• 제목/요약/키워드: clinic

검색결과 8,147건 처리시간 0.045초

황제내경(黃帝內經)의 맥(脈) 이론(理論)과 진맥법(診脈法)의 변화(變化)에 관(關)한 연구(硏究) (A Study of Mac(脈)-Theory and Change of Mac(脈)-Diagnosis in Whang Di Nei Qing(黃帝內經))

  • 나경찬;박현국
    • 동국한의학연구소논문집
    • /
    • 제2권1호
    • /
    • pp.73-105
    • /
    • 1993
  • To say nothing of the orient and the west, the human beings discover the method of Jin Mac(診脈) by the way that observe disease. But oriental medicine devise special method of Jin Mac(診脈) in the study of Kyoung Mac(經脈). Although sip-ei Kyoung Mac Jin(十二經脈診), Sam Bu Gu Who Jin(三部九候診), In Young Mac Gu Jin(人迎脈口診), Chon Kwan Chuck Jin(寸關尺診) namely Yuk Bu Jung Wee Jin Mac (六部定位診脈) that is used today are devised, it has changed naturally by the changing treatment and the introduction of Yuin Yang(陰陽) and five element(五行). Many methods dg Jin Mac(診脈), it had not developped successing alternative, it had developped of declined by it's own way. 1. Results for the birth of Mac(脈) 1) Mac(脈), it means Kyoung Mac(經脈), at first entirelly Mac(脈), is seized a blood vessel that flows in the body. As presumed today, after finding many acupunture point, a general idea of Mac(脈) is not maked by the line that connect point and point, it connect between acupunture point and acupunture point. 2) Like blood flows in Hyul Mac(血脈), Gie(氣) flows in Kyoung Mac(經脈). The two things relate deeply each other. In a general idea or actrally Kyoung Rak(經洛), the two things sometimes accord, sometimes seperate, sometimes mix alternative. 3) Hyul Mac(血脈) and Kyoung Mac(經脈), we call it Mac(脈) entirely Kyoung Mac(經脈), is a way that manifest disease through Kyoung Mac(經脈) or a boundary that disease belongs to it method of Mac Jin(脈診) individual that disease of Kyoung Mac(經脈) is diagnosed by the jumping situation of Hyul Mac(血脈). 4) In method of Moxa, athough the pathology and the diagnostic of Mac(脈) are created by finding Mac(脈). Finding acupunture have opportunitty fot Mac Jin(脈診) and treatment. 2. Results of Kyoung Mac Mac Jin(經脈脈診) 1) In theory of kyoung Rak(經洛), disease are resumed for malfunction of Young Wee(榮衛) that flows in Kyung Rak(經洛). So to speak, in treatment of Kyoung Rak area, the purpose of diagnosis observe the situation of disease and cause. For fitting the purpose of diagnosis, the dead had esatablised four-diagnosis method mangMunMnnJeul(望聞問切), in four-diagnosis(四診法), the core is Mac Jin(脈診). 2) sip-ei Kyoung Mac Mac Jin(十二經脈診) had existed as Kyoung Mac Mac Jin(經脈脈診), it precedes Sam Bu Gu Who Jin(三部九候診). In Young Ki Gu Mac(人迎脈口診). 3) Although Bu Yang Mac(趺陽脈), So Um Mac(少陰脈) is a part of Sip-ei Kyoung Mac(十二經脈診), they developped especially because they located in the point of Won Hyul(原穴) and they are convenient for diagnose. 4) Sip-ei Kyoung Mac Mac Jin(十二經脈診), which belongs to Bu Yang Mac(趺陽脈) and So Urn Mac(少陰脈), is not important for the comming age medical books compared with Mac Kyoung(脈經). 3. Results gor Sam Bu Gu Who Jin(三部九候診) 1) Mac Jin(脈診) of Sam Bu Gu Who(三部九候), which is noted in the theory of Sam Bu Gu Who(三部九候診) of So Mun(素問), belongs to Kyoung Mac Mac Jin's(經脈脈診) geneology, Sip-ei Kyoung Mac Mac Jin(十二經脈診) is arranged, simplicated by the idealogy three talents(三才思想) in the heaven and the earth. 2) What Sam Bu Gu Jin(三部九候診) is regardded as very important in So Mun(素問), the editor of So Mun(素問) recognize the meaning that one discover disease early in this method of diagnosis. 3) After Young chu(靈樞), Nan Kyoung(難經) it is lacked the method of Sam Bu Gu Who Jin(三部九候診) in the books that treatment has changed. Sam Bu Gu Who Jin(三部九候診) based on actually clinic appropriate. 4. results for In Young Mac Gu Jin(人迎脈口診) 1) In Young Mac Gu Jin(人迎脈口診) is the method of comparative Mac Jin(脈診) according to the theory of Yin Yang(陰陽), it is presumed after Sam Bu Gu Who Jin(三部九候診), it had perished in parallel with the development of the theory of five elelment(五行). The development of the acupunture, the perishment of the treatment of negative(刺絡). 2) In Young Mac Gu Jin(人迎脈口診), Wang Suk Wha(王叔和) recreated that the left is In Young(人迎), the right is Kie Gu(氣口). In future generations by Jin Mu Taek(陳無擇) who is the writer of Sam In Bang(三因方). In Young Mac Gu Jin(人迎脈口診) is a measure for disease which classify it's inside and outside cause. 