wang;Tim K.T. Tse;Sunwei Li;Tsz Kin Chan;Jimmy C.H. Fung
    • Wind and Structures
    • /
    • 제37권2호
    • /
    • pp.105-115
    • /
    • 2023
  • Structural design includes calculation of the wind speed as one of the major steps in the design process for wind loading. Accurate determination of design wind speed is vital in achieving safety that is consistent with the economy of construction. It is noticeable that many countries and regions such as Hong Kong, Japan and Australia regularly make amendments to improve the accuracy of wind load estimations for their wind codes and standards. This study compares the latest Hong Kong wind code published in 2019, which is generally known as the Code of Practice on Wind Effects in Hong Kong - 2019, with the latest revision of the AIJ Recommendations for Loads on Buildings - 2015 (Japan), and the Australian/New Zealand Standard, AS/NZS 1170.2:2021. The comparisons include the variations between the design wind speed and the vertical profiles of wind speed multipliers. The primary purpose of this study was to show any differences in the basic design wind speed and exposure factor estimations among the three economies located in the Western Pacific Ocean. Subsequently, the reasons for such underlying variations between the three documents, are discussed, together with future development trends.

Pushover analysis of prefabricated structures with various partially fixity rates

  • Akkose, Mehmet;Sunca, Fezayil;Turkay, Alperen
    • Earthquakes and Structures
    • /
    • 제14권1호
    • /
    • pp.21-32
    • /
    • 2018
  • Prefabricated structures are constructed by bolted connections of separated members. The design and analysis of these structures are generally performed by defining fully hinges for the connection of separated members at the joint of junction. In practice, these connections are not fully hinged. Therefore, the assumption of semi-rigid connections (restrained or partially fixity) instead of fully hinge connections is a more realistic approach for bolted connections used in the prefabricated elements. The aim of this study is to investigate the effects of semi-rigid connections on seismic performance of prefabricated structures. Nonlinear static analysis (pushover analysis) of a selected RC prefabricated structure is performed with SAP2000 structural analysis program by considering various partially fixity percentages for bolted connections. The target values of roof displacements obtained from the analyses according to ATC-40, FEMA-356, FEMA-440, and TEC-2007 codes are compared each other. The numerical results are given in tables and figures comparatively and discussed. The results show that the effects of semi-rigid connections should be considered in design and analysis of the prefabricated structures.

Splitting of reinforced concrete panels under concentrated loads

  • Foster, Stephen J.;Rogowsky, David M.
    • Structural Engineering and Mechanics
    • /
    • 제5권6호
    • /
    • pp.803-815
    • /
    • 1997
  • It is well understood that concentrated forces applied in the plane of a beam or panel (such as a wall or slab) lead to splitting forces developing within a disturbed region forming beyond the bearing zone. In a linearly elastic material the length of the disturbed region is approximately equal to the depth of the member. In concrete structures, however, the length of the disturbed region is a function of the orthotropic properties of the concrete-steel composite. In the detailing of steel reinforcement within the disturbed regions two limit states must be satisfied; strength and serviceability (in this case the serviceability requirement being acceptable crack widths). If the design requires large redistribution of stresses, the member may perform poorly at service and/or overload. In this paper the results of a plane stress finite element investigation of concentrated loads on reinforced concrete panels are presented. Two cases are examined (i) panels loaded concentrically, and (ii) panels loaded eccentrically. The numerical investigation suggests that the bursting force distribution is substantially different from that calculated using elastic design methods currently used in some codes of practice. The optimum solution for a uniformly reinforced bursting region was found to be with the reinforcement distributed from approximately 0.2 times the effective depth of the member ($0.2D_e$) to between $1.2D_e$ and $1.6D_e$. Strut and tie models based on the finite element analyses are proposed herein.

Behaviour of large fabricated stainless steel beam-to-tubular column joints with extended endplates

