• Title/Summary/Keyword: climate system

Search Result 2,598, Processing Time 0.024 seconds

A Study on the Indoor Thermal Comfort of the House with Ondol Heating System of Korean Traditional Housing (전통온돌난방의 실내 온열환경 쾌적감 평가에 관한 연구)

  • Kang, Sang-Woo;Jeon, Ji-Hyeon;Kook, Chan
    • Journal of the Korean housing association
    • /
    • v.18 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • The principle of Korean Traditional Housing was to be harmonized with the nature with shapes according to regional climate and materials easily available from the region. These environmentally friendly characteristics protected indoor environment from climate changes. The characteristics of Korean traditional housing to control indoor environment would be very useful for contemporary housing in that current issues, improving housing amenity and wellbeing, had basic goals same with what Korean Traditional Housing had. Though it could be found characteristics of indoor thermal environment heated by Ondol Heating System, analyses of evaluation made by occupants of the rooms were insufficient because most of the studies had been focused on the measurement of indoor thermal factors. Thus, with an evaluation of occupants for the indoor thermal comfort and an estimation of discomfort derived from the result of vertical temperature distribution, it was studied whether the agreeable indoor range of rooms, of which was Jeonju Hanok Living Experience Center, heated by Ondol Heating System corresponded to the agreeable indoor range presented in references.

Optimum Collector Area and Economic Evaluation for the Greenhouse Heating (태양열 온실 난방에 대한 최척 집열 면적과 경제성 평가)

  • Pak, Ee-Tong;Kim, Kyu-In
    • Solar Energy
    • /
    • v.2 no.1
    • /
    • pp.49-58
    • /
    • 1982
  • Aim of this study was to obtain the heating performance and the economic evaluation on solar heating system for greenhouse which area of floor was $90m^2$. For heating performance effective solar energy for the greenhouse was compared with overall heating loads including coefficient of heat transfer and conduction. And the economic evaluation solar heating system was evaluated by comparison its initial investiment costing with oil saving cost. Initial investiment costing included collector cost, storage cost, piping cost, control system cost and miscellaneous costs which included pumps, motors etc. The contents of this study included the survey of climate conditions for solar heating, long-term collector performance and optimum collector area of solar heating system in existing greenhouse. The results are follows: 1. Average horizontal radiation during winter was $2,434Kcal/m^2$ day which was the highest value in this country, so the climate conditions of Suwon was suitable for solar heating. 2. Resulting calculation of the optimum collector area was $30m^2$ and the solar energy accounted for 30% of the overall heating load. 3. The capacity of storage tank required 60 liter per unit area ($m^2$) of solar collector.

  • PDF

Economic Analysis of High-tech Glass Greenhouse through the Convergence of New Renewable Energy -Focusing on the Convergence of Geothermal and Solar Power- (신.재생에너지 융합을 통한 첨단 유리온실의 경제성 분석 -지열과 태양광 융합을 중심으로-)

  • Chung, Jong-Hwa;Yoon, Sung-Yi
    • Korean Journal of Organic Agriculture
    • /
    • v.22 no.4
    • /
    • pp.593-610
    • /
    • 2014
  • The whole world concentrates on the reduction of greenhouse gas to effectively cope with policy toward global climate change. To effectively react to climate change, even the agricultural sector requires construction of new farming systems that utilizes new and renewable energy because of rising oil prices and regulations for greenhouse gas emissions. For this reason, we need to fuse the new and renewable energy with the horticulture sector of which the light and heat energy cost accounts for great part, moreover, efforts and researches should me done which can increase income of farmers through reducing carbon dioxide and energy cost in agricultural production expenses. Therefore, this study analyzes economic feasibility and applicability of fusing geothermal heat pump and solar power facilities with high-tech glass greenhouse. As a result, it is concluded that there surely are an applicability and economic feasibility if we apply new development system that can be an alternative for problems of securing premises of existing geothermal heat pump and the RPS system as a power generation company in case of solar power. Therefore, using this analysis data, if new empirical studies fusing and implementing agriculture sector with new and renewable energy fields proliferate and be applied to actual rural and agricultural field, it will increase actual income and will become a new advanced agricultural system that effectively deals with world-wide environmental problems.