5. Results for Chon Gu Mac Jin(寸口脈診) 1) What we say Mac Jin(脈診) of Chon Gu(寸口) two means are used in commn. First case, we simply say the area of Chon Gu(寸口), second case, we say Chon Kwan Chuk Jin(寸口尺診) reducingly. Chon Gu(寸口) is the area which is the radial artery of wrist joint. What we attemp diagnose by only Chon Gu Mac(寸口脈), it is clearly shoued in the method of Nan Kyoung, five Nan(難經五難). 2) Because Jin Mac(診脈) is made in only Chon Gu(寸口), that is the area in which is concentated Kyoung Kee(經氣). That is the birth of Jin Kee(眞氣) and Jin Kee(眞氣) is related with disease. We can diagnose disease by taking Chon Gu(寸口). 3) Chuk Jin(尺診) in Nae Kyoung(難經) have two things. One is Il Chuk(一尺), the other is Chon Kwan Chu(寸關尺). 4) Chuk Chon Jin(尺寸診) is the method which diagnose the difference of point and the condition of Mac(脈) by dividing a part of Chuk(尺) in the area of Chon Gu(寸口). In Chon Gu Jin(寸口診), by introducing the theory of Yin Yang(陰陽), the method of Chon Gu Jin(寸口診) is developed by chon Gu Jin(寸口診). 5) What Chuk Kwan Chon Jin(寸關尺診) is that area of the Chon Gu(寸口) are divided fot three point, we can diagnose. By consulting Sam Bu Gu Who Jin(三部九候診), developping of the method of acupunture, utilzing the theory of five element(五行) it is devised by concentrating way of thinking of the method mac Jin(脈診) exiting. 6) Chon Kwan Chuk Jin MaC(寸關尺診脈) begin from Nae Kyoung(內徑) exiting. After Nan Kyoung(內徑), spread out widely from Mac Kyoung(脈診) of Wang Suk wha(王叔和), the future medicins followed it. Yang Hyun Jo(楊玄操) and established Chon Kwan Chuk Jin(寸關尺診) which is used widely today. This right and left Chon Kwan Chuk Jin(寸關尺診), we call it method of Yuk Bu Jung Wee Jin Mac(六部定位診脈). 7) We can think the base which presume the arrangement of the viscera for Chon Kwan Chuk(寸關尺) of the right and the left. 8) The origin, which seperate the right and the left of Mac(脈), is showed at the treory of Ji Jin Yo Dae(至眞要大論) in So Mun(素問) which Chon Chuk(寸尺) seperate the right and the left. But the method of diagnosis in Nan Kyoung(難經) have no seperation the fight and the left. Otherwise this. there is clearly writtened the seperation for the right origin of the method of Yuk Bu Jung Wee Jin Mac(六部定位診脈) seek for Cang Gong(倉公). 9) Yang Hyun Jo(楊玄操) notice that the Chuk(尺) is mentioned for Sam Cho(三焦) in the method of Mac Kyuong(脈經), Sim Po Kyung(心包經) which put together with Sam Cho(三焦) allot on this, he had established the method of Yuk Bu Jung Wee Jin Mac(六部定位診脈). 10) On the method of Paen Jak Yin Yang Mac(扁鵲陰陽脈) in Mac Kyoung(脈經), equal article exist with the theory of Pyung In Kee Sang(平人氣象論) in So Mun(素問). When Wang Suk Wha(王叔和) write Mac Kyung(脈經), we can presume that the book of Mac(脈) which Paen Jak(扁鵲) had experienced the origin have exited besides So Mun(素問), Young Chu(靈樞). If so he must be make Chon Kwan Chuk Jin(寸關尺診) very fairly standard. So Nae Kyoung(內經), which must be fllowed the method of Paen Jak Mac(扁鵲脈), do the method diagnosis of Chon Kwan Chuk(寸關尺), diagnise of disease and treat.

  • PDF

한국의 세계기록유산 보존 현황 및 과제 (Preservation of World Records Heritage in Korea and Further Registry)

  • 김성수
    • 한국기록관리학회지
    • /
    • 제5권2호
    • /
    • pp.27-48
    • /
    • 2005
  • 이 논문은 한국의 세계기록유산에 대하여 먼저 그 의미와 가치를 재확인하고, 이들 세계기록유산에 대한 보존 관리 및 그 현황을 조사하며, 한국의 기록유산을 디지털화 하는데 있어서의 문제점과 해결책을 모색하고, 추후 한국의 기록유산 중 세계기록유산으로 등록되기를 희망하는 4종의 기록물들에 대한 가치와 의의를 고찰한 연구이다. 본 연구의 상세 사항은 다음과 같다. 첫째, 제2장에서는 한국의 세계기록유산에 대한 가치와 의의를 고찰하였다. 먼저 세계기록유산의 선정기준과 절차 등을 먼저 파악하고, 한국의 세계기록유산인 "훈민정음" "조선왕조실록" "승정원일기" "직지(백운화상초록불조직지심체요절(白雲和尙抄錄佛祖直指心體要節))"에 대하여 각각 그 가치와 의미를 분석하였다. 둘째, 제3장에서는 '한국의 세계기록유산 보존 관리 현황'에서는 세계기록유산을 보존하고 있는 <서울대학교 규장각> <국가기록원 부산기록정보센터> <간송미술관>의 기관별로 그 보존 관리 현황을 고찰하였다. 그 결과, 이 3기관 모두 세계기록유산 보존 관리 현황은 '매우 우수하다'고 평가할 수 있었다. 즉, 1)그 세부적인 보안대책이 완벽하다. 2)그 보존방법에 있어서도 항온 항습의 특별한 서고를 별도로 마련하고, 이 서고 내에서 다시 '오동나무 상자 서장(書欌)'을 설치한 후, 이들 상자와 서장 속에 세계기록유산을 납입하여 보존하고 있다. 3)방화장치와 서고조명 및 소독 등에도 철저를 기하고 있음 등을 파악하였다. 셋째, 제4장에서는 '한국의 기록유산 디지털화 과제'에 대하여 개괄적으로 고찰하였다. 그 결과, 한국 기록유산의 디지털작업 및 DB구축에서 '디지털화 표준'이 가장 중요한 문제이며, 이 문제의 해결을 위해서는 디지털화(Digitization)에 대한 총체적이고 표준적인 시스템의 개발이 시급함을 지적하였다. 그리고 국가기록관리시스템을 개발한 경험이 있는 <국가기록원>과 한국학 고기록물의 디지털화에 많은 관심을 가진 <문화재청>이 공동으로 노력하여, 한국학 관련 기록유산의 디지타이제이션(Digitization)에 대한 총체적이고 표준적인 시스템의 개발이 요구됨을 파악하였다. 넷째, 제5장 '세계기록유산 등록을 추후 희망하는 한국의 기록유산'에서는 한민족의 기록유산 중에서 차후 세계기록유산으로 등재되기를 희망하는 4종 즉, 1)<해인사 고려대장경 경판>, 2)"동의보감", 3)"삼국유사", 4)"무구정광대다라니경"의 기록물에 국한하여, 그 어떤 의미에서 세계적인 가치와 의의가 있는가를 고찰하였다.

