• Title/Summary/Keyword: clean environment

Search Result 972, Processing Time 0.029 seconds

A Study on the Legal Nature of the Duty to Arrange Spill Clean-up Equipment and the Issue on the Justification of Its Privatization (방제선 등 배치의무의 법적 성질 및 민간개방의 정당성에 관한 연구)

  • Lee, Jung Won
    • Ocean policy research
    • /
    • v.33 no.2
    • /
    • pp.83-119
    • /
    • 2018
  • Under the Korean Marine Environment Management Act (hereunder, the KMEMA), the duty to arrange spill clean-up equipments, including spill clean-up vessels, required by the article 67 of the KMEMA is in essence the provision of public goods since it is a precautionary or preventive measure for the efficient performance of oil spill cleaning up. Also the obligation to control marine pollution and the duty to arrange of anti-pollution measures imposed on polluters is the obligation imposed by the public law in accordance with "the Polluter-Pays Principle". Therefore, the execution of such obligations shall be accompanied by the minimum legal and institutional arrangements. On the other hand, judging whether to form the roles of the public and private sectors in providing public goods is basically a matter of policy decision. However, even if the private sector is allowed to participate in the provision of public goods, it is imperative that a minimum requirement be provided to secure the public interest. Although major countries allows polluters to conclude a preliminary contract with a civil anti-pollution management company, these civilian institutions are in principle constituted by the owners of oil storage facilities. Additionally it is worth noting that it operates as a non-profit organization. In particular, if the practitioner performs pollution control for commercial purposes, their profitability may depend on the size of the pollution, the period spent on pollution control, the size of the equipment and manpower mobilized in the pollution control, and so on. Considering the above problems, caution should be taken to allow marine environmental management companies to be un-limitedly entrusted with the responsibility of arranging measures such as pollution control. In order to allow the marine environmental management contractor to be entrusted for the assignment of duty to protect the marine environment, the marine environment management business should be expanded so that the marine pollutant management capacity satisfies the statutory control capacity. For this purpose, it is necessary to manage and supervise the maintenance and improvement of the control capability of the marine environment management business. It is also necessary to discuss the introduction of the grading system for the control ability of the civil control companies alike in major countries.

Robust Speech Recognition using Noise Compensation Method Based on Eigen - Environment (Eigen - Environment 잡음 보상 방법을 이용한 강인한 음성인식)

  • Song Hwa Jeon;Kim Hyung Soon
    • MALSORI
    • /
    • no.52
    • /
    • pp.145-160
    • /
    • 2004
  • In this paper, a new noise compensation method based on the eigenvoice framework in feature space is proposed to reduce the mismatch between training and testing environments. The difference between clean and noisy environments is represented by the linear combination of K eigenvectors that represent the variation among environments. In the proposed method, the performance improvement of speech recognition systems is largely affected by how to construct the noisy models and the bias vector set. In this paper, two methods, the one based on MAP adaptation method and the other using stereo DB, are proposed to construct the noisy models. In experiments using Aurora 2 DB, we obtained 44.86% relative improvement with eigen-environment method in comparison with baseline system. Especially, in clean condition training mode, our proposed method yielded 66.74% relative improvement, which is better performance than several methods previously proposed in Aurora project.

  • PDF

The Implementation of Natural Gas Pipeline and Power Systems Interconnection for Power Economy And Clean Environment in North-Eastern Asia Region (동북아지역의 전력경제와 청정환경을 위한 천연가스파이프라인 및 전력계통연계의 추진)

  • Yoon, Kap-Koo;SunWoo, Hyun-Bum
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.248-252
    • /
    • 1998
  • The ACE Engineering, Inc. (ACE) of Seoul, Korea and The Energy Systems Institute (SEI) of Irkutsk, Russia has extensively studied the formation of an interconnected electric power systems throughout the North Eastern Asia Region(NEAR). The region encompasses East Siberia (ESR), Far East of Russia(FER), North East China(NEC), Mongolia(MON), North Korea(NKOR), South Korea(SKOR). Although geographically adjacent to each other, these countries and territories have different levels and rates of economic development, possess different reserves of energy resources which complement each other and hence, can interact to their mutual benefits. This Project is called Peace Network Project (PNP) because it seems to contribute for development of power economy and clean environment. In a word, the PEACE Network is expected to serve as "Power Economy And Clean Environment Network" and to promote the international cooperation. to expedite the peaceful reunification of North & South Korea and to revive the Korean culture in the North, and eventually contribute to the human prosperity.

