• Title/Summary/Keyword: cod

Search Result 3,275, Processing Time 0.023 seconds

Mixing effect on organic removal efficiency in treating low-strength wastewater using a modified anaerobic filter reactor (변형 혐기성 여상 반응조에서 교반강도가 유기물 제거효율에 미치는 영향)

  • 정병곤;이헌모
    • Journal of Environmental Science International
    • /
    • v.5 no.4
    • /
    • pp.513-524
    • /
    • 1996
  • Laboratory investigation was conducted to evaluat the mixing effects on organic removal efficiency to treat low-strength synthetic wastewater using modified anaerobic - filter reactor combining anaerobic filter and upflow anaerobic sludge blanket. Using the modified process the low-strength wastewater like municipal sewage could be treated with 85% T-COD removal efficiency at hydraulic retention time of 6 hours. At the constant organic loading of 0.5 kg COD/m 3-day, the organic removal efficiency and effluent COD concentration are increased as influent COD concentration increased from 125 mg/l to 500 mg/l. Mixing effects on organic removal efficiency are evident and optimum mixing speed is found as 50RPM. Placing the granular sludge and media on which slime layer was pre-formed into the reactor seemed to be very effective In achieving short start-up period. Therefore, the steady state was achived after 4 weeks and 1 week based on T-COD and S-COD, respectively.

  • PDF

Ammonia Effects on Anaerobic Digestion of Swine Wastewaters (양돈폐수의 혐기성 소화에 대한 암모니아의 영향)

  • Kim, Jong-Soo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.10 no.1
    • /
    • pp.102-108
    • /
    • 2002
  • The effects of ammonia on mesophilic anaerobic digestion were investigated by operating lab-scale two-stage ASBF reactors using swine wastewaters as influent without and with ammonia removal at HRT of 1-2 days and OLR of $2.2{\sim}9.6kg-COD/m^3{\cdot}d$ for 250 days. The COD removal efficiency and biogas generation of two-stage ASBF reactors was decreased by increasing influent ammonia concentrations to 1,580 mg(T-N)/L with increasing OLR to $6.3kg-COD/m^3{\cdot}d$, while those were increased by maintaining influent ammonia concentrations below 340 mg(T-N)/L by MAP precipitation with increasing OLR to $9.6kg-COD/m^3{\cdot}d$. Initial inhibirion of ammonia on anaerobic processes was observed at a concentration of 760 mg(T-N)/L and the COD removal efficiency and biogas generation dropped to 1/2 at ammonia concentration ranges of 1,540~1,870 mg(T-N)/L. It is essential to remove ammonia in swine wastewaters to an initial inhibition level before anaerobic processes for the effective removal of COD.

  • PDF

COD Removal of Rhodamine B from Aqueous Solution by Electrochemical Treatment

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.21 no.6
    • /
    • pp.655-659
    • /
    • 2012
  • This study elucidates the COD removal of dye (Rhodamine B) through electrochemical reaction. Effects of current density (7.2 to 43.3 $mA/cm^2$), electrolyte type (NaCl, KCl, $Na_2SO_4$, HCl), electrolyte concentration (0.5 to 2.0 g/L), air flow rate (0 to 4 L/min) and pH (3 to 11) on the COD removal of Rhodamine B were investigated. The observed results showed that the increase of pH decrease the COD removal efficiency. Whereas, the increase of current density;NaCl concentration and air flow rate caused the increase of the COD removal of Rhodamine B.

Anaerobic Treatment of High Strength Organic Wastewater by Granulated Microorganism (입상미생물을 이용한 고농도 유기성폐수의 혐기성처리)

  • Rim, Jay-Myoung;Han, Dong-Joon;Jun, Tae-Sung;Lee, Hyun-Joo
    • Journal of Industrial Technology
    • /
    • v.16
    • /
    • pp.61-70
    • /
    • 1996
  • This research aims to find granulation and organic removal of the piggery wastewater with the upflow blanket filter(UBF) reactor. UASB process had the effect of high pH on the granulation phase. But teh effect was decreased after the granule formation. The filter zone of the UBF reactor had the function of GSS and contributed to removing the organic because of its biofilm formation. The removal rates of total COD and soluble COD were 70% ~ 80% and 60 ~ 80% at an influent organic loading range of $2{\sim}17.4kgCOD/m^3{\cdot}d$, respectively. The methane production rate with the organic removal was $0.21{\sim}0.34{\ell}CH_4/gCOD_{rem}$ and the maximum methan production rate was $0.34CH_4{\ell}/gCOD_{rem}$ at the volumetric loading $5kgCOD/m^3{\cdot}d$.

