• Title/Summary/Keyword: clinical evaluation

Search Result 5,347, Processing Time 0.033 seconds

The Evaluation of Domestic Immunoradiometric Assay Kit for Alpha-fetoprotein (Alpha-fetoprotein 측정용 국산 방사면역측정법 시약의 평가)

  • Won, Kyoung-Sook;Ryu, Jin-Sook;Moon, Dae-Hyuk;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.353-359
    • /
    • 2000
  • Purpose: Although ${\alpha}$-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for ${\alpha}$-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for ${\alpha}$-fetoprotein (Riakey AFP IRMA $CT^R$, Sin-Jin Medics, Seoul, Korea). Materials and Methods: We evaluated intra- and inter-assay precision, recovery rate, parallelism, and sensitivity of serum ${\alpha}$-fetoprotein measurement using Riakey AFP IRMA $CT^R$ kit. The values of ${\alpha}$-fetoprotein measured by Riakey AFP IRMA $CT^R$ kit were compared with those measured by two foreign commercial kits (${\alpha}$-fetoproteina of Radim and ${\alpha}$-feto.riabead of Abbott). Results: Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within $100{\pm}10%$. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of ${\alpha}$-fetoprotein by Riakey AFP IRMA $CT^R$ and that by two foreign commercial kits(r=0.98). Conclusion: The first Korean domestic immunoradiometric kit for ${\alpha}$-fetoprotein, Riakey AFP IRMA $CT^R$, performed well for clinical use.

  • PDF

The Evaluation of Dynamic Continuous Mode in Brain SPECT (Brain SPECT 검사 시 Dynamic Continuous Mode의 유용성 평가)

  • Park, Sun Myung;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.15-22
    • /
    • 2017
  • Purpose During Brain SPECT study, critical factor for proper study with $^{99m}Tc-ECD$ or $^{99m}Tc-HMPAO$ is one of the important causes to patent's movement. It causes both improper diagnosis and examination failure. In this study, we evaluated the effect of Dynamic Continuous Mode Acquisition compared to Step and Shoot Mode to raise efficacy and reject the data set with movement, as well as, be reconstructed in certain criteria. Materials and Methods Deluxe Jaszczak phantom and Hoffman 3D Brain phantom were used to find proper standard data set and exact time. Step and Shoot Mode and Dynamic Continuous Mode Acquisition were performed with SymbiaT16. Firstly, Deluxe Jaszczak phantom was filled with $Na^{99m}TcO_4$ 370 MBq and obtained in 60 minutes to check spatial resolution compared with Step and Shoot Mode and Dynamic Continuous Mode. The second, the Hoffman 3D Phantom filled with $Na^{99m}TcO_4$ 74 MBq was acquired for 15 Frame/minutes to evaluate visual assessment and quantification. Finally, in the Deluxe Jaszczak phantom, Spheres and Rods were measured by MI Apps program as well as, checking counts with the frontal lobe, temporal lobe, occipital lobe, cerebellum and hypothalamus parts was performed in the Hoffman 3D Brain Phantom. Results In Brain SPECT Study, using Dynamic Continuous Mode rather than current Step and Shoot Mode, we can do the reading using the 20 to 50 % of the acquired image, and during the test if the patient moves, we can remove unneeded image to reduce the rate of restudy and reinjection. Conclusion Dynamic Continuous Mode in Brain study condition enhances effects compared to Step and Shoot Mode. And also is powerful method to reduce reacquisition rate caused by patient movement. The findings further indicate that it suggest rejection limit to maintain clinical value with certain reconstruction factors compared with Tomo data set. Further examination to improve spatial resolution, SPECT/CT should be the answer for that.

  • PDF

Development of an accreditation system for dietary and nutrition related education resources (영양.식생활 교육자료의 인증 시스템 개발 연구)

