• Title/Summary/Keyword: cleaner

Search Result 677, Processing Time 0.03 seconds

Shear Bond Strength of Resin Cements on the IPS e.max Press (IPS e.max Press에 대한 수종 레진 시멘트의 전단결합강도에 관한 연구)

  • Lee, Kyung-Eun;Kim, Yu-Lee;Shin, Chang-Yong;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.311-322
    • /
    • 2010
  • The purpose of this study was to evaluate the bond strengths between IPS e.max Press and four different types of resin cements that often used for esthetic restoration. Disc shaped IPS e.max Press blocks(N=40, diameter: 12mm, thickness: 3mm) were fabricated according to the manufacture's instruction and cleaned with ultrasonic cleaner. They were embedded into an autopolymerizing acrylic resin. Fourty cylinder shaped resin block(Filtek Z350, diameter: 4.5mm, thickness: 3mm) were fabricated using a plastic tube. Each specimens were randomly divided into 4 experimental group and bonded each other using 4 different resin cements(Variolink II(light-cure), Variolink II(dual-cure), Calibra, Super-Bond C&B) according to the manufactures' recommendations. All the specimens were stored in normal saline at $37^{\circ}C$ for 24 hours before test. Universal testing machine at a crosshead speed of 1mm/min was used to evaluate the shear bond strength. The data were statistically analyzed using one-way ANOVA(P<.01). Multiple comparison was done by the Tukey HSD test. The shear bond strength of Super-Bond C&B to e.max was significantly lower than those of Calibra, Variolink II(light-cure), Variolink II(dual-cure) (P<.01). The shear bond strength of Calibra, Variolink II(light-cure), Variolink II(dual-cure) to e.max were not significantly different. The shear bond strengths of light-cure/dual-cure cement were higher than that of self-cure cement.

A Study on Changes in Indoor Air Pollution by Educational Activities -Centering on Newly-Established Elementary Schools- (교육활동에 따른 실내오염도 변화에 관한 연구 -신설 초등학교를 중심으로-)

  • Jeon, Seok-Jin
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.6 no.2
    • /
    • pp.66-90
    • /
    • 2007
  • The purpose of this study is to measure and analyze primary causes of indoor air pollution, including carbon dioxide, minute dust, and total volatile organic compounds, for each room before the beginning of a class through the time of discharge after the end of the class in general classrooms, computer rooms, and science rooms of three newly-established schools that opened in 2006, examine properties of indoor air environment in each room by educational activities at school, and determine effective management schemes; the results of this study can be summarized as follows: 1) As for implications for each item found in the mean for each place, since minute dust (PM10) was more likely to occur in time slots full of students' activities, such as a traveling class and a recess, than in the middle of a class and could be expected fully, it is necessary to make a scheme for cleaning in order to reduce minute dust within a room, for example, by usually using a vacuum cleaner indoors. 2) While carbon dioxide was expected to vary with the differences in the amount of breath between higher-graders and lower-graders in a general classroom but showed insignificant difference by grades, showing differences in pollution by four times at a maximum according to the opening of a window as expected, it is necessary to implement artificial or natural ventilation and take a positive measure, for example, by presenting a concrete ventilation scheme, in order to improve indoor air pollution at a room practice. 3) Total volatile organic compounds were found to exceed the standard by more than twice in general classrooms, science rooms, and computer rooms of the schools because of building materials, furnitures including desks and chairs, panels and boards for environment beautification, and items which could be detected even from students' clothes; while a field directly-reading tool was used, obtaining high reliability for the results, it is necessary to apply an analytical method based on process test separately for actual correct measurement if a significantly great amount of total volatile organic compounds appear as compared with other schools due to measuring expenses and consecutive measurements. 4) Since formaldehyde (HCHO) was generally found to exceed the standard in general classrooms, science rooms, and computer rooms, it is necessary to establish and operate a ventilator during a class in a computer room which requires airtightness and a science room in which an organic compound should be used for a class.

