• Title/Summary/Keyword: closed eye

Search Result 111, Processing Time 0.027 seconds

Multi-Valued Decision Making for Transitional Stochastic Event: Determination of Sleep Stages through EEG Record

  • Nakamura, Masatoshi;Sugi, Takenaop;Morota, Yukinao;Tachibana, Naoko;Shibasaki, Hiroshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.493-493
    • /
    • 2000
  • Multi-valued decision making for transitional stochastic events was newly derived based on conditional probability of database. The two values (on-off) decision making method without transition had been proposed by one of the author in a previous work for a purpose of realizing human on-off decision making. The current method is an extension of the previous on-off decision making. By combining the conditional probability and the transitional probability, the closed form of the algorithm for the multi-valued transitional decision making was derived. The proposed multi-valued decision making was successfully applied to the determination of the five levels of the vigilance of a subject during the EEG recording; awake stage, drowsy stage and sleeping stages (stage 1, stage 2/3, REM (rapid eye movement)). The method for determining the vigilance level can be directly usable for the two purposes; selection of awake EEG segments for automatic EEG interpretation, and determination of sleep stages through sleep EEG. The proposed multi-valued decision making with a mathematical background of the probability can be applicable widely, in industries and in medical fields for purposes of the multi-valued decision making.

  • PDF

Electron Microscopical Observation on the Compound Eye in Meimuna mongolica D. (쓰름매미 (Meimuna mongolica D.) 복안의 전자현미경적 관찰)

  • Choi, Choon-Keun;You, Kwan-Hee;Shin, Kil-Sang;Choe, Rim-Soon
    • Applied Microscopy
    • /
    • v.9 no.1
    • /
    • pp.1-11
    • /
    • 1979
  • Electron microscopic studies were carried out to investigate the fine structure of ommatidia of the compound eyes in Meimuna mongolica D. The crystalline cone appears round, and is composed of four double-membraned cone cells and surrounded by pigment cells having many pigment granules. The rhabdom is a closed type, and is composed of four rhabdomeres Its cross section reveals lamellated microvilli which are oriented in four different directions suggesting that these represent four photoreceptive sites. The microvilli, in a cross sectional view, are hexagonal in shape with a central axis inside. There are usually eight retinular cells arranged radially from the rhabdom, but in some retinular layers seven or nine retinular cells could be observed. The cytoplasm of each retinular cell is interconnected with that of microvilli of the rhabdomere, but the appearance of this interconnection varies depending on the number of retinular cells.'The retinlilar cells neighboring the microvilli seem to have well-developed perirhabdomal vacuoles and mitochondria as well as pigment granules surrounding these vacuoles.

  • PDF

Comparison of Accuracy for Autorefraction according to Measuring methods (측정방식에 따른 자동굴절검사의 정확도 비교)

  • Jeong, Youn Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.353-359
    • /
    • 2018
  • In this study, the performance between subjective refraction and open-field/closed view autorefraction was estimated. We measured the refractive error of early adults aged 18 to 20 years who did not have eye disease. The differences between measurements obtained by subjective refraction and open-field autorefraction for SE, J0, and J45 were $-0.13{\pm}0.53D$ (p=0.17), $+0.33{\pm}0.68D$ (p=0.01), and $+0.13{\pm}0.68D$ (p=0.26), respectively, with only J0 differing significantly. The differences between the measurements of subjective refraction and closed-view autorefraction for SE, J0, and J45 were $-0.30{\pm}0.42D$ (p=0.00), $+0.30{\pm}0.71D$ (p=0.02), and $-0.02{\pm}0.63D$ (p=0.88), respectively, with only SE and J0 differing significantly. The coefficient of accuracy for SE, J0, and J45 components of open-field and closed-view autorefraction were 1.04, 1.33, and 1.34 and 0.83, 1.40, and 1.24, respectively. It is possible to predict the refractive error, which is necessary when deciding on subjective refraction, by measuring the objective refraction of open-field/closed view autorefractors.

Staticposture stability evaluation of female elderly using stability evaluation device (균형능력 평가 장치를 이용한 여성노인의 정적자세안정성 평가)

  • Kim, Tae-Hyung;Yi, Jae-Hoon;Oh, Seong-Geun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5518-5524
    • /
    • 2011
  • The purpose of this study is to investigate the change of balance ability on aging by measuring balance ability of elderly females whose age is over 65. The subjects are ten elderly women (the mean age: 71.9) able to walk without assistants, the assistant equipments and drug dependence and ten young healthy women (the mean age: 23.2). We measured stability index (ST), Fourier index (F), weight distribution (WD), weight distribution index (WDI), synchronization index (SI) and fall index (FI) by using Tetrax (Tetra-ataxiometric Posturography). In result, STs and Fs at the low frequency region (F1) represented the significant difference between two groups at all postures with PO (pillow with eye open) exception (p<.01). Fs at the other frequency regions (F2~F8) represented the significant difference between two groups (p<.05). WDI of the elderly women represented the higher values than the young women at all postures but there are the significant difference at PO and PC (pillow with eye closed) only. These results may be due to age-related ability decline of somatesthesia, vestibular organ, central nervous system.