Future Change Using the CMIP5 MME and Best Models: II. The Thermodynamic and Dynamic Analysis on Near and Long-Term Future Climate Change over East Asia (CMIP5 MME와 Best 모델의 비교를 통해 살펴본 미래전망: II. 동아시아 단·장기 미래기후전망에 대한 열역학적 및 역학적 분석)

  • Kim, Byeong-Hee;Moon, Hyejin;Ha, Kyung-Ja
    • Atmosphere
    • /
    • v.25 no.2
    • /
    • pp.249-260
    • /
    • 2015
  • The changes in thermodynamic and dynamic aspects on near (2025~2049) and long-term (2075~2099) future climate changes between the historical run (1979~2005) and the Representative Concentration Pathway (RCP) 4.5 run with 20 coupled models which employed in the phase five of Coupled Model Inter-comparison Project (CMIP5) over East Asia (EA) and the Korean Peninsula are investigated as an extended study for Moon et al. (2014) study noted that the 20 models' multi-model ensemble (MME) and best five models' multi-model ensemble (B5MME) have a different increasing trend of precipitation during the boreal winter and summer, in spite of a similar increasing trend of surface air temperature, especially over the Korean Peninsula. Comparing the MME and B5MME, the dynamic factor (the convergence of mean moisture by anomalous wind) and the thermodynamic factor (the convergence of anomalous moisture by mean wind) in terms of moisture flux convergence are analyzed. As a result, the dynamic factor causes the lower increasing trend of precipitation in B5MME than the MME during the boreal winter and summer over EA. However, over the Korean Peninsula, the dynamic factor causes the lower increasing trend of precipitation in B5MME than the MME during the boreal winter, whereas the thermodynamic factor causes the higher increasing trend of precipitation in B5MME than the MME during the boreal summer. Therefore, it can be noted that the difference between MME and B5MME on the change in precipitation is affected by dynamic (thermodynamic) factor during the boreal winter (summer) over the Korean Peninsula.

Planning of Neighborhood Parks for the Disaster Prevention in Jecheon City (제천시의 방재형 도시 근린공원 조성 계획)

  • Lee, Ai-Ran
    • Ecology and Resilient Infrastructure
    • /
    • v.2 no.4
    • /
    • pp.296-304
    • /
    • 2015
  • The rapid increase in the number of climate disasters combined with the scale of change and the diversification of natural disasters require a radical solution. In particular, the urban space is more complex, therefore we need to establish measures for disaster response and how to react to damaged infrastructure based on the phenomenon of an increase in the urban population and the impermeable layer being extended. The social problems related to the economic burden of land purchase and the securing of a disaster prevention system can be solved simultaneously by introducing the park system for disaster reduction into the public land of the green space in the city. The local government has recently adapted diverse systems of disaster mitigation and carried out pioneer projects according to the guidelines for the construction of the urban park for disaster prevention published by the Ministry of Land, Infrastructure and Transport. The purpose of this study is to propose a composition model for neighborhood parks to prevent disaster through urban green spaces which has the functions of water management and biotope conservation. The result of this study will contribute to utilize the climate change adaptation model for living area neighborhood parks in the existing urban structure.

Simulation and Analysis of Solar Radiation Change Resulted from Solar-sharing for Agricultural Solar Photovoltaic System (영농형 태양광 발전 솔라쉐어링에 따른 하부 일사량 변화의 해석 및 분석)

  • Lee, Sang-ik;Choi, Jin-yong;Sung, Seung-joon;Lee, Seung-jae;Lee, Jimin;Choi, Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.5
    • /
    • pp.63-72
    • /
    • 2020
  • Solar-sharing, which is an agricultural photovoltaic system installing solar panels on the upper part of crop growing field, has especially drawn attention. Because paddy fields for cultivating crops are large flat areas, there have been various attempts to utilize solar energy for solar photovoltaic as well as growth of crops in agriculture. Solar-sharing was first proposed in Japan, and has been actively studied for optimization and practical uses. The domestic climate differs from the climate conditions in which the solar-sharing has been widely studied, therefore, it is required to develop the solar-sharing technology suitable for the domestic climate. In this study, a simulation model was developed to analyze the change of solar radiation resulted from the solar-sharing installation. Monthly solar illumination intensity and the change of illumination intensity according to the various conditions of solar panel installation were simulated. The results of monthly illumination analysis differed by altitude of the sun, which was related to season. In addition, it was analyzed that the monthly illumination decreased by up to 42% due to solar-sharing. Accordingly, it is recommended that solar-sharing should be installed as a way to maximize the efficiency of solar photovoltaic system while minimizing the decrease in solar radiation reaching the crops.

A study on the relationship between job stress and subjective symptoms associated with musculoskeletal disorders of the financial working woman's (금융직 여성 근로자의 직무스트레스 실태와 근골격계질환 자작증상과의 관련성 연구)

  • Cho, Ki-Hong;Choi, Soon-Young;Park, Dong-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.4
    • /
    • pp.17-28
    • /
    • 2007
  • This study tried to identify the job stress characteristics of female bank workers and the relationship between their stress and symptoms associated with musculoskeletal disorders(MSDs). The total number of 587 female bank tellers have been participated in this study. Specifically, questionnaire surveys regarding job stress and MSDs symptoms were conducted. On the basis of the results from the survey using Korean version of job stress questionnaire with 24 questions, stress scores associated with job requirement and job flexibility were relatively high. The job stress levels regarding job demand, organizational system, occupational climate at the work place were relatively high for the full time workers while the job stress levels regarding insufficient job control, job stability, interpersonal conflict, lack of reward were relatively high for the part time worker. The workers with longer total work years had relatively high job stress associated with interpersonal conflict, and organizational system while the workers with longer work years at the current job had relatively high job stress associated with occupational climate. Also, the workers with longer working hours a day had relatively high job stress associated with job demand, interpersonal conflict, organizational system, and occupational climate. According to the relationship identified in this study, symptoms at the neck, shoulder, hand, low back. leg were associated with the stress levels in terms of job flexibility, interpersonal conflict, job requirement, job stability. In conclusion, female bank workers are exposed to job stress due to their specific job characteristics and there has been certain relationships between their job stress and MSDs symptoms.