  • Kim, Ji-Myung;Lee, Kyoung Ae;Park, Yoo Kyoung;Lee, Kyung-Hea;Oh, Sang Woo;Lee, Hee Seung
    • Journal of Nutrition and Health
    • /
    • v.47 no.2
    • /
    • pp.145-156
    • /
    • 2014
  • Purpose: The purpose of this study was to establish accreditation systems of reliable educational materials for nutrition and dietary life which could be used in schools, workplace, and health promotion. Methods: The study was conducted from April 2011 to October 2011. Literature reviews, institutional visits, and telephone interviews were conducted. Expert meetings and advisory councils were held in order to receive feedback on development of the accreditation systems. A survey was conducted for the accreditation procedures on 143 professionals, including professors, researchers, health and medical experts, teachers, nutrition teachers, dietitians, and clinical nutritionists. Results: The final procedure of the developed accreditation system was finalized as follows: 1) receiving application twice per year 2) complete desk review (written evaluation) by three reviewers within two months, 3) board review (all board members) and decision, and 4) notification of results. The accreditation system is set for printed materials, web-site, and materials for activities. The certificate and accreditation mark is issued to the final certified educational materials. Expiration date is established only for the web-site form. The accreditation length lasts for two years, and can be extended by renewal application. Conclusion: The dietary and nutrition related materials, which are certificated by this accreditation system, could impart reliable information and knowledge to both learners and educators, and help them in effective selection of educational materials. Therefore, this accreditation system might be expected to increase satisfaction for teaching and learning about nutrition and healthy dietary life.

The Validation Study of Beck Depression Scale 2 in Korean Version (한국판 벡 우울 척도 2판의 타당화 연구)

  • Lim, Sun-Young;Lee, Eun-Jeong;Jeong, Seong-Won;Kim, Hee-Chul;Jeong, Cheol-Ho;Jeon, Tae-Yeon;Yi, Min-Soo;Kim, Jae-Min;Jo, Hyeon-Ju;Kim, Jeong-Beom
    • Anxiety and mood
    • /
    • v.7 no.1
    • /
    • pp.48-53
    • /
    • 2011
  • Objective : Korean Version of Beck-II Depression Inventory to verify the reliability and validity of the proposed standards are practical and standardized, cut-off score by establishing a baseline indicating the presence of depression and depression On in the evaluation was to evaluate the clinical usefulness. Methods : 739 patients with major depression using the SCID and normal controls were 302 study subjects. Of patients with clinically significant medical condition, or psychotic disorders, organic mental disorder, epilepsy or seizure disorder, eating disorders are associated with patients taking anti-convulsants experienced in the past, patients were excluded from the study. Results : The main findings of this study were as follows. First, with respect to the KBDI-II items, the correlation between them ranged from 0.51 to 0.74, and was 0.60 over all questions. Further, the overall correlation of the KBDI-II plates showing confidence 'normal' than it was verified that. Second, the BDIII was used in each group to examine internal consistency and thus, whether Cronbach's alpha values were greater than 0.94. Third, the principal component analysis sought to extract factors in a way consistent with the results inspected last 3 factors were extracted and the total variance explained was 47.3%. Fourth, the Cutting calculated the score on the KBDI-II for ROC (Receiver operator characteristic) analysis yielding 18 dot, with the highest sensitivity and specificity was seen. Conclusion : Based on the results of this Study, the KBDI-II cut-off point should be valid as prescribed in 18 is considered.

Synthesis of Ultrasound Contrast Agent: Characteristics and Size Distribution Analysis (초음파 조영제의 합성 및 합성된 초음파 조영제의 특성 분석)

  • Lee, Hak Jong;Yoon, Tae Jong;Yoon, Young Il
    • Ultrasonography
    • /
    • v.32 no.1
    • /
    • pp.59-65
    • /
    • 2013
  • Purpose: The purpose of this study is to establish the methodology regarding synthesis of ultrasound contrast agent imaging, and to evaluate the characteristics of the synthesized ultrasound contrast agents, including size or degradation interval and image quality. Materials and Methods: The ultrasound contrast agent, composed of liposome and SF6, was synthesized from the mixture solution of $21{\mu}mol$ DPPC (1, 2-Dihexadecanoyl-sn-glycero-3-phosphocholine, $C_{40}H_{80}NO_8P$), $9{\mu}mol$ cholesterol, $1.9{\mu}mol$ of DCP (Dihexadecylphosphate, $[CH_3(CH_2)_{15}O]_2P(O)OH$), and chloroform. After evaporation in a warm water bath and drying during a period of 12-24 hours, the contrast agent was synthesized by the sonication process by addition of buffer and SF6 gas. The size of the contrast agent was controlled by use of either extruder or sonication methods. After synthesis of contrast agents, analysis of the size distribution of the bubbles was performed using dynamic light scattering measurement methods. The degradation curve was also evaluated by changes in the number of contrast agents via light microscopy immediate, 12 hours, 24 hours, 36 hours, 48 hours, 60 hours, 72 hours, and 84 hours after synthesis. For evaluation of the role as an US contrast agent, the echogenicity of the synthesized microbubble was compared with commercially available microbubbles (SonoVue, Bracco, Milan, Italy) using a clinical ultrasound machine and phantom. Results: The contrast agents were synthesized successfully using an evaporation-drying-sonication method. The majority of bubbles showed a mean size of 154.2 nanometers, and they showed marked degradation 24 hours after synthesis. ANOVA test revealed a significant difference among SonoVue, synthesized contrast agent, and saline (p < 0.001). Although no significant difference was observed between SonoVue and the synthesized contrast agent, difference in echogenicity was observed between synthesized contrast agent and saline (p < 0.01). Conclusion: We could synthesize ultrasound contrast agents using an evaporation-drying-sonication method. On the basis of these results, many prospective types of research, such as anticancer drug delivery, gene delivery, including siRNA or microRNA, targeted molecular imaging, and targeted therapy can be performed.

