• Title/Summary/Keyword: closed range

Search Result 631, Processing Time 0.033 seconds

A Study on the Development of Idler by Hot Closed-die Forging (열간 형단조에 의한 아이들러 개발에 대한 연구)

  • 정호승;조종래;박희천
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.199-203
    • /
    • 2003
  • Idler of excavator are large product with diameter 500 - 600 mm and parts of a power transmit device. The object of the paper is developed large products by hot closed-die forging. The forging process which is proposed from numerical analysis and various tests is developed a large products with good quality. To estimate the design process parameters such as working load, temperature and flash thickness so on, numerical analysis are used by DEFORM 2D. To obtain a flow stress data and optimal forging temperature is carried out hot compression and tensile test at a various temperature range. Developed product is tested mechanical properties of elongation, hardness and tensile strength so on. Test results are presented excellent mechanical properties.

  • PDF

Closed-loop fiber optic gyroscope using gated two-harmonic phase modulation (두 주파수 위상변조 및 게이트를 이용한 폐회로 광섬유 자이로스코프)

  • 오문수;정만호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.528-532
    • /
    • 1987
  • Closed-loop fiber-optic gyroscope with linear scale factor for a wide dynamic range is demonstrated using a gating process and two-harmonic phase modulation, of which the second harmonic is obtained by a frequency doubler. Also the effects of the second harmonic and duty cycle of gating signal on the linearity of scale factor are estimated theoretically and compared with the measured data. The experimental results show the best linearity of scale factor is about 0.5% within the rotation rate 90.deg./sec. The closed-loop fiber-optic gyroscope with gated two-harmonic phase modulation can be used in the application demanding less sensitive performance and modest scale factor linearity.

  • PDF

A Study on the Performance of the Boiling and Condensation Heat Transfer of Vertical Closed Two-Phase Thermosyphons with Low Integral-Fins (관 외벽에 낮은 핀을 가진 수직 열사이폰의 비등 및 응축열전달 성능에 관한 연구)

  • Cho, Dong-Hyun
    • Solar Energy
    • /
    • v.19 no.1
    • /
    • pp.9-17
    • /
    • 1999
  • An Experimental study on the boiling and condensation heat transfer performance of thermosyphons with low intergral-fins was performed to investigate its heat transfer characteristics. A plain thermo syphon having the same inner and outer diameter as the finned thermosyphons was also tested for comparison. Water and CFC-30 was used as working fluids. The experimental results have been assessed and compared with same existing theories. Good agreement with the theories of Imura and Nusselt was obtained. The vertical closed-type thermosyphons with low integral-fins gave significant increases in the overall heat transfer coefficient compared to plain thermosyphon. In addition, the overall heat transfer coefficients and the operating characteristics was obtained as a function vof operating temperature for the practical applications. Also, the closed two-phase thermosyphons with low integral-fins would be highly recommended to achieve some inexpensive and compact heat exchangers in the range of low temperatures.

  • PDF

The P/PI Mode Switching Method of Gopinath Flux Observer for Sensorless Vector Control of Induction Motors (유도전동기 센서리스 벡터제어를 위한 고피나스 자속관측기의 P/PI 모드 전환)

  • Kang, Myeong-Kyu;Choi, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1732-1739
    • /
    • 2017
  • This paper presents a sensorless vector control algorithm of closed loop Gopinath flux observer to enhance the robustness at low speed by switching P/PI mode. Closed loop Gopinath flux observer has the problem in sensorless vector control of induction motor at low speed. This paper solves the problem using the characteristic function of closed loop Gopinath flux observer. P mode shows better performance than PI mode under the cut-off frequency of observer. But P mode always has a flux error due to DC offset, so this paper combines P mode and PI mode. This algorithm shows good performance over wide speed range. The performance has been confirmed through computer simulations using MATLAB SIMULINK and experiments.

Distribution of Stream Incision Rates in the Northern Part of the Taebaek Mountains (태백 산지 북부의 하천 하각률 분포)

  • Lee, Gwang-Ryul
    • Journal of The Geomorphological Association of Korea
    • /
    • v.25 no.4
    • /
    • pp.1-19
    • /
    • 2018
  • This study tries to identify distributional characteristics of stream incision rates at 23 points in the northern part of the Taebaek Mountains. Soyang-gang, Naerin-cheon, Odae-cheon, Dong-gang and upper reaches of Okdong-cheon Rivers closed to the Range show higher incision rates and the rates clearly decrease with distance from the Range. Therefore, the incision process in the northern part of the Range has been greatly influenced by uplift around the Range, and the Sobaek Mountain Range seem to play a role in the incision process. Limestone areas show lower incision rates due to degradation of terrace surface by dissolution. This study suggests that local hydrological, geological and geomorphological conditions can be regarded as an important factor in stream incision rates, although stream incision rates are greatly influenced by regional uplift.

Process Design for Manufacturing 1.5wt%C Ultrahigh Carbon Workroll: Void Closure Behavior and Bonding Strength (1.5wt%C 초고탄소 워크롤 제조를 위한 단조 공정 설계: 기공압착 및 접합강도 분석)

  • Lim, H.C.;Lee, H.;Kim, B.M.;Kang, S.H.
    • Transactions of Materials Processing
    • /
    • v.22 no.5
    • /
    • pp.269-274
    • /
    • 2013
  • Experiments and numerical simulations of the incremental upsetting test were carried out to investigate void closure behavior and mechanical characteristic of a 1.5wt%C ultra-high carbon steel. The experimental results showed that the voids become quickly smaller as the reduction ratio increases. The simulation results confirmed this behavior and indicated that the voids were completely closed at a reduction ratio of about 40~45% during incremental upsetting. After the completion of the incremental upsetting tests, the process of diffusion bonding was employed to heal the closed voids in the deformed specimens. To check the appropriate temperature for diffusion bonding, deformed specimens were kept at 800, 900, 1000 and $1100^{\circ}C$ for an hour. In order to investigate the effect of holding time for diffusion bonding at $1100^{\circ}C$, specimens were kept at 10, 20, 30, 40, 50 and 60minutes in the furnace. A distinction between closed and healed voids was clearly established using microstructural observations. In addition, subsequent tensile tests demonstrated that complete healing of a closed void was achieved for diffusion bonding temperatures in the range $900{\sim}1100^{\circ}C$ with a holding time larger than 1 hour.

