A Comparative Experiments for Tube Agglutination Test of Pullorum Antiserum with gamma-Ray 60Co Irradiated Salmonella pullorum (방사성동위원소(放射性同位元素)로 처리(處理)한 추백리균(雛白痢菌)의 응집반응(凝集反應)에 대한 비교시험(比較試驗))

  • Seo, Boo Kap
    • Korean Journal of Veterinary Research
    • /
    • v.16 no.1
    • /
    • pp.7-10
    • /
    • 1976
  • An agglutinability between naturally infected positive chicken serum of pullorum disease and hyperimmumized rabbit antiserum was compared. And the following results were obtained and summarized. 1. On the agglutinability, Salmonella pullorum antigen which irradiated gamma-ray was more excellent than another both formalized and heated antigen. 2. Time of judgemented as positive titer in the tube agglutination test to the naturally infected positive chicken serum was it most suitable for 12 hours at $37^{\circ}C$. 3. Agglutination titer of positive immune chicken serum against gamma-ray irradiate Salmonella pullorum were as 320~640x.

  • PDF

Development of diagnostic kit(Test-MT) for the microplate latex agglutination test of toxoplasmosis in animal (Latex 응집반응을 이용한 동물의 톡소플라즈마병 진단용 kit 개발에 관한 연구)

  • Suh, Myung-deuk;Joo, Hoo-don;Maass, Daivd
    • Korean Journal of Veterinary Research
    • /
    • v.35 no.3
    • /
    • pp.583-593
    • /
    • 1995
  • The present study was conducted to develop a toxoplasma latex agglutination test antigen(Test-MT) and evaluate the toxoplasma latex agglutination(LA) test using a newly-made "Test-MT kit" by comparing with the Toxo-MT kit(Eiken chemical co, Tokyo). Also, the specifity and sensitivity test were made by comparing with IFA test and IgG-ELISA. Tachyzoite suspensions of Toxoplasma gondii(RH strain) were ultracentrifuged for 30min at $60,000{\times}g(4^{\circ}C)$ and the supernatant was used as a water-lysate antigen. Polystyrene latex particles of $1.0{\mu}m$ in diameter(Polyscience co) were used for the preparation of sensitized latex-antigen supension(Test-MT). The frequency distribution of LA titers in Test-MT showed two peaks at <1:32 and 1:128. The borderline titer for positive test in Test-MT was determined to be 1:64. But the frequency distribution of LA tites in Toxo-MT showed two peaks at <1:16 and 1:64. The positive borderline was determined to be 1:32. Agreement of reactions between Test-MT and Toxo-MT kit by LA test was shown 92.5% in bovine sera and 97.0% in swine sera, respectively. From the results obtained here it was determined that the sensitized latex-antigen, Test-MT kit, for the microtiter agglutination test prepared as same as by the procedure described in the previous paper(Suh and Lee, 1993) was useful as a highly specific, sensitive and stable immunotiteration reagent for serodiagnosis of toxoplasma infection in animal sera.

  • PDF

Development of antigen for the microplate latex agglutination test on toxoplasmosis in animals (Latex 응집반응을 이용한 동물의 톡소플라즈마병 진단액 개발에 관한 연구)

