• 제목/요약/키워드: cleaner

Search Result 673, Processing Time 0.036 seconds

Bioactive and Skin-compatible Properties of Silk Sericin (세리신 단백질의 생리활성과 피부친화성 탐색)

  • 이광길;여주홍;이용우;권해용;김종호
    • Journal of Sericultural and Entomological Science
    • /
    • v.43 no.2
    • /
    • pp.109-115
    • /
    • 2001
  • Silk sericin protein was extracted by treatment with enzyme or NaOH solution from raw silk and culled-cocoon shell. The extracted sericin was characterized and examined the functional properties as well as subjective properties for its use as a soap and a body cleaner. The optimum extraction conditions on specimen are NaOH (0.02 wt.%) or enzyme, Flavourzyme 3% under N2 gas. Molecular weights of sericin was decreased by treatment with enzyme, Actinase, from 10,000-30,000 to 2,700-4,200. Sericin showed important bioactive properties, for instance, lowering effect on blood glucose and alcohol. Subjective test of sericin soap and body cleaner showed superior in washability, foamability, and skin hydration, etc., to commercial soap and body cleaner. Therefore, it is thought that silk sericin can be expected as the source of bioactive and skin-compatible materials.

  • PDF

A Study on the Measurement of the Pollution Level of Bacteria and Disinfection of Table and IP Cassette (촬영 테이블과 IP Cassette의 세균 오염도 측정 및 소독에 관한 연구)

  • Bae, Seok-Hwan;Lee, Moo-Sik;Lim, Chang-Seon;Kim, Gha-Jung
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.229-237
    • /
    • 2008
  • Purpose : For the number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories, after identifying the bacteria before and after using alcohol and tissue including disinfectant and statistically testing, this research was intended to provide the basic data for the prevention and the right disinfection guideline for infection management of hospitals in diagnostic radiology. Subject and Method : The subject of this research was the general room of diagnostic radiology of a university hospital in Daejeon City. The research was conducted from Apr 5 to Apr 12, 2007. The number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories were tested before and after using alcohol and tissue for disinfection including disinfectant. In order to collect specimens exactly, they were collected with the nurse who specialized in infection management of the hospital, and statistical processing was done with SPSS V13.0. To compare the results before and after using alcohol and tissue, T-test was implemented, and post-hoc test was conducted. Results : Bacteria were detected in 19 cases of 24 subjects(79.2%), however, they were not detected in 5 cases(20.8%). 7kinds of bacteria were detected as isolated bacteria, of which Methicillin Resistant coagulase-negative Staphylococci(MRCNS) were detected in 15 cases(62.5%), which was most, Methicillin Resistant Staphylococcus Aureus(MRSA) in 6 cases(16.7%), Enterococcus Faecium(EFM) in 5 cases(20.8%), Acinetobacter baumannii(ABA) in 2 cases(8.3%), and Bacillus sp, Coagulase-negative Staphylococci(CNS), and Enterococcus sp(ENT) in 1 case, respectively(4.2%). In all bacteria except ABA, Gram positive bacillia were detected in 30 cases(97%), and Gram negative bacilli were detected only in 1 case(3%). As for the kinds of bacteria and the number of groups before and after using 70% Alcohol by Groups, when the bacteria were identified after disinfecting IP Cassette and Table with 70% Alcohol, all the bacteria became extinct in both IP Cassette and Table Group(100%). As for the kinds and number of bacteria before and after using Tissue Cleaner by Groups, the bacteria in Tissue Cleaner Group became completely extinct only in 10 Groups(71.2%), and in 4 Groups, there was much decrease in bacteria, however, they were still detected. The extinction rate of all the bacteria was 91.5%. That is, though the other bacteria became extinct(100%), that of MRCNS bacteria was lowest(83.6%), followed by MRSA(95%). Conclusion : As a result of comparing the mean of the bacteria which were detected before and after using 70% Alcohol and Tissue Cleaner, there was statistically significant in the significant level of 5% in both of them.

  • PDF

A Review on the Performance Criteria of Equipment Required for Asbestos Removal (석면 해체.제거 작업에서 사용되는 장비의 성능 기준에 관한 고찰)

