• Title/Summary/Keyword: clamping pressure

Search Result 89, Processing Time 0.026 seconds

Influence of clamped-clamped boundary conditions on the mechanical stress, strain and deformation analyses of cylindrical sport equipment

  • Yuhao Yang;Mohammad Arefi
    • Geomechanics and Engineering
    • /
    • v.35 no.5
    • /
    • pp.465-473
    • /
    • 2023
  • The higher order shear deformable model and an exact analytical method is used for analytical bending analysis of a cylindrical shell subjected to mechanical loads, in this work. The shell is modelled using sinusoidal bivariate shear strain theory, and the static governing equations are derived using changes in virtual work. The eigenvalue-eigenvector method is used to exactly solve the governing equations for a constrained cylindrical shell The proposed kinematic relation decomposes the radial displacement into bending, shearing and stretching functions. The main advantage of the method presented in this work is the study of the effect of clamping constraints on the local stresses at the ends. Stress, strain, and deformation analysis of shells through thickness and length.

Comparison of Hemodynamic Energy between Expanded Polytetrafluoroethylene and Dacron Artificial Vessels

  • Lim, Jaekwan;Won, Jong Yun;Ahn, Chi Bum;Kim, Jieon;Kim, Hee Jung;Jung, Jae Seung
    • Journal of Chest Surgery
    • /
    • v.54 no.2
    • /
    • pp.81-87
    • /
    • 2021
  • Background: Artificial grafts such as polyethylene terephthalate (Dacron) and expanded polytetrafluoroethylene (ePTFE) are used for various cardiovascular surgical procedures. The compliance properties of prosthetic grafts could affect hemodynamic energy, which can be measured using the energy-equivalent pressure (EEP) and surplus hemodynamic energy (SHE). We investigated changes in the hemodynamic energy of prosthetic grafts. Methods: In a simulation test, the changes in EEP for these grafts were estimated using COMSOL MULTIPHYSICS. The Young modulus, Poisson ratio, and density were used to analyze the grafts' material properties, and pre- and post-graft EEP values were obtained by computing the product of the pressure and velocity. In an in vivo study, Dacron and ePTFE grafts were anastomosed in an end-to-side fashion on the descending thoracic aorta of swine. The pulsatile pump flow was fixed at 2 L/min. Real-time flow and pressure were measured at the distal part of each graft, while clamping the other graft and the descending thoracic aorta. EEP and SHE were calculated and compared. Results: In the simulation test, the mean arterial pressure decreased by 39% for all simulations. EEP decreased by 42% for both grafts, and by around 55% for the native blood vessels after grafting. The in vivo test showed no significant difference between both grafts in terms of EEP and SHE. Conclusion: The post-graft hemodynamic energy was not different between the Dacron and ePTFE grafts. Artificial grafts are less compliant than native blood vessels; however, they can deliver pulsatile blood flow and hemodynamic energy without any significant energy loss.

Performance assessment of Magnesium Bipolar Plates for Light Weight PEM Fuel Cell (PEM 연료전지 경량화를 위한 마그네슘 분리판의 성능평가)

  • Park, To-Soon;Lee, Dong-Woo;Kim, Kyung-Hwan;Kwon, Se-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.12
    • /
    • pp.1063-1069
    • /
    • 2012
  • In present paper, we used magnesium alloy having a lower density and higher electrical conductivity for bipolar plate to reduce the weight of PEM fuel cell. The silver was coated to prevent corrosion and form passivation film on the metal surface with sputtering. In acid proof evaluation for setting optimal coating conditions, the homogeneity of coating thickness was improved by coating with the thickness of 3 ${\mu}m$ which not indicated any micro cracks and the temperature $180^{\circ}C$. The performance test and evaluation based on the clamping pressure and channel depth to determine the configuration of bipolar plate for assembling single cell was implemented. And then we assembled single cell with this bipolar plate and implemented the performance test to ensure and compare the current-voltage performance followed as several factors such as coating or non-coating, the change of clamping pressure, the change of channel depth, etc. As these results, the maximum power density of single cell with the coated bipolar plate was 192 $mW/cm^2$ and it was confirmed that the power density per unit mass was better than existing metal bipolar plate.

Thoracoabdominal Aortic Aneurysm Repair after Renal Transplantation (신장 이식후 발생한 해리성 흉복부 대동맥류의 외과적 치험)

  • 김대영;문광덕
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.449-453
    • /
    • 1996
  • A successful resection of dissecting thoracoabdominal aortic aneurysm is presented in a patient who had undergone kidney transplantation 20 months previously. Because the transplanted kidney is more sensitive to ischemia than the normal kidney, a femoro-femoral bypass with a pump oxygenator was used for perfusion of the transplanted kidney during crossclamping. During the clamping time of 1)8 minutes, kidney perfusion was maintai ed with a perfusion pressure of (19 to 31) 27mmHg and the flow was 0.53 to 0.81 L/min. 32mm sized Hemashield (22 Cm in length) was interposed. The postoperative course was uncomplicated. We believe that performing the femoro- femoral bypass with a pump oxygenator is an effective and simple method for renal and spinal protection in such operations.