  • PDF

Determination of Antibiotic Residues: I. Extraction and Clean-up Methods for Solid Samples_A Review (시료 중 잔류 항생제 분석 방법: I. 고상 시료 전처리 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.600-627
    • /
    • 2016
  • Korea is one of the countries with a large veterinary antibiotics market, although antimicrobial resistance in bacteria is becoming a serious issue in many countries. The Korean government started to take interest in estimating the effects of livestock manure on rivers and agricultural soils and in monitoring of heavy metals, organic pollutants and antibiotics in the ambient water and soil. In this paper, pre-treatment methods to separate the selected antibiotics from solid samples were reviewed. It is essential to select an efficient and appropriate procedure for pre-treatment due to the high proportion of proteins and organics in biosolid samples. Pre-treatment consists of extraction followed by clean-up. Initially, homogenized samples were extracted by sonication, mechanical agitation or pressurized liquid extraction with methanol/acetonitrile/water mixture under acidic/basic conditions depending on the compound. However, aminoglycosides and colistin were extracted with 5% trichloroacetic acid and HCl, respectively. Since the ${\beta}-lactams$ are easily decomposed in acidic and basic conditions, they were extracted in neutral pH. Filtration with a membrane (pore size, $0.2{\mu}m$) or solid phase extraction with HLB and methanol, as eluents, was normally applied for the clean-up. At least, three different pre-treatment procedures should be adopted to screen all the selected antibiotics in solid samples.

Effect of Differences between Korean Ministry of Environment Standard and ISO Standard on Determination of Petroleum Hydrocarbon Content in Soil (토양오염공정시험기준과 국제표준간의 분석방법 차이가 유류 정량에 미치는 영향)

  • Jung, In-Ho;Lee, Goon-Taek;Lee, Won-Seok;Kim, Yong-Hoon;Kim, Bo-Hyun;Kim, Ji-In;Kim, Bo-Kyong
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.4
    • /
    • pp.63-72
    • /
    • 2012
  • The main objective of this study is to assess the compatibility between Korean ministry of environment (KME) standard and ISO (KS I ISO) standard for the determination of BTEX and TPH content in soil. We carried out comparison analysis for both methods using CRM and matrix spiked samples. In case of GC-MS analysis for BTEX, we got statistically (significance level: 0.05) the same results from KME standard (ES 07600.1) and ISO standard (KS I ISO 15009). However, it showed statistically (significance level: 0.05) different results when TPH was analyzed by KME standard (ES 07552.1) and ISO standard (KS I ISO 16703). To clarify the reason why both methods produced different results for TPH content, we also did some additional experiments in terms of differences in extraction, clean-up and target hydrocarbon range. Extraction with polar and non-polar compounds mixed solvent (acetone+n-heptane) of KS I ISO 16703 showed higher extraction efficiency than with only non polar solvent (dichloromethane) extraction of ES 07552.1 by about 9%. While column type clean-up of KS I ISO 16703 showed the reduction in TPH content between before and after clean-up, batch type of clean-up of ES 07552.1 did not show any changes in TPH content through clean-up process. The target hydrocarbon range of ES 07552.1 and KS I ISO 16703 is $C_8{\sim}C_{40}$ and $C_{10}{\sim}C_{40}$, respectively. From this point of view, kerosene and JP-8 contaminated soil showed higher RPD (relative producibility deviation) values between results by both method than that of lubricant or diesel contaminated soil. The higher content of hydrocarbon ($C_8{\sim}C_{10}$) in kerosene and JP-8 played an important role in increasing RPD values in addition to the effects caused by different solvents and clean-up method. Consequently, it was concluded that both methods (ES 07552.1 and KS I ISO 16703) were not compatible.

A Study on Clean Agent Fire Extinguishing Ability Using Nitrogen and Novec Mixtures Gas (질소와 노벡 혼합가스를 이용한 청정소화약제의 소화성능에 관한 연구)

  • Lim, Woo-Sub;Jung, Jong-Jin;Nam, Dong-gun;SaKong, Seong-Ho;Kim, Jong-Won;Choi, Kenu-Joo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.76-83
    • /
    • 2008
  • In the course of increasing in human and material damage caused by fire, it is an important research field to develop clean extinguishing agent which does no harm to global environment as well as has a good extinguishing efficiency. This research is a basic step to develop a new clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using nitrogen and Novec mixtures gas which are inert gas and new clean extinguishing agent. We used Cup Burner Test made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test, and the fuels used in the test are n-heptane, methanol, ethanol, iso-propanol and 1-butanol. The experimental results of flame extinguishing concentration are n-heptane 6.54%, methanol 8.47%, ethanol 6.98%, isopropanol 6.10% and butanol 6.54% by pure Novec agent. So the finding is that a new clean agent, Novec has an efficient extinguishing ability in a state of gas. Also, in a test as to mixtures gas of nitrogen and Novec, it has a good result for minimum oxygen concentration is under 16%.