  • PDF

A Study on the Control and Exposure Assessment to Vinyl Chloride in the Factory Processing and Producing PVC Resin (일부 PVC 수지 제조 및 가공 근로자의 염화비닐 폭로 평가와 대책에 관한 조사 연구)

  • Park, D.W.;Shin, Y.C.;Lee, N.R.;Lee, K.Y.;Oh, S.M.;Chung, H.K.
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.33-42
    • /
    • 1994
  • This study was carried out to assess worker exposure to vinyl chloride monomer (VCM) and to present control measures in the factories processing and producing polyvinyl chloride (PVC) resin. The conclusion remarks are as follows. Only two personal samples in the factory ("E") processing polyvinyl chloride resin were analysed to be 27.6 ppm and 12.6 ppm, respectively. But, these concentration exceed 1 ppm, Permissible Exposure Limits (PEL) of OSHA. So, worker's exposure to VCM at "E" factory should be reevaluated. In "A", "B" and "C" factory producing polyvinyl chloride resin, the average worker's exposures to VCM were 0.12 ppm, 0.86 ppm and 1.23 ppm, respectivery. Worker exposure to VCM at distillation and dry process was higer than other processes at "A" factory. The average exposure concentration of worker at polymerization process of "B" and "C" factory was 1.23 ppm, and 1.46 ppm respcetively. These concentration exceed 1 ppm, Permissible Exposure Limits of OSHA. Control room of "B" and "C" factory had 0.91 ppm and 0.65 ppm of worker's exposure concentration respectively. "A" factory was evaluated to be "acceptable", but "B" and "C" factories were evaluated to be "not acceptable", by the workplace exposure assessment program of AIHA. Process other than bagging and control room of "A" factory was evaluated to "not acceptable". Immediate correction measures for preventing workers from exposure to VCM should be performed in the factories or process that were evaluated to be "not acceptable". After these control measures are taken, worker exposure to VCM must be reevaluated through personal air monitoring. Control measures presented by this study are complete sealing of connecting pipe lines, flanging, packing, bolting and nutting. Periodic leak test for leak parts is also required. And positive pressure facility should be constructed at control room of "B" and "C" factory. Fresh air through cleaner such as HEPA filter should be supplied to control room. In addition to these control measures, periodic personal monitoring for evaluating worker exposure to VCM should be performed.

  • PDF

The distribution characteristics of airborne lead in the major monitoring locations in Korea (국내 주요지역의 대기 중 납성분에 대한 분포특성 조사)

  • Kim, K.H.;Jung, S.Y.
    • Journal of Environmental Policy
    • /
    • v.4 no.2
    • /
    • pp.83-101
    • /
    • 2005
  • Because of its strong potential for health hazards, the concentration levels of airborne lead (Pb) have been circumscribed by environmental laws in many countries. In this study, we made a comparative study on the environmental behavior of Pb for the acquisition of its distribution characteristics using data sets collected from major cities in Korea for a period of 6 years (1998 through 2003). According to this study, Pb concentration decreased slowly in most industrialized cities of Koreathroughout the whole study. period. In contrast, such temporal signals were not evident in data sets collected from residential, commercial, and grassland areas. Although seasonal patterns generally exhibited the occurrences of high Pb concentration during the spring, results appear to reflect the influence of Asian Dust (AD) in the springtime. The results of our study clearly indicate that Pb distribution is strongly influencedby source types in relation to their land use patterns. Comparison of our Pb data sets with that of other countries indicates that Pb concentration levels obtained from relatively cleaner districts of Korea are still significantly higher than other countries. The results of this analysis generally indicate that Pb concentrations in most areas are affected by the type and strength of man-made activities. Considering that most areas are affected by a variety of pollutants, continuous efforts are needed to control Pb concentrations in the atmosphere.