Self-Adaptive Performance Improvement of Novel SDD Equalization Using Sigmoid Estimate and Threshold Decision-Weighted Error (시그모이드 추정과 임계 판정 가중 오차를 사용한 새로운 SDD 등화의 자기적응 성능 개선)

  • Oh, Kil Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.17-22
    • /
    • 2016
  • For the self-adaptive equalization of higher-order QAM systems, this paper proposes a new soft decision-directed (SDD) algorithm that opens the eye patterns quickly as well as significantly reducing the error level in the steady-state when it is applied to the initial equalization stage with completely closed eye patterns. The proposed method for M-QAM application minimized the computational complexity of the existing SDD by the symbol estimated based on the two symbols closest to the observation, and greatly simplified the soft decision independently of the QAM order. Furthermore, in the symbol estimating it increased the reliability of the estimates by applying the superior properties of the sigmoid function and avoiding the erroneous estimation of the threshold function. In addition, the initialization performance was improved when an error is generated to update the equalizer, weighting the symbol decision by the threshold function to the error, resulting in an extension of the range of error fluctuations. As a result, the proposed method improves remarkably the computational complexity and the properties of initialization and convergence of the traditional SDD. Through simulations for 64-QAM and 256-QAM under multipath channel conditions with additive noise, the usefulness of the proposed methods was confirmed by comparing the performance of the proposed 2-SDD and two forms of weighted 2-SDD with CMA.

The Effect of 12-weeks Aquatic Exercise on Dynamic Balance and Pain Factors in Elderly Osteoarthritis Patients (12주간의 수중운동이 노인 골관절염 환자의 동적평형성과 통증요인에 미치는 영향)

  • Im, Sun-Young;Eo, Su-Ju;Kim, Song-June;Hur, Sung-Hoon;An, Kyung-Jun;Lee, Jang-Kyu;Lee, Jong-Sam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.601-609
    • /
    • 2016
  • This study evaluated the dynamic balance and pain after 12 weeks aquatic exercise in old osteoarthritis patients. The dynamic balances were assessed using 2 different experimental conditions (Open Eye Condition; OEC, Closed Eye Condition; CEC). Twenty-two subjects were assigned one of the two experimental groups: arthritis group (ART, age=$65.25{\pm}5.9$, n=11), control group(CON, age=$64.50{\pm}7$, n=11). All subjects participated in the aquatic exercise program three times a week for 12 weeks. The dynamic balances (OEC (p<.001), CEC (p<.05)) capability were improved significantly in the ART group after 12 week aquatic exercise. Visual Analogue Scale (VAS) was decreased significantly [Factor 10(Soft chair, p<0.01), 11 (Lying down, p<0.05), 12(Handicap, p<0.05), 13 (Work interference, p<0.01)] in the ART group. In conclusion, aquatic exercise was effective in improving the overall health status and the capacity of dynamic balances and reducing the degree of pain in osteoarthritis patients.

The Effects of Fatigue Induced by Submaximal Treadmill Exercise on Body Sway (최대하 트레드밀 운동에 의한 피로가 신체 동요에 미치는 영향)

  • Lee, Mi-Sun;Yi, Chung-Hwi;Cho, Sang-Hyun;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.7 no.2
    • /
    • pp.35-54
    • /
    • 2000
  • The purposes of this study were to assess variation of body sway prior to and after submaximal treadmill exercise; to determine the time course of the effects of a fatiguing performed on a treadmill on body sway; and to compare position sense prior to and after exercise in order to assess any variance in proprioception caused by submaximal treadmill exercise. The subjects were twenty-four healthy men in their twenties. They stood barefoot on the Kinesthetic Ability Training Balance Platform to measure body sway. Control trials were performed with eyes alternately open and closed. In the eyes open condition, they were asked to look at a target placed at eye level 1 m in front them. A total of 10 trials, each lasting 20 seconds, were performed. After this series of trials, position sense was measured. Subjects then exercised on the treadmill until 85% of each person's maximal heart rate was reached. The first series of postural sway measurements began immediately after this exercise. The second identical series of postural sway trials was performed at approximately 10 minutes after exercise. The third series was performed approximately 20 minutes after exercise. This allowed approximately 5 minutes of rest between each experimental series. Position sense was measured at approximately 15 and 25 minutes after exercise. The results were as follows: 1) There was a significant increase in body sway after submaximal treadmill exercise compared to pre-exercise values under both visual conditions (p<.05). 2) After submaximal treadmill exercise, under the eyes open condition, the mean value of body sway was significantly increased after both the first and second series (p<.05). Under the eyes closed condition, the mean value of body sway increased significantly after the first series but decreased significantly after the third series (p<.05). 3) Position sense, measured repeatedly after submaximal treadmill exercise, did not change significantly with respect to pre-exercise values (p>.05). These results suggest that fatigue induced by submaximal treadmill exercise produced an increase in body sway in young healthy subjects with or without visual input, but the increase appeared to be lasting less than 15 minutes. No significant change in position sense suggested that proprioception was unaffected by submaximal treadmill exercise-induced fatigue.

