• Title/Summary/Keyword: cocurrent

Search Result 26, Processing Time 0.024 seconds

Condensation Heat Transfer Coefficient in Horizontal Stratified Cocurrent Flow of Steam and Cold Water (물-증기 동방향 성층이상 유동에서의 응축 열전달 계수)

  • 김효정
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.5
    • /
    • pp.618-624
    • /
    • 1986
  • Some studies on direct-contact condensation in cocurrent stratified flow of steam and subcooled water were reviewed. Several approaches have been performed to develop the condensation heat transfer coefficient relationshipo. The local Nusselt number is correlated in terms of the local water Reynolds and Prandtl numbers as well as the steam Froude number. In addition, a turbulence-centered model, developed principally for gas absorption in several geometries, is modified by using calculated interfacial paramters for the turbulent velocity and length scales. These approaches result in a fairly good agreement with the data, whereas, the turbulence-centered model is here rexcommened since it is based on the turbulent properties which may be closely related to the condensation phenemena.

A Study on the Instability Criterion for the Stratified Flow in Horizontal Pipe at Cocurrent Flow Conditions

  • Sung, Chang-Kyung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.463-468
    • /
    • 1997
  • This paper presents a theoretical approach of the instability criterion from stratified to nonstratified flow in horizontal pipe at cocurrent flow conditions. The new theoretical instability criterion for the stratified and nonstratified flow transition in horizontal pipe has been developed by hyperbolic equations in two-phase flow, Critical flow condition criterion and onset of slugging at cocurrent flow condition correspond to zero and imaginary characteristics which occur when the hyperbolicity of a stratified two-phase flow is broken, respectively. Through comparison between results predicted by the present theory and the Kukita et al.[1] experimental data of pipes, it is shown that they are in good agreement with data.

  • PDF

Continuous Cocurrent Extraction of Milk Fat by Supercritical Carbon Dioxide (초임계이산화탄소에 의한 유지방의 연속 병류식 추출)

  • Lim, Sang-Bin;Syed S.H.Rizvi
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.23 no.3
    • /
    • pp.459-465
    • /
    • 1994
  • Performance of a continuous cocurrent supercritical fluid extraction column for processing of anhydrous milk fat (AMF) was determined. The extract loading increased and the extraction yield decreased as the superficial velocity of AMF increased. The maximum solubility of AMF in $CO_2$ at 4$0^{\circ}C$/3,500 psig was 0.0195g/g. The increase of the carbon dioxide density enhanced the solubility of milk fat and decreased the cholesterol concentration in the extract. Three operation conditions, such as recycle , reflux, and temperature gradient of extraction column, were tested. More short-chain fatty acvids were extracted by the reflux operation . Longchain fatty acids and thehighest ratio fo long-chain unsaturated to saturated fatty acids were also obtained in the raffinate phase with refluex.

  • PDF

The Characteristics of the Ozonation of the Phenol Wastewater in the Continuous PCR and BCR (연속식 PCR과 BCR에서 기$cdot$액 접촉 방법 및 주입 오존 유량에 따른 페놀 폐수의 오존 처리특성)

  • Kim, Yong-Dai;Ahn, Jae-Dong;Lee, Joon
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.1
    • /
    • pp.57-64
    • /
    • 1996
  • The main objectives of this research program were to study the ozonation characteristics of phenol wastewater in the continuous packed colamn reactor(PCR) and the bubble column reactor (BCR) using ozone and to provide the fundamentals of ozonizing the phenol wastewater. Among various influencing factors that affect on phenol decomposition through the oxidation by ozone, contacting method, and ozone flow rate were chosen as reaction parameters. The results were obtained from two different types of contacting methods where the countercurrent flow was more efficient than the cocurrent flow in both the phenol removal efficiency and the ozone utilization efficiency. Furthermore, PCR showed the phenol removal efficiency 1.6 to 3% higher than that of BCR in both contacting methods, as well as the ozone utilization efficiency, suggesting that the countercurrent flow is more efficient than the cocurrent flow. The phenol removal efficiency and the ozone utilization efficiency were reduced in both reactors as the influent ozone flow rate increased. Upon varing flow rate from 0.5l/min to 2.0 l/min by 0.5 l/min, the phenol removal efficiency was reduced approximately from 8.5% to 10.5% and the ozone utilization efficiency was reduced approximately from 6% to 8% in both reactors. The performance of PCR was superior to that of BCR in the aspects of phenol removal and ozone utilization efficiency.

  • PDF

Separation and Recovery of Indole from Model Coal Tar Fraction by Batch Cocurrent 5 Stages Equilibrium Extraction (회분 병류 5단 평형추출에 의한 모델 콜타르 유분 중에 함유된 Indole의 분리 및 회수)

  • Kim, Su Jin;Chun, Yong Jin;Jeong, Hwa Jin
    • Applied Chemistry for Engineering
    • /
    • v.18 no.2
    • /
    • pp.168-172
    • /
    • 2007
  • The separation of indole from a model mixture comprising four kinds of nitrogen heterocyclic compounds [indole (In), quinoline (Q), iso-quinoline (iQ), quinaldine (Qu)], three kinds of bicyclic aromatic compounds [1-methylnaphthalene (1MN), 2-methylnaphthalene (2MN), dimethylnaphthalene (DMN)], biphenyl (Bp) and phenyl ether (Pe) was examined by batch cocurrent 4 stages equilibrium extraction. The model mixture used as a raw material in this work was prepared according to the components and compositions contained in coal tar fraction (the temperature ranges of fraction: $240{\sim}265^{\circ}C$). An aqueous solution of formamide was used as a solvent. Indole was recovered more than 99% through 4 stages of the equilibrium extraction. The range of selectivity of indole in reference to DMN obtained through the 5 stages equilibrium extraction was found to be 63~118. The process for separation and recovery of indole contained in coal tar was studied by using the experimental results obtained from this work and the previous work.