  • PDF

Successful Correction of Coarctation of the Aorta, the Patent Ductus Arteriosus, and Persistent Left Superior Vena Cava (대동맥축착 동맥관개존 좌공정맥을 합병한 다발성혈관기형의 수술치험예)

  • 김근호
    • Journal of Chest Surgery
    • /
    • v.7 no.1
    • /
    • pp.93-100
    • /
    • 1974
  • This is a case report of successful surgical correction of coarctation of the aorta associated with the patent ductus arteriosus and the persistent left superior vena cava. The patient was a 15 year old girl and congenital heart anomaly was suspected at the sixth month after birth. Afterward there has been no embarrassing symptoms until the day of operation except slight dyspnea on exertion, The diagnosis of coarctation of the aorta and the patent ductus arteriesus detected by physical signs and X-ray studies including aortography. In the first place, coarctation of the aorta was corrected with following procedure: partial resections of the aortic wall just above and below the coarctating line of the aorta and removal of diaphragmatic structure of coarctation performed by. cross clamping aorta above and below coarctation, and then the defect of the aortic wall was closed by lateral aortorrhapic suture with atraumatic needle 3-0 silk continuously [Fig. 6]. In the second place, the patent ductus arteriosus was closed with double ligation method. The persistent left superior vena cava left as it has been, because there has been no evidence of hemodynamic abnormal shunt. After operation, excellent result was obtained; blood pressure in the upper and lower extremities was normalized and subjective complains of hypertension in the upper extremity was disappeared.

  • PDF

Design of Gate Location in Injection Molding of a Dashboard Using Dummy Runner (모조 러너를 이용한 계기판 사출성형의 게이트 위치 설계)

  • Han, Gyeong-Hui;Choe, Du-Sun;Kim, Hong-Seok;Im, Yong-Taek
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.10
    • /
    • pp.1575-1582
    • /
    • 2001
  • Injection molding is widely used in producing various plastic parts due to its high productivity, and the demand for injection molded products with high precision is increasing. To achieve successful product quality and precision, the design of gating and runner system in injection mold is very important because it influences the melt flow into the cavity. Some deflects, such as weld lines and overpacking, can be effectively controlled with proper selection of gate locations. In the present study, the design of gate locations in injection molding of a dashboard fur automobiles was carried out with CAMP mold, a PC-based simulation system for injection molding. A dummy runner system was developed to simulate a runner system in order to increase the efficiency of the analysis procedure. The numbers and locations of gates were iteratively determined in the present investigation. In this procedure, an acceptable design was obtained in terms of reducing the maximum pressure and clamping force.

Application of Sea Algae Fiber for the Improvement of Compressibility and Physical Properties of Letter Press Printing Paper (활판 인쇄용지의 압축성 및 물리적특성 향상을 위한 해조류 섬유의 적용)

  • Kim, Byong-Hyun;Seo, Yung-Bum
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.40 no.1
    • /
    • pp.15-22
    • /
    • 2008
  • For the improvement of letterpress printing paper quality, special fibers obtained from the sea were used by mixing with wood fibers. The sizes of the special fibers, which were from red algae in the sea, were 0.5-1 mm in length, and 3-7 ${\mu}m$ in width, respectively, and the fibers were supplied by Pegasus Research Inc. for the study. From the study, it was found that 10% addition of algae fibers greatly improved paper surface strength and internal bonding strength. The compressibility was estimated by utilizing 'Print-surf method' at high clamping pressure and with hard backing. Again, 10% addition of algae fibers greatly improved the compressibility of the paper. These results were expected that algae and wood fibers were distributed evenly through the sheet, and integrated one another to leave no empty space inside the paper.

Clinical Study of Ventricular Function Following Open Heart Surgery by Radionuclide Angiocardiogram - left ventricular ejection fraction by ECG gated blood pool scan - (방사성 동위원소를 이용한 개심술 전후의 심실기능 변화에 관한 연구: ECG gated blood pool scan을 이용한 ejection fraction 검사)

  • Lee, Jeong-Cheol;Kim, Gyu-Tae
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.25-34
    • /
    • 1986
  • Recently, radionuclide angiocardiogram is one of the most common procedure for assessment of ventricular performance due to its distinctive advantages such as safety, accuracy, and ease of repeated studies. Also, measurement and comparison between pre and postoperative left ventricular ejection fraction [LVEF] are meaningful for assessing the severity of myocardial damage which occurred during open heart surgery and the status of myocardial recovery. We obtained pre and post operative LVEF using radionuclide angiocardiogram on 30 patients composed of atrial septal defect, ventricular septal defect, cyanotic congenital heart disease, and valvular heart disease who undergone the open heart surgery from March to august 1984. The study revealed that ventricular septal defect and mitral valvular heart disease showed 8.1% and 6.2% decreases of postoperative LVEF, respectively. But, there are little increases of postoperative LVEF in the atrial septal defect and cyanotic congenital heart disease. In ventricular septal defect, each group of Qp/Qs over 2.0 and systolic pulmonary artery pressure over 50mmHg showed significant 17% and 14.7% decreases of postoperative LVEF, respectively. Considering the duration of the aortic cross clamping times and closing methods of VSD, each group of duration over 30 min. and of patch closure showed 13.9% and 14.2% decreases of LVEF between pre and postoperative status respectively which was significant finding statistically.