Examination of Factors Influencing Urban Higher Temperature using E-GIS DB (E-GIS DB를 활용한 도시 고온화 영향인자 검토)

  • Kim, Keum-Ji;Yoko, Kamata;Lee, Jung-Jae;Yoon, Seong-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.44-49
    • /
    • 2009
  • In this study, we performed urrban climate simulation how both the factor of environmental land and artificial factors influence on the formation of urban temperature. With deducing quantitative data, this study could get more accurate results of the urban temperature using urban climate simulation system. In the case of natural land cover, it appeared that there are effects on the lowering temperature and the lower temperature rate appeared in the water land cover on the whole. This is considered as temperature in water land was low because of the characteristics of water land having evaporation latent heat was high and convective sensible heat was low. In case of building which has building coverage ratio, 5% with 10 floors and building coverage ratio, 15 % with 6 floors, it appears that the temperature in the water land is $33.6^{\circ}C$. In case of building coverage ratio 5%, temperature dropped when buildings has more than 4 stories. This is regarded as the size of building is bigger, the temperature dropped in relatively because of the fluctuation of the rate of solar heat from the land. At the present time, the urban temperature are higher because of various artificial factors in the city. With these results, this study supposed to be a basies of the future studies for considering both the composition of building coverate ratio and floor plan.

  • PDF

Local Fine Grid Sea Wind Prediction for Maritime Traffic (해상교통을 위한 국지정밀 해상풍 예측)

  • Park, Kwang-Soon;Jun, Ki-Cheon;Kwon, Jae-Il;Heo, Ki-Young
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2009.06a
    • /
    • pp.449-451
    • /
    • 2009
  • Sea level rise and increase of the typhoon/hurricane intensity due to global warming have threaten coastal areas for residential and industrial and have been widely studied. In this study we showed our recent efforts on sea wind which is one of critical factors for safe maritime traffic and prediction for storm surges and waves. Currently, most of numerical weather models in korea do not have sufficient spatial and temporal resolutions, therefore we set up a find grid(about 9km) sea wind prediction system that predicts every 12 hours for three day using Weather Research and Forecasting(WRF). This system covers adjacent seas around korean peninsula Comparisons of two observed data, Ieodo Ocean Research station(IORS) and Yellow Sea Buoy(YSB), showed reasonable agreements and by data assimilation we will improve better accurate sea winds in near future.

  • PDF

Assessing Future Climate Change Impact on Hydrologic Components of Gyeongancheon Watershed (기후변화가 경안천 유역의 수문요소에 미치는 영향 평가)

  • Ahn, So-Ra;Park, Min-Ji;Park, Geun-Ae;Kim, Seong-Joon
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.1
    • /
    • pp.33-50
    • /
    • 2009
  • The impact on hydrologic components considering future potential climate, land use change and vegetation cover information was assessed using SLURP (Semi-distributed Land-Use Runoff Process) continuous hydrologic model. The model was calibrated (1999 - 2000) and validated (2001 - 2002) for the upstream watershed ($260.4\;km^2$) of Gyeongancheon water level gauging station with the coefficient of determination and Nash-Sutcliffe efficiency ranging from 0.77 to 0.60 and 0.79 to 0.60, respectively. Two GCMs (MIROC3.2hires, ECHAM5-OM) future weather data of high (A2), middle (A1B) and low (B1) emission scenarios of the IPCC (Intergovernmental Panel on Climate Change) were adopted and the data was corrected by 20C3M (20th Century Climate Coupled Model) and downscaled by Change Factor (CF) method using 30 years (1977 - 2006, baseline period) weather data. Three periods data of 2010 - 2039 (2020s), 2040 - 2069 (2050s), 2070 - 2099 (2080s) were prepared. To reduce the uncertainty of land surface conditions, future land use and vegetation canopy prediction were tried by CA-Markov technique and NOAA NDVI-Temperature relationship respectively. MIROC3.2 hires and ECHAM5-OM showed increase tendency in annual streamflow up to 21.4 % for 2080 A1B and 8.9 % for 2050 A1B scenario respectively. The portion of future predicted ET about precipitation increased up to 3 % in MIROC3.2 hires and 16 % in ECHAM5-OM respectively. The future soil moisture content slightly increased compared to 2002 soil moisture.