  • Wang, Jia;Uy, Brian;Li, Dongxu
    • Steel and Composite Structures
    • /
    • 제32권1호
    • /
    • pp.141-156
    • /
    • 2019
  • This paper presents the flexural behaviour of stainless steel beam-to-tubular column joints with extended endplates subjected to static loading. Moment-rotation relationships were investigated numerically by using Abaqus software with geometric and material nonlinearity considered. The prediction of damages among components was achieved through ductile damage models, and the influence of initial geometric imperfections and residual stresses was evaluated in large fabricated stainless steel joints involving hollow columns and concrete-filled columns. Parametric analysis was subsequently conducted to assess critical factors that could affect the flexural performance significantly in terms of the initial stiffness and moment resistance. A comparison between codes of practice and numerical results was thereafter made, and design recommendations were proposed for further applications. Results suggest that the finite element model can predict the structural behaviour reasonably well with the component damage consistent with test outcomes. Initial geometric imperfections and residual stresses are shown to have little effect on the moment-rotation responses. A series of parameters that can influence the joint behaviour remarkably include the strain-hardening exponents, stainless steel strength, diameter of bolts, thickness of endplates, position of bolts, section of beams and columns. AS/NZS 2327 is more reliable to predict the joint performance regarding the initial stiffness and moment capacity compared to EN 1993-1-8.

Creep behaviour of normal- and high-strength self-compacting concrete

  • Aslani, Farhad
    • Structural Engineering and Mechanics
    • /
    • 제53권5호
    • /
    • pp.921-938
    • /
    • 2015
  • Realistic prediction of concrete creep is of crucial importance for durability and long-term serviceability of concrete structures. To date, research about the behaviour of self-compacting concrete (SCC) members, especially concerning the long-term performance, is rather limited. SCC is quite different from conventional concrete (CC) in mixture proportions and applied materials, particularly in the presence of aggregate which is limited. Hence, the realistic prediction of creep strains in SCC is an important requirement for the design process of this type of concrete structures. This study reviews the accuracy of the conventional concrete (CC) creep prediction models proposed by the international codes of practice, including: CEB-FIP (1990), ACI 209R (1997), Eurocode 2 (2001), JSCE (2002), AASHTO (2004), AASHTO (2007), AS 3600 (2009). Also, SCC creep prediction models proposed by Poppe and De Schutter (2005), Larson (2007) and Cordoba (2007) are reviewed. Further, new creep prediction model based on the comprehensive analysis on both of the available models i.e. the CC and the SCC is proposed. The predicted creep strains are compared with the actual measured creep strains in 55 mixtures of SCC and 16 mixtures of CC.

Static and fatigue performance of stud shear connector in steel fiber reinforced concrete

  • Xu, Chen;Su, Qingtian;Masuya, Hiroshi
    • Steel and Composite Structures
    • /
    • 제24권4호
    • /
    • pp.467-479
    • /
    • 2017
  • The stud is one of the most frequently used shear connectors which are important to the steel-concrete composite action. The static and fatigue behavior of stud in the steel fiber reinforced concrete (SFRC) were particularly concerned in this study through the push-out tests and analysis. It was for the purpose of investigating and explaining a tendency proposed by the current existing researches that the SFRC may ameliorate the shear connector's mechanical performance, and thus contributing to the corresponding design practice. There were 20 test specimens in the tests and 8 models in the analysis. According to the test and analysis results, the SFRC had an obvious effect of restraining the concrete damage and improving the stud static performance when the compressive strength of the host concrete was relatively low. As to the fatigue aspect, the steel fibers in concrete also tended to improve the stud fatigue life, and the favorable tensile performance of SFRC may be the main reason. But such effect was found to vary with the fatigue load range. Moreover, the static and fatigue test results were compared with several design codes. Particularly, the fatigue life estimation of Eurocode 4 appeared to be less conservative than that of AASHTO, and to have higher safety redundancy than that of JSCE hybrid structure guideline.

The Chinese Performance-based Code for Fire-resistance of Steel Structures

  • Li, Guo-Qiang;Zhang, Chao
    • 국제초고층학회논문집
    • /
    • 제2권2호
    • /
    • pp.123-130
    • /
    • 2013
  • In the past two decades, researchers from different countries have conducted series of experimental and theoretical studies to investigate the behaviour of structures in fire. Many new insights, data and calculation methods have been reported, which form the basis for modern interdisciplinary structural fire engineering. Some of those methods are now adopted in quantitative performance-based codes and have been migrated into practice. Mainly based on the achievements in structural fire research at China, the Chinese national code for fire safety of steel structures in buildings has been drafted and approved, and will be released in this year. The code is developed to prevent steel structures subjected to fire from collapsing, ensure safe evacuation of building occupants, and reduce the cost for repairing the damages of the structure caused by fire. This paper presents the main contents of the code, which includes the fire duration requirements of structural components, fundamental requirements on fire safety design of steel components, temperature increasing of atmosphere and structural components in fire, loading effect and capacity of various components in fire, and procedure for fire-resistant check and design of steel components. The analytical approaches employed in the code and their validation works are also presented.