Effects on the Thermal Change of the Face Follow Electroacupunctyre on Hapkok($LI_4$), Sangan($LI_3$) (合谷($LI_4$), 三間($LI_3$)의 電針刺戟이 顔面部 領域 溫度變化에 미치는 影響)

  • Yun, Jeong-hun;Kim, Jong-Han;Hwang, Chung-yeon;Lim, Kyu-sang
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.12 no.2
    • /
    • pp.222-247
    • /
    • 1999
  • The back ground and purpose : The acupuncture of oriental medicine is very important in treatments. Until now it has been researched according to the meridian and qi xue(氣血) phenomenon of oriental medicine's theory. As electroacupuncture is one of acupuncture treatments, it will show more objective index to observe the meridian and qi xue(氣血) phenomenon. And then, I studied the effects on the thermal change of the face following electroacupuncture treatment. Objective and Methods : This study was performed from January 1999 to March 1999 on 10 healthy students. The objective was divided into three groups, those were the control group A(n=10), the group B(n=10) of electroacupuncture on Hapkok($LI_4$), Samgan($LI_3$) and the group C(n=10) of electroacupuncture on Shinmun($H_7$), T' ongni($H_5$). First, in the control group A, we took a picture for 10 men without any stimulation with the Digital Infrared Thermograph Imaging(D.I.T.I.) and did 3min after, 10min after, 15min after, 25min after, 45min after respectively. Second, in the electroacupuncture treatment group B, we took a picture for 10 men without any stimulation, and then treat electroacupuncture on Hapkok($LI_4$), Samgan($LI_3$) and took a picture immediately(3min after), 10min after, 15min after and remove needle and took a picture in the same way respectively. Third, in the electroacupuncture treatment group C, we took a picture for 10 men without any stimulation, and then treat electroacupuncture on Shinmun($H_7$), T'ongni($H_5$) and took a picture in the second way respectively. Results: 1. In healthy men, average skin temperture about Yonghyang($LI_{20}$) area was higher than Soryo($G_{25}$) or Chich'ang($S_4$) area. They were Soryo($G_{25}$) area $31.495{\pm}0.766^{\circ}C$, Rt. Yonghyang($LI_{20}$) area $31.664{\pm}0.936^{\circ}C$, Lt. Yonghyang ($LI_{20}$)area $31.686{\pm}0.767^{\circ}C$, Rt. Chich'ang($S_4$) area $31.226{\pm}0.875^{\circ}$, Lt. Chich'ang ($S_4$) area $31.453{\pm}0.855^{\circ}C$. 2. In the control group A, the skin temperature of Soryo($G_{25}$) showed the increase or decrease in below ${\Delta}0.1^{\circ}C\;except\;0.265{\pm}0.594^{\circ}C$ in 25min, but not significantly. 3. About Soryo($G_{25}$) area, the skin temperature decreased significantly after electroacupuncture immediately. ${\Delta}T $of the group B was $-0.970{\pm}0.87\;1^{\circ}C$, which was larger than one of the group C which was $-0.707{\pm}0.624^{\circ}C$ at 3min. And then ${\Delta}T$ of the group C was increase valuable at 25min, 45min. 4. About Yonghyang($L1_{25}$) area, the left ${\Delta}T$ of the group B showed below $0.2^{\circ}C$ or so in contrast to the right it. In the group C, on the both side showed continous increase of temperature as following times. 5. About Chich'ang($S_4$) area, the skin temperature increased valuable $0.3^{\circ}C$ or so on the both side and later inclined to decrease in the group B but not significantly. In the group C, it increased valuable on the both side. 6. The skin temperature of electroacupuncture treatment group B, C were more increase than the control group A except Lt. Yonghyang($LI_{20}$) area in the group B. The temperature of group C were more increase than the group B wholly. Conclusion : The above results indicate that D.I.T.I. is a useful method to observe and fallow-up the effects and the changes by electroacupuncture stimulation on objective evaluation of phenomenon for the meridian system and character. Thus, continuous thermographic study will be needed for more clinical application such as acupuncture and medicine or laser therapy according to oriental medicine.

