• Title/Summary/Keyword: clinical test

Search Result 8,132, Processing Time 0.048 seconds

Comparison of the effect of removing artificial dental plaque depending on various interdental cleaning products on the interdental surface of zirconia crowns (치간 세정 용품에 따른 지르코니아 크라운 인접면의 인공 치면 세균막 제거 효과)

  • Kim, Hyun-Wook;Song, Ha-Kyung;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.291-298
    • /
    • 2021
  • Purpose. The purpose of this study is to compare five interdental cleansing products' effectiveness on removing artificial dental plaque on the interdental space of zirconia crowns. Materials and methods. A model with abutments on the right mandibular second premolar and first molar were prepared. 10 zirconia crowns for each abutment were fabricated. After applying artificial dental plaque between the zirconia crowns, a single clinician attempted to remove the plaque with five products: interdental toothbrush, end-tuft toothbrush, dental floss, Easypick, Water pik. They were conducted 10 times per group. The aspect and area of removed surfaces were analyzed using images taken with a digital camera. One factor analysis of variance was performed as a statistical analysis, and a post-hoc test was performed using the Scheffé method (P < .05). Results. There were differences in the area and the pattern according to the characteristics of the products. The largest area, including the marginal portion, was removed in the dental floss group. Interdental toothbrush group was the most effective in removing the dental plaque at the marginal portion. Easypick was less effective than the interdental toothbrush. The end-tuft toothbrush showed better results than other products in cleansing mesiobuccal and distobuccal area, but could not cleanse the area directly below the contact point. In Water pik group, artificial dental plaque was scarcely removed. The removal rate of artificial dental plaque was in the order of floss (69.47%), end-tuft toothbrush (49.36%), interdental toothbrush (44.20%), Easy pick (13.04%), and Water pik (0.59%). Conclusion. Dental floss showed the highest removal rate in the interdental space restored with zirconia crowns, while interdental toothbrush was the most effective in removing the dental plaque at the marginal portion.

Antibacterial Effect on Enterococcus Faecalis and Physical Properties of Chitosan Added Calcium Hydroxide Canal Filling Material (키토산 첨가 수산화칼슘 근관 충전재의 Enterococcus Faecalis에 대한 항균 효과 및 물리적 성질)

  • Song, Sol;Kim, Yu-Jin;Lee, Jung-Hwan;Lee, Joonhaeng;Shin, Jisun;Kim, Jongbin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.2
    • /
    • pp.198-208
    • /
    • 2021
  • The aim of this study was to evaluate the antibacterial effect on Enterococcus Faecalis and physical properties of chitosan added calcium hydroxide canal filling material. Low, medium, high molecular weights of chitosan powder were mixed with calcium hydroxide canal filling material. Also, for each molecular weight group, 1.0, 2.0, 5.0 wt% of chitosan powder were added. An overnight culture of E. faecalis was adjusted to 1 × 106 CFU/ml. For test of antibacterial effect, three different molecular weights of 2.0 wt% chitosan and three different concentrations of high molecular weight chitosan were mixed with calcium hydroxide canal filling material. The absorbance of plates was analyzed using spectrophotometer at 570 nm with a reference wavelength of 600 nm. Physical properties such as flow, film thickness and radiopacity were examined according to ISO 6876 : 2012. All molecular weight type of chitosan containing material showed inhibitory effect against E. faecalis growth compared to non-chitosan added calcium hydroxide canal filling material group (p < 0.05). High molecular weight chitosan containing material showed the most antibacterial effect. Also, the antibacterial effect decreased as the incorporated amount of chitosan decreased (p < 0.05). Every molecular weight group of material containing chitosan had a tendency for reduced flow and radiopacity, increased film thickness according to amount of chitosan. Low molecular weight of 1.0 wt% chitosan addition did not show any significant difference of physical properties compared to conventional calcium hydroxide canal filling material. In conclusion, for reinforcement of antibacterial effect against E. faecalis and for favorable physical properties, 2.0 wt% of chitosan adding is recommended. Considering its antibacterial effect of chitosan, further studies are required for clinical application of chitosan in endodontics and pediatric dentistry.