  • PDF

Preservation Values and Effects on Cleaning and Adhesive Agents for Plastic Artifacts (플라스틱 작품의 보존 가치 및 세척제와 접착제의 효능 평가)

  • Chung, Yong Jae;Yu, Ji A;Kang, Dai Ill
    • Journal of Conservation Science
    • /
    • v.29 no.2
    • /
    • pp.127-138
    • /
    • 2013
  • Plastic, widely used as a material for contemporary art, get damaged as directly exposed to temperature, humidity, ultra violet, etc. And it is very quickly damaged in early time, once damaged, it can't recover into original state. But like this characteristics, there is a few advanced research in Korea. So this study deal with a rising value of plastic artifacts in other country, United Kingdom and France, current conservation state, identification and cleaning method. Also 5 types of cleaners(distilled water, ethanol, acetone, eraser) and adhesives(cyanoacrylate, epoxy, acrylic, chloroprene rubber) were evaluated by produced plastics(PVC, PE, PP, PS, PU). As a result of experiment, ethanol and acetone that were previous evaluated in other research performed in other country are the best cleaner. Result of degradation after adhesive, cyanoacrylate and epoxy resin showed better performance and stability. As a basic research, this study is expected that can be used in future researches.

Comparison study of oral health care and dental treatments about the use of oral hygiene devices among the patients (치과병·의원 내원환자의 구강건강관리 및 진료특성별 구강위생용품 사용실태 비교)

  • Lee, Hyung-Suk;Kim, Young-Sun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.8 no.3
    • /
    • pp.149-160
    • /
    • 2008
  • This study has been performed for patients who visited dental clinic in Daegu and kyungpook area. The oral health care, dental treatments about the use of oral hygiene devices were obtained through self-administering questionnaires from 1 to 30, August, 2006. The obtained results were as follows: 1. The average percent of using dental floss was 34.2%, followed by interproximal brush was 33.9%, mouthrinse was 33.5%, electric toothbrush was 19.6%, orthodontic brush was 10.6%, and tongue cleaner was 10.2%. 2. Poor to perceive oral health was 36.4% in the patients who perceived oral hygiene device, and there was statistically significant difference (p<0.05). Moderate to perceive oral health was 40.8% in the patients who using oral hygiene device, and there was also statistically significant difference (p<0.05). 3. In the patients who 3 or 4 times toothbrushing a day, the average percent of perceived oral hygiene device was 67.7%, and the average percent of using oral hygiene device was 59.8% (p<0.05). In the patients who had experience of toothbrush education, the average percent of perceived oral hygiene device was 81.8%, and the average percent of using oral hygiene device was 58.1% (p<0.05). 4. The average percent of perceived oral hygiene device was 67.9% in dental implant treated patient, and was 69.0% in patients with cold teeth (p<0.05). The average percent of using oral hygiene device was 64.2% in prosthesis treated patient, and was 83.3% in patients with cold teeth (p<0.05). The average percent of non-using oral hygiene device was 67.6% in orthodontic treated patient (p<0.05). 5. In patient with periodontal disease, the average percent of using interproximal brush was 44.3%, followed by dental floss was 35.4%, mouthrinse was 27.8%, and electric toothbrush was 21.5%. In prosthesis treated patient, the average percent of using interproximal brush was 31.6%, followed by dental floss was 28.9%, and mouthrinse was 23.7%. In orthodontic treated patient, the average percent of using orthodontic brush was 82.4%, followed by interproximal brush was 64.7%, and mouthrinse was 47.1%. In dental implant treated patient, the average percent of using interproximal brush was 50.0%, followed by mouthrinse was 46.4%, and dental floss was 25.0%.

  • PDF

Development of System Dynamics model for Electric Power Plant Construction in a Competitive Market (경쟁체제 하에서의 발전소 건설 시스템 다이내믹스 모델 개발)