  • PDF

Complications after Senning Operation for TGA with and Wothout VSD (대혈관전위증에서 Senning수술후 합병증에 관한 임상적 고찰)

  • 안재호
    • Journal of Chest Surgery
    • /
    • v.26 no.8
    • /
    • pp.595-603
    • /
    • 1993
  • We analysed 60 consecutive patients who got Senning operation for transposition of the great arteries [TGA] with or without ventricular septal defects [VSD]. There were 41 simple TGA [group I] and 19 TGA with VSD [Group II], the operative mortality was 20 % [in group I 4.9 %, group II 52.6 %]. Among the survivors [n=48], the mean follow-up period was 7 years [range, 1 year to 13.5 years] and the actuarial survival rate at 13 years were 95 % in group I and 42 % in group II. Preoperative high left ventricular pressure and high pulmonary arterial pressure affected the surviving [p<0.01]. There occurred various type of arrhythmia like junctional rhythm, first degree atrioventricular [AV] block, sick sinus syndrome and complete AV block, and we inserted 2 permanent pacemakers for these patients. The incidence of arrhythmia were 28.2 % [11/39] in group I and 55.6 % [5/9] in group II, and the actuarial freedom from arrhythmia at 13 years after operation was 66 % [71 % in group I, 44 % in group II]. Increased aortic cross clamping time had affected the development of arrhythmia [p<0.05] which meant the complexity of the operation. The total incidence of left ventricular outflow tract obstruction [LVOTO] was 31.3 % [15/48], but only 3 patients [6.25 %] showed the significant gradient requiring reoperation. The pulmonary venous pathway obstruction [PVO] were found in 3 patients, all in group I, and among them only one required the reoperation. The estimated freedom from PVO was 89 % at 13 years [87 % in group I, 100 % in group II], but we couldn`t find any significant systemic venous obstruction in our series. There occurred 27.1 % [13/48] mild degree tricuspid valve regurgitation without necessary surgical correction. We experienced 14.6 % [7/48] reoperation rate: 3 residual VSD, 3 LVOTO, 1 PVO, 3 atrial baffle leakage. For this high incidence of complication rate after Senning operation and high mortality in TGA with VSD, We do not use this kind of surgical modality any more and do the Jatene operation for all the TGA patients since several years ago.

  • PDF

Open Heart Surgery for Six Cases of the Conegnital Heart Disease (선천성(先天性) 심장병(心臟病)의 개심술(開心術) -6례(例) 수술경험(手術經驗) -)

  • Lee, Sung Haing;Lee, Sung Koo;Han, Sung Sae;Lee, Kihl Rho;Kim, Song Myung;Lee, Kwang Sook;Lee, Chong Kook
    • Journal of Chest Surgery
    • /
    • v.9 no.2
    • /
    • pp.220-238
    • /
    • 1976
  • Six cases of congenital heart disease were operated on by means of cardiopulmonary bypass between December, 1975 and April, 1976. Two cases of ventricular septal defects (VSD), two cases of VSD, associated with ruptured aneurysm of sinus Valsalva, two cases of atrial septal defects (ASD) and one case of pulmonic stenosis with patent ductus arteriosus were operated. Sarns roller pumps and Bentley Temptrol oxygenators were used for extracorporeal circulation. Pump oxygenator was primed with Ringer's lactate solution, 5% dextrose in water, mannitol, and ACD blood. Flow rate ranged from 2.0 to $2.4L/M^2/min$. Bicarbonate was added to the oxygenator with estimated amount as 15 mEq/L/hr. Venous catheters were introduced into superior and inferior vena cava, and oxygenated blood was returned to the body through aortic cannula inserted into ascending aorta. Moderate hypothermia ($30^{\circ}C$) was induced by core cooling. Aorta was cross clamped for 15 minutes and released for 3 minutes, and repeated clamping when necessary. Atrial and ventricular septal efects were closed by direct sutures. Aneurysms of sinus Valsalva ruptured into the right ventricle were repaired through right ventriculotomy by d:rect closure with Dacron patch reinforcement. Cardiopulmonary bypass time varied from 66 to 209 minutes, and aorta cross clamping time ranged from 13 to 56 minutes. Postoperative bleeding was minimal except one case who needed for evacuation of substernal hematoma. Intra- and postoperative urinary output was satisfactory. Acid-base balance, partial pressure of $O_2$, electrolytes, and hematological changes during intra- and post-perfusion period remained at the acceptable ranges. No mortality was experienced.

  • PDF