• Title/Summary/Keyword: cobalt chloride

Search Result 101, Processing Time 0.021 seconds

Diagnostic Value of the Cobalt($^{58}Co$) Excretion Test in Iron Deficiency Anemia (철결핍성빈혈(鐵缺乏性貧血)에서 Cobalt($^{58}Co$)배설율검사(排泄率檢査)의 진단적(診斷的) 가치(價値))

  • Sihn, Hyun-Chung;Hong, Kee-Suck;Cho, Kyung-Sam;Song, In-Kyung;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.10 no.1
    • /
    • pp.21-34
    • /
    • 1976
  • The diagnosis of iron deficiency rests upon the correct evaluation of body iron stores. Morphological interpretation of blood film and the red cell indices are not reliable and often absent in mild iron deficiency. Serum iron levels and iron-binding capacity are more sensitive indices of iron deficiency, but they are often normal in iron depletion and mild iron deficiency anemia. They are also subject to many variables which may introduce substantial errors and influenced by many pathologic and physiologic states. Examination of the bone marrow aspirate for stainable iron has been regarded as one of the most sensitive and reliable diagnostic method for detecting iron deficiency, but this also has limitations. Thus, there is still need for a more practical, but sensitive and reliable substitute as a screening test of iron deficiency. Pollack et al. (1965) observed that the intestinal absorption of cobalt was raised in iron-deficient rats and Valberg et al. (1969) found that cobalt absorption was elevated in patients with iron deficiency. A direct correlation was demonstrated between the amounts of radioiron and radiocobalt absorbed. Unlike iron, excess cobalt was excreted by the kidney, the percentage of radioactivity in the urine being directly related to the percentage absorbed from the gastrointestinal tract. Recently a test based on the urinary excretion of an oral dose of $^{57}Co$ has been proposed as a method for detecting iron deficiency. To assess the diagnostic value of urinary cobalt excretion test cobaltous chloride labelled with $1{\mu}Ci\;of\;^{58}Co$ was given by mouth and the percentage of the test dose excreted in the urine was measured by a gamma counter. The mean 24 hour urinary cobalt excretion in control subjects with normal iron stores was 6.1% ($1.9{\sim}15.2%$). Cobalt excretion was markedly increased in patients with iron deficiency and excreted more than 29% of the dose. In contrast, patients with anemia due to causes other than iron deficiency excreted less than 27%. Hence, 24 hour urinary cobalt excretion of 27% or less in a patient with anemia suggets that the primary cause of the anemia is not iron deficiency. A value greater than 27% in an anemic subject suggests that the anemia is caused by iron deficiency. The cobalt excretion test is a simple, sensitive and accurate method for the assessment of body iron stores. It may be particularly valuable in the epidemiological studies of iron deficiency and repeated evaluations of the body iron stores.

  • PDF

Effect of Nozzle Tip Size on the Preparation of Nano-Sized Cobalt Oxide Powder by Spray Pyrolysis Process (분무열분해 공정에 의한 코발트 산화물 나노 분체 제조에 미치는 노즐 팁 크기의 영향)

  • Kim, Dong Hee;Yu, Jae Keun
    • Resources Recycling
    • /
    • v.25 no.6
    • /
    • pp.41-49
    • /
    • 2016
  • The present study was intended to prepare cobalt oxide ($Co_3O_4$) powder of average particle size 50 nm or less by spray pyrolysis reaction using the raw cobalt chloride ($CoCl_2$) solution, in order to identify the change in the nature of the particles according to the change in the nozzle tip size. When the nozzle tip was 1 mm, it turned out that most of the droplets were spherical and the surface showed very tight structure. The average particle size of the finally formed particles was 20-30 nm. When the nozzle tip size was 2 mm, some of the droplets formed were spherical, but a considerable part of them showed severely disrupted form. particles formed showed an average particle size of 30 - 40 nm. For the nozzle tip size of 5 mm, spherical droplets were almost non-existent and most were in badly fragmented state. The tightness of surface structure of the droplets has greatly been reduced compared with other nozzle tip sizes. Average size of the formed particles was about 25 nm. As the nozzle tip size increased from 1 mm to 2 mm and 3 mm, the intensities of the XRD peaks have changed little, but significantly been reduced when the nozzle tip size increased to 5mm. As the nozzle tip size increased from 1 mm to 2 mm, the specific surface area of the particles decreased, but the nozzle tip size increased to 5mm, the specific surface area remarkably increased.

