• Title/Summary/Keyword: coaxial cable sensor

Search Result 18, Processing Time 0.021 seconds

Study on the Building Method of a Sensor Network based on BLE Beacons with WPTS (WPTS BLE 비콘 기반 센서 네트워크 구축 방안 연구)

  • Jang, Ho-Deok
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.1
    • /
    • pp.8-13
    • /
    • 2022
  • This paper investigates the method to implement a RF (Radio Frequency) energy harvesting sensor node and to build a sensor network using a CATV network and a leaky coaxial cable. The power supply of a sensor node is designed with the WPTS (Wireless Power Transfer System) receiver operating at 915MHz. A sensor network has limited coverage by the loss of RF signal at a wireless transmission link. The paper proposes to build a sensor network that the BLE signal of a sensor and the signal of a WPTS power transmitter are transmitted through a coaxial cable of a CATV network by utilizing WOC (WiFi over Coax) technology and radiates at a leaky coaxial cable. The length of a leaky coaxial cable and the total loss of a wire link are allowed to the point that the RSSI of a sensor node is more than the minimum value (-78dBm) and lead to extend wireless coverage.

A practical modification to coaxial cables as damage sensor with TDR in obscured structural members and RC piles

  • Mehmet Ozgur;Sami Arsoy
    • Structural Monitoring and Maintenance
    • /
    • v.10 no.2
    • /
    • pp.133-154
    • /
    • 2023
  • Obscured structural members are mostly under-evaluated during condition assessment due to lack of visual inspection capability. Insufficient information about the integrity of these structural members poses a significant risk for public safety. Time domain reflectometry (TDR) is a novel approach in structural health monitoring (SHM). Ordinary coaxial cables "as is" without a major modification are not suitable for SHM with TDR. The objective of this study is to propose a practical and cost-effective modification approach to commercially available coaxial cables in order to use them as a "cable sensor" for damage detection with the TDR equipment for obscured structural members. The experimental validation and assessment of the proposed modification approach was achieved by conducting 3-point bending tests of the model piles as a representative obscured structural member. It can be noted that the RG59/U-6 and RG6/U-4 cable sensors expose higher strain sensitivity in comparison with non-modified "as is" versions of the cables used. As a result, the cable sensors have the capability of sensing both the presence and the location of a structural damage with a maximum aberration of 3 cm. Furthermore, the crack development can be monitored by the RG59/U-6 cable sensor with a simple calibration.

A Study on the Partial Discharge Location Method using 2 Sensors (2개 센서를 이용한 부분방전 위치추정 기법 연구)

  • Kim, Jeong-Tae;Kim, Dong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.251-256
    • /
    • 2012
  • This study deals with the location of partial discharges(PDs) for power cables and GIS using 2 PD sensors and long coaxial signal cables. Throughout the experiments by use of simulated PD pulses and corona discharges in the power cable system, it is found out that the impedance matching between the coaxial signal cable and the measuring equipment should be done for good S/N ratio and the on-site measurement using more than 100m-long coaxial signal cable is possible. In addition, new PD location algorithm with the polarities of PD pulses and the arrival time difference between two pulses was proposed and was proved through the partial discharge experiments for the cable joint defect and artificial void defect.

Characteristics of Coaxial Typed Magnetic Sensor Using Amorphous Wire (자성와이어를 이용한 동축케이블형 자계센서의 특성)

  • Kim, Y.H.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.2
    • /
    • pp.55-59
    • /
    • 2007
  • Co-based amorphous magnetic wire with a diameter of $125{\mu}m$ and a length of 40 mm was used as an inner conductor of a coaxial cable to construct a magnetic sensor. Sensor characteristics was measured up to 3 GHz with applied up to 60 Oe by using network analyzer. Frequency dependence of impedance for this sensor was very close to the impedance resonant pattern of transmission line and 250 MHz was obtained as a 1/4 wavelength without external magnetic field. Large impedance change was measured in the magnetic field range between 0 Oe and 1 Oe, which was influenced by permeability change of magnetic amorphous wire. Because ${\Delta}Z/{\Delta}H$ value of $300{\Omega}/Oe$ was obtained at 0.1 Oe, this coaxial cable with amorphous wire can be useful as a magnetic sensor.

Crack mapping in RC members using distributed coaxial cable crack sensors: modeling and application

  • Greene, Gary Jr.;Belarbi, Abdeldjelil;Chen, Genda
    • Smart Structures and Systems
    • /
    • v.1 no.4
    • /
    • pp.385-404
    • /
    • 2005
  • The paper presents a model to calculate reinforcement strain using measured crack width in members under applied tension, flexure, and/or shear stress. Crack mapping using a new type of distributed coaxial cable sensors for health monitoring of large-scale civil engineering infrastructure was recently proposed and developed by the authors. This paper shows the results and performance of such sensors mounted on near surface of two flexural beams and a large scale reinforced concrete box girder that was subjected to cyclic combined shear and torsion. The main objectives of this health monitoring study was to correlate the sensor's response to strain in the member, and show that magnitude of the signal's reflection coefficient is related to increases in applied load, repeated cycles, cracking, and reinforcement yielding. The effect of multiple adjacent cracks, and signal loss was also investigated. The results shown in this paper are an important step in using the sensors for crack mapping and determining reinforcement strain for in-situ structures.