민담 '주인집을 망하게 한 하인'의 분석심리학적 이해: 트릭스터 원형을 중심으로 (An Interpretation of the Folktale 'the Servant Who Ruined the Master's House' from the Perspective of Analytical Psychology: Centering on the Trickster Archetype)

  • 노명선
    • 심성연구
    • /
    • 제37권2호
    • /
    • pp.184-254
    • /
    • 2022
  • 본 논문을 통해 한국 민담 '주인집을 망하게 한 하인'의 심리학적 의미를 고찰하였다. 민담 속 주인과 하인의 대립은 보편적인 인간 정신의 문제로, 경화된 기존의 집단적 의식과 이를 보상하고 갱신하려는 새로운 의식의 대립으로 볼 수 있다. 다른 각도에서 설명해보자면 인간의 정신적인 측면과 본능적인 측면 사이의 혹은 의식과 무의식 사이의 대립이며, 자아와 그림자 사이의 대립이라고도 할 수 있다. 민담 속 주인은 애먹이는 막내 하인을 없애버리려 여러 차례 시도하지만, 하인은 꾀와 속임수를 써서 주인으로부터 음식과 말(馬), 막내 누이, 전 재산, 마침내 목숨까지 빼앗아 버리고, 이야기는 막내 하인과 막내 누이의 혼인 생활로 끝을 맺는다. 주인이 죽고 하인이 새로운 주인이 되는 대극반전(enantiodromia)은 낡은 집단적 의식이 파괴되고 집단적 무의식으로부터 올라온 새로운 의식이 지배적 위치에 서게 되는 것으로, 개인의 심리적 상황에서는 기존의 자아의 태도가 해소되고 새로운 태도로 변환되는 것으로 이해해볼 수 있다. 이야기의 중간 과정에서 하인은 그를 죽이려고 주인이 써준 등편지를 순박한 사람들을 이용해 새롭게 바꿔 써서 막내 누이와 혼인한다. 이 모습은 집단적 의식의 도덕관념에서는 부정적으로 이해될 수 있으나, 아낙네, 꿀장수, 배고픈 중으로 상징되는 조선 시대 집단적 의식에서 무시되어오던 정신요소를 통합하는 과정으로 볼 수 있다. 하인으로 대변되는 새로운 의식성은 기존의 틀에 구속받지 않는 트릭스터적 특성을 갖기에 집단적 의식에서 무시되어온 정신적 내용을 통합하여 조선 후기 집단적 의식에 대한 보상과 대안으로서 제시하는 요소라고 할 수 있다. 주인은 다시 하인을 죽이려고 하인을 가죽 부대에 넣어 나무에 매다는데, 가죽 부대 속에 들어가 매달렸더니 눈을 떴다는 하인의 속임수에 넘어간 소경이 대신 매달려 죽고 하인은 달아나게 된다. 주인과 하인의 대극 문제가 마침내 나무로 상징되는 전체 정신(Self)에 맡겨지자 소경이 제거되는 것은 트릭스터에 포함되어있는 맹목성, 어리석음, 탐욕적 요소를 구분하고 정화하려는 자기(Self)의 의도로 이해해볼 수 있다. 이런 과정들을 거쳐 집단적 의식의 새로운 변화 혹은 새로운 자아의 태도를 상징하는 하인은 기존의 문제들을 해결하고 주인의 자리에 서게 된다. 그러나 꾀 많은 하인의 활약상을 들으며 청중들은 유쾌함과 해방감을 느끼는 한편, 소경이 대신 죽고 주인집 식구가 몰살되고 하인이 주인이 되는 부분에서는 하인의 위험성과 통제 불가능에 대한 우려와 두려움의 감정을 경험하기도 한다. 해외 유화들에 등장하는 트릭스터들 역시 철저히 이기적이고 오직 욕구를 채우고 위험에서 빠져나가기 위해 무고한 존재들을 속이거나 죽게 만드는데, 이들 트릭스터를 처단하거나 교화하려는 노력은 허사로 돌아가고 그들은 달아나버린다. 그러므로 본 민담 역시 이런 원형적 그림자가 매우 위험하다는 것, 그리고 의식이 통제하거나 의식에 동화될 수 없다는 것을 알게 해주고, 그것을 외경하고 관조하도록 하는 목적 의미도 있다고 볼 수 있다. 트릭스터는 기존의 구조와 질서가 경화되었을 때 보상작용으로서 무의식으로부터 올라오는 재생시키는(revivifying) 자연 에너지의 비합리적 발현 양상이다. 그 현상은 기존의 집단적 정신의 입장에서는 파괴적이고 비도덕적일 수 있으나, 도덕적으로 규정할 수 없는 보다 근원적 정신인 집단적 무의식의 기능이라고 보아야 한다. 트릭스터 원형상으로 볼 수 있는 하인은 변환을 가져오는 존재로 파괴성과 창조성이라는 양면성과 모순성을 지니고 있다. 본 민담의 유화들의 결말은 여러 갈래인데 이는 트릭스터의 양면성으로 인해 청중의 마음 반응이 그만큼 다양하다는 것을 반영하며, 트릭스터 문제에 대한 무의식의 다양한 반응을 제시하는 것이기도 하다. 또한 트릭스터란 그만큼 결론이 안 나고 논란을 일으키는 모순덩어리 존재로 의식적 합리적 태도로 통제할 수 없다는 것, 우리 안의 트릭스터 원형에 대해 진지하게 관조할 수 있을 뿐이라는 것을 보여준다.