A Study on Closed-Loop Control of a Stepping Motor for Resonance Elimination (공진배제를 위한 스템핑 모터의 폐회로제어에 관한 연구)

  • 노상현;김교형
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.90-97
    • /
    • 1991
  • A stepping motor can be driven with open-loop or closed-loop control. The major disadvantage of open-loop control is that it is subjected to resonance and instability in certain speed range, and that there is no way to check stalling or error in position. In this paper, a closed-loop control system consisting of a microcomputer, a hybrid stepping motor, a drive, a lead screw, and an encoder which is used as a position sensor is developed. A control program is programmed in assembly language for real time control and the versatile interface adapter(VIA) is used as the interface with the microcomputer. The experimental results of the stepping motor were eliminated on all kinds of inertia load, and maximum start stop pulse rate and maximum slewing pulse rate were also increased about twice respectively.

A Fuzzy-based Fusion Wireless Localization Method (퍼지기반 융합 무선위치추정기법)

  • Cho, Seong-Yun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.4
    • /
    • pp.507-512
    • /
    • 2015
  • In the wireless localization systems using range measurements, iteration method-based approximated solutions have been used. Also, linear closed-form solutions have been investigated in the light of local minimum problem and computational load. However, each closed-form solution has individual error factors that cause usage limit of the solutions. In this paper, a fusion method integrating two representative closed-form solutions is presented. The presented method cancels the error factors of each solution out. Weights for integrating the standalone solutions are determined using the error factors-based fuzzy method. The performance of the proposed method is verified using some simulation results.

A Study on the Mandibular Movements in the Patients with TMJ Lock Closed (악관절 폐구성 과두걸림 환자의 하악운동에 관한 연구)

  • Ji-Won Lee;Sung-Chang Chung
    • Journal of Oral Medicine and Pain
    • /
    • v.15 no.1
    • /
    • pp.79-89
    • /
    • 1991
  • The author examined the patterns and various ranges of mandibular movements in TMJ lock closed patients in the frontal, sagittal and horizontal plane and obtained the following results. 1. In the frontal trajectory, the mean amount of maximum mouth opening was 24.4mm and the opening paths were deviated to the affected side in 87.1% of the patients. The mean amount of maximum laterotrusion to the affected side was 10.4mm and that of non-affected side was 7.5mm. There was a significant difference between them(p<0.001). 2. In the sagittal trajectory, the mean amount of the maximum protrusion was 7.0mm, the mean amount of the maximal retrusion was 1.0mm 3. In the horizontal trajectory, the pattern of laterotrusion showed asymmetry: the mean length of non-affected side was smaller than that of the affected side. Protrusive path were deviated to the affected side in 64.5% of the patients, the mean degree of deviation was 16.4$^{\circ}$. The mandibular movements of TMJ lock-closed patients can be characterized by decreased range of mouth opening, protrusive movement, and laterotrusive movement to the non-affected side and also characterized by deviated opening and protrusive path to the affected side.

  • PDF

Comparison of mortality between open and closed pelvic bone fractures in Korea using 1:2 propensity score matching: a single-center retrospective study

  • Jaeri Yoo;Donghwan Choi;Byung Hee Kang
    • Journal of Trauma and Injury
    • /
    • v.37 no.1
    • /
    • pp.6-12
    • /
    • 2024
  • Purpose: Open pelvic bone fractures are relatively rare and are considered more severe than closed fractures. This study aimed to compare the clinical outcomes of open and closed severe pelvic bone fractures. Methods: Patients with severe pelvic bone fractures (pelvic Abbreviated Injury Scale score, ≥4) admitted at a single level I trauma center between 2016 and 2020 were retrospectively analyzed. Patients aged <16 years and those with incomplete medical records were excluded from the study. The patients were divided into open and closed fracture groups, and their demographics, treatment, and clinical outcomes were compared before and after 1:2 propensity score matching. Results: Of the 321 patients, 24 were in the open fracture group and 297 were in the closed fracture group. The open fracture group had more infections (37.5% vs. 5.7%, P<0.001) and longer stays in the intensive care unit (median 11 days, interquartile range [IQR] 6-30 days vs. median 5 days, IQR 2-13 days; P=0.005), but mortality did not show a statistically significant difference (20.8% vs. 15.5%, P=0.559) before matching. After 1:2 propensity score matching, the infection rate was significantly higher in the open fracture group (37.5% vs. 6.3%, P=0.002), whereas the length of intensive care unit stay (median 11 days, IQR 6-30 days vs. median 8 days, IQR 4-19 days; P=0.312) and mortality (20.8% vs. 27.1%, P=0.564) were not significantly different. Conclusions: The open pelvic fracture group had more infections than the closed pelvic fracture group, but mortality was not significantly different. Aggressive treatment of pelvic bone fractures is important regardless of the fracture type, and efforts to reduce infection are important in open pelvic bone fractures.