• 제목/요약/키워드: clean-up

검색결과 841건 처리시간 0.028초

우리나라 해안오염 방제종료 의사결정절차의 고찰 (A Study on the Decision Making Procedure of Clean-up Endpoints for Oiled Shorelines in Korea)

  • 김동근;정해종;김재동
    • 수산해양교육연구
    • /
    • 제24권5호
    • /
    • pp.712-720
    • /
    • 2012
  • Recently, many problems related on shoreline response to spill oil were exposed again on a occasion of M/T Hebei spirit accident even though the weakness on the shoreline response system has been brought up since M/T Sea Prince oil spill accident. Therefore the establishment of shoreline response system that best suits our country is needed through considering the response system of well-developed country. The socioeconomic conflict between the persons concerned on the clean-up endpoints can be sharpened in Korea because the frequency of coastal use of our country is too high compared to other countries. Thus procedural justification, that is, how the clean-up endpoints be established is more important than what type of clean-up endpoints be used. In the present paper, we attempted to suggest a new manner on the decision making system for clean-up endpoints that best suits our country. The decision making system for clean-up endpoints need to be divided into two steps, that is, set-up step of clean-up endpoints criteria and decision step of clean-up endpoints. The decision making organization of local governments play a key role in case of set-up step of clean-up endpoints criteria, while the response command headquarters under Korean coast guard and decision making organization of local governments codecide whether the clean-up endpoints criteria is fits or not.

Aflatoxin 분석법에 관한연구;추출 및 정제방법의 비교 (Comparative Study on the HPLC Determination of Aflatoxins Coupled with Extraction and Clean-up Methods)

  • 김종규
    • 한국식품위생안전성학회지
    • /
    • 제8권4호
    • /
    • pp.251-254
    • /
    • 1993
  • Extraction and Clean-up procedures coupled with quantitation by high performance liquid chromatography(HPLC) was evaluated for the detection of 4 aflatoxins, B1, B2, G1 and G2, in peanut butter. The Sep-pak clean-up method showed poorer separation and repeatability than did the modified DeVries' and an immunoaffinity column clean-up methods. No significant difference of detected aflatoxins between the affinity column clean-up and modified DeVries' method. The coefficients of variation for the 4 aflatoxins were ranging from 6.3∼32.3 by the modified DeVries' method and 5.3∼9.8 by the affinity column clean-up.

  • PDF

국립공원 방문자의 환경훼손행위 관리를 위한 방송프로그램의 효과에 관한 연구 (Effectiveness of Mass Communication Program for Managing Visitors' Depreciative Behavior in National Park)

  • 최성식;김용근
    • 한국조경학회지
    • /
    • 제25권4호
    • /
    • pp.82-88
    • /
    • 1998
  • The purposes of this study was : 1) to describe the theoretical background of Clean-up Time Movement managing visitors' depreciative behavior ; 2) to test the effectiveness of a mass communication program, Clean-up Time Movement in National Park. This study employed a field experimental design (Multiple time-series design) in Naejangsan National Park. This study evaluated the differential effectiveness of the self-developed Clean-up Time Movement Program to reduce littering behavior between Control groups (Those who not received Clean-up Time Program) and Treatment groups (Those who received Clean-up Time Program) by weighting trash gathered in a litter box and scattered around picnic ground. The results showed that the Clean-up Time Movement Program was more effective to reduce the total trash and the trash degree per a person in Treatment groups than Control groups. It seemed to effective in managing depreciative behavior through the mass communication program in National Park.

  • PDF

Utilization of EPRI ChemWorks tools for PWR shutdown chemistry evolution modeling

  • Jinsoo Choi;Cho-Rong Kim;Yong-Sang Cho;Hyuk-chul Kwon;Kyu-Min Song
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3543-3548
    • /
    • 2023
  • Shutdown chemistry evolution is performed in nuclear power plants at each refueling outage (RFO) to establish safe conditions to open system and minimize inventory of corrosion products in the reactor coolant system (RCS). After hydrogen peroxide is added to RCS during shutdown chemistry evolution, corrosion products are released and are removed by filters and ion exchange resins in the chemical volume control system (CVCS). Shutdown chemistry evolution including RCS clean-up time to remove released corrosion products impacts the critical path schedule during RFOs. The estimation of clean-up time prior to RFO can provide more reliable actions for RCS clean-up operations and transients to operators during shutdown chemistry. Electric Power Research Institute (EPRI) shutdown calculator (SDC) enables to provide clean-up time by Co-58 peak activity through operational data from nuclear power plants (NPPs). In this study, we have investigated the results of EPRI SDC by shutdown chemistry data of Co-58 activity using NPP data from previous cycles and modeled the estimated clean-up time by EPRI SDC using average Co-58 activity of the NPP. We selected two RFO data from the NPP to evaluate EPRI SDC results using the purification time to reach to 1.3 mCi/cc of Co-58 after hydrogen peroxide addition. Comparing two RFO data, the similar purification time between actual and computed data by EPRI SDC, 0.92 and 1.74 h respectively, was observed with the deviation of 3.7-7.2%. As the modeling the estimated clean-up time, we calculated average Co-58 peak concentration for normal cycles after cycle 10 and applied two-sigma (2σ, 95.4%) for predicted Co-58 peak concentration as upper and lower values compared to the average data. For the verification of modeling, shutdown chemistry data for RFO 17 was used. Predicted RCS clean-up time with lower and upper values was between 21.05 and 27.58 h, and clean-up time for RFO 17 was 24.75 h, within the predicted time band. Therefore, our calculated modeling band was validated. This approach can be identified that the advantage of the modeling for clean-up time with SDC is that the primary prediction of shutdown chemistry plans can be performed more reliably during shutdown chemistry. This research can contribute to improving the efficiency and safety of shutdown chemistry evolution in nuclear power plants.

투수성 반응벽에 의한 오염지하수 복원효과 분석 (Clean-up of Contaminated Groundwater by Permeable Reactive Barrier)

  • 정하익;김상근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.542-547
    • /
    • 2000
  • It has become interested in the concept of permeable barriers for the containment and/or destruction of contaminated groundwater. The purpose of these trench-like barriers is to provide in situ capture and possibly destruction of the contaminant while preserving groundwater flow to uncontaminated zones. For instance, a trichloreethylene(TCE) plume may be contained by a permeable in which reactive iron reduces TCE to ethylene and ethane, compounds which can be easily biodegraded. The objective of this research is to examine the feasibility of using zero-valent iron as a clean-up media in permeable reactive barrier system. A series of laboratory column tests are performed. The concentration of influent and effluent water and the rate of clean up are analysed from these test results. The experimental result shows that the majority of the contamination in groundwater is removed in the reactor. And it shows the corresponding increase in the concentration of chloride ions through the reactor. Results from this study indicate that permeable reactive barrier containing admixtures of zero-valent iron and other materials can effectively clean up groundwater contaminated with organic compounds.

  • PDF

우리나라 기름오염방제제도의 문제점과 개선방안 (National Oil Pollution Response System : Current Issues and Policy Recommendation)

  • 목진용
    • 해양환경안전학회지
    • /
    • 제7권2호
    • /
    • pp.105-121
    • /
    • 2001
  • After the Sea Prince oil spill accident in 1995, the korean government has taken a measure to establish an emergency response system and equip clean-up capacity against large spill, major contents of which are as follows: First, Korea Marine Pollution Response Corporation has been established as a non-government organization for recovery of spilled oil in order to improve private response capabilities. Second, clean-up equipments, such as large clean-up vessels and oil fences for the open sea operation has been expanded. Third, a national contingency plan on the large spill accidents has been established compliance with the provisions of Article 6 of the OPRC 1990. However, there exist some problems in the national response system, such as clearly roles definition between government and private agencies; propel amendment of the Marine Pollution Prevention Act to incorporate major contents of the OPRC 1990; and training and exercises of clean-up personnel. With the above problems in mind, this paper reviews the current issues on the national oil pollution response system and recommends policy-making to tackle to those problems.

  • PDF

삼각격자에 대한 위상학적 개선과정의 확장 (Extension of Topological Improvement Procedures for Triangular Meshes)

  • 맹주성;한석영;최형일
    • 대한기계학회논문집B
    • /
    • 제25권6호
    • /
    • pp.853-859
    • /
    • 2001
  • This paper describes the extended topological clean up procedures to improve the quality of unstructured triangular meshes. As a postprocessing step, topological improvement procedures are applied both for elements that are interior to the mesh and for elements connected to the boundary and then Laplacian-like smoothing is used by default. Previous clean up algorithms are limited to eliminate the nodes of degree 3,4,8,9,10 and pairs of nodes of degree 5. In this study, new clean up algorithms which minimize the triple connection structures combined with degree 5 and 7 (ie ; 5-7-5, 7-7-5, 7-5-7 etc) are added. The suggested algorithms are applied to two example meshes to demonstrate the effectiveness of the approach in improving element quality in a finite element mesh.

여수 유류유출사고 방제작업자의 건강영향평가 (Health Effect Assessment on Cleanup Workers of an Oil Spill in Yeosu)

  • 김근배;강택신;윤미라;조혜정;주영경;유승도;이보은
    • 한국환경보건학회지
    • /
    • 제42권6호
    • /
    • pp.385-395
    • /
    • 2016
  • Objectives: The aim of this study was to assess exposure to VOCs and PAHs and the health effects on volunteers who participated in an oil spill cleanup in Yeosu. Methods: Atmospheric VOCs were evaluated in the vicinity of the accident site and questionnaire surveys were conducted to identify personal characteristics and acute health symptoms of clean-up workers seven days after the accident. The levels of metabolites of VOCs (t,t-MA, HA, PGA, MA, MHA) and PAHs (2-NAP, 1-OHP, 2-HF, 1-HPH), oxidative stress markers (TABARS, 8-OHdG) in the urine of workers were analyzed. Their correlation was determined by multiple regression analysis with SAS ver. 9.4. Results: Although the concentration of atmospheric VOCs in the residential areas were low at the time of survey, the levels of VOCs and PAHs metabolites in clean-up workers were higher than those in the control group after clean-up activities. The levels of urinary VOC and PAH metabolites were significantly increased after clean-up compared to those measured before participation. The thiobarbituric acid reactive substance (TBARS) concentrations were also increased and showed significant correlations with those of metabolites of benzene. Conclusion: This study shows that oil spill clean-up activities affect exposure to VOCs and PAHs and the health of clean-up workers. The results suggest the need for check-ups of participants in oil spill cleaning work.

환경대기 중 프탈레이트 화합물의 농도 측정 (II) - 실험재료 전처리 및 시료정제과정 평가 - (Determination of Phthalates Compounds in the Ambient Atmosphere (II) - Evaluation of Experimental Artifacts and Sample Clean-up Procedures -)

  • 박영화;황윤정;서영교;백성옥
    • 대한환경공학회지
    • /
    • 제32권5호
    • /
    • pp.455-460
    • /
    • 2010
  • 본 연구에서는 프탈레이트 화합물 측정 시 시료채취 및 분석과정 증에서 야기될 수 있는 공시료의 오염여부를 평가하고 clean-up 절차와 같은 적절한 개선 방안을 제시하였다. 실험도구 및 시료채취 매체에 대한 공시료를 평가한 결과 많은 종류의 실험기구 및 장치에서 DBP와 DEHP가 잔존하는 것으로 나타났다. 따라서 실험도구는 반드시 전처리하여 사용해야 하며, 이후 공시료 보정이 수반되어야 한다. 또한 본 연구에서 제시한 clean-up 방법을 통해 불순물이 많이 제거되었으며, GC/MS를 이용한 정성?정량분석에서 정도개선에 효과적인 것으로 나타났다.

태안 Hebei Spirit 유출 유류 제거작업 후 발생한 호흡부전 1예 (A Case of Respiratory Failure after Clean-up Work of the Hebei Spirit Crude Oil Spill in Taean)

  • 경선영;전수연;김유진;이상표;박정웅;정성환
    • Tuberculosis and Respiratory Diseases
    • /
    • 제67권3호
    • /
    • pp.249-253
    • /
    • 2009
  • On 7 December 2007, the Hebei Spirit ran aground near Taean and released approximately 10,900 tons of oil into the sea. Crude oil on the coastal areas and fumes in the air increased the number of health problems among the local population. We report a case of respiratory failure after the oil spill clean-up work. A 66-year-old female was admitted to hospital with cough, sputum, and dyspnea of 1-month duration after the oil spill clean-up. She was diagnosed with community-acquired pneumonia and treated with empirical antibiotics. However, she had progressive respiratory failure without identification of the pathogen. Respiratory failure due to chronic inhalation of hydrocarbons from the crude oil spill clean-up was suspected. After mechanical ventilation care, she recovered from respiratory failure and was discharged. We report a case of severe respiratory toxic effects after an oil spill clean-up. We concluded that long-term hydrocarbon inhalation during the oil spill clean-up may have induced respiratory failure in this case.