• 제목/요약/키워드: city safety standard

검색결과 121건 처리시간 0.02초

방재력을 고려한 도시의 풍수해 안전기준 개발방향 설정 연구 (A Study on a Direction of the Development of City on Storm and Flood Risk Safety Standards in Consideration of Resilience)

  • 김미선;신진동;심숙연;김현주
    • 한국안전학회지
    • /
    • 제30권1호
    • /
    • pp.127-136
    • /
    • 2015
  • This study has analyzed city plans and disaster prevention plans from the perspective of resilience and established a direction of the development of city safety standards. The analysis made use of the 5 functions of resilience (5Rs) and foreign cases. As a result of the analysis, the direction of the development of city safety standards was drawn from 4 perspectives at large. First, this study proposed a method of the systematization of the safety standards involved in components within city plans. Second, it suggested a method to strengthening urban resilience abilities in terms of the association between disaster prevention and city plans. Third, it found out components requiring safety standards considering foreign and other standards, and proposed a direction of complementary measures for safety standards. Lastly, it came up with a direction of the development of city safety standards, the necessity of which are required though existing plan criteria did not contain them. This study is significant in that it has defined the ultimate goal of safety a city should pursue as resilience and proposed a direction of the development of related standards.

주요선진국의 가스기술기준 체제분석 및 제도개선 발전 모형 (Analysis of Safety Decrees for Gas Safety Management System and its Development)

  • 김봉진;강경식
    • 대한안전경영과학회지
    • /
    • 제3권2호
    • /
    • pp.51-63
    • /
    • 2001
  • Korea gas industrial because of received LNG in 1987 was converted by the Gas Safety Management System in relation to city gas, LPG and LNG. Gas accident were caused by treatment problem on the supplier and user, on technical and use management mater, on facilities and goods, and included problem with gas safety connection system. This study is present standard application plan of each department to use planning gas technical standard and gas utilization standard of introduction model than statute for change of self-regulation management system and complicated regulation of examination center and order.

  • PDF

u-방재 City 기본방향 연구 (Introduction of Principles for Disaster Prevention Planning in u-City)

  • 김현주;박영진;이원성;연경환
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.127-130
    • /
    • 2008
  • This study demonstrates a basic concept and designing direction for the realisation of disaster prevention planning in u-City(u-BangjaeCity) that is from establishing a planning system in terms of the areas of professional disaster and safety management for the national disaster management. and designing disaster or safety management system via using ubiquitous technology for the scientific disaster management. In order to realise u-City it is necessary to maps out interrelation amongst various services such as traffic, environment and disaster prevention. Domestic and international case studies regarding the tendency of disaster prevention planing in u-City and its analysis could be the fundamental resource in order to develop the standard model of u-BangjaeCity.

  • PDF

공공의료기관 간호사의 감염 표준주의지침 수행도 영향요인 : 지식, 안전환경 중심으로 (Factors Affecting Nurses' Performance of Standard Precautions for Infection in Public Medical Institutions: Focusing on Knowledge and Safety Environment)

  • 이지인;김종경
    • 한국콘텐츠학회논문지
    • /
    • 제21권7호
    • /
    • pp.238-247
    • /
    • 2021
  • 본 연구는 공공의료기관에 근무하는 간호사의 감염 표준주의지침에 대한 지식, 안전환경, 수행도를 조사하고 표준주의지침에 대한 수행도에 미치는 영향 요인을 확인하기 위한 서술적 조사연구이다. 연구방법은 S시, N시의 2개의 공공의료기관 간호사 192명을 대상으로 설문지를 통해 자료를 수집하였고 SPSS WIN 22.0 통계프로그램을 사용하여 결과를 분석하였다. 연구결과 표준주의지침 지식은 근무경력에 따라 유의한 차이가 있었으며 표준주의지침 안전환경은 직위에 따라 유의한 차이가 있었다. 표준주의지침 지식 정도는 평균 21.98(25점 만점), 안전환경은 평균 5.68(7점 만점), 수행도는 평균 40.28(60점 만점)이었으며, 표준주의지침 안전환경과 표준주의지침 수행도(r=.21, p<0.01)는 유의한 양의 상관관계가 있었다. 표준주의지침 수행도에 미치는 영향요인은 표준주의지침 안전환경(𝛽=.22, p=.003)으로 나타났다. 따라서 공공의료기관에서 간호사의 감염관리를 위한 표준주의지침 수행도를 증진 시키기 위해서는 재정적 지원 및 지지적 안전환경을 제공하고 현 상황을 고려한 차별화된 감염관리 교육프로그램과 모니터링이 요구된다.