  • Suh, Myung-deuk;Lee, Eung-goo
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.4
    • /
    • pp.623-632
    • /
    • 1993
  • This study was conducted to develop a sensitized latex-antigen for serodiagnosis of toxoplasmosis in animals. Tachyzoites of T gondii(RH-strain) harvested from mouse peritoneal cavity were purified through the filtraton of polycarbonate membrane(pore size, $3.0{{\mu}m}$, Costar Co.) and disrupted by ultrasonicator. The tachyzoite suspension was ultracentrifuged for 30 min at $60,000{\times}g(4{^{\circ}C})$ and the supernatant was used as a water-lysate antigen. Polystyrene latex particles of $0.8{{\mu}m}$ in diameter(Sigma) were used for the preparation of sensitized latex-antigen suspension. The several parameters including the preparation conditions, incubation buffer. serum dilution buffer and stability of agglutination reactions were evaluated and the results obtained were summarized as follows : 1. The antigen consisting of a water-lysate of T gondii tachyzoites was adsorbed onto polystyrene latex particles of $0.8{{\mu}m}$ in diameter by adding a latex suspension to an equal volume of diluted antigen solution and by incubating the mixture at $37{^{\circ}C}$ under different conditions. 2. The optimum incubation buffer used for the antigen sensitization was 0.1M Tris-HCl buffer(pH 8.0). 3. The optimum serum dilution buffer used for the latex agglutination test was 0.1M Tris-HCl-NaCl buffer(pH 7.4) containing 300 mM NaCl. But 0.1M Tris-HCl-NaCl buffer(pH 7.4) containing 300-600 mM NaCl, 0.5% BSA and 0.01% Tween-20 improved the agglutination pattems and cleared the background of microplate well without the effects on L.A titer. 4. The time required for antigen sensitization was 40 and 60 min in incubation buffer(pH 8.0) at $37{^{\circ}C}$. But the optimun time for antigen sensitization was min at $37{^{\circ}C}$. 5. The optimun quantity of antigen absorbed on latex particles for proper agglutination was the range of 20 to $32{\mu}g$ of latex particles. 6. The optimun concentration of the latex-antigen suspension for the proper agglutination reaction was determined as 0.2%(w/v). 7. The specificity, rapidity and simplicity of the latex-particle agglutination test suggested that it might be adaptable to large scale serum screening.

  • PDF

Server on the Distribution of Bovine Toxoplasma Antubodies by Latex Agglutination Test in Gyeongnam District (경남지역에서의 Latex응집반응을 이용한 소 톡소플라즈마 항체분포 조사)

  • 이병훈;류중운;황보원;변유성;조광제
    • Korean Journal of Veterinary Service
    • /
    • v.18 no.3
    • /
    • pp.36-41
    • /
    • 1995
  • This study was conducted to determine the serum antibodies against toxoplasma in bovine from gyeongnam district by latex agglutination(LA) test. LA test was carried out with Toxo-MT kit(Eikon chemical co). The result obtained were summerized as follow: 1. Positive rates of toxoplasma antibodies in 1,488 bovine sera was 5.0%(75 cases) by LA test. 2. The toxoplasma antibody detection rates against 823 korean cattle and 865 dairy cattle were 1.8%(11 cases) and 7.4%(64 cases) respectively. 3. In LA test serum antibody titers in 75 positive sera were shown as 54 cases(72.0% in 1:32, 9(12.0%) in 1:64, 7(9.4%) in 1:128, 3(3.40%) in 1:256, 1(1.3%) in 512 and 1(1.3%) in 1:2,048 respectively. 4. Positive rates of toxoplasma antibodies in cattls sera from each area were 0.2∼22.0%.

  • PDF

Helicobacter pylori 특이 계란항체의 생산 및 특성

  • Kim, Byoun-Jae;Kang, Byung-Hwa;Kim, Tae-Yong;Kim, Tae-Han;Kim, Kee-Won
    • Microbiology and Biotechnology Letters
    • /
    • v.25 no.6
    • /
    • pp.612-616
    • /
    • 1997
  • IgY (egg yolk immunoglobulin) against Helicobacter pylori was produced by immunizing hen with some Helicobacter pylori antigens. H. pylori whole cell, whole cell lysates, partially purified urease and p54 protein, which showed high antigenicity in mice, were used as immunogens. Four hens were immunized with these immunogens three times. IgY was purified from immunized egg yolk with polyethylene glycol (M.W. 8000) and its anti-H. pylori titer was determined by enzyme linked immunosorbent assay (ELISA). The anti-H. pylori titer reached peak at 8 weeks and was maintained over 20 weeks. H. pylori cells were agglutinated with these purified IgY and the specificity of these purified IgY was detected with immunoblotting.

