Validity of the Wii Balance Board for Evaluation of Medial Patellar Luxation in Small Sized Dog

  • Lee, Shinho;Lee, Joo-Myoung;Park, Hyunjung;Cha, Yuri;Cheong, Jongtae
    • Journal of Veterinary Clinics
    • /
    • v.36 no.6
    • /
    • pp.297-300
    • /
    • 2019
  • Wii® balance board (WBB) is a device that can measure and record body sway. This study was conducted to evaluate the reliability of WBB in small sized dog as inexpensive, portable and convenient tool. The center of pressure path length (CPPL) and 95% confidence ellipse area (Area 95) were evaluated with only two plates of WBB. The parameters were evaluated between no load (0 kg) and mass group (0.25-4 kg on each one plate). 23 dogs (2.3-7.3 kg) were evaluated for with hindlimb standing for 10 seconds. The mass group showed a significant value in comparison to the no load during the measurement. And intra-class correlation coefficients (ICCs) between CPPL and Area 95 revealed very high both mass and dog group. In the evaluation of medial patellar luxation (MPL) as a diagnostic tool, 80 dogs with MPL and 23 non-affected dogs were used. In studies of CPPL and Area 95, significant differences were found between non-affected and MPL groups for 10 and 30 seconds, respectively. The WBB can be used as a valid tool for evaluating hind limb standing balance and can be useful as an objective tool to present clinical results in small sized dog with MPL.

Cutaneous Patches to Monitor Myoelectric Activity of the Gastrointestinal Tract in Postoperative Pediatric Patients

  • Taylor, Jordan S.;Ruijter, Vivian de;Brewster, Ryan;Navalgund, Anand;Axelrod, Lindsay;Axelrod, Steve;Dunn, James C.Y.;Wall, James K.
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.22 no.6
    • /
    • pp.518-526
    • /
    • 2019
  • Purpose: Limited means exist to assess gastrointestinal activity in pediatric patients postoperatively. Recently, myoelectric gastrointestinal activity recorded by cutaneous patches has been shown in adult patients to be predictive of clinical return of gastrointestinal function postoperatively. The aim of this case series is to demonstrate the feasibility of this system in pediatric patients and to correlate myoelectric signals with return of bowel function clinically. Methods: Pediatric patients undergoing abdominal surgery were recruited to have wireless patches placed on the abdomen within two hours postoperatively. Myoelectric data were transmitted wirelessly to a mobile device with a user-interface and forwarded to a cloud server where processing algorithms identified episodes of motor activity, quantified their parameters and nominally assigned them to specific gastrointestinal organs based on their frequencies. Results: Three patients (ages 5 months, 4 year, 16 year) were recruited for this study. Multiple patches were placed on the older subjects, while the youngest had a single patch due to space limitations. Rhythmic signals of the stomach, small intestine, and colon could be identified in all three subjects. Patients showed gradual increase in myoelectric intestinal and colonic activity leading up to the first recorded bowel movement. Conclusion: Measuring myoelectric intestinal activity continuously using a wireless patch system is feasible in a wide age range of pediatric patients. The increase in activity over time correlated well with the patients' return of bowel function. More studies are planned to determine if this technology can predict return of bowel function or differentiate between physiologic ileus and pathologic conditions.

The clinical usefulness of closed reduction of nasal bone using only a periosteal elevator with a rubber band

  • Park, Young Ji;Ryu, Woo Sang;Kwon, Gyu Hyeon;Lee, Kyung Suk
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.5
    • /
    • pp.284-288
    • /
    • 2019
  • Background: Closed reduction of nasal fracture with various instrument is performed to treat nasal fracture. Depending on the type of nasal fracture and the situation in which it is being operated, the surgeon will determine the surgical tool. The objective of this study was to investigate whether a periosteal elevator (PE) was a proper device to perform closed reduction for patients with simple nasal fractures. Methods: From March 2018 to December 2018, 50 cases of simple nasal bone fracture underwent closed reduction performed by a single surgeon. These patients were divided into two groups randomly: nasal bone reduction was performed using only PE (freer) and nasal bone reduction was performed using Walsham, Asch forcep, and Boies elevator (non-freer, non-PE). Results: The paranasal sinus computed tomography was performed on patients before and after operation to carry out an accurate measurement of reduction distance at the same level. According to the results, the interaction between instruments and fracture types had a significant influence on reduction distance (p = 0.021). To be specific, reduction distance was significantly (p= 0.004) increased by 2.157 mm when PE was used to treat patients with partial displacement compared to that when non-PEs were used. Conclusion: Closed reduction using PE and other elevator is generally an effective treatment for nasal fracture. In partial-displacement type of simple nasal fracture, closed reduction using PE can have considerable success in comparison with using classic instruments.

