• 제목/요약/키워드: close-form solution

검색결과 40건 처리시간 0.02초

Effect of Cellulose Concentration of Cellulose/[AMIM]Cl Solution on the Liquid Crystalline Spinning

  • Kim, Su-Jin;Jang, Jin-Ho
    • 한국염색가공학회:학술대회논문집
    • /
    • 한국염색가공학회 2012년도 제46차 학술발표회
    • /
    • pp.51-51
    • /
    • 2012
  • Cellulose is extremely difficult to dissolve cellulose in water and most common organic solvents due to their stiff molecular structure, close chain packing and intermolecular hydrogen bonds. Recently, cellulose solutions using ionic liquids (ILs) as a green solvent have been known to form cholesteric liquid crystalline phase at high cellulose concentration. In this study, the phase transition and rheological behaviors of concentrated cellulose/[AMIM]Cl solution were investigated using polarized optical microscopy and rheometry. Studies were conducted to characterize the influence of cellulose concentration on the phase transition of the cellulose solution and the mechanical properties of the regenerated fibers spun from the anisotropic cellulose/[AMIM]Cl solutions.

  • PDF

원동광산의 철광석에 수반되는 콘드로다이트에 대한 광물학적 연구 (Mineralogical Study of Chondrodite in Iron Ores from the Wondong Mine, Korea)

  • 김수진;노진화;이영락
    • 한국광물학회지
    • /
    • 제1권1호
    • /
    • pp.63-69
    • /
    • 1988
  • Chondrodite form the Wondong mine, Korea, which is the first occurrence from the southern Korea, has been studied for its mineralogical characterization. It occurs in close association with penninite, phlogopite, diopside and garnet within the magnetite ore bodies, which are debeloped along the contact of the Hwajeol Formation and rhyolite. Two kinds of chondrodites are recognized by their different optical properties; the high birefringent untwinned one and the low birefringent twinned one. The former has slightly higher Mn content than the latter. Twinning in chondrodite has been formed in close relation to substitution Mg (Fe, Mn) in the humite solid solution, as evidenced by the chemical variation across the twin lamallae.

  • PDF

Cyclic behavior of steel beam-concrete wall connections with embedded steel columns (II): Theoretical study

  • Li, Guo-Qiang;Gu, Fulin;Jiang, Jian;Sun, Feifei
    • Steel and Composite Structures
    • /
    • 제23권4호
    • /
    • pp.409-420
    • /
    • 2017
  • This paper theoretically studies the cyclic behavior of hybrid connections between steel coupling beams and concrete shear walls with embedded steel columns. Finite element models of connections with long and short embedded steel columns are built in ABAQUS and validated against the test results in the companion paper. Parametric studies are carried out using the validated FE model to determine the key influencing factors on the load-bearing capacity of connections. A close-form solution of the load-bearing capacity of connections is proposed by considering the contributions from the compressive strength of concrete at the interface between the embedded beam and concrete, shear yielding of column web in the tensile region, and shear capacity of column web and concrete in joint zone. The results show that the bond slip between embedded steel members and concrete should be considered which can be simulated by defining contact boundary conditions. It is found that the loadbearing capacity of connections strongly depends on the section height, flange width and web thickness of the embedded column. The accuracy of the proposed calculation method is validated against test results and also verified against FE results (with differences within 10%). It is recommended that embedded steel columns should be placed along the entire height of shear walls to facilitate construction and enhance the ductility. The thickness and section height of embedded columns should be increased to enhance the load-bearing capacity of connections. The stirrups in the joint zone should be strengthened and embedded columns with very small section height should be avoided.

Optimal ρ acceleration parameter for the ADI iteration for the real three dimensional Helmholtz equation with nonnegative ω