A Case of Hunter Syndrome Diagnosed at 7 Months of Age by Exome Sequencing (엑솜시퀀싱을 통해 생후 7개월에 진단된 헌터증후군)

  • Song, Ari;Lee, Jin Sung;Im, Minji;Park, Hyung Doo;Cho, Sung Yoon;Jin, Dong-Kyu
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.18 no.2
    • /
    • pp.62-67
    • /
    • 2018
  • Hunter syndrome, also known as mucopolysaccharidosis Type II (MPS II), is one of the lysosomal storage diseases caused by a lack of the enzyme iduronate 2-sulfatase (I2S). Lack of the I2S enzyme activity leads to accumulation of the glycosaminoglycans (GAG), causing dysfunction of multiple organs and systems. MPS II is an X-linked recessive disease due to mutation of IDS gene located on long arm of the X chromosome (Xq28). To date, more than 350 mutations of IDS gene have been identified in Hunter syndrome. Phenotypes of MPS II are classified as either severe or attenuated depending on the degree of cognitive impairment. Because the phenotype of MPS II is related to the type of mutation, identifying mutations is useful in predicting prognosis. We recently had a case of MPS II diagnosed by exome sequencing in a 7 month old boy with infantile spasm uncontrolled by AED. He was diagnosed with hearing loss at 2 months of age, and he took vigabatrin and prednisolone to control infantile spasms diagnosed at 3 months of age. At 6 months of age, whole exome sequencing was performed to evaluate the infantile spasm and hearing loss in this patient, and the mutation c.851C>T (p.Pro284Leu) inherited from hemizygous mother was revealed. The results of urine Cetylpyridinium Chloride (CPC) precipitation test, which were negative until 8 months of age, were positive from 9 months of age. We report a case of MPS II diagnosed by exome sequencing and treated through enzyme replacement therapy from 9 months after birth.

  • PDF

The influence of the decision making time by using point-of-care creatinine in patients with acute abdomen (급성 복증 환자에서 현장검사 크레아티닌을 이용한 의사결정 시간의 단축)

  • Choi, Younhyuk;Cho, Sunguk;Ahn, Hongjoon;Min, Jinhong;Jeong, Wonjoon;Ryu, Seung;Oh, Segwang;Kim, Seunghwan;You, Yeonho;Lee, Jinwoong;Park, Jungsoo;Yoo, Insool;Cho, Yongchul
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.663-670
    • /
    • 2018
  • Objective: Radio-contrast abdomino-pelvic computed tomography (APCT) is considered the gold standard diagnostic tool for an acute abdomen in the emergency department. On the other hand, APCT has a risk of contrast-induced nephropathy. Emergency physicians evaluate the creatinine (Cr) level prior to taking a APCT for the above reason but it takes time to evaluation the serum Cr level. This study hypothesized that Cr measured by a point-of-care test (POCT) can shorten the time to making clinically important decisions for patients with an acute abdomen. Methods: This prospective randomized study was conducted between March 2017 and October 2017. The subjects were divided into two groups (Cr measured by laboratory vs. Cr measured by POCT). To analyze the clinical acceptability for creatinine, agreement was demonstrated graphically by Bland-Altman plots. This study compared the time to make a clinically important decision by physicians and the length of stay at the emergency department in both groups. Results: A total of 76 patients were eligible for the study, 38 patients were assigned to each group. There was no statistically significant difference in the time to the first medical examination (P=0.222) and emergency department stay time (P=0.802). On the other hand, the time to recognition of the Cr level (P<0.001), time to performing APCT (P<0.001), time to decision making (P<0.001), and time to initiation of treatment (P<0.001) were shortened significantly in the point-of-care creatinine group. Conclusion: In this study, the POCT for creatinine can allow rapid decision making by shortening the time to performing the radio-contrast APCT than the laboratory for patients with an acute abdomen.