  • 안남성
    • Korean System Dynamics Review
    • /
    • v.2 no.2
    • /
    • pp.25-40
    • /
    • 2001
  • This paper describes the forecast of power plant construction in a competitive korean electricity market. In Korea, KEPCO (Korea Electric Power Corporation, fully controlled by government) was responsible for from the production of the electricity to the sale of electricity to customer. However, the generation part is separated from KEPCO and six generation companies were established for whole sale competition from April 1st, 2001. The generation companies consist of five fossil power companies and one nuclear power company in Korea at present time. Fossil power companies are scheduled to be sold to private companies including foreign investors. Nuclear power company is owned and controlled by government. The competition in generation market will start from 2003. ISO (Independence System Operator will purchase the electricity from the power exchange market. The market price is determined by the SMP(System Marginal Price) which is decided by the balance between demand and supply of electricity in power exchange market. Under this uncertain circumstance, the energy policy planners such as government are interested to the construction of the power plant in the future. These interests are accelerated due to the recent shortage of electricity supply in California. In the competitive market, investors are no longer interested in the investment for the capital intensive, long lead time generating technologies such as nuclear and coal plants. Large unclear and coal plants were no longer the top choices. Instead, investors in the competitive market are interested in smaller, more efficient, cheaper, cleaner technologies such as CCGT(Combined Cycle Gas Turbine). Electricity is treated as commodity in the competitive market. The investors behavior in the commodity market shows that the new investment decision is made when the market price exceeds the sum of capital cost and variable cost of the new facility and the existing facility utilization depends on the marginal cost of the facility. This investors behavior can be applied to the new investments for the power plant. Under these postulations, there is the potential for power plant construction to appear in waves causing alternating periods of over and under supply of electricity like commodity production or real estate production. A computer model was developed to sturdy the possibility that construction will appear in waves of boom and bust in Korean electricity market. This model was constructed using System Dynamics method pioneered by Forrester(MIT, 1961) and explained in recent text by Sternman (Business Dynamics, MIT, 2000) and the recent work by Andrew Ford(Energy Policy, 1999). This model was designed based on the Energy Policy results(Ford, 1999) with parameters for loads and resources in Korea. This Korea Market Model was developed and tested in a small scale project to demonstrate the usefulness of the System Dynamics approach. Korea electricity market is isolated and not allowed to import electricity from outsides. In this model, the base load such as unclear and large coal power plant are assumed to be user specified investment and only CCGT is selected for new investment by investors in the market. This model may be used to learn if government investment in new unclear plants could compensate for the unstable actions of private developers. This model can be used to test the policy focused on the role of unclear investments over time. This model also can be used to test whether the future power plant construction can meet the government targets for the mix of generating resources and to test whether to maintain stable price in the spot market.

  • PDF

Long-term Trend Analysis of Korean Air Quality and Its Implication to Current Air Quality Policy on Ozone and PM10 (국내 기준성 대기오염물질의 권역별 장기 추이 및 원인 분석: PM10과 오존을 중심으로)

  • Kim, Jeonghwan;Ghim, Young Sung;Han, Jin-Seok;Park, Seung-Myung;Shin, Hye-Jung;Lee, Sang-Bo;Kim, Jeongsoo;Lee, Gangwoong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.1-15
    • /
    • 2018
  • Nation-wide systematic and comprehensive measurements of air quality criteria species have been made over 340 sites currently in Korea since 1990. Using these data, temporal and spatial trends of $SO_2$, $PM_{10}$, $NO_2$, $O_3$, CO and $O_x(NO_2+O_3)$ were analyzed to characterize and evaluate implementing efficiency of air quality policy and regulations. Due to strict and effective policy to use cleaner fuels in late 1980s and 1990s, the primary pollutants, such as $SO_2$, CO, and $PM_{10}$ decreased sharply by early 2000s in all parts of Korea. After this period, their concentrations declined with much lower rates in most parts of Korea. In addition, isolated but noticeable numbers of places, especially in major ports, newly developing towns and industrial parks, sustained high levels or even showed further degradation. Despite series of emission control strategies were enforced since early 1990s, $NO_2$ concentrations haven't changed much till 2005, due to significant increase in number of automobiles. Nevertheless, we confirmed that the staggering levels of $NO_2$ and $PM_{10}$ improved evidently after 2005, especially in Seoul Metropolitan Area (SMA), where enhanced regulations for $NO_2$ and $PM_{10}$ emissions was imposed to automobiles and large emission sources. However, their decreasing trends were much lessened in recent years again as current air quality improvement strategies has been challenged to revise further. In contrast to these primary species, annual $O_3$, which is secondary product from $NO_2$ and volatile organic compounds (VOCs), has increased consistently with about 0.6 ppbv per year in every urban part of Korea, while yearly average of daily maximum 8-hour $O_3$ in summer season had a much higher rate of 1.2 ppbv per year. Increase of $O_3$ can be explained mainly by reductions of NO emission. Rising background $O_3$ in the Northeast Asia and increasing oxidizing capacity by changing photochemistry were likely causes of observed $O_3$ increase. The future air quality policy should consider more effective ways to lower alarming level of $O_3$ and $PM_{10}$.