중국 자율주행차 테스트베드 관련 표준 분석을 통한 K-City 고도화 방안 수립에 관한 연구 (Study on the Development of K-City Roadmap through the Standard Analysis of the Test-Bed for Automated Vehicles in China)

  • 이상현;고한검;이현우;조성우;윤일수
    • 자동차안전학회지
    • /
    • 제14권1호
    • /
    • pp.6-13
    • /
    • 2022
  • The Ministry of Land, Infrastructure and Transport (MoLIT) and the Korean Automobile Testing and Research Institute (KATRI) are supporting the development of Lv.3 automated vehicle (hereinafter, AV) technology by constructing an automated driving pilot city (as known as K-City) equipped with total 5 evaluation environments (urban, motorway, suburban, community road, and autonomous parking facility) which is a test bed exclusively for AV (2017~2018). An upgrade project is in a progress to materialize harsh environments such as bad weather (rain, fog, etc.) and reproduction of communication jamming (GPS blocking, etc.) with the purpose of supporting the development of Lv.4 connected & automated vehicle (hereinafter, CAV) technology (2019~2022). We intend to proactively establish a national level standard for CAV test-bed and test road requirements, test method, etc. for establishment of a road map for the construction of the test bed which is being promoted step by step and analyze and, when required, benchmark the case of China that has announced and is utilizing it. Through this, we plan to define standardized requirements (evaluation facility, evaluation system, etc.) on the test bed for the development of Lv.4/4+ CAV technology and utilize the same for the design and construction of a test bed, establishment of a road map for the construction of a real car-based test environment related to the support for autonomous driving service substantiation, etc. through provision of an evaluation environment utilizing K-City, and the establishment of a K-City upgrade strategies, etc.

병원간호사의 감염예방 표준주의지침 지식, 인식, 안전환경 및 수행도에 관한 연구 (Knowledge, Perception, Safety Climate, and Compliance with Hospital Infection Standard Precautions among Hospital Nurses)

  • 서영희;오희영
    • 임상간호연구
    • /
    • 제16권1호
    • /
    • pp.61-70
    • /
    • 2010
  • Purpose: The purpose of this study was to examine knowledge, perception, safety climate and compliance with hospital infection standard precautions and to identify the factors influencing nurse's compliance with standard precautions. Methods: Using the structured survey, data were collected from 292 nurses working at 4 general hospitals in the metropolitan city Seoul in October, 2008. Data were entered and analyzed with SPSS 12.0. Results: The majority of nurses were female with a mean age of 27.8. The mean score for knowledge of standard precautions was 21.2 out of 25. The nurses lacked knowledge on reusable gloves or gowns. Nurses perceived use of protective devices may not only increase time strain but also hinder development of therapeutic relationships with patients. Of safety climate factors, lack of time was the most frequently reported barrier to compliance with standard precautions. Knowledge, perception, and safety climate explained 16.1% variance of compliance with standard precautions. Conclusion: To improve nurses' compliance with standard precautions, provision of education and support for safety climate are necessary.

국내 음용수의 안전성 (Safety of Drinking Water in Korea)

  • 권숙표
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1997년도 제5회 하계 Workshop (97 한,카 국제공동 Workshop, 고도 수처리를 위한 막분리 공정)
    • /
    • pp.1-20
    • /
    • 1997
  • The present standard of drinking water quality is not reached to the guidelines of WHO and US EPA recommended. The appraisal of safety is not appropriate by the results of intermittent and limitted analysis. 45 items of drinking water quality are regulated in the Korean standard and 9 items for inspection designated by Seoul City. This report is the results of analysis of the water quality in the water stations of Seoul which are concerned with the items of Korean water quality standard and the priolity pollutnats recommended by WHO. In the results, 45 items of water quality, and the priolity pollutants were not exceeded to the standard and criteria, while DDT, heptachlor-epoxide, THMs, benzo(a)pyrene, Ba, Al, Gross beta, $^{226}$Ra, $^{90}$Sr were detected, the levels were not exceeded to the WHO guidelines. In ordes to evalute the safety of drinking water quality, besides of the existed items of standard, new hazardouse pollutants should be considered monitored continenously. For the regulation of hazardous pollutants, it may be introduced from the risk assessment. According to the relevant assessment, the acceptable risk of pollutants estimated could be applied to set the water quality standard or recommendations or quidelines as well as the number of monitoring.