Decreased Nocturnal Blood Pressure Dipping in Patients with Periodic Limb Movements in Sleep (수면중 주기성 사지 운동에서 나타나는 야간 혈압 강하의 감소)

  • Lee, Mi Hyun;Choi, Jae-Won;Oh, Seong Min;Lee, Yu Jin
    • Sleep Medicine and Psychophysiology
    • /
    • v.25 no.2
    • /
    • pp.51-57
    • /
    • 2018
  • Objectives: Previous studies have shown that periodic limb movements in sleep (PLMS) could be one of risk factors for cardiovascular morbidity. The purpose of this study was to investigate the association between PLMS and blood pressure changes during sleep. Methods: We analyzed data from 358 adults (176 men and 182 women) aged 18 years and older who were free from sleep apnea syndrome (Respiratory Disturbance Index < 5) and sleep disorders such as REM sleep behavior disorder or narcolepsy. Demographic characteristics, polysomnography records, and clinical variable data including blood pressure, body mass index, alcohol, smoking, and current medications were collected. In addition, self-report questionnaires including the Beck Depression Index, Epworth Sleepiness Scale and Pittsburgh Sleep Quality Index were completed. Blood pressure change from bedtime to awakening was compared between the two periodic limb movement index (PLMI) groups [low PLMI ($PLMI{\leq}15$) and high PLMI (PLMI > 15)]. Blood pressure change patterns were compared using repeated measures analysis of variance. Results: Systolic blood pressure in the high PLMI group was lower than that in the low PLMI group (p = 0.036). These results were also significant when adjusted for gender and age, but were not statistically significant when adjusted for BMI, alcohol, smoking, anti-hypertension medication use and sleep efficiency (p = 0.098). Systolic blood pressure dropped by 9.7 mm Hg in the low PLMI group, and systolic blood pressure in the high PLMI group dropped by 2.9 mm Hg. There was a significant difference in delta systolic blood pressure after sleep between the two groups in women when adjusted for age, BMI, alcohol, smoking, antihypertensive medication use and sleep efficiency (p = 0.023). Conclusion: PLMS was significantly associated with a decreasing pattern in nocturnal BP during sleep, and this association remained significant in women when adjusted for age, BMI, alcohol, smoking, antihypertension medication use and sleep efficiency related to blood pressure. We suggest that PLMS may be associated with cardiovascular morbidity.

Effects of Gadolinium Contrast agent on Bone Mineral Density Measurement using Dual Energy X-ray Absorptiometry (가돌리늄조영제가 이중에너지 X-선 흡수법을 이용한 골밀도검사에 미치는 영향)

  • Lee, Keun-Ohk;Lee, Min-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Radiographic contrast agents are used for diagnostic purposes and are one of the factors affecting measured values in bone density tests. They are absorbed into tissues and have an effect of increasing the measured values of bone density, so they are avoided as much as possible before performing a bone density test. MRI contrast agents, which have different physical properties and mechanisms of action than radiographic contrast agents, are based on gadolinium, a metal element. They have radiopacity characteristics, so MRI are generally performed prior to examination using radiation. The purpose of this study was to investigate the effects of MRI contrast agents on bone mineral density examination using dual energy X-ray absorption. Two types of gadolinium based MRI contrast agents were injected into an acrylic water tank for each volume, and the humanoid spine phantom was inserted and the BMD and T-score from (L1-L4) were analyzed by scanning a total of 30 times, 5 times for each injection type. The average value of the measured total (L1-L4) bone density for each of the two contrast agents was 0.952±0.052, 0.957±0.050, and 0.956±0.05g/㎠, respectively, for the Gadoterate Meglumine component 0mL, 7.5mL and 15mL, when the gadobutrol components were 0mL, 5mL, and 10mL, there was no statistically significant difference at all sites at 0.953±0.001, 0.954±0.001, and 0.945±0.001g/㎠, respectively(p>0.05). The average value of total T-score was -0.46±0.05, -0.4±0, -0.42±0.04 when the Gadoterate Meglumine component was 0mL, 7.5mL and 15mL, respectively. When the Gadobutrol ingredients were 0mL, 5mL and 10mL, there was no statistically significant difference in all areas, with -0.46±0.05, -0.46±0.05, and 0.5±0.00, respectively. In this experiment, the MRI contrast agent was found to have no effect on bone density tests, using the dual-energy X-ray absorption method. There is a limitation in that physical conditions such as kidney and health conditions etc. were not taken into consideration, so further clinical research is expected to be conducted in the future.