비결핵항산균증 전국 실태조사 (National Survey of Mycobacterial Diseases Other Than Tuberculosis in Korea)

  • 대한결핵 및 호흡기학회 학술위원회
    • Tuberculosis and Respiratory Diseases
    • /
    • 제42권3호
    • /
    • pp.277-294
    • /
    • 1995
  • 연구 배경: 우리나라에서 과거 30년 동안 결핵 유병률은 현저히 감소되어 왔으나 비결핵항산균에 의한 질병의 발생빈도는 아직 정확하게 알려져 있지 않다. 대한결핵 및 호흡기학회는 전국 실태조사를 통하여 현재까지 확인된 전국의 비결핵항산균증 발생 현황을 파악하고 이를 분석하여 외국의 보고와 비교함으로써 일반 개업의 및 내과 전문의의 진료 활동에 도움이 되도록 하고자 본 사업을 시행하였다. 방법: 조사와 분석은 1981년 1월부터 1994년 10월까지 대한결핵협회 결핵연구원에 의뢰된 검체중 비결핵항산균의 종(species)이 확인된 158예를 대상으로 검사를 의뢰한 병원의 진료의에게 증례 기록지를 보내어 정확한 임상 및 검사 정보를 기록하여 회신 하도록하는 후향적 조사 방법으로 그 결과를 수집 분석하였다. 결과: 1) 연도별로 보면 1981년에 1예, 1982년 2예 등으로 1990년 이전에는 매년 10예 미만 이던 것이 1991년에 14예, 1992년 10예, 1993년 4예, 1994년에는 96예로 1990년 이후가 전체의 84.2%를 차지하였다. 2) 연령은 10대 1예, 20대 6예, 30대 15예, 40대 19예, 50대 27예, 60대 51예, 70세 이상 39예로 60세 이상이 전체의 57%를 차지하였다 성별 분포는 남자 114예(72.1%), 여자 44예(27.9%) 이었다. 3) 병원별 분포는 복십자의원 61예(38.6%), 보건소 42예(26.6%), 3차기관 21예(13.3%), 2차기관 15예(9.5%), 1차기관 10예(6.3%) 이었으며, 지역별 분포는 서울 98예(62%), 경상북도 17예(10.8%), 경기도 12예(7.6%), 충청남도 8예(5.1%), 경상남도와 충청북도 각각 5예(3.2%), 기타 지역이 6예(3.8%) 이었다. 4) 선행 폐 질환은 폐결핵 113예(71.5%), 기관지확장증 6예(3.8%), 만성 기관지염 10예(6.3%), 폐섬유증 6예(3.8%) 등이었다. 폐결핵의 발병 시기는 1년 이내가 7예(6.2%), 2~5년전 32 예(28.3%), 6~10년전 29예(25.7% ) 등으로 2~10년전이 전체의 54%를 차지하였다. 폐결핵의 치료 기간은 3개월 이내가 6예로 5.3%이었으며, 4~6개월이 17예(15%), 7~9개월 16예(14.2%), 10~12 개월 11예(9.7%), 1~2년 21예(18.6%), 2년 이상 8예로 7.1% 이었다. 폐결핵의 치료 결과는 완치가 44예(38.9%), 치료 설패가 25예(22.1%) 이었다. 5) 동반된 폐외질환은 만성 간질환과 만성 산부전이 함께 있었던 경우 각각 1예를 포함하여 당뇨병이 9예(5.7%)에서 있었으며, 심혈관계질환 2예(1.3%), 장기간 스테로이드를 투여 받은 경우 2예(1.3%) 그리고 만성 간질환, 만성 신부전, 대장염 및 진폐증이 각 1예(0.6%)씩 있었다. 6) 비결핵항산균증이 발현한 임상상은 만성 폐 감염증 86예(54.4%), 경부 및 기타 임파선염 1예(0.6%), 기관지 결핵 3예(1.9%), 장결핵 1예(0.6%) 이었다. 7) 임상 소견은 기침 62%, 객담 61.4%, 호흡곤란 30.4%, 객혈 및 혈담 20.9%, 체중 감소 l3.3%, 발열 6.3%, 기타 4.4% 등 이었다. 8) 흉부 X-선 소견은 정상 7예(4.4%), 경증 20예(12.7%), 중등증 67예(42.4%), 중증 47예(29.8%)이었으며, 공동은 43예(27.2%)에서 동반되었고, 흉막염은 18예(11.4%)에서 동반되었다. 