Sol-Gel Encapsulation as Matrix for Potentiometric Nitrite-Selective Membranes Doped with Chloro (5, 10, 15, 20-Tetraphenylporphyrinato) Cobalt (III)

  • Zhou, Hao;Meyerhoff, Mark E.;Bi, Kai-Shun;Park, Sung-Bae
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.4
    • /
    • pp.335-341
    • /
    • 2009
  • Organic-inorganic hybrid sol-gel matrices were used as hosts for chloro (5, 10, 15, 20-tetraphenylporphyrinato) cobalt (III) (Co[TPP]Cl), a known ionophore for nitrite. The sol-gel precursor was prepared by the reaction of (3-isocyanopropyl) triethoxysilane with 1,4-butanediol. An appropriate amount of the anion-exchanger, tridodecylmethylammonium chloride (TDMAC) and the plasticizer, tributylphosphate (DBP) were used as membrane additives. On mixing with an acidic catalyst, the sol-state precursors slowly gelled, yielding a membrane in which the active components, Co[TPP]Cl and TDMAC, were encapsulated. The performances of the sol-gel membrane-based electrodes were compared to those of Co[TPP]Cl-based poly(vinyl chloride) (PVC) membrane electrodes. Membranes with a molar ratio of Co[TPP]Cl: TDMAC (1 : 0.1) showed reasonable response slopes toward nitrite. The response slopes were typically 53 mV/decade between $10^{-5.4}$ and $10^{-1.0}\;M$. Selectivities toward nitrite over hydrophilic and small anions such as chloride were somewhat inferior to those observed with PVC-based membranes, but selectivities over lipophilic anions were quite similar. Reduced asymmetry potentials due to protein adsorption were found to occur with the sol-gel matrix relative to PVC-based films when the sensors were employed as a detector in flow-through configuration.

Solvent Extraction of Copper from $CuCl_2-NiCl_2-CoCl_2$ Solutions by Alamine336 and LIX84 ($CuCl_2-NiCl_2-CoCl_2$용액으로부터 Alamine336과 LIX84에 의한 구리의 용매추출)

  • Lee Man-Seung;Ahn Jong-Gwan;Ahn Jae-Woo
    • Resources Recycling
    • /
    • v.11 no.6
    • /
    • pp.12-17
    • /
    • 2002
  • Solvent extraction experiments have been performed to separate copper from $CuCl_2$-$NiCl_2$-$CoCl_2$$ solutions using Alamine336 and LIX84. The complex formation tendency between metal ions and chloride ion had a great effect on the distribution coefficients of Cu, Co and Ni ions and separation factor of Cu to Co and Ni. In the experimental ranges of chloride ion concentration from 0.5 to 4.0 M, LIX84 was superior to Alamine336 in separating copper from cobalt. When the volume percentage of LIX84 and Alamine336 was varied from 5 to 40%, LIX84 was more effective than Alamine336 in separating Cu from Co and Ni in solutions in which the chloride ion concentration was 1.0 M.

Preparation and Chrominance of Metal Oxide Coated Titania/Mica Pearlescent Pigment (금속산화물이 코팅된 마이카 티타니아 진주광택 안료의 제조 및 색차변화)

  • Lee, Kwan-Sik;Kang, Kuk-Hyoun;Lee, Jin-Hee;Lee, Dong-Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.233-243
    • /
    • 2013
  • The inorganic pearlescent pigment have high physical and chemical stability, thus it is used in a variety field, which has better light stability, solvent resistance and thermostability. In this paper, we were synthesized the pearlescent pigment for cosmetics which was coated cobalt chloride for base of blue color metal oxide on mica titania substrate using hydrothermal synthesis method. To complement the color of the pigment by cobalt, pearl pigment were coated by different metal salt and cobalt ratio, to implement a variety of color value, depending on the kind of metal salts were synthesized. Synthesized pearlescent pigments appear various color as kind of added metal salt precursor and molar ration of cobalt and other metals. We controlled coating and color by composition of metal salt and type of metal salts, and that confirm the pigment characteristics of color changes through the analysis of color difference meter. Synthesized pigment was characterized by SPM, SEM, XRD, and EDS.