  • PDF

Respirometry for COD Fractionation of Wastewater (미생물 호흡률 분석에 의한 하수의 유기물 분류)

  • Choi, Younggyun;Kim, Gyudong;Kim, Heejun;Kim, Yunjung;Chung, Taihak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.503-509
    • /
    • 2003
  • COD fractionation of primary settled municipal wastewater was conducted by respirometry. RBCOD (Readily Biodegradable COD) fraction was analyzed to be 21% of influent TCOD. However, SCOD fraction, analyzed by physical separation using $0.45{\mu}m$ membrane filter, was about 31% of TCOD. Therefore, 10% of soluble inert COD was comprised in TCOD. It means that kinetic analysis of activated sludge system was impossible because serious error would be occurred if SCOD was used as a biodegradable soluble component instead of RBCOD estimated from respirometry. In this study, RBCOD fraction of raw wastewater could be analyzed by respirometry within the error range of 57%. In addition, SBCOD (Slowly Biodegradable COD) content could be determined by kinetic simulation of the experimental results. SBCOD showed about 2-fold higher fraction (38% of TCOD) as compared with RBCOD.

Analysis of relationship between SS, COD, and T-P in rural area (농촌유역에서의 SS, COD 및 T-P간의 상관관계 분석(지역환경 \circled1))

  • 함종화;윤춘경
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.525-530
    • /
    • 2000
  • The loss of soil and nutrients from land surfaces to surface water supplies continues to be an important source of nonpoint source pollution. This study was initiate to develop an empirical relationship among the contaminants. SS, COD, T-N, and T-P were collected from agricultural surface water quality studies carried out in Hwasung-Gun, Kyonggi-Do. Correlation analysis, regression analysis, and reliability analysis were conducted. The regression equations were developed between SS and COD, SS and T-P, COD and T-P, and the resulting r$\^$2/ value was over 0.78. The regression equation enables a reasonable prediction of phosphorus concentration and COD concentration for known suspended solid concentration.

  • PDF

Electrochemical Determination of Chemical Oxygen Demand Based on Boron-Doped Diamond Electrode

  • Dian S. Latifah;Subin Jeon;Ilwhan Oh
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.215-221
    • /
    • 2023
  • A rapid and environment-friendly electrochemical sensor to determine the chemical oxygen demand (COD) has been developed. The boron-doped diamond (BDD) thin-film electrode is employed as the anode, which fully oxidizes organic pollutants and provides a current response in proportion to the COD values of the sample solution. The BDD-based amperometric COD sensor is optimized in terms of the applied potential and the solution pH. At the optimized conditions, the COD sensor exhibits a linear range of 0 to 80 mg/L and the detection limit of 1.1 mg/L. Using a set of model organic compounds, the electrochemical COD sensor is compared with the conventional dichromate COD method. The result shows an excellent correlation between the two methods.

Operation of High Performance Elutriation-Type Sludge Fermenter and Feasibility for Its Application (고성능 세정식 슬러지 산발효조의 운전 및 적용성 평가)

  • Ahn, Young-Ho;Speece, R.E.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.1
    • /
    • pp.85-92
    • /
    • 2005
  • The performance of a novel fermentation process, adopting a sludge blanket type configuration for higher hydrolysis/acidogenesis of the municipal primary sludge, was investigated under batch and semi-continuous conditions with various pH and temperature conditions. This acid elutriation slurry reactor provided higher system performance with a short HRT (5 days) and higher acidogenic effluent quality under pH 9 and thermophilic ($55^{\circ}C$) conditions. The hydrolysis of the sludge was revealed to be significantly dependent on seasonal effects for sludge characteristics but with little impact on acidogenesis. Based on the rainy season at the optimum conditions, VFA production and recovery fraction ($VFA_{COD}/COD$) were $0.18\;g\;VFA_{COD}\;g^{-1}\;VSS_{COD}$ and 63%. As byproducts, nitrogen and phosphorus releasing were $0.006\;g\;N\;g^{-1}\;VSS_{COD}$ and $0.003\;g\;P\;g^{-1}\;VSS_{COD}$, respectively. For the mass balance in a full-scale plant($Q=158,880\;m^3\;day^{-1}$) based on the rainy season, the VFA and non-VFA(as COD) production were $3,110\;kg\;VFA_{COD}\;day^{-1}$ and $1,800\;kg\;COD\;day^{-1}$, resulting in an increase of organics of $31\;mg\;COD\;L^{-1}$ and $20\;mg\;VFA_{COD}\;L^{-1}$ and nutrients of $0.7\;mg\;N\;L^{-1}$ and $0.3\;mg\;P\;L^{-1}$ in the influent sewage. The economical benefit from this process application was estimated to be about $67 per $1,000m^3$ of sewage except for energy requirements and also, better benefits can be expected during the dry season. Also, the results revealed that the process has various additional advantages such as pathogen-free stabilized solids production, excellent solids control and economical benefits.