9) 비결핵항산균이 확언된 검사물은 객담 143예(90.5%), 객담 및 기관지세척액 4예(2.5%), 기관지세척액 1예(0.6%) 이었다. 동정된 비결핵항산균의 종류는 M. avium-intracellulare가 104예로 전체의 65.2%를 차지하였고 M. fortuitum 20예(12.7%), M. chelonae 15예(9.5%), M. gordonae 7예(4.4%), M. terrae 5예(3.2%), M. scrofulaceum 3예(1.9%), M. kansasii와 M. szulgai가 각각 2예(1.3%), 그리고 M. avium-intracellulare와 M. terrae가 동시에 확인된 경우가 1예(0.6%) 이었다. 10) 도말 및 배양 검사 결과는 4번의 검사 중 도말 음성, 배양 양성인 경우는 첫번째 검사상 59예로 37.3%이었고, 두번째 검사에서는 22.8%, 세번째 검사에서는 15.2%, 네번째 검사에서는 14.6% 이었으며, 도말 양성, 배양 양성인 경우는 첫번째 검사상 48예로 30.4% 이었고, 두번째와 세번째 검사에서는 각각 34예(21.5%), 네번째 검사에서는 22예(13.9%)이었다. 이상의 배양 검사 결과를 종합하면 4번 검사한 것 중에서 4회 모두 배양 양성으로 확인된 경우가 21예(13.3%)이었고 3회 배양 양성은 37예(23.4%), 2회 배양 양성은 38예(24.1%)로 2번 이상 배양 양성으로 확인된 경우는 총 96예(60.8%) 이었다. 11) 모든 비결핵항산균에 대한 약제 내성률은 INH 62%, EMB 55.7%, RMP 52.5%, PZA 34.8%, OFX 29.1%, SM 36.7%, KM 27.2%, TUM 24.1%, CS 23.4%, TH 34.2%, PAS 44.9% 이었다. M. avium intracellulare에 대한 내성률은 INH 62.5%, EMB 59.6%, RMP 51.9%, PZA 29.8%, OFX 33.7%, SM 30.8%, KM 20.2%, TUM 17.3%, CS 14.4%, TH 31.7%, PAS 38.5%이었다. M. chelonae에 대한 내성률은 INH 66.7%, EMB 66.7%, RMP 66.7%, PZA 40%, OFX 26.7%, SM 66.7%, KM 53.3%, TUM 53.3%, CS 60%, TH 53.3%, PAS 66.7% 이었다. M. fortuitum 에 대한 내성률은 INH 65%, EMB 55%, RMP 65%, PZA 50%, OFX 25%, SM 55%, KM 45%, TUM 55%, CS 65%, TH 45%, PAS 60% 이었다. 12) 비결핵항산균증의 치료는 129예(81.7%)에서 시행하였으며, 1차 치료 처방 중 INH와 RMP을 포함하는 복합 처방은 86예(66.7%) 이었고, INH 혹은 RMP 중 한가지만을 포함하는 처방은 30예(23.3%), INH와 RMP이 포함되지 않은 처방은 9예(7%)에서 있었다. 2차 치료를 시행한 65예의 처방은 2제 이하 2예(3.1%), 3제 15예(23.1%), 4제 20예(30.8%), 5제 9예(13.8%), 6제이상 19예(29.2%) 이었다. 치료 후 경과는 36예(27.9%)에서 호전, 65예(50.4%)에서 변화 없었으며, 4예(3.1%)에서 악화 4예(3.1%)에서 사망하였다. 호전된 경우 34예(94.4%)에서 균 음전이 확인되었으며, 균 음전 시기는 1개월 이내 2예(5.9%), 3개월 이내 11예(32.4%), 6개월 이내 14예(41.2%), 1년 이내 2예(5.9%), 1년 이상 1예(2.9%) 등 이었다. 결론: 비결핵항산균증 전국실태조사 결과 아직 우리나라에서 확인된 비결핵항산균 감염 예가 많지 않으나 1990년 이후 비결핵항산균증이 현저히 증가하는 경향이었으므로 앞으로 이에 대한 임상의들의 관심이 더욱 필요하리라 생각된다.