  • PDF

Difference of Somatic Symptoms between Anxiety Disorder and Major Depressive Disorder and Their Domainal Association with Suicidal Idealization, Plan and Attempts (불안 장애와 주요우울장애에서 나타나는 신체 증상과 증상군에 따른 자살 사고, 계획, 행동과의 관계 고찰)

  • Ahn, Jun Seok;Kim, Eun young;Cho, Maeng Je;Hong, Jin Pyo;Hahm, Bong-Jin;Chung, In-Won;Ahn, Joon-Ho;Jeon, Hong Jin;Seong, Su Jeong;Lee, Dong-Woo
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.24 no.2
    • /
    • pp.174-183
    • /
    • 2016
  • Objectives : The aim of this study is to evaluate difference of somatic symptoms of anxiety disorder and major depressive disorder and domainal association with suicidal idealization, plan, and attempts. Methods : A total of 359 adults diagnosed with major depressive disorder and anxiety disorder of last one year participated. Participants interviewed with certain sections of Korean version of Composite International Diagnostic interview of CIDI. Sections of interests includes questionnaires regarding somatic symptoms and suicidal idea, plan and attempts of last one year. Results : Chest pain shows more prevalence in major depressive disorder. Symptoms of Headache and loose stool are more prevalent in anxiety disorder. Difficulty in equilibrium and fainting spells are more common somatic complaints of co-diagnosis states of anxiety disorder and major depressive disorder. Comparing 3 domains of pain symptoms, gastrointestinal symptoms and pseudo-neurological symptoms, pain symptom domains, gastrointestinal symptoms domain shows significant statistic difference between diagnosis. Average somatic symptom numbers of each symptom domains increase through suicidal idealization, plan and attempt, accordingly. Conclusions : Our finding shows some of somatic symptoms are more prevalent at certain diagnosis. Since increasing numbers of somatic complaints of each symptom domains goes with the suicidal idealization to suicidal attempts, proper psychiatric evaluation and consultations are crucial for patients with numerous somatic complaints in non-psychiatric clinical settings.

Full mouth rehabilitation for a patient with vertical dimension loss using digital diagnostic analysis: A clinical report (수직고경이 감소된 환자의 디지털 진단 분석을 이용한 완전 구강 회복 증례)

  • Choi, Yeawon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Kim, Hyeong-Seob;Kwon, Kung-Rock;Pae, Ahran
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.487-496
    • /
    • 2021
  • Full mouth rehabilitation is re-organizing the occlusion of the remaining teeth and missing teeth considering the functions, esthetics, and neuromuscular harmony. With the loss of multiple teeth, the patient's occlusal plane gradually collapses and the vertical dimension can be reduced. Since reduced vertical dimension can be a potential etiology of the temporomandibular joint and masticatory muscles, prosthetic restoration with increased vertical dimension is required. This case report is about a 68 years old patient with vertical dimension loss due to worn dentition and multiple loss of teeth. In this case, the loss of vertical dimension is assessed carefully using the digital dentistry technology. Using CAD software in digital analysis step, the occlusal plane was established and evaluated using several criteria. Orienting the position of the bone and teeth using CBCT image, patient's condition was visualized in 3 dimension and treatment planning was possible virtually. The information that matches the patient's condylar position with the articulator, which is the virtual face bow, is reproduced on the actual articulator, and evaluated again. After the evaluation, provisional prosthesis was fabricated and it was confirmed that the patient adapts without any abnormality. This was implemented as a final prosthesis. As a result, the patient obtained satisfying results, utilizing the benefits of digital dentistry technology and traditional methods.