Review on ICF-related Research Trends in Korean Clinical Field

  • Song, Ju-Min
    • 대한물리의학회지
    • /
    • 제16권4호
    • /
    • pp.33-44
    • /
    • 2021
  • PURPOSE: This study analyzed the research trends related to the International Classification of Functioning, Disability, and Health (ICF) to suggest an ICF utilization plan in the Korean clinical field. METHODS: In the RISS, KISS, NSDL, and PubMed databases, papers published between 2016 and July 2021 were collected by applying the search terms, 'ICF', 'international classification of functioning, disability and health', 'clinic', 'patient', and 'diagno'. The 44 papers selected were classified according to the analysis criteria, and the frequency and percentage were calculated. RESULTS: In domestic clinical trials, the frequency of ICF-related studies was in the order of physical therapy (n = 19) and occupational therapy (n = 14). The frequency of each study subject was observed in the order of studies related to a specific disease (n = 34) and prior studies (n = 7). The research topics were in the order of studies using ICF as a measurement tool (n = 21) and case studies with patients with specific diseases (n = 11). There were 18 studies using ICF codes and 14 papers applying the ICF domains. CONCLUSION: Over the last five years, ICF-related research in the domestic clinical field targeted patients with more diverse diseases in more expertise fields. Research for the unification of terms should be conducted for communication among various experts in clinical practice. To promote the use of ICF in the clinical field, it will be necessary to conduct research, such as the unification of terms, standardized education, development of ICF casebook, and development of ICF coding programs and guidelines.

직장 유암종 질병 분류 코드 변경과 임상적 의의 (Update of Korean Standard Classification of Diseases for Rectal Carcinoid and Its Clinical Implication)

  • 김은수
    • Journal of Digestive Cancer Reports
    • /
    • 제9권2호
    • /
    • pp.57-59
    • /
    • 2021
  • Carcinoid tumor is called as neuroendocrine tumor and is classified into neuroendocrine tumor Grade 1, neuroendocrine tumor Grade 2, and neuroendocrine carcinoma based on the differentiation of tumors. Recently, the incidence of rectal carcinoid tumor has been increasing probably due to the increased interest on screening colonoscopy and the advancement of endoscopic imaging technology. As the rectal carcinoid shows a wide range of clinical characteristics such as metastasis and long-term prognosis depending on the size and histologic features, it is a challenge to give a consistent diagnostic code in patients with the rectal carcinoid. If the rectal carcinoid tumor is less than 1 cm in size, it can be given as the code of definite malignancy or the code of uncertain malignant potential according to International Classification of Diseases for Oncology (ICD-O) by World Health Organization (WHO). Because patients get different amount of benefit from the insurance company based on different diagnostic codes, this inconsistent coding system has caused a significant confusion in the clinical practice. In 2019, WHO updated ICD-O and Statistics Korea subsequently changed Korean Standard Classification of Diseases (KCD) including the code of rectal carcinoid tumors. This review will summarize what has been changed in recent ICD-O and KCD system regarding the rectal carcinoid tumor and surmise its clinical implication.

Should accidental eccentricity be eliminated from Eurocode 8?

  • Anagnostopoulos, S.A.;Kyrkos, M.T.;Papalymperi, A.;Plevri, E.
    • Earthquakes and Structures
    • /
    • 제8권2호
    • /
    • pp.463-484
    • /
    • 2015
  • Modern codes for earthquake resistant building design require consideration of the so-called accidental design eccentricity, to account for torsional response caused by several factors not explicitly considered in design. This provision requires that the mass centres in the building floor be moved a certain percentage of the building's dimension (usually 5%) along both the x and y axes and in both positive and negative directions. If one considers also the spatial combinations of the two component motion in a dynamic analysis of the building, the number of required analyses and combinations increases substantially, causing a corresponding work load increase for practicing structural engineers. Another shortcoming of this code provision is that its introduction has been based primarily on elastic results from investigations of oversimplified, hence questionable, one story building models. This problem is addressed in the present paper using four groups of eccentric braced steel buildings, designed in accordance with Eurocodes 3 (steel) and 8 (earthquake design), with and without accidental eccentricities considered. The results indicate that although accidental design eccentricities can lead to somewhat reduced inelastic response demands, the benefit is not significant from a practical point of view. This leads to suggestions that accidental design eccentricities should probably be abolished or perhaps replaced by a simpler and more effective design provision, at least for torsionally stiff buildings that constitute the vast majority of buildings encountered in practice.