  • PDF

$^{51}Cr$을 사용(使用)한 장관내(賜管內) 출혈량측정법(出血量測定法) (The Use of Radioactive $^{51}Cr$ in Measurement of Intestinal Blood Loss)

  • 이문호
    • 대한핵의학회지
    • /
    • 제4권1호
    • /
    • pp.19-26
    • /
    • 1970
  • 서론(緖論) 위장관내(胃腸管內)의 출혈(出血)의 유무(有無)를 진단(診斷)한다는 것은 임상적((臨床的)으로 대단(大端)히 중요(重要)하며 잠혈반응(潛血反應)은 임상검출법(臨床檢出法)의 하나로 많이 이용(利用)되고 있다. 잠혈반응(潛血反應)에 사용(使用)되는 각종화학반응(各種化學反應)은 그 검출법(檢出法)이 비교적(比較的) 간편(簡便)하되 출혈량(出血量)을 추정(推定) 하는것은 곤란(困難)하여 정성반응(定性反應)의 영역(領域)을 벗어나지 못하고 있다. 특(特)히 우리라라에는 소화관내(消化管內)의 출혈(出血)을 야기(惹起)하기 쉬운 위궤양(胃潰瘍), 십이지장궤양(十二指賜潰瘍) 내지(乃至) 위암(胃癌)과 같은 각종(各種) 질환(疾患)의 이환율(罹患率)이 많을 뿐만 아니라 십이지장충(十二指腸蟲) 감염자(感梁者)가 많아 출혈량(出血量)의 측정(測定)은 각종질환(各種疾患)의 치료방침(治療方針) 내지(乃至) 예후(豫後)를 결정(決定)하는데 대단(大端)히 중요(重要)하다. 최근(最近) 방사성(放射性)$\ulcorner$크롬$\lrcorner$($^{51}Cr$)으로 표지(標識)된 적혈구(赤血球)를 정주(靜注)한 후(後) 대변내(大便內)에 배설(排泄)되는 방사능(放射能)을 측정(測定)하여 말초혈액단위량내(末消血液單位量內)의 방사능(放射能)과 비교(比較)하여 소화관내(消化管內)의 출혈량(出血量)을 측정(測定)하는 연구(硏究)가 보고(報告)되고 있다. 저자(著者)는 출혈량(出血量)이 적혈구수명측정(赤血球壽命測定)에 미치는 영향(影響)을 관찰(觀察)하는 예비실험(豫備實驗)의 하나로 종래(從來) $^{51}Cr$를 사용(使用)한 소화관내(消化管內)의 출혈량측정법(出血量測定法)에 대(對)한 몇가지 기초적(基礎的) 연구(硏究)를 시도(試圖)하여 $^{51}Cr$법(法)의 신빙성여하(信憑性如何)를 검토(檢討)한 바 있어 이에 보고(報告)하는 바이다. 실험방법(實驗方法) 및 실험대상(實驗對象) I) 방사성(放射性)$\ulcorner$크롬$\lrcorner$($^{51}Cr$)과 적혈구(赤血球)의 표지법(標識法): 원자력연구소(原子力硏究所)에서 생산(生産)된 $Na_2^{51}CrO_4$를 사용(使用)하였고 표지법(標識法)은 적혈구수명측정(赤血球壽命測定)때와 같은 방법(方法)(Gray & Sterling, Read)을 사용(使用)하였다. 정주(靜注)된 $^{51}Cr$의 배설(排泄) 및 경구투여(經口投與)한 $^{51}Cr$의 흡수도(吸收度)를 관찰(觀察)하기 위(爲)하여 다음과 같은 예비(豫備) 실험(實驗)을 하였다. $^{51}Cr$로 표지(標識)된 일정량(一定量)의 적혈구(赤血球)를 Levine tube를 사용(使用)하여 피검자(被檢者)의 십이지장부위(十二指腸部位)에 정확(正確)히 전량(全量)을 주입(注入)시킨다음 tube속의 $^{51}Cr$ 방사능(放射能)을 없애기 위하여 약 100ml의 수도(水道)물로 세척(洗滌)한다음 24시간(時問) 후(後)부터 대변(大便), 뇨(尿) 및 혈액(血液)을 매일채취(每日採取)하여 $^{51}Cr$의 방사능(放射能)을 측정(測定)하여 투여(投與)한 $^{51}Cr$에 대(對)한 백분률(百分率)을 산출(算出)한다. 대변(大便) 및 뇨(尿)의 채취(採取)는 그속의 방사도(放射度)를 측정(測定)할 수 없을때 까지 실시(實施)한다(대량(大略) $7{\sim}10$일간(日問)). 수집한 대변(大便)은 $900{\sim}1,000^{\circ}C$의 전기로(電氣爐)속에서 소각 하여 완전탄화(完全灰化)시킨다음 일정량(一定量)의 증류수(蒸溜水)로 희석(稀釋)한 다음 well형(型) scintillation counter로 $^{51}Cr$의 방사도(放射度)를 계측(計測)하고 혈액량(血液量)으로 환산(換算)한다. 뇨(尿는) 24시간(時間) 뇨(尿)를 전부(全部) 축뇨(蓄尿)한 다음 $3{\sim}5ml$의 시료(試料)를 채취(採取)하여 방사도(放射度)를 측정(測定)하고 1일(日) 뇨중(尿中)의 $^{51}Cr$ 배설량(排泄量)을 계산(計算)하는 한편(便) 혈액량(血液量)으로 환산(換算)한다. 