Comparison of surface topography and roughness in different yttrium oxide compositions of dental zirconia after grinding and polishing

  • Shin, Hyun-Sub;Lee, Joon-Seok
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.258-267
    • /
    • 2021
  • PURPOSE. The purpose of this study was to compare the surface roughness, phase transformation, and surface topography of dental zirconia with three different yttrium oxide compositions under same grinding and polishing conditions. MATERIALS AND METHODS. Three zirconia disks (IPS e.max ZirCAD LT, MT, MT multi, Ivoclar Vivadent AG, Schaan, Liechtenstein) were selected for experimental materials. Sixty-nine bar-shaped specimens were fabricated as 12.0 × 6.0 × 4.0 mm using a milling machine and glazing was conducted on 12.0 × 6.0 mm surface by same operator. With a custom polishing device, 12.0 × 6.0 mm surfaces were polished under same condition. Surface roughness (Ra[㎛]) was measured before grinding (C), after grinding (G), and at every 3 steps of polishing (P1, P2, P3). X-ray diffraction and FE-SEM observation was conducted before grinding, after grinding, and after fine polishing (P3). Statistical analysis of surface roughness was performed using Kruskal-Wallis test and Mann-Whitney-U test was used as a post hoc test (α = .05). RESULTS. There were no significant differences of surface roughness between LT, MT, and MM groups. In LT, MT, and MM groups, P3 groups showed significantly lower surface roughness than C groups. X-ray diffraction showed grinding and polishing didn't lead to phase transformation on zirconia surface. In FE-SEM images, growths in grain size of zirconia were observed as yttrium oxide composition increases. CONCLUSION. Polished zirconia surface showed clinically acceptable surface roughness, but difference in yttrium oxide composition had no significant influence on the surface roughness. Therefore, in clinical situation, zirconia polishing burs could be used regardless of yttrium oxide composition.

The Relationship Study between Cumulative Fatigue and Stress of Seafarers by Evaluating Autonomic Nervous Functions and Survey Studies (선원의 자율신경 기능평가에 의한 누적피로도 및 스트레스와 조사연구 사이의 관련성 연구)

  • Kim, Byeongjo;Lee, Junghun;Lee, Sookyoung;Kwon, Haeyeon;Kwon, Youngtae;Park, Yongsun;Chae, Byeonggeun
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.6 no.4
    • /
    • pp.1-13
    • /
    • 2018
  • Purpose : The purpose of this study has been performed to find the relationship between seafarers' cumulative fatigue and stress by evaluating autonomic nervous functions and the results of surveys conducted using questionnaires. Methods : The subjects were seafarers working on various ships (home trade ships) of South Korea, who were healthy adults without any diseases, as confirmed through preliminary surveys were recruited through simple random sampling. A device that measures autonomic nervous functions by analyzing heart rate variability, which is also used often in clinical diagnoses and studies at universities, university hospitals, and general hospitals was used to measure the seafarers' cumulative fatigue and stress. Pearson's correlation analyses were also conducted to test the relationship between cumulative fatigue and stress measured by evaluating autonomic nervous functions and the results of surveys conducted with questionnaires. Results : There was no correlation between mean cumulative fatigue measured for each ship type and seafarers position through autonomic nervous functions evaluation and fatigue severity scale (FSS). There also was no correlation between the mean levels of stress measured for each ship type and seafarers position through autonomic nervous functions evaluation and survey scores of Korean occupational stress scale (KOSS). Conclusion : Therefore, in order to prevent man-made accidents in the sea among seafarers working with irregular port entry/departure schedules and under environments involving continued vibration, noises, and shaking, it is necessary to analyzed cumulative fatigue and stress scientifically and objectively, such as through autonomic nervous functions evaluation rather than through surveys.

Convergence and integration study related to development of digital contents for radiography training using dental radiograph and augmented reality (치과방사선사진과 증강현실을 활용한 방사선촬영법 숙련용 디지털 콘텐츠 개발에 대한 융복합 연구)

  • Gu, Ja-Young;Lee, Jae-Gi
    • Journal of Digital Convergence
    • /
    • v.16 no.12
    • /
    • pp.441-447
    • /
    • 2018
  • This study aims to develop digital techniques that enable repeated practice of dental radiography using augmented reality technology. A three-dimensional object was fabricated by superimposing a photograph of an adult model and a computed tomography image of a manikin phantom. The system was structured using 106 radiographs such that one of these saved radiographs is opened when the user attempts to take a radiograph on a mobile device. This system enabled users to repeatedly practice at the pre-clinical stage without exposure to radiation. We attempt to contribute to enhancing dental hygienists' competency in dental radiography using these techniques. However, a system that enables the user to actually take a radiograph based on face recognition would be more useful in terms of practice, so additional studies are needed on the topic.

Development of PVDF sensor and system to detect breathing sounds during deep sedation (진정 마취 시 호흡음 검출을 위한 PVDF 센서 및 시스템 개발)

  • Lee, Seung-Hwan;Li, Xiong;Im, Jae-Joong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.153-159
    • /
    • 2019
  • Respiration is one of the important vital signs to determine the condition of the patient. Especially during deep sedation, since the patient's apnea and hypopnea are difficult to detect without continuous monitoring, there is a need for a continuous respiration monitoring method that can accurately and simply determine the patient's respiratory condition. Currently, respiration monitoring methods using various devices have been developed, but these methods have not only late response time but also low reliability at the clinical stage. In this study, attachable sensor using PVDF(polyvinylidene fluoride) film and a monitoring device which could detect abnormal symptoms of breathing in early stage during deep sedation. The results of this study can be used in various medical fields including not only in the area of remote monitoring for respiration related sleep monitoring but also in routine monitoring during deep sedation.