  • Lee, Naroo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.3
    • /
    • pp.212-221
    • /
    • 2013
  • Objectives: Asbestos fibers are accumulated in negative pressure unit (NPU) or vacuum cleaner in asbestos removal. Failure of operation or poor use performance of the NPU or vacuum cleaner causes asbestos fibers to spread in the air. Asbestos contractors should have an NPU fitted with a HEPA , vacuum cleaner, decontamination area, respirators, wetting equipment, and differential pressure manometer to register with the Ministry of Employment and Labor. There should be performance criteria of equipment used in asbestos removal. But there are none such criteria used in asbestos removal. This study was performed to investigate international or national performance criteria of equipment used in asbestos removal. Methods: Regulations, approved code of practice, guidance and national standards of the UK, USA and Korea were reviewed. A survey was done to investigate the requirements for equipment used in asbestos removal in Korea. Results: Air flow of NPUs used in Korea usually covers from$500m^3/h$ to over $3000m^3/h$. Some requirements for NPUs used in Korea were missing compared to the requirements of British standards for NPUs. All NPUs have different missing requirements. The UK also has separate British standard for leak tests for NPUs. Highly hazardous class vacuum cleaners should be used in asbestos removal in the UK. It has national standards on the operation of vacuum cleaners used in asbestos removal. There is only a certification system for less than 2.5kw rated voltage vacuum cleaners for home use in Korea. Powered (-assisted) respirators with mask are recommended in asbestos removal. Type 5 coveralls should be used in asbestos removal in the UK. There are international standards for requirements and leak tests of type 5 coveralls. A manometer for measuring differential pressure is needed in asbestos removal. The manometer's measuring range should cover less than ${\pm}125$ Pa and the gradation of manometer should be less than 2.5 Pa. The definition of decontamination area should be corrected. Installation of airlock and minimum area should be considered in decontamination area. Conclusions: Equipment should be used in asbestos removal proper performance and no leaks. There should be a certification system for equipment used in asbestos removal. This study can help to a certification system for equipment used in asbestos removal in Korea.

Influence of Soil Pollutants and Fertilizers on Degradation Rate of Herbicide Alachlor in Soil (토양(土壤)중 제초제(除草劑) alachlor 분해(分解)에 미치는 토양(土壤) 오염(汚染) 물질(物質)과 비료(肥料) 성분(成分)의 영향(影響))

  • Kim, Young-Seok;Kim, Yong-Hwi;Moon, Young-Hee
    • Korean Journal of Weed Science
    • /
    • v.17 no.2
    • /
    • pp.214-219
    • /
    • 1997
  • The influence of manure, chemical fertilizers, heavy metals and cleaner on the rate of degradation of alachlor in soil was studied. The degradation rate of alachlor in the soil followed first-order reaction kinetics. The half-life was 6.4 days. The degradation was accelerated by the amendment of manure. Adding chemical fertilizers to the soil enhanced alachlor degradation more in the presence of nitrogen than potassium. On the other hand, adding heavy metals or cleaner to the soil decreased the degradation rate. The half-life of alachlor in soil treated with Cd, Cr, Ni, Zn and Cu was 11.0, 8.3, 7.9, 7.2 and 6.7 days, respectively, and that of the cleaner is 7.5 days. The microbial biomass and the respiration rate in the soil were promoted by the amendment of manure and chemical fertilizers, and inhibited by the addition of heavy metals and cleaner. The degradation rate correlate positively with the microbial biomass and the respiration rate.

  • PDF

The Investigation on Ultrasonic Cleaning of Soft Contact Lenses in Local Optical Shops and the Protein Removal Effect by Lens Containers (안경용 초음파세척기를 이용한 소프트렌즈 세척 실태 조사와 세척용기에 따른 단백질 제거 효과)

  • Koo, Sung Bong;Cho, Seul Bee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.31-40
    • /
    • 2011
  • Purpose: This study was performed to investigate the actual state about ultrasonic cleaning of soft contact lenses in local optical shops and evaluate the removal effect of protein deposit on soft contact lenses with different lens containers by ultrasonic cleaner for eyeglasses. Methods: The actual state about ultrasonic cleaning of soft contact lenses was surveyed in total 75 local optical shops in Seoul, Korea. The cleaning efficacy of different lens containers was compared by measuring the protein remained on ocufilcon D contact lenses after washing by an ultrasonic cleaner for eyeglasses. The changes on surfaces and wetting angles of ocufilcon D contact lenses by repeat ultrasonication were further investigated. Results: The main purpose to use ultrasonic cleaners in local optical shops was rapid cleaning. The ultrasonic cleaning efficacy of ocufilcon D contact lenses with glass containers was little higher than it with plastic containers, but was not significantly different. The changes on surfaces and wetting angles of ocufilcon D contact lenses in a plastic lens container by repeat ultrasonication such as 30 and/or 60 times were shown. Conclusions: There was not significant difference in cleaning efficacy between glass and plastic lens containers. However, repeat cleaning with ultrasonic cleaner for eyeglasses would be carefully considered since some significant changes in the parameters of lens surface and wetting angles were detected by repeat ultrasonification even when lens containers were used for ocufilcon D contact lens during ultrasonictions.

