• Title/Summary/Keyword: class-C inverter

Search Result 18, Processing Time 0.03 seconds

Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant (원자력발전소 직류전원계통용 축전지 성능시험 분석)

  • Kim, Daesik;Cha, Hanju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.

The development of 20 KW battery energy storage system (20 KW 전력저장전지시스템 개발)

  • Ko, Yo;Song, B.M.;Kim, J.E.;Kim, H.Y.;Eom, Y.C.
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.206-209
    • /
    • 1990
  • The battery energy storage system has been studied and adopted actively by foreign advanced utilities to use off-peak energy. Korea electro-technology research institute & KEPCO developed a small scale battery energy storage system. This system is composed of a voltage type self commutating inverter and 180 cells of 500 AH lead acid battery. Using the result of operation of the system, we make a conceptual design of MW class system.

  • PDF

Development of 100cc Electric Motorcycle using In-Wheel Type IPMSM (IPMSM을 이용한 110cc급 전기 이륜차 개발)

  • Kim, Y.K.;Eom, D.S.;Kim, Y.R.;Hong, C.H.;Kim, Y.G.;Mok, H.S.
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.107-108
    • /
    • 2011
  • This paper developed 110cc class electric motorcycle using IPMSM. First, Tractive effort calculated by considering the driving environment of motorcycle. And accordingly the motor and inverter were designed and manufactured. It was mounted on motorcycles and test result was compared with the output power of motorcycle with an internal combustion engine.

  • PDF

Research of Degradation Properties on Stator Coil of Traction Motor (견인전동기 고정자 코일의 열화특성 연구)

  • Jang, Dong-Uk;Byun, Yeun-Sub;Wang, Jong-Bae;Park, Hyun-June;Kim, Gil-Dong;Han, Young-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1430-1432
    • /
    • 2001
  • In this paper, 200-class insulation system for form-wound stator coils is designed for form-wound stator coils is designed for AC traction driven with VVVF inverter. Model coils are made to embody all essential elements representing a winding insulation system and structure. Acceleration degradation for model coils is applied exposure to heat(235$^{\circ}C$). In order to investigate the condition of the coils and to determine their insulation reliability, high voltage test and the dielectric properties such as dielectric loss and capacitance are performed. Also, partial discharge measurement is investigated for internal defects.

  • PDF

Condition Diagnosis by the Complex Accelerating Degradation for Fault Prediction & Estimation of Reliability on the Traction Motor - Dielectric loss and PD Properties according to High Voltage (견인전동기의 고강예측 및 신뢰성 평가를 위한 복합가속열화 상태진단 - 고전압 인가에 따른 유전손실 및 부분방전 특성 연구)

  • Wang, Jong-Bae;Baek, Jong-Hyen;Byun, Yoon-Sub;Park, Hyun-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1371-1373
    • /
    • 2000
  • In this paper, the complex accelerating degradation of traction motor driven with VVVF controlled inverter were performed on the form coil samples with the 200 Class insulation system. in order to evaluate the reliability and the long-term life. After aging, the dielectric and PD properties were investigated on the 10 cycles aging sample in the range of $20{\sim}160[^{\circ}C]$ and AC $250{\sim}2250[V]$ to diagnosis the condition of end-life and find the dominative factors of degradation.

  • PDF

A study on 7528W Class Fluorescent Lamp Ballast using a Piezoelectric Transformer by means of Onechip Microcontroller (Onechip Microcontroller에 의한 압전 변압기를 이용한 T5 28W급 형광등 전자식안정기에 관한 연구)

  • Hwang L. H.;Shin Y. H.;Cho S. R.;Jang E. S.;Cho M. T.;Ahn I. S.;Kim J. R.
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.228-232
    • /
    • 2002
  • In this paper, In order to solve the problem is proposed using a new type of electronic ballast that the traditional magnetic ballasts operated at 50-60Hz have been suffered from noticeable flicker, high loss, large crest factor and heavy weight which is composed of rectifier, active power corrector, series resonant half bridge inverter, micro-controller and piezoelectric transformer for driving for driving T5 fluorescent lamp were manufactured. The proposed electronic ballast operated at high frequency (about 75kHz) shows a input power factor of more than 0.995, total harmonic distortion of less than $12\%$ and lamp current crest factor of less than 1.5, respectively. Output power and efficiency showed 28w and $85\%$, respectively. Accordingly, it is considered that the ballast using piezoelectric transformer can replace the typical electronic ballast.

  • PDF

2MHz, 2kW RF Generator (2MHz, 2kW RF 전원장치)

  • Lee J.H.;Choi D.K.;Choi S.D.;Choi H.Y.;Won C,Y.;Kim S.S
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.260-263
    • /
    • 2003
  • When ICP(Inductive Coupled Plasma type etching and wafer manufacturing is being processed in semiconductor process, a noxious gas in PFC and CFC system is generated. Gas cleaning dry scrubber is to remove this noxious gas. This paper describes a power source device, 2MHz switching frequency class 2kW RF Generator, used as a main power source of the gas cleaning dry scrubber. The power stage of DC/DC converter is consist of full bridge type converter with 100kHz switching frequency Power amplifier is push pull type inverter with 2MHz switching frequency, and transmission line transformer. The adequacy of the circuit type and the reliability of generating plasma in various load conditions are verified through 50$\Omega$ dummy load and chamber experiments result.

  • PDF

Development of the 3kW Class Low Cost Fuel Inverter System for Residential Power Generation - DC-DC Converter Design and Control for Fuel Cell System (3kW급 주택용에 사용되는 저가의 연료전지용 인버터 시스템 - 연료전지 시스템용 DC-DC 컨버터 설계 및 제어)

  • Lee, S.H.;Cho, M.C.;Hwang, G.D.;Mun, S.P.;Suh, K.Y.;Kwon, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1161-1162
    • /
    • 2006
  • 본 논문은 3[kW]급 연료전지와 연료전지의 저전압$[40{\sim}60[Vdc]$)을 승압(380vdc)하기 위한 풀-브리지 DC-DC 컨버터, 그리고 승압된 링크전압을 교류 상용전압(220[Vac], 60[Hz)으로 변환하기위한 단상 풀-브리지 인버터로 구성된 연료전지 발전용 전력변환시스템 중 연료전지 시스템용 DC-DC 컨버터를 제안하였다. 제안한 연료전지 시스템용 DC-DC 컨버터는 변압기 2차측에 배전류 정류회로를 삽입하여 기존의 고주파 변압기 보다 간단하면서 무게 및 부피를 줄였다. 그리고 위상 천이 PWM 제어로 출력 전압을 가변시켜 영전압 스위칭을 달성 함으로써 스위칭 손실을 줄였으며. 효율을 95%이상 달성 하였다.

  • PDF