  • PDF

u-방재 서비스 및 모니터링 인프라의 설계에 관한 연구 (A Study on the Design of u-Safety Service and Monitoring Infrastructure)

  • 옥영석;안창원;김민수
    • 한국전자거래학회지
    • /
    • 제14권3호
    • /
    • pp.59-70
    • /
    • 2009
  • 유비쿼터스 컨버전스 산업의 가능성을 확인하기 위한 시험대로서 u-City에 대한 관심이 지속적으로 커져가고 있는 시점에서, u-City의 대표적인 서비스 및 응용 분야로서 u-방재에 대한 연구도 서서히 확대되어가고 있다. u-City의 다른 영역과 마찬가지로 u-방재 서비스의 원활한 제공을 위해서는 기존에 분산되어 운영되고 있는 다양한 u-City 서비스 및 하부 인프라가 종합적으로 연계될 수 있는 방법이 매우 중요하다. 본 연구에서는 분산자원관리 분야에서 널리 활용되고 있는 CIM/WBEM 표준과 대용량 모니터링 데이터의 취득 및 활용에 적절한 모델로 인정되고 있는 GMA를 결합하여 u-방재 서비스 및 모니터링 아키텍처의 설계에 적용하는 방안을 제시하고자 한다. 향후 u-City 서비스 인프라의 표준화 및 확장성에 대한 요구가 더욱 커져갈 것으로 예상된다는 점에서, 본 연구에서 제시하는 통합 인프라 모델은 기존에 구축되어 있는 분산자원들과 지속적으로 추가될 것으로 예상되는 신규 서비스들의 효과적인 통합 모델로써 활용될 수 있을 것이다.

  • PDF

Running safety of metro train over a high-pier bridge subjected to fluctuating crosswind in mountain city

  • Zhang, Yunfei;Li, Jun;Chen, Zhaowei;Xu, Xiangyang
    • Structural Engineering and Mechanics
    • /
    • 제76권2호
    • /
    • pp.207-222
    • /
    • 2020
  • Due to the rugged terrain, metro lines in mountain city across numerous wide rivers and deep valleys, resulting in instability of high-pier bridge and insecurity of metro train subjected to fluctuating crosswind. To ensure the safe operation in metro lines in mountain cities, running safety of the metro train over the high-pier bridge under crosswind is analyzed in this paper. Firstly, the dynamic model of the wind-train-bridge (WTB) system is built, in which the speed-up effect of crosswind is fully considered. On the basis of time domain analysis, the basic characteristics of the WTB system with high-pier are analyzed. Afterwards, the dynamic responses varies with train speed and wind speed are calculated, and the safety zone of metro train over a high-pier bridge subjected to fluctuating crosswind in mountain city is determined. The results indicate that, fluctuating crosswind triggers drastic vibration to the metro train and high-pier bridges, which in turn causes running instability of the train. For this reason, the corresponding safety zone for metro train running on the high-pier is proposed, and the metro traffic on the high-pier bridge should be closed as the mean wind speed of standard height reaches 9 m/s (15.6 m/s for the train).

전력구 내 전자기파에 대한 작업 환경 측정 (The Measurement of Electromagnetic Wave in Power Cable Tunnel of Underground Utility Tunnel)

  • 강대곤;박재학
    • 한국안전학회지
    • /
    • 제34권1호
    • /
    • pp.1-7
    • /
    • 2019
  • Electromagnetic measurements of the power cable tunnel were conducted from August 10 to 20, 2018, in the ${\bigcirc}{\bigcirc}$ city underground utility tunnel. During this period, the average temperature was $31.89^{\circ}C$ and the humidity was 67.56% in power cable tunnel. As a result of the electromagnetic measurement, the highest electric field was 25.3 V/m and the magnetic flux density was $42.6{\mu}T$. The average electric field was 18.56 V/m and the magnetic flux density was $29.32{\mu}T$ in the power cable tunnel. As a result of comparison with the electric equipment technical standard, the electric field in the power cable tunnel was 0.5% of the electric equipment standard and 35.2% of the magnetic flux density. It's similar value that electric field is about robotic vacuum(15.53 V/m), and magnetic flux density is similar value about capsule- type coffee machine ($23.07{\mu}T$). The number of cable lines and the size of the electromagnetic waves were not proportional to each other through comparison of cable lines in the power cable tunnel. It was confirmed that 154 kV, rather than 22.9 kV, could have a greater influence on occupational.