Evaluation of the Usefulness of the Transmittance of Metal Filaments Fabricated by 3D Printers in Radiation Therapy (방사선 치료에서 3D 프린터로 제작된 금속 필라멘트의 투과율에 관한 유용성 평가)

  • Kwon, Kyung-Tae;Jang, Hui-Min;Yoon, Myeong-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.965-973
    • /
    • 2021
  • Since radiation therapy is irradiated with high-energy X-rays in a variety of at least 20 Gy to 80 Gy, a high dose is administered to the local area where the tumor is located, and various side effects of some normal tissues are expected. Currently, in clinical practice, lead, a representative material, is used as an effort to shield normal tissues, but lead is classified as a heavy metal harmful to the human body, and a large amount of skin contact can cause poisoning. Therefore, this study intends to manufacture a measurement sheet that can compensate for the limitations of lead using the materials Tungsten, Brass, and Copper of the 3D printer of the FDM (Fused Deposition Modeling) method and to investigate the penetration performance. Tungsten mixed filament transmission measurement sheet size was 70 × 70 mm and thickness 1, 2, 4 mm using a 3D printer, and a linear accelerator (TrueBeam STx, S/N: 1187) was measured by irradiating 100 MU at SSD 100 cm and 5 cm in water using a water phantom, an ion chamber (FC-65G), and an elcetrometer (PTW UNIDOSE), and the permeability was evaluated. As a result of increasing the measurement sheet of each material by 1 mm, in the case of Tungsten sheet at 3.8 to 3.9 cm in 6 MV, the thickness of the lead shielding body was thinner than 6.5 cm, and in case of Tungsten sheet at 4.5 to 4.6 cm in 15 MV. The sheet was thinner than the existing lead shielding body thickness of 7 cm, and equivalent performance was confirmed. Through this study, the transmittance measurement sheet produced using Tungsten alloy filaments confirmed the possibility of transmission shielding in the high energy region. It has been confirmed that the usability as a substitute is also excellent. It is thought that it can be provided as basic data for the production of shielding agents with 3D printing technology in the future.

The influence of the decision making time by using point-of-care creatinine in patients with acute abdomen (급성 복증 환자에서 현장검사 크레아티닌을 이용한 의사결정 시간의 단축)

  • Choi, Younhyuk;Cho, Sunguk;Ahn, Hongjoon;Min, Jinhong;Jeong, Wonjoon;Ryu, Seung;Oh, Segwang;Kim, Seunghwan;You, Yeonho;Lee, Jinwoong;Park, Jungsoo;Yoo, Insool;Cho, Yongchul
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.663-670
    • /
    • 2018
  • Objective: Radio-contrast abdomino-pelvic computed tomography (APCT) is considered the gold standard diagnostic tool for an acute abdomen in the emergency department. On the other hand, APCT has a risk of contrast-induced nephropathy. Emergency physicians evaluate the creatinine (Cr) level prior to taking a APCT for the above reason but it takes time to evaluation the serum Cr level. This study hypothesized that Cr measured by a point-of-care test (POCT) can shorten the time to making clinically important decisions for patients with an acute abdomen. Methods: This prospective randomized study was conducted between March 2017 and October 2017. The subjects were divided into two groups (Cr measured by laboratory vs. Cr measured by POCT). To analyze the clinical acceptability for creatinine, agreement was demonstrated graphically by Bland-Altman plots. This study compared the time to make a clinically important decision by physicians and the length of stay at the emergency department in both groups. Results: A total of 76 patients were eligible for the study, 38 patients were assigned to each group. There was no statistically significant difference in the time to the first medical examination (P=0.222) and emergency department stay time (P=0.802). On the other hand, the time to recognition of the Cr level (P<0.001), time to performing APCT (P<0.001), time to decision making (P<0.001), and time to initiation of treatment (P<0.001) were shortened significantly in the point-of-care creatinine group. Conclusion: In this study, the POCT for creatinine can allow rapid decision making by shortening the time to performing the radio-contrast APCT than the laboratory for patients with an acute abdomen.