• Title/Summary/Keyword: city gas accident

Search Result 37, Processing Time 0.027 seconds

Revision of related Regulations and Construction Standards for the Use of Information on Underground Facilities Quality Level (지하시설물 품질등급 정보의 활용을 위한 관련 규정 및 건설기준 개정 방안)

  • Park, Joon Kyu;Kim, Tae Hoon;Kim, Won Dae
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.4
    • /
    • pp.343-350
    • /
    • 2022
  • The computerization project for underground facilities in Korea began in earnest after the city gas explosion in Seoul in 1994, and the Daegu subway explosion in 1995. As such a large-scale gas explosion accident caused enormous economic loss including human casualties and potential benefits, the need for computerized for efficient management of underground facilities was greatly emphasized in society. Meantime, computerization of underground facilities has been carried out according to the basic plan for building national geographic information system. In this study, problems were identified based on the current status of construction and management of underground facility information, as well as laws and regulations, and directions for establishing quality standards were presented. In addition, construction work standards such as 「Public Survey Work Regulations」, design standards, standard specifications, and technical specifications, gas technology standards, design standards, and communication works so that underground facility information can be linked and utilized in construction work by examining the linkage of the underground facilities, the targets that can be used for quality level information on underground facilities were derived, and a proposal to revise the construction standards was presented. In the future, if the quality standards are established, it is expected that the accuracy and utilization in the construction field will be increased.

Study on Subsurface Collapse of Road Surface and Cavity Search in Urban Area (도심지 노면하부 지반함몰 및 공동탐사 사례 연구)

  • Chae, Hwi-Young
    • Tunnel and Underground Space
    • /
    • v.27 no.6
    • /
    • pp.387-392
    • /
    • 2017
  • Recently, road cave-ins, also referred to as ground sinking, have become a problem in urban environments. Public utility facilities such as sewage pipelines, communications pipes, gas pipes, power cables, and other types of underground structures are installed below the roads. It was reported that cave-ins are caused by the aging and lack of proper maintenance of underground facilities, as well as by construction problems. A road cave-in is first initiated by the formation of cavities typically induced by the breakage of underground pipelines. The cavities then grow and reach the base of the pavement. The traffic load applied at the surface of the roads causes an abrupt plastic deformation. This type of accident can be considered as a type of disaster. A road cave-in can threaten both human safety and the economy. It may even result in the loss of human life. In the city of Seoul, efforts to prevent damage before cave-ins occur have been prioritized, through a method of discovering and repairing joints through the 3D GPR survey.

A Study on the Change of Traffic Accidents Around the Pedestrian Priority Zone (보행자 우선도로 개선 사업으로 인한 교통사고 변화에 대한 연구)

  • JANG, Jae-Min;LEE, Young-Ihn;KIM, Sukhee;CHOI, Hoi-Kyun
    • Journal of Korean Society of Transportation
    • /
    • v.36 no.2
    • /
    • pp.112-128
    • /
    • 2018
  • We are implementing pedestrian priority zone policy to certain districts to reduce greenhouse gas and to develop eco-friendly city which has more focus on pedestrians' walking environment. This policy has contributed to citizens' satisfaction level with improved public transportation service as well as more spacious streets for walk. Despite highly positive influence of pedestrian priority zone policy to the walking environment, we need to anticipate the impact of this to traffic environment as it may have bad effect to the overall traffic flow around the zone where the policy is implemented. This research has analyzed the change of characteristics of traffic accidents around the eco-traffic area of Hang-Gung dong, Suwon city, to understand impact of the pedestrian priority zone policy to the traffic surroundings, with pre-post analysis methodology. As a result, number of accidents related to pedestrians showed decrease as pedestrian priority zone is designed operated with focus to pedestrians. But accidents related illegal U-turn and violation of the traffic signal showed (significant) increase as there was a restriction of turns and decrease of overall traffic speed. To prevent the accidents above, we need to notice drivers to pay special attention before the pedestrian priority zone event, and information from this research should be given to the drivers through safety signs and mobile application at the place near to the event.

A Study on Practical Analyzing and Improving Disaster Management Organization of Korean Government (재난관리조직의 실태분석과 발전방안)

  • 권오한;남상화;이춘하
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.127-138
    • /
    • 2001
  • I. introduction. A government goal at the present is established to make a welfare nation and to keep people's safe living, but it is criticised that when a large-scale disaster happens, the authority concerned could not deal with it, causing many people injured and material damage. Moreover, in these days, cities have many risk factors. extremely large and intelligent building, industrial facilities and underground equipment have many risk themselves along with scientific progress. The cope with disaster effectively, government must have efficient organization, skillful personnel, tool, facilities and so on. To reduce the damages, what's the most effective government organization\ulcorner II. Government organization for managing disaster In a few decades, a large-sized accidents broke out in korea, for example, collapse of Sampoong department store, break of Sungso bridge, explosion of Daegu city gas, gas explosion accident at Ahyon-dong etc. but government has not any adequate disaster response organization. Especially, after collapse of Sampoong department store broke out, Disaster Management Act is enacted to solve the past problem. According to Disaster management Act, disaster is limited in manmaid disaster. Therefore, in this thesis, disaster management is inspected theoretically, organization of disaster management for pattern of disaster, and role, duty of government organization, emergency relief organization system and actual conditions are analyzed. there are some problems. there are trials and errors. the government has changed the disaster management organization by the disaster management law. the organization consists of central and local government. but both of government do not work together harmoniously. in thesis, I would like to introduce the advanced nations disaster management organization, and study our central, local government organization. III. Conclusion Change and development of the government disaster management organization is the goal of this thesis. we have to increase public service in response and manage disaster. protecting civilian's life from the disaster is very important responsibility of government. there would be better way of government disaster management organization.