Numerical Analysis for Separation of Methane by Hollow Fiber Membrane with Cocurrent Flow (병류흐름 중공사 분리막에 의한 메탄 분리 수치해석)

  • Lee, Seungmin;Seo, Yeonhee;Kang, Hanchang;Kim, Jeonghoon;Lee, Yongtaek
    • Korean Chemical Engineering Research
    • /
    • v.53 no.3
    • /
    • pp.295-301
    • /
    • 2015
  • A theoretical analysis was carried out to examine the concentration behavior of methane from a biogas using a polysulfone membrane. After the governing equations were derived for the cocurrent flow mode in a membrane module, the coupled nonlinear differential equations were numerically solved with the Compaq Visual Fortran 6.6 software. At the typical operating condition of mole fraction of 0.7 in a feed stream, the mole fraction of methane in the retentate increased to 0.76 while the normalized retentate flow rate to the feed flow rate decreased from 1 to 0.79. When either the mole fraction of methane in a feed increased or the pressure of the feed stream increased, the methane mole fraction in the retentate increased. On the other hand, it was found that as either the membrane area decreased or the ratio of the permeate pressure to the feed pressure increased, the methane mole fraction in the retentate decreased. In case that the stage cut increased, the methane mole fraction in the retentate increased while the recovery of methane slightly decreased.

Numerical Analysis for Separation of Carbon Dioxide by Hollow Fiber Membrane with Cocurrent Flow (병류흐름의 중공사 분리막에 의한 이산화탄소 분리 수치 해석)

  • Lee Yong-Taek;Song In-Ho;Ahn Hyo-Seong;Lee Young-Jin;Jeon Hyun-Soo;Kim Jeong-Hoon;Lee Soo-Bok
    • Membrane Journal
    • /
    • v.16 no.3
    • /
    • pp.204-212
    • /
    • 2006
  • A numerical analysis was carried out for separation of carbon dioxide from carbon dioxide/nitrogen gas mixture by a polyethersulfone hollow fiber membrane which has shown a good stability against plasticization by carbon dioxide and an excellent separation efficiency fur carbon dioxide from its gas mixture. A computer program for carbon dioxide separation was developed using the Compaq Visual Fortran 6.6 software. Governing module equations were thought to be an initial-value problem and the nonlinear ordinary differential equations were simultaneously solved using the Runge-Kutta-Verner fifth-order method. From results of numerical analysis, the carbon dioxide partial pressure of the feed stream, the pressure ratio of the feed side to the permeate side and the feed gas residence time at the inside of a membrane were found to be very important factors to affect the permeation characteristics of carbon dioxide.

Mass Transfer Characteristics of the Carbon Dioxide-Water Slug Flow in Vertical Small-Bore Tubes (작은 직경의 수직관을 흐르는 이산화탄소-물 슬러그 유동의 물질전달 특성)

  • Lee, Kyung-Jae;Kim, Dong-Seon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.401-408
    • /
    • 2012
  • Volumetric mass transfer coefficient was measured with carbon dioxide and deionized water for the gas-liquid cocurrent slug flow in 2, 5 and 8 mm tubes. Measurement was repeated with and without a vertical section in an experimental setup and entrance effect was found greater for smaller tubes. Volumetric mass transfer coefficient in the vertical section was found generally a strong function of gas- and liquid-phase superficial velocities. 5 mm- and 8 mm-tube data are highly consistent each other but not with 2 mm tube.

Measurement of the Void Fraction in Slug Flow using an Optical Method (광학적 방법을 이용한 슬러그 유동의 기공률 측정)

  • Kim, Dong-Seon
    • Journal of Institute of Convergence Technology
    • /
    • v.1 no.2
    • /
    • pp.25-28
    • /
    • 2011
  • Void fraction has been measured for the gas-liquid cocurrent slug flow in 8mm vertical acrylic tube using an optical method. Bubble speed, length and period could be measured with the two sets of laser-infrared sensor modules mounted 25mm apart alongside the tube, which were designed to detect variation of light intensities with a time delay when two parallel laser beams were refracted successively by a passing bubble. It was found that the results were in good agreement with the previous studies in the literature suggesting that the method used in this study were sound and accurate.

  • PDF

An experimental study on mechanism for the disintegration of liquid film surface waves by a parallel air flow (평행공기류에 의한 액막류 표면파의 분열기구에 관한 실험적 연구)

  • 이규영;양옥용
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.81-90
    • /
    • 1992
  • This paper deals with an experimental study on the initial condition of liquid film surface waves disintegration and investigation on the behavior of liquid film surface waves formed by the high speed air flow on the solid plane surface. The authors conducted the qualitative and quantitative study to in vestigate the liquid film flow phenomena, the liquid film disintegration mechanism, and droplet formation process with breaking the liquid film surface wave. The newly devised transparent rectangular test section which has semi-two-dimensional flow at the center of the bottom was introduced to perform the experimental study, and it can generate the uniform thickness liquid film at the bottom. The strobo streak camera was used to obtain the instantaneously transformed photographs. The electronic measuring device was also used to measure the liquid film thickness variation in order to perform the easy and effective analysis of complex flow phenomena in the air-water cocurrent flow.

  • PDF