  • Ma, Sangback
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제3권2호
    • /
    • pp.1-4
    • /
    • 1999
  • The Helmholtz equation is very important in physics and engineering. However, solution of the Helmholtz equation is in general known as a very difficult phenomenon. For if the ${\omega}$ is negative, the FDM discretized linear system becomes indefinite, whose solution by iterative method requires a very clever preconditioner. In this paper we assume that ${\omega}$ is nonnegative, and determine the optimal ${\rho}$ parameter for the three dimensional ADI iteration for the Helmholtz equation. The ADI(Alternating Direction Implicit) method is also getting new attentions due to the fact that it is very suitable to the vector/parallel computers, for example, as a preconditioner to the Krylov subspace methods. However, classical ADI was developed for two dimensions, and for three dimensions it is known that its convergence behaviour is quite different from that in two dimensions. So far, in three dimensions the so-called Douglas-Rachford form of ADI was developed. It is known to converge for a relatively wide range of ${\rho}$ values but its convergence is very slow. In this paper we determine the necessary conditions of the ${\rho}$ parameter for the convergence and optimal ${\rho}$ for the three dimensional ADI iteration of the Peaceman-Rachford form for the real Helmholtz equation with nonnegative ${\omega}$. Also, we conducted some experiments which is in close agreement with our theory. This straightforward extension of Peaceman-rachford ADI into three dimensions will be useful as an iterative solver itself or as a preconditioner to the the Krylov subspace methods, such as CG(Conjugate Gradient) method or GMRES(m).

  • PDF

Study of New Control Method for Linear Periodic System

  • Jo, Janghyen
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1999년도 제14차 학술회의논문집
    • /
    • pp.83-87
    • /
    • 1999
  • The purpose of this study is to provide the new method for selection of a close to optimal scalar control of linear time-periodic system. The case of scalar control is considered, the gain matrix being assumed to be at worst periodic with the system period T. The form of gain matrix may have various kinds but must have same period, for example, one of each element being represented by Fourier series. As the optimal gain matrix I consider the matrix ensuring the minimum value of the larger real part of the Poincare exponents of the system. Finally we present a pole placement algorithm to make the given system be stable. It is possible to determine the stability of the given periodic system without get the analytic solution. The application of the method does not require the construction of the Floquet solution. At present state of determination of the gain matrix for this case will be done only by systematic numerical search procedures.

  • PDF

PVAm 적용이 백상지의 형광증백제 발현효율에 미치는 영향 (Effect of PVAm Application for Fine Paper on Effectiveness of Optical Brightening Agent)

  • 조병욱;원종명
    • 펄프종이기술
    • /
    • 제48권3호
    • /
    • pp.23-29
    • /
    • 2016
  • Effects of cationic polyvinylamine (PVAm) dry strength agent on effectiveness of optical brightening agent (OBA) during fine papermaking and the mechanism for brightness reduction of paper by PVAm was investigated by UV/Vis spectroscopy and turbidity measurement of OBA solution with PVAm. It was shown that PVAm reduced brightness of paper while opacity was not varied and tensile strength of paper was increased. Tetra-type OBA solution showed the peaks around the wavelength of 280 nm and 330 nm and the increase in the OBA concentration increased the UV absorbance in all wavelength. Addition of PVAm into the OBA solution decreased the UV absorbance at 280 nm. Turbidities of OBA and PVAm solutions were close to zero, respectively, while the turbidity value increased for the mixed solution of OBA and PVAm in various mixing ratios and the highest value was obtained when the mixing ratio of PVAm and OBA was 5:5, meaning that cationic PVAm formed complex with anionic OBA. In conclusion, cationic PVAm could form a complex with anionic OBA and that reduced UV absorbance, resulting in the reduced brightness of paper.

Nasal Absorption of Procyclidine in Rats and Dogs

  • Jang, Eun-Ju;Lee, Young-Joo;Chung, Suk-Jae;Shim, Chang-Koo
    • Archives of Pharmacal Research
    • /
    • 제24권3호
    • /
    • pp.219-223
    • /
    • 2001
  • Nasal absorption of procyclidine, a synthetic anticholinergic compound, was investigated in Wistar rats and Beagle dogs. The dosing solution was prepared by dissolving$^{14}C$-procyclidme in 50% ethanolic saline. The dosing solution was administered intravenously and intranasally to rats at a dose of 0.6 mg/kg (i.e., $60{\mu}$l/kg in the form of a 1% w/v solution), and intravenously, orally and intranasally to doss at a dose of 0.3 mg/kg(i.e., $6{mu}$l/kg in the form of a 5% w/v solution). Blood samples were taken from an artery of the animals through the catheter for periods of 1200 (for rats) and 1440 min (for dogs), and the radioactivity in the samples was determined by liquid scintillation counting. The nasal bioavailability of Procyclidine in rats and dogs, based on the radioactivity was calculated to be 81.1 and 98.6% respectively. In both rats and dogs, the plasma profiles of procyclidine following nasal administration were very close to those following intravenous administration, leading to nearly superimposable profiles between the two protocols. In dogs, nasal administration resulted in significantly higher plasma concentrations during the first 30 min period compared to oral administration, suggesting the superiority of the nasal route over the oral route in terms of a prompt expression of the pharmacological effect of the drug. The results obtained in this study indicate that procyclidine is rapidly and nearly completely absorbed via the nasal route. In conclusion, nasal administration represents a viable alternative to intravenous administration in the case of procyclidine.