Analysis of the Effects of Public R&D Subsidy on Private R&D Investment in the Cleaner Production - Complementary or Crowding-out Effect - (청정생산R&D 정부출연금의 기업R&D투자에 대한 효과분석 - 민간기업R&D투자의 보완.대체효과를 중심으로 -)

  • Ju, Hong-Shin;Kim, Jum-Su;Park, Jung-Gu
    • Clean Technology
    • /
    • v.17 no.2
    • /
    • pp.181-188
    • /
    • 2011
  • In this study, the complementary or crowding-out effects of public R&D subsidy on private R&D investment in the cleaner production were analysed between the effects and the major determinants (company size, R&D investment intensity, ratio of government investment, R&D manpower intensity). Among 207 firms' projects, the number of the complementary effect was 95 (45.9%) while that of crowding-out effect was 38 (18.4%). Resulting from logistic regression, the higher the R&D investment of sponsored companies is, the more complementary effect they show, responding to public R&D subsidy, and increase own R&D investment. The other determinants, however, showed no significant effects on firms' R&D investment. To heighten the effect of public cleaner production R&D, it is need to increase the priority of R&D investment intensity among the determinants. And to increase the performance of governmental R&D investment, further studies for the individual public R&D programs are necessary.

Removal Efficiency of Pesticide Residues on Apples by Ultrasonic Cleaner (초음파 세척기를 이용한 사과의 잔류농약 제거 효과)

  • Yoon, Chae-Hyuk;Park, Woo-Churl;Kim, Jang-Eok;Kim, Chung-Hyo
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.3
    • /
    • pp.255-258
    • /
    • 1997
  • In order to determine the removal efficiency of pesticide residues on apples by ultrasonic cleaner, apples(Fuji var.) were artificially treated by dipping in water solution of fenitrothion EC, chlorpyrifos EC and phenthoate EC. The treated apples were washed by the ultrasonic cleaner with water, 30% ethanol solution or 0.2% detergent solution, respectively. The removal efficiency of fenitrothion, chlorpyrifos and phent-hoate by ultrasonicated washing in water for 0.5min. was 39.2%, 32.0% and 50.4%, respectively, but there was a tendency to decrease the removal efficiency of the pesticide residues as the duration of ultrasonicated washing period is increased. The maximum removal efficiency of the pesticide residues washed in the detergent solution was observed by ultrasonicated washing the samples for 5min. and it was recorded as 33.5% ; fenitrothion, 30.1% ; chlorpyrifos and 48.3% ; phenthoate, respectively. However it's appeared that the longer the ultrasonicated washing period in 30% ethanol solution the more pesticides from the apples were removed and the maximum removal efficiency of the pesticides was recorded as 66.2%(fenitrothion ; washed for 15min.), 41.7%(chlorpyrifos ; washed for 10min.), 74.2%(phenthoate ; washed for 10min.).

  • PDF

Optimal design of impeller in fan motor unit of cordless vacuum cleaner for improving flow performance and reducing aerodynamic noise (무선진공청소기 팬 모터 단품의 유량성능 향상과 공력소음 저감을 위한 임펠라 최적설계)

  • Kim, KunWoo;Ryu, Seo-Yoon;Cheong, Cheolung;Seo, Seongjin;Jang, Cheolmin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.5
    • /
    • pp.379-389
    • /
    • 2020
  • In this study, the flow and noise performances of high-speed fan motor unit for cordless vacuum cleaner is improved by optimizing the impeller which drives the suction air through flow passage of the cordless vacuum cleaner. Firstly, the unsteady incompressible Reynolds averaged Navier-Stokes (RANS) equations are solved to investigate the flow through the fan motor unit using the computational fluid dynamics techniques. Based on flow field results, the Ffowcs-Williams and Hawkings (FW-H) integral equation is used to predict flow noise radiated from the impeller. Predicted results are compared to the measured ones, which confirms the validity of the numerical method used. It is found that the strong vortex is formed around the mid-chord region of the main blades where the blade curvature change rapidly. Given that vortex acts as a loss for flow and a noise source for noise, impeller blade is redesigned to suppress the identified vortex. The response surface method using two factors is employed to determine the optimum inlet and outlet sweep angles for maximum flow rate and minimum noise. Further analysis of finally selected design confirms the improved flow and noise performance.

Study on the Open-type Wearable Air Cleaner Design (개방형 웨어러블 공기청정기 디자인 연구)

  • Choi, Kyu-Han;Baek, Joon-Sang
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.12
    • /
    • pp.74-81
    • /
    • 2020
  • As of 2020, due to the influence of fine dust from China and domestic dust, the cloudy sky of Korea has become a daily routine not only in spring but also in autumn/winter. In 2013, the International Cancer Institute under the World Health Organization designated fine dust as a group 1 carcinogen that has been confirmed to be carcinogenic to humans. The purpose of this study is to theoretically review 5 fine dust-related design studies, by analyzing the case of three types of wearable air purifiers on the market, it is to propose an improved open wearable air purifier. As a verification method, a working prototype was produced to measure the amount of fine dust reduction. Therefore, this study derived three design insights of wearable air cleaner through case analysis. First, it maximizes openness by minimizing the area touching the face. Second, the nozzle where the air comes out should be close to the respiratory organ. Third, position of the motor is to be as far away as possible from the ear considering the noise. Based on this, I suggested an open-type wearable air purifier design that maximizes the user openness and improves the wearing comfort. I hope that it will be an opportunity to increase the coverage of wearable air cleaner and protect the respiratory health of users.