  • PDF

Application of Chaotic Analysis to Electroencephalography : Preliminary Study (혼돈 이론을 이용한 뇌파 분석에 대한 기초 연구)

  • Park, Hae Jeong;Park, Kwang Suk;Kwon, Jun Soo
    • Korean Journal of Biological Psychiatry
    • /
    • v.2 no.2
    • /
    • pp.257-265
    • /
    • 1995
  • The object of this study is to apply a chaotic signal analysis method to the EEG research, especially in the aspect of neuropsychiatry, and to get some inspection of the chaotic phenomena according to the brain sites and subjects. We have acquired 21 channel EEG data and one EOG according to the international 10-20 system and calculated the correlation dimension. The subject groups are schizophrenics, bipolar disorder, major depression and normal control. They were all awoke and eye-closed. We have found no distinctive features from our experiments except temporal regions have slightly higher correlation dimension. There is also no specific distinctions between groups. We conjecture that these results are mainly because the subjects were not well controlled. EEG dimension may change in accordance with to the age, sex, medication and the time data were selected to calculate. We have also considered some conditions for a better and more objective research of chaotic analysis to EEG research. Better conditioning and standardizing the calculation of correlation dimension is necessary for the application of the chaotic analysis to neuropsychiatry.

  • PDF

Availability of Functional Reach Test for Balance Evaluation of the Elderly Through Sensory Organization Test (감각 조직화 검사를 통한 노인의 균형평가를 위한 기능적 뻗기 검사의 유용성)

  • Kim, Yong-Wook;Choi, Houng-Sik;Kim, Tae-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.3
    • /
    • pp.293-301
    • /
    • 2011
  • Purpose : The purposes of this study were to investigate the age-related difference in balance ability in the elderly over 65 years and to verify the clinical usefulness of the functional reach test (FRT) for balance evaluation of the elderly through the sensory organization test (SOT). Methods : The subjects were forty-six community dwelling elderly people over 65 years old in order to verify the correlation of balance measures and to compare the balance ability. Balance was measured using the FRT and the six sub-equilibrium scores and the composite equilibrium score of the SOT. Pearson's product correlation coefficient was used to evaluate the relationships among these measurements of balance. Results : There was a significant difference in functional reach by age in the elderly (p<.01). There was a significant negative correlation between the FRT and the age of the elderly (r=-.396, p<.01). There was also significant high positive correlation between the FRT and the eye closed sway surface (EC/SS) (r=.789, p<.01), and composite equilibrium score (r=.548, p<.01) of the SOT. Conclusion : Thus, it is possible to use the FRT as a quantitative measure of balance, rather than the SOT, which is more expensive and complicated to evaluate elderly people. According to the results of this study, the use of the FRT is required clinically to objectively measure the balance of elderly people in the future.

Feasibility Study of EEG-based Real-time Brain Activation Monitoring System (뇌파 기반 실시간 뇌활동 모니터링 시스템의 타당성 조사)

  • Chae, Hui-Je;Im, Chang-Hwan;Lee, Seung-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.258-264
    • /
    • 2007
  • Spatiotemporal changes of brain rhythmic activity at a certain frequency have been usually monitored in real time using scalp potential maps of multi-channel electroencephalography(EEG) or magnetic field maps of magnetoencephalography(MEG). In the present study, we investigate if it is possible to implement a real-time brain activity monitoring system which can monitor spatiotemporal changes of cortical rhythmic activity on a subject's cortical surface, neither on a sensor plane nor on a standard brain model, with a high temporal resolution. In the suggested system, a frequency domain inverse operator is preliminarily constructed, considering the individual subject's anatomical information, noise level, and sensor configurations. Spectral current power at each cortical vertex is then calculated for the Fourier transforms of successive sections of continuous data, when a single frequency or particular frequency band is given. An offline study which perfectly simulated the suggested system demonstrates that cortical rhythmic source changes can be monitored at the cortical level with a maximal delay time of about 200 ms, when 18 channel EEG data are analyzed under Pentium4 3.4GHz environment. Two sets of artifact-free, eye closed, resting EEG data acquired from a dementia patient and a normal male subject were used to show the feasibility of the suggested system. Factors influencing the computational delay are investigated and possible applications of the system are discussed as well.