  • PDF

The Study on the Countermeasure Plans about Leakage, Explosion and Fire Accidents of Atmospheric Storage Tank (옥외저장탱크 누출, 폭발 및 화재사고 대응방안에 관한 고찰)

  • Lee, Gab-Kyoo
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.48-56
    • /
    • 2016
  • A crude oil leakage from a large atmospheric storage tank occurred on 4 April 2014 at 14:50 in Ulsan City, while storing the crude oil in the tank. Emergency Rescue Control Group was deployed in the scene. The company, Fire Service Headquarters and associated agencies got together in Command Post (CP) for discussing an effective corresponding strategy. Many solution plans were drafted in the debate such as power down, stopping the facilities, checking the density of inflammable gas, suppressing oil evaporation, moving the leaked crude oil to a nearby tank and a processing plant and avoiding marine pollution. All the solutions were carried out in cooperation with several agencies and partners. The oil leakage accident was successfully settled up within the process of responding, The Fire Service Headquarters and the company thought that the most important thing was the suppression of oil evaporation and the elimination of ignition source. With Fire Service Headquarters and several agencies' every effort, an explosion and a fire didn't occurred in the scene. This study suggest the improvement of the operating system in Emergency Rescue Control Group in case of petroleum leakage, explosion and fire accidents of atmospheric storage tank, different from a ordinary disaster. Assuming that petroleum leakage in atmospheric storage tank develop the explosion and fire accidents, the spreading speed of the flame and the burning time was experimented and compared with each other. Furthermore, this study concentrates on the effective field response plan prepared for the afterward explosion and fire accidents from petroleum leak in a storage tank, with the database experimented and analyzed in accordance with the angle of radiation in the foam nozzle and the pressure of pumping in a fire engine.

A Study on the Effect of Mobile CCTV Monitoring on Safety Risk Factors (안전 Risk 요인에 대한 이동형 CCTV 모니터링이 미치는 영향 연구)

  • Young Cheol Song;Tae-Gon Kim;Eunseok Lee;Tae-Hun Kim
    • Industry Promotion Research
    • /
    • v.9 no.1
    • /
    • pp.39-45
    • /
    • 2024
  • Dangerous tasks that occur every day at industrial site manufacturing plants, which have recently been making rapid changes, were classified by type, and the effect of mobile circuit television (CCTV) on safety accidents among daily safety management methods was analyzed. The subject of the study is about 3,000 workers who manage the infrastructure facility sector to supply utilities such as gas, water, and electricity to the display manufacturing process located in Asan City, and the study was conducted based on the daily dangerous work from 2019 to 2022, and during this study period, many construction works such as new investment and expansion of construction and manufacturing processes were occurring at the site. As a result, the rate of safety accidents and exposure to risks are expanding, and most of the safety accidents occurred because the sectors that did not follow the basics and the safety measures on the site were not implemented. In this paper, it was confirmed that there is an accident reduction effect according to the relationship between the dangerous work classified according to the work importance and the mobile CCTV shooting rate. Considering the characteristics of the manufacturing plant site, it can be used to play the role of basic data for preventing safety accidents based on the expansion of the introduction of a new safety management culture in the future.

An Epidemiological Study on the Accidental Mortality in Various Industries in Busan Area (부산지역 산업인구의 사고사에 관한 역학적인 조사연구)

  • Chung, Young-Sun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.10 no.1
    • /
    • pp.166-175
    • /
    • 1977
  • The author have performed an epidemiological study on the accidental deaths at industry from 1970 to 1975, in order to seek for the preventive measures of industrial accident with the under-standing of its cause and characteristics of the accidental deaths. The obtained results were as follows; 1. Total number of deaths for 6 years were 361 (350 males, 11 females). and the mean death rate was 33.8 per 100,000 industrial workers during 6 years. By the highest as 52.9 was in 1974 and the lowest as 13.7 in 1970. By the industry group, the death rate of Electricity, Gas and Water was 149.3, Construction 83.9 and the lowest was Manufacturing as 18.3. 2. Standardized mortality rate of the cases by the age group showed that 20-29 years old group was 43.0, 40-49 years old group 38.1, 30-39 years old group 32.0, and the lowest as 17.9 was under 19 years old group. 3. The cumulative percentage of the cases by years of service showed that under 6 months was 60.4%, under 1 year 72.9%, under 2 years 83.1%. 4. By the month of occurrence, the highest was 15.8% which occurred in August and the lowest was 5.8% in February. The highest as 19.1% was on Friday and the lowest as 11.9% on Monday by the day of a week. 5. By the causes of accident, car accidents was 28.3%, fall accidents 19.1%, accidents by a crash 9.1% in that order. By the location of injury, head was 44.6%, multiple injuries 33.0%, chest 10.5%, and back was the lowest as 1.9%. The distribution of the cases by nature of injury shelved that cerebral contusion and hemorrhage was 39.4%, fracture and dislocation 33.2%, asphyxia 8.0% in that order. 6. The cumulative percentage of the cases by the duration from injury to death showed that the injuried day was 74.2%, within 3 days after injury 88.5%, within 7 days 96.1%. Therefore most of the cases were occurred within 7 days after injury. 7. Byythe daily mean wages, most of the cases as 91.7% were under 2,000 won, and more 4,000 won was 1.6% merely.

  • PDF