Synthesis and Equilibria of Octahedral and Tetrahedral Complexes of Cobalt (II) 2,2'-Dipyridylamine

  • Paik Suh Myunghyun;Oh Young-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.3 no.1
    • /
    • pp.5-9
    • /
    • 1982
  • Reactions of cobalt(II) chloride with 2,2'-dipyridylamine (dpa) in alcoholic solutions afford the complex of octahedral $Co(dpa)_2Cl_2{\cdot}CH_3OH$. The octahedral complex is converted to tetrahedral $Co(dpa)Cl_2$ in certain solvents or at the elevated temperature, and the tetrahedral complex is changed to the octahedral one with added dpa. The electronic spectra of the complexes in DMF, measured with various concentrations of 2,2'-dipyridylamine, establish the equilibrium; $td-Co(dpa)Cl_2+dpa_\rightleftarrows^Koh-Co(dpa)_2Cl_2$. The equilibrium constants determined by the analysis of the visible spectra are 6.4, 3.6 and 2.0 $M^{-1}$, respectively, at 25.5, 38.0 and $49.0^{\circ}C,\;with\;{\Delta}H^{\circ}\;and\;{\Delta}S^{\circ}$being -9.5 kcal/mole and -28 eu.

Purification and Characterization of a Fibrinolytic Enzyme from Snake Venom of Macrovipera lebetina turanica

  • Kwon, Ki-Rok;Park, Do-Il;Lee, Seung-Bae;Choi, Suk-Ho
    • Journal of Pharmacopuncture
    • /
    • v.14 no.2
    • /
    • pp.5-14
    • /
    • 2011
  • Objectives: Fibrinolytic enzyme preparations were isolated from the snake venom of Macrovipera lebetica turanica in this study. Methods: The purity of the preparations was determined using SDS-PAGE and the enzymic characteristics of the purified fibrinolytic enzyme were determined. Results: 1. All of the two preparations with fibrinolytic activity obtained from the snake venom of M. l. turanicat contained the major polypeptide with the molecular weight of 27,500. One of the preparation showed purified fibrinolytic enzyme. 2. The purified fibrinolytic enzyme hydrolyzed ${\alpha}$-chain of fibrinogen faster than ${\beta}$-chain but not ${\gamma}$-chain. 3. The fibrinolytic activity was inhibited completely by EDTA, EGTA, 1,10-phenanthroline, and dithiothreitol. 4. The fibrinolytic activity was inhibited completely by calcium chloride, iron(III) chloride, mercuric chloride, and cobalt (II) chloride. 5. The fibrinolysis zone formed after addition of zinc sulfate was smaller but clearer than the control. Conclusions: These results suggested that the fibrinolytic enzyme purifed from the snake venom of M. l turanica was a metalloprotease containing dithiol group.

Effect of NH4Cl on the Electrodeposition of Cobalt/Phosphorus Alloy (CoP합금의 전기도금 시 NH4Cl의 영향에 관한 연구)

  • Lee, Kwan-Hyi;Jeung, Won-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.5 no.2
    • /
    • pp.57-61
    • /
    • 2002
  • In this study, the effect of ammonium chloride on the electrodeposition of CoP magnetic alloy film was investigated. The correlation between the electrodeposition condition and the magnetic properties was tried to elucidate by the electro- analytical tests such as cyclic voltammetry. It was observed that the magnetic properties of the films were varied extensively with the ammonium chloride contents in the solution. The reason why the magnetic properties of the films were varied with the addition of ammonium chloride was thought that the addition of ammonium chloride controlled the electrocrystallization of CoP kinetically by charge transfer and increased the grain size and the orientation factor. This may cause the variation of the magnetic properties of CoP films.