  • PDF

Structural performance of fiber reinforced cementitious plinths in precast girder bridges

  • Gergess, Antoine N;Challita, Julie
    • Structural Engineering and Mechanics
    • /
    • 제82권3호
    • /
    • pp.313-323
    • /
    • 2022
  • Steel laminated elastomeric bearings are commonly used in bridge structures to control displacements and rotations and transfer forces from the superstructure to the substructure. Proper knowledge of design, fabrication and erection procedures is important to ensure stability and adequate structural performance during the lifetime of the bridge. Difference in elevations sometimes leads to large size gaps between the bearing and the girder which makes the grout thickness that is commonly used for leveling deviate beyond standards. This paper investigates the structural response of High Strength Fiber Reinforced Cementitious (HSFRC) thin plinths that are used to close gaps between bearing pads and precast girders. An experimental program was developed for this purpose where HSFRC plinths of different size were cast and tested under vertical loads that simulate bridge loading in service. The structural performance of the plinths was closely monitored during testing, mainly crack propagation, vertical reaction and displacement. Analytically, the HSFRC plinth was analyzed using the beam on elastic foundation theory as the supporting elastomeric bearing pads are highly compressible. Closed form solutions were derived for induced displacement and forces and comparisons were made between analytical and experimental results. Finally, recommendations were made to facilitate the practical use of HSFRC plinths in bridge construction based on its enhanced load carrying capacity in shear and flexure.

Modeling the electric transport of HCl and H3PO4 mixture through anion-exchange membranes

  • Koter, Stanislaw;Kultys, Monika;Gilewicz-Lukasik, Barbara
    • Membrane and Water Treatment
    • /
    • 제2권3호
    • /
    • pp.187-205
    • /
    • 2011
  • The electric transport of the mixture of hydrochloric and phosphoric acids through strong base (Neosepta ACM) and weak base (Selemion AAV) anion-exchange membranes was investigated. The instantaneous efficiency of HCl removal from the cathode solution, $CE_{Cl}$, with and without $H_3PO_4$ was determined. It was found that $CE_{Cl}$ was 0.8-0.9 if the number of moles of elementary charge passed through the system, $n_F$, did not exceed ca. 80% of the initial number of HCl moles in the cathode solution, $n_{Cl,ca,0}$. The retention efficiency of $H_3PO_4$ in that range was close to one. The transport of acid mixtures was satisfactorily described by a model based on the extended Nernst-Planck and Donnan equations for $n_F$ not exceeding $n_{Cl,ca,0}$. Among the tested model parameters, most important were: concentration of fixed charges, the porosity-tortuosity coefficient, and the partition coefficient of an undissociated form of $H_3PO_4$. For the both membranes, the obtained optimal values of fixed charge concentration, $\bar{c}_m$, were up to 40% lower than the literature values of $\bar{c}_m$ obtained from the equilibrium measurements. Regarding the $H_3PO_4$ equilibria, it was sufficient to consider $H_3PO_4$ as a monoprotic acid.

광원 방향에 대한 제한조건을 이용한 Photometric Stereo Calibration (Photometric Stereo Calibration using Constraint on Light Source Directions)

  • 정성철;;원상철
    • 대한임베디드공학회논문지
    • /
    • 제8권2호
    • /
    • pp.111-119
    • /
    • 2013
  • This paper proposes one method on photometric stereo calibration using the constraint on light source directions in which the light sources have the unknown tilt and slant angles but the slant angles are the same. First, the constraint is analyzed based on the equation of linear ambiguity which leads to the conclusion that another constraint should be added to solve the calibration completely. Later, the combination of constraint on light source directions and the constraint that there exists at least six surface patches having known albedos is exploited to resolve the linear ambiguity up to an accurate and close-form solution. The effective performance of the proposed method is demonstrated through experiment results.