  • PDF

Toxoplasma antibody titers by ELISA and indirect latex agglutination test in pregnant women (ELISA 및 간접 latex 응집반응검사에 의한 임산부의 항 톡소포자충 항체가)

  • 류재숙;민득영
    • Parasites, Hosts and Diseases
    • /
    • v.34 no.4
    • /
    • pp.233-238
    • /
    • 1996
  • The seroepidemiologic studies on antral-ToxopIasma antibody titers were carried out using ELISA and indirect latex agglutination test. Among 899 sera prepared from pregnant women, 39 cases (4.3%) revealed positive reaction and 218 sera from middle school students showed 4 positive reaction (1.8%) by ELISA. By LAT (newly established by National Veterinary Research Institute, Korea), the sera of 7 pregnant women (0.8%) showed positive reaction. When 80 sera showing ≥ 1 :8 by LAT were used for comparing the results obtained from LAT and Toxotest-MT (Eikon Chemical Co., Japans, 7 cases and 8 sera were positive, respectively. All of 11 sera of proven toxoplasmosis patients showed positive reaction in both tests. Overall proportion of agreement between LAT kit and Toxotest-MT was 0.94 (K-index : 0.632, p < 0.01), and LAT was considered to be useful for the screening of toxoplasmosis.

  • PDF

Enzyme-linked immunosorbent assay for detection of bovine antibody to Brucella abortus (축우 부루셀라병의 ELISA 진단법에 관한 연구)

  • Lim, Yoon-kyu;Lee, Doo-sick;Park, Jun-hong;Yang, Ki-chun;Kim, Seung-ho;Kim, Kong-sick;Hyun, Kwan-jong;Kim, Woo-tack;Lee, Yong-soon
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.1
    • /
    • pp.131-135
    • /
    • 1993
  • Enzyme-linked Immuno sorbent Assay (ELISA) for the serological diagnosis of Brucella abortus was developed and compared with plate agglutination test. Cell wall antigen was extracted from Brucella abortus 1119-3 by sonication and with a sodium deoxychlate solution. Optimum protein concentration of coating antigen were $0.4{\mu}g/100{\mu}{\ell}$ protein on each microtiter plate well. Horse radish peroxidase (HRP) labeled protein-G was used as a tracer of reacted antibodies. ELISA confirmed the agreeable results of 40 cases out of 43 cases by plate aggulutination test. ELISA diagnosed positive cases(10 out of 12) and negative cases (1 out of 12) with dubious sera by plate agglutination test. From this results ELISA could be used for the early diagnostic tools of Brucellosis in cattle.

  • PDF

Survey on the Distrributions of Swine Toxoplasma Antibodies by Latex Agglutination Test in Gyeongnam Central Area (경남 중부지역에서의 Latex응집반응을 이용한 돼지 톡스플라즈마병 항체분포 조사)

  • 이병훈;황보훈;변유성;이순선;김차용;서명득
    • Korean Journal of Veterinary Service
    • /
    • v.15 no.2
    • /
    • pp.174-183
    • /
    • 1992
  • This study was conducted to determine the serum antibodies against toxoplasma in swine from breeding-pig farm, pig farm and abattoir by latex agglutination(LA) test. LA test was carried out with commercial Toxo-MT kit (Eiken chemical co.). The results obtained were summerized as follows : 1. The cut-off titer of positive and negative reactions by Toxo-MT antigen used in this experiment was determined as the serum dilution of 1 ; 32. 2. positive rates of toxoplasma antibodies in 823 swine sera were 17.0%(140 cases) by LA test. 3. The toxoplasma antibody detection rates against 194 swine sera in breeding-pig farm, 273 swine sera in pig farm and 356 swine in abattoir were 46.9%(91 cases), 8.4%(23 cases) and 7.3% (26 cases) , respectively. 4. In LA test serum antibody titers in 823 test sera were shown as 51 cases (36.4%) in 1 : 32, 40(28.6%) in 1;64, 17(12.1%) in 1:128, 14(10.0%) in 1:256, 10(7.1%) in 1:512, 5(3.6%) in 1:1,024, and 3(2.1%) in 1 : 2,048. 5. Positive rates of toxoplasma antibodies in swine sera from each breeding-pig farm were 20.0∼61.9%.