혈액량(血液量)의 측정(測定): 적혈구수명측정(赤血球壽命測定)때와 같은 방법(方法)으로 처리(處理)하여 정주(靜注)한 후(後) 10분(分) 20분(分) 내지(乃至) 30분(分) 후(後)에 heparin을 첨가(添加)하여 $2{\sim}4ml$가량(可量) 채혈(採血)하고 그 방사도(放射度)를 측정(測定)하여 그 평균치(平均値)를 구(求)한다. 실험성적(實驗成績) $^{51}Cr$의 대변(大便) 및 뇨중(尿中) 배설(排泄)을 관찰(觀察)하는 한편 투여(投與)한 혈액량(血液量)($^{51}Cr$로 표지(標識)된)과의 상호관계(相互關孫)도 아울러 고찰(考察)할 목적(目的)으로 투여혈액량(投與血液量)을 달리하는 조건하(條件下)에 실시(實施)한 성적(成績)을 보면 다음과 같다. 즉(卽) 1) $^{51}Cr$표지적혈구(標識赤血球)의 경구투여후(經口投與後)의 대변(大便) 및 뇨중(尿中)에의 $^{51}Cr$ 회수율(回收率) 및 배설률(排泄率) : $^{51}Cr$표지적혈구(標識赤血球) 5ml, 10ml, 15ml 및 20ml를 각각(各各) 잠혈반응(潛血反應)이 음성(陰性)인 정상(正常) 건강인(健康人) 3명(名) 내지(乃至) 5명(名)에게 십이지장관내(十二指腸管內)에 주입(注入)한 후(後)의 대변내(大便內)의 $^{51}Cr$ 회수율(回收率)과 장관내흡수율(腸管內吸收率)(뇨중배설량(尿中排泄量)을 보면 Table 1, 2 및 3에서 보는 바와 같다. 즉(卽) 5 ml식(式) 주입(注入)한 검사군(檢査群)(A)에서는 대변내(大便內)의 $^{51}Cr$ 회수율(回收率)은 $85.7{\sim}90.7%$, 평균(平均) 87.8%이고 뇨중배설량(尿中排泄量)은 $0.5{\sim}1.2%$, 평균(平均) 0.8%로 총회수율(總回收率)은 $86.7{\sim}91.4%$, 평균(平均) 88.5%이었고 10ml식(式) 주입(注入)한 검사군(檢査群)(B)에서는 대변(大便)속의 $^{51}Cr$ 회수율(回收率)은 $87.5{\sim}92.5%$, 평균(平均) 90.0%, 뇨중배설량(尿中排泄量)은 0.5-1.5%, 평균(平均) 0.9%로 총회수율(總回收率)은 88.2%{\sim}94.0%, 평균(平均) 90.9%이었다. 한편(便) 15ml 내지(乃至) 20ml식(式) 투여(投與)한 검사군(檢査群)(C)에서 는 대변(大便)속의 $^{51}Cr$회수율(回收率)은 89.7{\sim}97.7%, 평균(平均) 94.3%, 뇨중배설량(尿中排泄量)은 0.5{\sim}1.2%, 평균(平均) 0.8%로 총회수율(總回收率)은 95.1%이었다. 2) $^{51}Cr$표지적혈구(標識赤血球)의 정주후(靜注後)의 장관내배설(賜管內排泄) : $^{51}Cr$표지적혈구(標識赤血球)를 정주(靜注)하면 $^{51}Cr$의 대부분(大部分)은 뇨중(尿中)으로 배설(排泄)됨이 알려져 있으나 그 이외(以外)의 배설경로(排泄經路)에 관(關)하여는 그다지 알려져 있지 않다. 잠혈반응(潛血反應)이 음성(陰性)인 정상건강인(正常健康人) 5례(例)에게 $^{51}Cr$표지적혈구(標識赤血球) 15ml를 정맥주사(靜脈注射)한 후(後) 경시적(經時的)으로 타액(唾液), 위액(胃液), 십이지장액(十二指腸液) 및 대변(大便)을 채취(採取)하였다. 타액(唾液), 위액(胃液) 및 십이지장액(十二指腸液)(A- 담즙(膽汁) 및 B- 담즙(膽汁)으로 구별(區別)하였음)을 각각(各各) $2{\sim}5ml$식(式) 채취(採取)하였고 대변(大便)은 $4{\sim}5$일간(日間)(변비시(便秘時)에는 $7{\sim}10$일간(日間)까지)채취(採取) 전기로(電氣爐)로 회화(灰化)하여 각각(各各) 그의 방사능(放射能)을 계측(計測)하였고 대변(大便)속의 $^{51}Cr$방사도(放射度)는 혈액량(血液量)으로 환산(換算)하였으며 그 성적(成績)은 Table 4에서 보는바와 같다. 즉(卽) 타액(唾液)이나 B-담즙(膽汁)속에서는 거의 $^{51}Cr$방사능(放射能)을 발견(發見)할 수 없었는데 반(反)하여 위액(胃液) 및 담즙(膽汁) A속에서는 정주(靜注) $1{\sim}2$일(日) 이내(以內)에 약간(若干)의 방사능(放射能)을 검출(檢出)할 수 있었다. 한편 대변(大便)속에서는 1일(日) 0.5 내지(乃至) 1.5ml의 혈액(血液)에 해당되는 $^{51}Cr$의 방사능(放射能)을 관찰할 수 있었으며 이 정도(程度)(평균(平均) 0.9ml/혈액(血液)/일(日))의 $^{51}Cr$의 변중(便中) 출현(出現)은 진성출혈(眞性出血)과는 무관(無關)한 것으로 생각된다. 