Measurement of Complex Permittivity and Permeability for Powder-type Materials (분말재료의 복소 유전율 및 투자율 측정)

  • Park, Sang-Bok;Lee, Jang-Soo;Chong, Young-Seek;Cheon, Chang-Yul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2196-2201
    • /
    • 2007
  • Materials used at microwave are usually used as a dielectric with a manufacturing purpose of printed circuit boards, etc. Complex permittivity of them can be measured from attenuation constant or propagation constant of a transmission line using a microstrip line with bulk type. But as the technique recently which can manufacture to have complex permittivity and permeability demanded using nonferrous metals for powder-type grows up, we need sensors and methods which can measure characteristics of powder-type materials. So far measuring methods of permittivity and permeability with waveguide or coaxial cable are used but they have faults which have a complex measurement method and are difficult to simultaneously measure permittivity and permeability. In this paper, a simultaneous measuring method of permittivity and permeability with 2-port coaxial cable and a new proposed calculation. The proposed 2-port coaxial cable is designed to be easy to insert materials and to have a wideband. We measure permittivity and permeability of magnetic powder(Ni-Fe-Mo, Ni-Fe) which reveal its characteristic at $0.3{\sim}1.3GHz$ to identify the proposed sensor.

Optimization of Operation Frequency of Orthogonal Fluxgate Sensor Fabricated with Co Based Amorphous Wire

  • Kim, Young-Hak;Kim, Yongmin;Yang, Chang-Seob;Shin, Kwang-Ho
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.159-162
    • /
    • 2013
  • We present how to optimize the operation condition including frequency of the orthogonal fluxgate sensor in this paper. The orthogonal fluxgate sensor was fabricated with a Co-based amorphous wire with 10 mm long and 100 ${\mu}m$ in the diameter and a 270-turn pickup coil wound on the amorphous wire. In order to investigate the frequency dependence of the sensitivity, output spectra of the sensor which was connected by using a coaxial cable with various lengths of 0.5-5 m were measured with a RF lock-in amplifier. The maximum sensitivities were obtained at different frequencies according to coaxial cable lengths. It was found that the optimal operation frequencies, at which maximum sensitivities were appeared, were almost identical to the frequencies of impedance resonance. The maximum sensitivity and optimal operation frequency were 1.1 V/Oe (${\approx}$ 11000 V/T) and 1.25 MHz respectively.

Method for Power control of Wired and Wireless linkage Sensor Network for Low-power Wireless network (저전력 무선 네트워크를 위한 유무선 연동 센서 네트워크의 전력 제어 방법)

  • Lee, Kyung-Sook;Kim, Hyun-Deok
    • Convergence Security Journal
    • /
    • v.12 no.3
    • /
    • pp.27-34
    • /
    • 2012
  • In this paper, using a new low-power consumption method for ZigBee device, which consume low-power using an output power control algorithm through RSSI monitoring as interlocking wireless network using ZigBee which has advantages of a low-power consumption, a low-cost, a compatibility and a draft international standardization enacted by IEEE and ZigBee Alliance, with wired network using built coaxial cable to overcome the disadvantage of the existing wireless sensor network, is proposed. Effectiveness of the output power control algorithm through RSSI monitoring has been verified by experimentation for more optimized low-power consumption.

Implementation of A Bridge Monitoring System Based on Ubiquitous Sensor Networks (USN기반의 교량 모니터링 시스템 구현)

  • Lee, Sung-Hwa;Jeon, Min-Suk;Lee, An-Kyu;Kim, Jin-Tae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.4
    • /
    • pp.1-8
    • /
    • 2009
  • The proposed real-time structural health monitoring(SHM) system in past transferred and received data, central server gathered data from sensors, through coaxial cable. an immense sum of money is required to structure sensor network using coaxial cable. This paper proposes USN-based structural health monitoring(SHM). AIso, this paper designs and realizes prototypes according to proposed SHM. The value of sensing data obtained through HSDPA transfer to the BMS(Bridge Monitoring Server) passing through the TCP / IP socket by building two-way communication system, We have implemented a complete graph converting full system.

  • PDF

Analysis of Slope Behavior Using TDR Sensor (TDR센서를 이용한 사면거동 해석)

  • Park, Min-Cheol;Lee, Jae-Ho;Han, Heui-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.79-86
    • /
    • 2010
  • In this paper, using soil slope inclinometer observations of lateral flow is used as a traditional way, but there are some decisions. Inclinometers in the process of installing and monitoring is costly. Severe incline slope of the lateral flow is observed in the inefficient. As a solution for it using TDR sensors are used to. Metal conductors such as coaxial cable and general cable uses a measurement sensor can be installed on site at a lower cost and slope measurements are available for long-term monitoring. When TDR sensor is installed on the slopes, changes in the behavior of slopes causes the earth pressure. TDR sensors determine the change of earth pressure and tried to analyze the behavior of slopes.

  • PDF