  • PDF

Prevalence of toxoplasma antibody in swine by microplate latex agglutination test in Kyeongnam district (Latex 응집반응에 의한 경남중부지역 돼지의 톡소플라즈마병 항체조사)

  • Lee, Byung-hoon;Kim, Cha-yong;Suh, Myung-deuk
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.2
    • /
    • pp.263-268
    • /
    • 1993
  • This study was conducted to detect the serum antibody of toxoplasma in swine from breeding-pig, rearing-pig farm and slaughtered pig in abattior by latex agglutination(LA) test. The perfomance of LA test was carried out with commercial Toxo-MT kit(Eiken Chemical Co.)by Tsubota and Ozawa's method. The cut-off titer of positive and negative reactions by Toxo-MT antigen used in this experiment was determined as the serum titer of 1 : 32. Positive rate of toxoplasma antibody from the total of 823 serum samples by LA test was 17.0%(140 cases). And positive rates of toxoplasma antibody against serum samples of 194 from breeding-pig farm, 273 from rearing-pig farm and 356 from abattior were 91 cases(46. 9%), 23 cases(8.4%) and 26 cases(7.3%), respectively. The distributions of serum antibody titers in 823 test sera by LA test were shown 51 cases(36.3%) in 1:32, 40(28.6%) in 1:64, 17(12.1%) in 1:128, 14(10.0%) in 1:256, 3(2.1%) in 1:512, 5(3.6%) in 1:1024 and 3(2.1%) in 1:2048. The ranges of positive rate from the sera in each group of breeding-pig farms were 20~61.9%.

  • PDF

Serodiagnosis of canine toxoplasmosis by latex agglutination and indirect fluorescent antibody test (Latex 응집반응과 간접형광항체법을 이용한 개 톡소플라즈마병의 혈청학적 진단)

  • Lee, Byung-hoon;Lee, Eung-goo;Suh, Myung-deuk
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.4
    • /
    • pp.641-647
    • /
    • 1992
  • This study was conducted to determine the serum antibodies against toxoplasma in the artificially infected dogs, pet and street dogs by latex agglutination (LA) and indirect fluorescent antibody (IFA) test. LA test was carried out with commercial Toxo-MT kit (Eiken chemical Co.) and IFA test was carried out with rabbit-anti-dog IgG labelled with FITC (Cappel Co.) and toxo-antigen slides prepared in laboratory. The results obtained were as follows ; 1. Antibodies to Toxoplasma gondii in the artificially infected dogs were detected firstly at the Day 8 in IFA and Day 9 in LA test after inoculation. Positive antibody reactions by these tests were declined gradually afterward but maintained up to 12 weeks. 2. In LA test serum antibody titers in 310 test sera were shown as 10 cases(32%) in 1 : 32.5(1.0%) in 1 : 64, 4(1.3%) in 1 : 128 and 2(0.7%) in 1 : 256. In IFA test serum antibody titers 310 test sera were shown as 17 cases(5.5%) in 1 : 64, 8(2.6%) in 1 : 128 and 5(1.6%) in 1 : 256. 3. In the total of 310 sera from pet and street dogs toxoplasma antibody positive rates were 21 cases (6.8%) by LA and 30 cases (9.7%) by IFA test and the positive detection rates between these two groups by LA and IFA test were not significant(p<0.05). 4. In the total of 115 sera from pet dogs toxoplasma antibody positive rates were 12 cases(10.4%) by LA and 15(13.0%) by IFA test. And in the 195 street dogs the positive rates were 9 cases(4.6%) by LA and 15(7.7%) by IFA test. Also, the positive detection rates between these two groups by LA and IFA test were not significant(p<0.05). 5. Agreement of reactivity between LA and IFA test for 310 sera was 91.3% in total of 283 cases consisting of 12 cases(3.9%) of both LA and IFA positive and 271 cases(87.4%) of LA and IFA negative. 6. LA test was almostly equivalent to the IFA test in producibility and proved to be a simple tool for the screening of toxoplasma antibody in laboratory.

  • PDF