The Effect of Continuous Positive Pressure Therapy for Obstructive Sleep Apnea on Quality of Life : A Single-Institution Study (폐쇄성수면무호흡증에 대한 지속적 양압치료가 삶의 질에 미치는 영향 : 단일기관 연구)

  • Shin, Hyun Suk;Choi, Mal Rye;Kim, Shin il;Hong, Se Yeon;Eun, Hun Jeong
    • Sleep Medicine and Psychophysiology
    • /
    • v.27 no.2
    • /
    • pp.56-66
    • /
    • 2020
  • Objectives: In this study, the clinical characteristics of OSA patients and the quality of life before and after CPAP use were compared to determine the degree of improvement in quality of life according to CPAP use. Methods: Age, sex, height, weight, body mass index, Epworth Sleepiness Scale, Modified Mallampatti Score, Montreal Cognitive Assessment-Korean, and Pittsburgh Sleep Quality Index were compared between men and women through medical records. To understand the degree of improvement in quality of life resulting from use of CPAP, a personal telephone call was made to compare the VAS scores for quality of life before and after CPAP use. Results: In height (HT) (Z = -4.525, p < 0.001), weight (BW) (Z = -2.844, p < 0.05), sleep quality (PSQI) (Z = -2.671, p < 0.05), and arousal index (AI) (Z = -2.105, p < 0.05), there was a difference between men and women (p < 0.05). There was no difference in the remaining variables. Cross-analysis (Chi-square test) confirmed a difference between severity and sex of OSA. It has been found that there is no statistically significant order in size according to level-specific severity of OSA for PreCPAP QOL, PostCPAP QOL, CPAPUse Months, and CPAP4Hr/d (%) (p > 0.05). The difference between AHI before and after CPAP was 36.48 ± 21.54 (t = 11.609, p < 0.001) and the difference between QOL before and after CPAP was -25.43 ± 22.06 (t = -7.901, p < 0.001), both of which were significant (p < 0.001). Conclusion: Among OSA patients, there were differences in height (HT), weight (BW), sleep quality (PSQI), arousal index (AI), and severity of OSA between men and women, but the quality of life before and after CPAP was different. However, there was no difference between men and women in quality of life before and after CPAP. In addition, quality of life in OSA patients improved after using CPAP.

Viral Load Dynamics After Symptomatic COVID-19 in Children With Underlying Malignancies During the Omicron Wave

  • Ye Ji Kim;Hyun Mi Kang;In Young Yoo;Jae Won Yoo;Seong Koo Kim;Jae Wook Lee;Dong Gun Lee;Nack-Gyun Chung;Yeon-Joon Park;Dae Chul Jeong;Bin Cho
    • Pediatric Infection and Vaccine
    • /
    • v.30 no.2
    • /
    • pp.73-83
    • /
    • 2023
  • Purpose: This study aimed to investigate the viral load dynamics in children with underlying malignancies diagnosed with symptomatic coronavirus disease 2019 (COVID-19). Methods: This was a retrospective longitudinal cohort study of patients <19 years old with underlying hemato-oncologic malignancies that were diagnosed with their first symptomatic severe acute respiratory syndrome coronavirus 2 polymerase chain reaction (PCR)-confirmed COVID-19 infection during March 1 to August 30, 2022. Review of electronic medical records and telephone surveys were undertaken to assess the clinical presentations and transmission route of the patients. Thresholds of negligible likelihood of infectious virus was defined as E gene reverse transcription (RT)-PCR cycle threshold (Ct) value ≥25. Results: During the 6-month study period, a total of 43 children with 44 episodes of COVID-19 were included. Of the 44 episodes, the median age of the patients included was 8 years old (interquartile range [IQR], 4.9-10.5), and the most common underlying disease was acute lymphoid leukemia (n=30, 68.2%), followed by patients post-hematopoietic stem cell transplantation (n=8, 18.2%). Majority of the patients had mild COVID-19 (n=32, 72.7%), and three patients (7.0%) had severe/critical COVID-19. Furthermore, 2.3% (n=1) died of COVID-19 associated acute respiratory distress syndrome. The largest percentage of the patients showed E gene RT-PCR Ct value ≥25 between 15-21 days (n=13, 39.4%), followed by 22-28 days (n=10, 30.3%). In 15.2% (n=5), E gene RT-PCR Ct value remained <25 beyond 28 days after initial positive PCR. Refractory malignancy status (β, 67.0; 95% confidence interval, 7.0-17.0; P=0.030) was significantly associated with prolonged duration of E gene RT-PCR <25. A patient with prolonged duration of E gene RT-PCR Ct value <25 was suspected to have infectivity shown by the transmission of the virus to his mother at day 86 after his initial positive test. Conclusions: Children that acquire symptomatic COVID-19 during refractory malignancy state are at a high risk for prolonged shedding warranting PCR-based transmission precautions in this cohort of patients.