A Study on the Map-Building of a Cleaning Robot Base upon the Optimal Cost Function (청소로봇의 최적비용함수를 고려한 지도 작성에 관한 연구)

  • Kang, Jin Gu
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.3
    • /
    • pp.39-45
    • /
    • 2009
  • In this paper we present a cleaning robot system for an autonomous mobile robot. Our robot performs goal reaching tasks into unknown indoor environments by using sensor fusion. The robot's operation objective is to clean floor or any other applicable surface and to build a map of the surrounding environment for some further purpose such as finding the shortest path available. Using its cleaning robot system for an autonomous mobile robot can move in various modes and perform dexterous tasks. Performance of the cleaning robot system is better than a fixed base redundant robot in avoiding singularity and obstacle. Sensor fusion using the clean robot improves the performance of the robot with redundant freedom in workspace and Map-Building. In this paper, Map-building of the cleaning robot has been studied using sensor fusion. A sequence of this alternating task execution scheme enables the clean robot to execute various tasks efficiently. The proposed algorithm is experimentally verified and discussed with a cleaning robot, KCCR.

Relationship of Electricity Consumption and Emission Rate of Acidic Gases (전력소비와 산성가스 배출량과의 관계)

  • 정일록;김대곤
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.131-138
    • /
    • 1995
  • As the energy consumption increases continuously, the emission amount of air pollutants is growing, and after all it can influence the global environment as welt as the regional atmosphere. So, the clean energy which emits less air pollutants should be developed and widely used to reduce emission of pollutants. Electricity, known for clean energy in the side of consumption, is not actually clean in the process of generation. Electric power is generated using fossil fuels which produce acidic gases like $SO_{2}$, $NO_{x}$, etc. The emission rates of $SO_{2}$, $NO_{x}$, $CO_{2}$ are 2g,0.78g and 1 l0g per electric power generating Ikwh. If one light(60 watt bulb) be turned off at each house for a month electricity will be saved about 1.Skillion kwh a year. This is almost the same as 4,170 tons of $SO_{2}$ and $NO_{x}$. As a result the economization of electricity will be one of the effective strategy to reduce the air pollution and to keep our life clean and comfortable.

  • PDF

A Case Study on the Ventilation System of the General hospital (종합병원의 환기설비 사례 연구)

  • Jung, Jong-Rim
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.187-194
    • /
    • 2004
  • In many other buildings, hospital is very important because of its function and purpose. A proper building service systems including heating, cooling, ventilation and plumbing systems is required in hospial. Besides, a special systems like medical gas, vacuum cleaning systems are required to prevent contamination as well as cure a patient in hospital. Ventilation is very important method to keep the indoor pressure and clean class. There are some specific rooms to consider clean class and indoor pressure in the general hospital. In this article, specific rooms were set to operating room, laboratory, ICU, isolation unit, and sterilizer room. In this case study, design factors of ventilation system, including air changes of OA and TA, indoor pressure, clean class, filter, and material of system, of specific rooms in hospital were proposed through a literature research and a design examples review.

Hebei Spirit Oil Spill Exposure and Subjective Symptoms in Residents Participating in Clean-Up Activities

  • Cheong, Hae-Kwan;Ha, Mi-Na;Lee, Jong-Seong;Kwon, Ho-Jang;Ha, Eun-Hee;Hong, Yun-Chul;Choi, Ye-Yong;Jeong, Woo-Chul;Hur, Jong-Il;Lee, Seung-Min;Kim, Eun-Jung;Im, Ho-Sub
    • Environmental Analysis Health and Toxicology
    • /
    • v.26
    • /
    • pp.7.1-7.9
    • /
    • 2011
  • Objectives: This study was conducted to examine the relationship between crude oil exposure and physical symptoms among residents participating in clean-up work associated with the Hebei Spirit oil spill, 2007 in Korea. Methods: A total of 288 residents responded to a questionnaire regarding subjective physical symptoms, sociodemographic characteristics and clean-up activities that occurred between two and eight weeks after the accident. Additionally, the urine of 154 of the respondents was analyzed for metabolites of volatile organic compounds (VOCs) and polycyclic aromatic hydrocarbons (PAHs) and heavy metals. To compare the urinary levels of exposure biomarkers, the urine of 39 inland residents who were not directly exposed to the oil spill were analyzed. Results: Residents exposed to oil remnants through clean-up work showed associations between physical symptoms and the exposure levels defined in various ways, including days of work, degree of skin contamination, and levels of some urinary exposure biomarkers of VOCs, metabolites and metals, although no major abnormalities in urinary exposure biomarkers were observed. Conclusions: This study provides evidence of a relationship between crude oil exposure and acute human health effects and suggests the need for follow-up to evaluate the exposure status and long-term health effects of clean-up participants.