Performance of Upflow Anaerobic Bioelectrochemical Reactor Compared to the Sludge Blanket Reactor for Acidic Distillery Wastewater Treatment (상향류식 혐기성 슬러지 블랭킷 반응조에 비교한 생물전기화학 반응조의 산성 주정폐수처리성능)

  • Feng, Qing;Song, Young-Chae;Yoo, Kyuseon;Lal, Banwari;Kuppanan, Nanthakumar;Subudhi, Sanjukta
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.6
    • /
    • pp.279-290
    • /
    • 2016
  • The performance of upflow anaerobic bioelectrochemical reactor (UABE), equipped with electrodes (anode and cathode) inside the upflow anaerobic reactor, was compared to that of upflow anaerobic sludge blanket (UASB) reactor for the treatment of acidic distillery wastewater. The UASB was stable in pH, alkalinity and VFAs until the organic loading rate (OLR) of 4.0 g COD/L.d, but it became unstable over 4.0 g COD/L.d. As a response to the abrupt doubling in OLR, the perturbation in the state variables for the UABE was smaller, compared to the UASB, and quickly recovered. The UABE stability was better than the UASB at higher OLR of 4.0-8.0 g COD/L.d, and the UABE showed better performance in specific methane production rate (2,076mL $CH_4/L.d$), methane content in biogas (66.8%), and COD removal efficiency (82.3%) at 8.0 g COD/L.d than the UASB. The maximum methane yield in UABE was about 407mL/g $COD_r$ at 4.0 g COD/L.d, which was considerably higher than about $282mL/g\;COD_r$ in UASB. The rate limiting step for the bioelectrochemical reaction in UABE was the oxidation of organic matter on the anode surface, and the electrode reactions were considerably affected by the pH at 8.0 g COD/L.d of high OLR. The maximum energy efficiency of UABE was 99.5%, at 4.0 g COD/L.d of OLR. The UABE can be an advanced high rate anaerobic process for the treatment of acidic distillery wastewater.

Evaluation of biological treatment of cutting-oil wastes using sequencing batch reactor (SBR) process (연속 회분식 반응조 (SBR) 공정을 이용한 폐절삭유의 생물학적 처리능 평가)

  • Baek, Byung-Do;Kim, Chang-Seop;Kim, Jun-Young;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1654-1660
    • /
    • 2009
  • Two different cutting-oils from H and B companies which are sold as an eco-friendly cutting-oils were selected and the biodegradability of these commercially available cutting-oils was evaluated by the sequencing batch reactor (SBR) processes. The cutting-oil wastes ($H_1$) pre-treated by coagulation/flocculation was used as an influent to SBR. When the F/M ratio was operated 0.04 to 0.08kgCOD/kgMLSS d, removals of $BOD_5$and $COD_{Cr}$were above 97% and 91%, respectively. T-N and T-P removals were above 76% and 81%, respectively. If the diluted cutting-oil wastes ($B_1$) was used as an influent of the SBR, $COD_{Cr}$removals were above 77% at the F/M ratio of 0.01-0.02kgCOD/kgMLSS d. After the cutting-oil wastes was treated by coagulation/ flocculation ($B_2$), $COD_{Cr}$removals was above 85%. If the pre-treated cutting-oil wastes were mixed with a synthetic wastewater ($B_3$) and fed into the SBR in order to mimic the real wastewater treatment plant situation, $BOD_5$and $COD_{Cr}$removals were above 97%, 91%, respectively. T-N and T-P removals were above 79% and 76%. The ratio between $BOD_5$and $COD_{Cr}$, ($COD_{Cr}$-$BOD_5$)/$COD_{Cr}$, indicating the biodegradability of effluent of the SBR, was calculated to 85% and 61%. This means that significant amounts of non-readily-biodegradable organic compounds in the effluent of $H_1$, $B_3$are still present.