A Study on the Radiographic Diagnosis of Caroli's Disease (카롤리병의 방사선학적 진단에 대한 고찰)

  • Yeo-jin Hong;Min-a Kim;Soo-bin Kim;Jin-joo Song;Kyoung-hoon Jang;Min-cheol Jeon;Man-Seok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.385-392
    • /
    • 2023
  • Caroli's disease is a fibrocystic liver disease. Autosomal recessive disorder is characterized by congenital multiple dilatation of the bile duct. Computerized tomography, magnetic resonance imaging, cholangiography and ultrasound are among the methods for diagnosing caroli disease. Computerized tomography is essential for detecting and distinguishing fibroplastic liver disease and is useful for determining intrahepatic bile duct dilatation. However, awareness of the possible side effects of using contrast mediums is necessary. A typical method of magnetic resonance cholangiography is used for magnetic resonance imaging. A non-invasive examination can reduce the pain of the patient, and the anatomical structure of the bile pancreatic duct and the presence or absence of lesions can be easily and quickly observed. Biliary contrast is an effective diagnostic method that can directly visualize various cystic dilatations throughout the enlarged bile duct. However, since this procedure is also an invasive procedure, it is recommended not for diagnosis but for treatment purposes. Ultrasonography can confirm similar findings to computerized tomography. The hepatic artery root is difficult to prove with conventional grayscale ultrasound. However, it is of clinical value in that it can not only describe dilated bile ducts with vascular roots in the tube but also easily identify color Doppler signals in the tube. With the development of video diagnostics, early diagnosis has become possible through computerized tomography, magnetic resonance imaging, cholangiography, and ultrasound. In order to further contribute to the development of video diagnostics so that long-term prognosis can be improved after treatment through early diagnosis, we examined what aspects of each test's caroli disease appear.

The Correction Effect of Motion Artifacts in PET/CT Image using System (PET/CT 검사 시 움직임 보정 기법의 유용성 평가)

  • Yeong-Hak Jo;Se-Jong Yoo;Seok-Hwan Bae;Jong-Ryul Seon;Seong-Ho Kim;Won-Jeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2024
  • In this study, an AI-based algorithm was developed to prevent image quality deterioration and reading errors due to patient movement in PET/CT examinations that use radioisotopes in medical institutions to test cancer and other diseases. Using the Mothion Free software developed using, we checked the degree of correction of movement due to breathing, evaluated its usefulness, and conducted a study for clinical application. The experimental method was to use an RPM Phantom to inject the radioisotope 18F-FDG into a vacuum vial and a sphere of a NEMA IEC body Phantom of different sizes, and to produce images by directing the movement of the radioisotope into a moving lesion during respiration. The vacuum vial had different degrees of movement at different positions, and the spheres of the NEMA IEC body Phantom of different sizes produced different sizes of lesions. Through the acquired images, the lesion volume, maximum SUV, and average SUV were each measured to quantitatively evaluate the degree of motion correction by Motion Free. The average SUV of vacuum vial A, with a large degree of movement, was reduced by 23.36 %, and the error rate of vacuum vial B, with a small degree of movement, was reduced by 29.3 %. The average SUV error rate at the sphere 37mm and 22mm of the NEMA IEC body Phantom was reduced by 29.3 % and 26.51 %, respectively. The average error rate of the four measurements from which the error rate was calculated decreased by 30.03 %, indicating a more accurate average SUV value. In this study, only two-dimensional movements could be produced, so in order to obtain more accurate data, a Phantom that can embody the actual breathing movement of the human body was used, and if the diversity of the range of movement was configured, a more accurate evaluation of usability could be made.