Characteristics of radiographic images acquired with CdTe, CCD and CMOS detectors in skull radiography

  • Queiroz, Polyane Mazucatto;Santaella, Gustavo Machado;Lopes, Sergio Lucio Pereira de Castro;Haiter-Neto, Francisco;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.339-346
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the image quality, diagnostic efficacy, and radiation dose associated with the use of a cadmium telluride (CdTe) detector, compared to charge-coupled device (CCD) and complementary metal oxide semiconductor(CMOS) detectors. Materials and Methods: Lateral cephalographs of a phantom (type 1) composed of synthetic polymer filled with water and another phantom (type 2) composed of human skull macerated with polymer coating were obtained with CdTe, CCD, and CMOS detectors. Dosimeters placed on the type 2 phantom were used to measure radiation. Noise levels from each image were also measured. McNamara cephalometric analysis was conducted, the dentoskeletal configurations were assessed, and a subjective evaluation of image quality was conducted. Parametric data were compared via 1-way analysis of variance with the Tukey post-hoc test, with a significance level of 5%. Subjective image quality and dentoskeletal configuration were described qualitatively. Results: A statistically significant difference was found among the images obtained with the 3 detectors(P<0.05), with the lowest noise level observed among the images obtained with the CdTe detector and a higher subjective preference demonstrated for those images. For the cephalometric analyses, no significant difference (P>0.05) was observed, and perfect agreement was seen with regard to the classifications obtained from the images acquired using the 3 detectors. The radiation dose associated with the CMOS detector was higher than the doses associated with the CCD (P<0.05) and CdTe detectors(P<0.05). Conclusion: Considering the evaluated parameters, the CdTe detector is recommended for use in clinical practice.

Study on the Effect of Light Emitting Diode Irradiation on Improving Skin Condition (Light Emitting Diode 조사가 피부상태 개선에 미치는 효과 연구)

  • Lee, Jung-Hee;Ha, Sung-Yi;Moon, Ji-Sun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.1798-1805
    • /
    • 2020
  • This study attempted to numerically verify specific effects on skin condition improvement by measuring and comparing changes in skin conditions such as pores, wrinkles, and sebum of LED masks for beauty devices with low output among light sources. 18 healthy women (4 weeks in the control group and 4 weeks in the experimental group) were conducted once a week for 8 weeks. As a result of measuring the skin condition of pores, wrinkles, and sebum, it was confirmed that the skin condition improved significantly as the LED irradiation progressed, and the difference between the groups by measurement period of the experimental group and the control group also showed significant differences in pores, wrinkles, and sebum (p< .001, p<.05). This is meaningful in that it can be presented as clinical information and quantitative data by preparing continuous data in an academic sense by proving the effect of improving the LED mask as a beauty device. It is also suggested that in the future, follow-up studies to prove more effective skin improvement will be conducted.

Effectiveness and Technical Considerations of Solitaire Platinum 4×40 mm Stent Retriever in Mechanical Thrombectomy with Solumbra Technique

  • Yi, Ho Jun;Sung, Jae Hoon;Lee, Dong Hoon;Song, Seung Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.30-38
    • /
    • 2021
  • Objective : The Solitaire Platinum 4×40 mm stent retriever contains radiopaque markers with a long length. We evaluated the effect of Solitaire Platinum 4×40 mm stent retriever in Solumbra technique thrombectomy, and compared it with shorter Solitaire stent retrievers. Methods : A total of 70 patients who underwent Solumbra technique thrombectomy with equal diameter (4 mm) and different length (40 vs. 20 mm) Solitaire stent retrievers were divided into two groups : the Solitaire Platinum 4×40 mm stent (4×40) group and the Solitaire FR 4×20 mm stent or Solitaire Platinum 4×20 mm stent (4×20) group. The clinical outcomes, Thrombolysis in Cerebral Infarction score, the first pass reperfusion status, and complications were evaluated and compared between the two groups. Multivariate analysis was performed to evaluate the predictive factors for reperfusion and complete reperfusion from the first pass. Results : Higher first-pass reperfusion and complete reperfusion were achieved in the 4×40 group (68.0% and 48.0%) than in the 4×20 group (46.7% and 33.3%; p=0.004 and 0.007, respectively). In multivariate analysis, radiopaque device and longer stent retriever were correlated with first-pass reperfusion (p=0.014 and 0.008, respectively) and first-pass complete reperfusion (p=0.022 and 0.012, respectively). Conclusion : Our study demonstrated the usefulness of the Solitaire Platinum 4×40 mm stent retriever, which led to higher first-pass reperfusion and complete reperfusion rates than the Solitaire FR 4×20 mm stent or the Solitaire Platinum 4×20 mm stent, especially in Solumbra technique thrombectomy.