총괄(總括) Owen 등(等)은 2필(匹)의 개에서 $Na_2^{51}CrO_4$로 표지(標識)한 적혈구(赤血球)를 위내(胃內)에 주입(注入)하여 거의 대부분(大部分)이 대변(大便)으로 배설(排泄)되는 한편(便) 정주(靜注)로 주입(注入)한 $^{51}Cr$의 대부분(大部分)은 뇨중(尿中)으로 배설(排泄)됨을 발표(發表)하였고 그 후 Roche 등(等)은 $^{51}Cr$표지적혈구(標識赤血球)를 십이지장관내(十二指腸管內)에 주입(注入)한 8례(例)에서 뇨중배설(尿中排泄)은 1.7%($0{\sim}5.3%$), 변중(便中) 회수율(回收率)은 96.7%($90.7{\sim}103.5%$), 총배설률(總排泄率)은 98.7%($91.5{\sim}105.7%$)라고 보고(報告)한바 있다. 저자(著者)의 성적(成績)을 보면 투여(投與)한 혈액량(血液量)이 많을수록 대변(大便)속의 회수율(回收率)은 높으며(Fig. 1) 대변(大便)속의 예민(銳敏)하고 높은 회수율(回收率)을 얻고저 할때에는 적어도 15ml 이상(以上)의 적혈구(赤血球)를 투여(投與)함이 타당(妥當)함을 알 수 있었다. 경구투여후(經口投與後)의 $^{51}Cr$의 위장관흡수율(胃腸管吸收率)(뇨중배설(尿中排泄))을 보면 대체(大體)로 1%이내(以內)($0.8{\sim}1.5%$)이며 투여혈액량(投與血液量)과는 무관(無關)함을 알 수 있었다. 한편(便) $^{51}Cr$의 정주후(靜注後)에는 대부분(大部分)이 뇨중배설(尿中排泄)의 경로(經路)를 취(取)하되 담관내(膽管內)의 출혈량(出血量)을 이 방법(方法)으로 계측(計測)하고저 할때에는 자관내(腸管內)의 chromium 배설유무(排泄有無)를 관찰(觀察)함이 필요(必要)하다. 잠혈반응(潛血反應)이 음성(陰性)인 정상건강인(正常健康人)에게 $^{51}Cr$표지적혈구(標識赤血球)를 정주(靜注)하였을때 대변(大便)속에서 출혈(出血)과 관계(關係)없는 $^{51}Cr$의 방사능(放射能)을 계측(計測)할 수 있으며 이때의 $^{51}Cr$의 방사능(放射能)을 혈액량(血液量)으로 산출(算出)한 연구(硏究)들이 보고(報告)되고 있다. 즉(卽) Roche 등(等)은 정상인(正常人)에서 1.27ml/d, Ebaugh 등(等)은 $0.3{\sim}2.0ml/d$, Hushes-Jones는 2ml/d이하(以下)의 출혈(出血)을 볼 수 있었다고 하고 Nakao는 1.0ml전후(前後)의 혈액(血液)에 해방되는 출혈(出血)을 보았다고 한다. 저자(著者)는 평균(平均) 0.9ml의 혈액(血液)에 해방되는 출혈(出血)과는 전연(全然) 무관(無關)한 $^{51}Cr$의 방사능(放射能)을 발견(發見)할 수 있었다. 정주투여시(靜注投與時)의 뇨중(尿中) 이외(以外)에 $^{51}Cr$배설(排泄)의 경로(經路)를 관찰하기 위하며 경시적(經時的)으로 위액(胃液), 타액(唾液) 및 십이지장액(十二指腸液)(A 및 B 담즙(膽汁)으로 구별(區別))은 채취(採取)하여 그속으로 배설(排泄)되는 $^{51}Cr$의 방사능(放射能)을 측정(測定)해본 즉 주입초기(注入初期)에 위액(胃液) 및 A담즙(膽汁)속에서 약간(若干)의 방사능(放射能)을 발견(發見)할 수 있었으며 상술(上述)한 출혈(出血)과 무관계(無關係)한 $^{51}Cr$의 사용배설(使用排泄)은 주(主)로 담즙(膽汁) 및 위액(胃液)을 통(通)한것이 아닌가 생각된다. 결론(結論) $Na_2^{51}CrO_4$를 사용(使用)하여 적혈구(赤血球)를 표지정주(標識靜注)한 후 대변(大便)속으로 배설(排泄)되는 방사능(放射能)을 측정(測定)하여 소화관내(消化管內)의 출혈량(出血量)을 측정(測定)하는 방법(方法)에 관(關)한 기초적(基礎的) 임상실험(臨床實驗)을 하여 다음과 같은 성적(成績)을 얻었다. 1. 잠혈반응(潛血反應)의 음성(陰性)인 정상건강인(正常健康人) 16례(例)에서 $^{51}Cr$표지적혈구(標識赤血球)를 경구투여(經口投與)하였을때 대변내(大便內)의 평균(平均) 회수율(回收率)은 90.7%($83.7{\sim}97.7%$)로 투여혈액량(投與血液量)이 많을수록 변중회수율(便中回收率)은 높으며 따라서 검사시(檢査時)에는 적어도 15ml이상(以上)의 혈액(血液)을 사용(使用)함이 적당(適當)하다고 생각된다. 한편(便) 이때의 뇨중(尿中) 배설(排泄)은 평균(平均) 0.8%($0.5{\sim}1.5%$)이었다. 2. $^{51}Cr$표지적혈구(標識赤血球)를 정상건강인(正常健康人)에게 정주(靜注)하였을때 $^{51}Cr$의 방사능(放射能)을 변(便)속에서 검출(檢出)할 수 있었으며 혈액량(血液量)으로 환산(換算)하여 0.9ml에 해당한다. 이 방사능(放射能)은 출혈(出血)과는 무관계(無關係)하여 주(主)로 A- 담즙(膽汁) 및 위액(胃液)으로 배설(排泄)되는것으로 생각된다. 따라서 적어도 2.0ml이상(以上)의 혈액량(血液量)에 해당되는 $^{51}Cr$의 방사능(放射能)이 있을때 임상적(臨床的)으로 의의(意義)가 있다고 본다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF