• 제목/요약/키워드: clean technique

검색결과 236건 처리시간 0.028초

Shearing Conditions on the Interface of a Spherical Water Drop Sinking in Silicone Oil

  • Uemura, Tomomasa;Yamauchi, Makoto
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1845-1852
    • /
    • 2001
  • This paper deals with the experiment to obtain quantitative information about conditions of the interface between a water drop and surrounding oil. Velocity distributions in very close region of the interface are measured by introducing a new illumination technique and a telecentric lens. It enables precise measurements of velocity distributions in the close region to the interface. Although the measured velocity distributions exhibit strong influence from the solid wall of an experimental tube, the coincidence of inner and outside velocities on the interface is clearly confirmed for the clean interface. The shearing stresses on the interface, which are proportional to the velocity gradient normal to the interface, clearly show conditions of contaminated interface, which can be divided into two parts. From front stagnation point to somewhere near a separation point, the distribution of shearing stresses is well coincide with that of the Hadamard's analytical solution, while the distribution on the latter part of the interface sows quite different feature, which is supposed to be strongly influenced by contamination of the surface.

  • PDF

연직배수재를 이용한 토양세정시스템의 오염토양정화 특성 (The Characteristics of Soil Remediation by Soil Flushing System Using PVDs)

  • 박정준
    • 한국환경복원기술학회지
    • /
    • 제10권5호
    • /
    • pp.76-86
    • /
    • 2007
  • For the purpose of ground improvement by means of soil flushing systems. Incorporated technique with prefabricated vertical drains have been used for dewatering from fine-grained soils. The laboratory model tests were performed by using the flushing tracer solutions for silty soils and recorded the tracer concentration changes with the elapsed time and flow rates. A mathematical model for prediction of contaminant transport using the PVD technology has been developed. The clean-up times for the predictions on both soil condition indicate more of a sensitivity to the dispersivity parameter than to the extracted flow rate and vertical velocity parameters. Based on the results of the analyses, numerical analysis indicate that the most important factor to the in-situ soil remediation in prefabricated vertical drain system is the effective diameter of contaminated soil.

Optimization of Ni2+ adsorption on 13X zeolite using box-behnken design

  • Jafari, Shoeib;Bandarchian, Farideh
    • Advances in environmental research
    • /
    • 제6권3호
    • /
    • pp.217-227
    • /
    • 2017
  • In this study, the elimination of $Ni^{2+}$ using 13X sorbent due to an electrostatic interaction was reported. The significant factors including pH, time and 13X sorbent amount were investigated using Box-Behnken design (BBD). In the optimum experimental conditions, the linear rang and limit of detection of the proposed method were 0.1-20 and $0.102mg\;L^{-1}$, respectively. The precision as RSD% was 1.3% for concentration of $2mg\;L^{-1}$. Concerning the excellent recoveries in a short time with highly efficient sample clean-up and removal, this method may be a very powerful and innovative future sample removal technique. To the best of our knowledge, this is the first report on using BBD for optimizing the parameters affected the removal of $Ni^{2+}$ by 13X zeolite sorbent.

차세대 반도체 표면 클리닝 기술들의 특성 및 전망

  • 이종명;조성호
    • 한국레이저가공학회지
    • /
    • 제4권3호
    • /
    • pp.22-29
    • /
    • 2001
  • A development of new surface clwaning technol ogies such as laser and aerosol in paeallel with the improvement of conventional wet mwthods becomes more essential in semiconductor industry due the confrontation of new challenges such as significant device shrink, environmental foralum inum do not work for copper as a new interconnection material, and more effective cleaning tools are required with decreasing the feature size less than 0.13 ㎛ as well as increasing the wafer size from 200 ㎜ to 300 ㎜. In this article, various cleaning techniques increasing laser cleaning are compared methodolgically hi order to understand their unique characteristics such as advantages and disadvantages according to the current clean ing issues. In particular, the current state of art of laser technique for semiconductors md prospects as a try cleaning method are described.

  • PDF

NAND 플래시 메모리용 파일 시스템 계층에서 프로그램의 페이지 참조 패턴을 고려한 캐싱 및 선반입 정책 (Caching and Prefetching Policies Using Program Page Reference Patterns on a File System Layer for NAND Flash Memory)

  • 김경산;김성조
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.777-778
    • /
    • 2006
  • In this thesis, we design and implement a Flash Cache Core Module (FCCM) which operates on the YAFFS NAND flash memory. The FCCM applies memory replacement policy and prefetching policy based on the page reference pattern of applications. Also, implement the Clean-First memory replacement technique considering the characteristics of flash memory. In this method the decision is made according to page hit to apply prefetched waiting area. The FCCM decrease I/O hit frequency up to 37%, Compared with the linux cache and prefetching policy. Also, it operated using less memory for prefetching(maximum 24% and average 16%) compared with the linux kernel.

  • PDF

연X선 Ionizer에 의한 대전물체의 제전특성에 관한 연구 (A Study of De-electrification Characteristics of Charged Body By Soft X-Ray Ionizer)

  • 이동훈
    • 한국안전학회지
    • /
    • 제13권3호
    • /
    • pp.67-73
    • /
    • 1998
  • The technology for neutralizing static electricity by soft X-ray radiation has been newly developed. This technology involves ionization of gas molecules in the vicinity of a charged substrate to generate ions and electrons to reduce electrostatic potential. The ULSI device substrate and liquid crystal display substrate tend to get charged instantly to a high potential level when they are handled in the manufacturing process. Soft X-ray radiation is adequate in air or $O_2$ gas at atmospheric pressure. This newly developed neutralization method is effective to be superior to the conventional technique, i.e., an ionizer by using corona discharge ,in every aspect. The new method features excellent neutralization capability and is able to completely reduce electrostatic potential to 0 V within a short time. Moreover, this is a very clean antistatic technology free from particle generation ,ozone generation, and electromagnetic noise, which are problems in using the corona discharge ionizer.

  • PDF

고주파 유도 가열 장치에서 피가열체의 형상 결정 (Shape Modelling of Levitated Molten Metal in Axisymmetric Induction Beating System)

  • 서춘덕;이흥배;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.954-956
    • /
    • 1993
  • This paper describes the process of levitation melting of metals in an axisymmetric induction heating system. This process has advantages of low heat losses, heating with short times and clean operating conditions. The shape of molten metal is determined using sensitivity analysis and optimization technique. Electromagnetic, gravitational and surface tension energies are considered, and these energies are used as an objective function in optimization process. Electromagnetic field are calculated using the finite element method. The fact that volume is constant in the process is also considered as an equality constraint.

  • PDF

머신러닝 기반의 온실 제어를 위한 예측모델 개발 (Development of Prediction Model for Greenhouse Control based on Machine Learning)

  • 김상엽;박경섭;이상민;허병문;류근호
    • 디지털콘텐츠학회 논문지
    • /
    • 제19권4호
    • /
    • pp.749-756
    • /
    • 2018
  • 본 연구는 머신러닝 기법을 이용한 온실 제어를 위한 예측모델을 개발하는 것이 목적이다. 시설원예연구소의 실험온실에서 측정된 데이터(2016년)를 사용하여 예측모델을 개발하였다. 모델의 예측성능 향상과 데이터의 신뢰성 확보를 위해 상관관계분석을 통해 데이터의 축소를 수행하였다. 데이터는 계절별 특성을 고려하여 봄, 여름, 가을 및 겨울로 나누어 구축하였다. 머신러닝 기반의 예측모델로 인공신경망, 순환신경망 및 다중회귀모델을 구축하고 비교분석을 통해 타당성을 평가하였다. 분석 결과에서, Selected dataset에서는 인공신경망 모델이 Full dataset에서는 다중회귀모델이 좋은 예측성능을 보였다.

금속광산지역 오염 토양/지하수의 복원기술 동향 (Emerging Remediation Technologies for the Contaminated Soil/Groundwater in the Metal Mining Areas)

  • 김경웅
    • 자원환경지질
    • /
    • 제37권1호
    • /
    • pp.99-106
    • /
    • 2004
  • 환경오염저감 및 제어기술은 환경/방재 기술분야로 포스트 반도체 주력산업의 고도화분야에 해당되며, 그 중 오염토양 및 지하수 복원기술은 앞으로 많은 수요가 예상되는 핵심기술이라 할 것이다. 국내의 경우 폐금속광산이 다수 존재하며 이로 인한 중금속 및 비소오염문제가 심각해지고 있는 시점에서 이를 복원하기 위한 최신기술의 동향을 알아보는 것이 필요할 것이다. 현재 이 분야의 선진국인 미국 및 유럽각국에서의 기술개발은 2차적인 오염을 유발하지 않을 청정기술의 개발과 개발기술의 현장적용에 초점이 맞추어 지고 있는 추세이다. 여기에 최근에 개발되어진 신기술중에 이러한 장점으로 인해 주목받고 있는 기술인 전기동력학 기술, 투수성 반응벽체기술, 고형화/안정화기술, 박테리아를 이용한 생체흡착기술, 박테리아를 이용한 용출기술, 식물정화기술을 소개하고자 한다.

Impacts of Fouling and Cleaning on the Performance of Plate Fin and Spine Fin Heat Exchangers

  • Pak, Bock-Choon;Baek, Byung-Joon;Eckhard A. Groll
    • Journal of Mechanical Science and Technology
    • /
    • 제17권11호
    • /
    • pp.1801-1811
    • /
    • 2003
  • An experimental study was conducted to investigate the effects of air-side fouling and cleaning on the performances of various condenser coils used in unitary air-conditioning systems. A total of six condenser coils with different fin geometry and row number were tested. Performance tests were performed at three different conditions: clean-as-received, after fouling, and after cleaning. In all cases, it was observed that the fouling was mostly confined to the frontal face of the heat exchanger as reported in the previous investigations. The amount of deposited dust was more dependent on fin geometry for the single-row heat exchangers than for the double-row heat exchangers. The predominant effect of fouling was to cause a more significant increase in air-side pressure drop than a degradation in heat transfer performance. For the single-row heat exchangers, the pressure drop increased by 28 to 31%, while the heat transfer performance decreased by 7 to 12% at the standard air face velocity of 1.53 m/s depending on fin shape. For the double-row heat exchangers, the pressure drop increased by 22 to 37%, and heat transfer performance decreased by only 4-5% at the same air face velocity. Once the contaminated coils were cleaned according to the given cleaning procedure the original performance of the heat exchangers could almost be recovered completely. The pressure drop could be restored within 1 to 7% and the heat transfer performance could be recovered to within 1 to 5% of the originally clean heat exchangers. Therefore, it is concluded that a periodic application of the specified cleaning technique will be effective in maintaining the thermal performance of the condenser coils.