Protection of Primary Cultured Mouse Hepatocytes from Chemical Hypoxia-induced Injury by Hydrogen Sulfide (화학적 허혈에 의해 손상된 마우스 간세포에 대한 hydrogen sulfide의 간세포 보호 효과)

  • Lee, Min Young
    • Journal of Life Science
    • /
    • v.23 no.11
    • /
    • pp.1342-1350
    • /
    • 2013
  • We examined the effect of hydrogen sulfide ($H_2S$) in chemical hypoxia-induced injury in mouse hepatocytes. Cell viability was significantly decreased by cobalt chloride ($CoCl_2$), a well-known hypoxia mimetic agent in a time- and dose- dependent manner. Sodium hydrosulfide (NaHS, a donor of $H_2S$) pretreatment before exposure to $CoCl_2$ significantly attenuated the $CoCl_2$-induced decrease of cell viability. $CoCl_2$ treatment resulted in an increase of intracellular ROS generation, which is inhibited by NaHS or N-acetyl-cysteine (NAC, a ROS scavenger), and p38 MAPK phosphorylation, which is also blocked by NaHS or NAC. The $CoCl_2$-induced increase of the Bax/Bcl-2 ratio was attenuated by NaHS, NAC, and SB 203580 (p38 MAPK inhibitor). The $CoCl_2$-induced decrease of cell viability was also attenuated by NaHS, NAC, and SB 203580 pretreatment. Additionally, NaHS inhibited the $CoCl_2$-induced COX-2. Similar to the effect of NaHS, NAC blocked $CoCl_2$-induced COX-2 expression. Furthermore, NS-398 (a selective COX-2 inhibitor) attenuated not only the $CoCl_2$-induced increase of the Bax/Bcl-2 ratio, it also decreased cell viability. Taken together, $H_2S$ protects primary cultured mouse hepatocytes against $CoCl_2$-induced cell injury through inhibition of the ROS-activated p38 MAPK cascade and the COX-2 pathway.

SENSITIVITY TO NICKEL, COBALT, CHROME, & COFFER IN DENIAL ALLOYS (치과 보철물 합금 성분중 니켈, 코발트, 크롬 및 구리에 대한 감작률에 관한 조사 연구)

  • Park Young-Mi;Choi Dae-Gyun;Choi Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.155-166
    • /
    • 1992
  • In dentistry, precious metal alloys are, mainly due to economic factors, increasingly displaced by alternatives containing Ni-Cr-Co. There are some reports where hypersensitive reactions to Ni-Cr-Co alloys are presented and discussed. The reactions reported vary from mucosa contact stomatitis to generalized dermatitis without any oral mucosal reaction. The purpose of this study was to investigate the incidence of nickel, chrome, cobalt and copper, and to know whether subjects with positive skin reaction to nickel would also demonstrate adverse intraoral reaction to a non-precious metal nickel. The patch tests were performed in 81 subjects(male 39, female 42) and nickel sulfate 5% aq., potassium bichromate 0.5% at., cobalt chloride 2% aq., & copper sulfate 1% aq., were used for test allergens. And then the intraoral tests were performed in 16 subjects, 8 subjects with positive allergic skin reaction to nickel and 8 subjects with negative allergic skin reaction. A pure metallic nickel plate was attached to the buccal side of the upper second premolar. The results are as follows : 1. The frequency of nickel sensitivity was 9.9% (2 men, 6 women), cobalt was 4.9% (1 man, 3 women), and chrome was 2.5% (2 men) respectively and there was no positive reaction to copper 2. The positive reactions were 8 of 23 (34.8%) with a history of jewelry allergic reactions and 3 of 58 (5.1%) without a history of jewelry allergic reactions. 3. Three of 8 subjects with positive skin reaction. gave reactions to the metal plates.

  • PDF