A Study on Design of Vacuum Silo for Batch Treatment System for Dredged Soil (준설토 일괄처리시스템을 위한 진공사이로 설계에 관한 연구)

  • Kim, Yong-Seok;Yang, Hae-Rim;Kim, Hac-Sun;Jeoung, Chan-Se;Yang, Soon-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.571-577
    • /
    • 2012
  • In this study, a small movable batch treatment system for dredging soil deposited in a rain water tube is proposed; further, a vacuum silo sorting separation device with a vacuum silo, first-stage sorting separator, and conveyor is designed. The vacuum silo sorting separation device also consists of a storage tank, transferring screw, vacuum gate, screen bar, screen bar cleaner, and vacuum discharging device. In view of the fact that the flow of drawn air in the storage tank is a major factor influencing the sorting separation performance, the optimum shape of the tank is determined by CFD flow analysis. In addition, by using CAE structure analysis, the safety of a storage tank made of boards is examined. The specifications of the vacuum silo sorting separation device are determined by conducting mechanical and dynamic simulations of the driving mechanism of the vacuum silo sorting separation device through 3D-CAD modeling. Following this study, we will design a drum-screen-type second sorter, a decanter-type dehydration device, and waste water tank and pump as a secondary device. Further, on the basis of this design, we will construct a prototype model and carry out a field test.

Analysis of Broken Rice Separation Efficiency of a Laboratory Indented Cylinder Separator

  • Kim, Myoung Ho;Park, Seung Je
    • Journal of Biosystems Engineering
    • /
    • v.38 no.2
    • /
    • pp.95-102
    • /
    • 2013
  • Purpose: Using a laboratory indented cylinder separator, broken rice separation experiments were conducted and the characteristics of the separation process were studied to provide information for developing a prototype indented cylinder broken rice separator. Methods: Rice (Ilmi variety) milled in a local RPC was used for the experiment. Rice kernels were classified into four groups according to their length l; whole kernels (I > 3.75 mm), semi-whole kernels (2.5 < I < 3.75 mm), broken kernels (1.75 < I < 2.5 mm), and foreign matters (I < 1.75 mm). A laboratory grain cleaner, Labofix '90 (Schmidt AG, Germany) was used for the experiments. Experiments were designed as a $4{\times}4$ factorial arrangement in randomized blocks with three replications. Cylinder rotational speeds (17, 34, 51, 68 rpm) and trough angles (15, 37.5, 60, $82.5^{\circ}$) were the two factors and feed rates (25, 50 kg/h), indent shapes (Us, $S_1$ type), and indent sizes (2.5, 3.75 mm) were treated as the blocks. Two 125 g samples and one 125 g sample were taken at the cylinder outlet and from the trough, respectively. The whole, semi-whole, and broken kernel weight ratio of the samples and feed was determined by a rice sizing device. From these weight ratios, purities, degrees of extraction and coefficient of separation efficiency were calculated. Results: Trough angle, cylinder speed, and their interaction on the coefficient of separation efficiency were statistically significant. Cylinder speed of 17, 34, and 51 rpm made the most effective separation when the trough angle was $15^{\circ}$ or $37.5^{\circ}$, $60^{\circ}$, and $82.5^{\circ}$, respectively. Maximum values of coefficient of separation efficiency were in the range of 60 to 70% except when the indent size was 2.5 mm and were recorded for the combinations of low cylinder speed (17 rpm) with medium trough angle ($37.5^{\circ}$ or $60^{\circ}$). Indent shape did not appear to make any noticeable difference in separation efficiency. Conclusions: Due to the interaction effect, the trough angle needs to be increased appropriately when an increase in cylinder speed is made if a rapid drop of effectiveness of separation should be avoided. In commercial applications, $S_1$ type indents are preferred because of their better manufacturability and easier maintenance. For successful separation of broken kernels, the indent size should be set slightly bigger than the actual sizes of broken kernels: an indent size of 3.0 mm for separating broken kernels shorter than 2.5 mm.