• Title/Summary/Keyword: circumferential defect

Search Result 60, Processing Time 0.027 seconds

Inspection of Heat Exchanger Tubing Defects with Ultrasonic Guided Waves (유도초음파를 이용한 열 교환기 튜브 결함 탐상)

  • Shin, Hyeon-Jae;Rose, Joseph L.;Song, Sung-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2000
  • This study shows the defect detection and sizing capability of ultrasonic guided waves in the nondestructive inspection of heat exchanger and steam generator tubing. Phase and group velocity dispersion curves for the longitudinal and flexural modes of a sample Inconel tube were presented for the theoretical analysis. EDM(Electric Discharge Machining) wears in tubing under a tube support plate and circumferential laser notches in tubing were detected by an axisymmetric and a non-axisymmetric transducer set up, respectively. EDM wears were detected with L(0, 2), L(0, 3) and L(0, 4) modes and among them L(0, 4) mode was found to be the most sensitive. It was also found that the flexural modes around L(0, 1) mode could be used for the detection and sizing of laser notches in the tubing.

  • PDF

Microcystic Adnexal Carcinoma of the Lower lip: A Case Report (하구순부에 발생한 미세낭포성 피부부속기 암의 치험례)

  • Lee, Chae Su;Rah, Dong Kyun;Kim, Sang Kyum;Tark, Kwan Chul
    • Archives of Plastic Surgery
    • /
    • v.35 no.3
    • /
    • pp.329-332
    • /
    • 2008
  • Purpose: Microcystic adnexal carcinoma is a rare malignant appendage tumor, first described by Goldstein et al in 1982. Here, we present our experience in treatment of a case on the lower lip. Methods: A 52-year-old female with an asymptomatic nodule on the chin, previously misdiagnosed as trichoadenoma by needle aspiration biopsy, was treated by wide excision combined with multiple circumferential frozen biopsies. Results: Pathological examination revealed typical features of microcystic adnexal carcinoma, such as basaloid and squamous cells forming nests and cord-like patterns, horn cysts, and minimal cytologic atypia. The patient has been followed up for 6 months. No sign of recurrence is noted to date. Conclusion: Differentiation from other benign adnexal neoplasms is important for its appropriate treatment. Differentiation can be difficult histologically because it is difficult to acquire an adequate biopsy due to its invasiveness, and clinically due to its asymptomatic and slow growing features. Complete excision is the key treatment, but it may not always be the best solution considering the huge defect that may result and the low incidence of metastasis & deaths owing to the tumor. We add this case to the approximately 300 cases reported worldwide with a review of literature.

Micromechanical behavior of unidirectional composites under a transverse shear loading (횡방향 전단하중을 받는 단일방향 복합재료의 미시역학적 거동연구)

  • Choi, Heung-Soap;Achenbach, J.D.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.11
    • /
    • pp.1896-1911
    • /
    • 1997
  • Effects of fiber-matrix interphases on the micro-and macro-mechanical behaviors of unidirectionally fiber-reinforced composites subjected to transverse shear loading at remote distance have been studied. The interphases between fibers and matrix have been modeled by the spring-layer which accounts for continuity of tractions, but allows radial and circumferential displacement jumps across the interphase that are linearly related to the normal and tangential tractions. Numerical calculations for basic cells of the composites have been carried out using the boundary element method. For an undamaged composite the micro-level stresses at the matrix side of the interphase and effective shear stiffness have been computed as functions of fiber volume ratio $V_f$ and interphase stiffness k. Results are presented for various interphase stiffnesses from the perfect bonding to the case of total debonding. For a square array composite the results show that for a high interphase stiffness k>10, an increase of $V_f$ increases the effective transverse shear modulus G over bar of the composite. For a relatively low interphase stiffness k<1, it is shwon that an increase of $V_f$ slightly decreases the effective transverse shear modulus. For the perfect bonding case, G over bar for a hexagonal array composite is slightly larger than that for a square array composite. Also for a damaged composite partially debonded at the interphase, local stress fields and effective shear modulus are calculated and a decrease in G over bar has been observed.

The effects of the surface defects on the hydroformability of extruded aluminum tubes (알루미늄 압출 관재의 표면 결함이 하이드로포밍 성형에 미치는 영향도에 관한 연구)

  • Kim D. H.;Kim B. J.;Park K. S.;Moon Y. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.10a
    • /
    • pp.247-250
    • /
    • 2005
  • The need for improved fuel efficiency, weight reduction has motivated the automotive industry to focus on aluminum alloys as a replacement for steel-based alloy. To cope with the needs for high structural rigidity with low weight, it is forecasted that substantial amount of cast components will be replaced by tubular parts which are mainly manufactured by the extruded aluminum tubes. The extrusion process is utilized to produce tubes and hollow sections. Because there is no weld seam, the circumferential mechanical properties may be uniform and advantageous for hydroforming. However the possibility of the occurrence of a surface defect is very high, especially due to the temperature increase from forming at high pressure when it comes out of the bearing and the roughness of the bearing, which cause the surface defects such as the dies line and pick-up. And when forming a extruded aluminum tube, the free surface of the tube becomes rough with increasing plastic strain. This is well known as orange peel phenomena and has a great effect not only on the surface quality of a product but also on the forming limit. In an attempt to increase the forming limit of the tubular specimen, in the present paper, surface asperities generated during the hydroforming process are polished to eliminate the weak positions of the tube which lead to a localized necking. It is shown that the forming limit of the tube can be considerably improved by simple method of polishing the surface roughness during hydroforming. And also the extent of the crack propagation caused by dies lines generated during the extrusion process is evaluated according to the deformed shape of the tube.

  • PDF

A Study on Failure Modes of Type4 Composite Pressure Cylinders according to Shapes of Domes (Type4 복합재 용기의 돔 형상에 따른 파열형태에 관한 연구)

  • Cho, Sungmin;Kim, Kwang Seok;Cho, Min-sik;Lee, Sun-kyu;Lee, Seung-kuk;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.5
    • /
    • pp.13-18
    • /
    • 2017
  • In this work the augmented safety of Type 4 composite vessel in accordance with uniform-stress design has been demonstrated through a series of burst tests and structural analyses. For this end, three sample vessels were used: (1) designed as guided by the isotensoid dome theory (called iso-dome cylinder); (2) with dome longer compared to uniform-stress design (called prolate cylinder); and (3) with dome wider than uniform-stress design (called oblate cylinder). Structural analyses have been performed using ABAQUS finite element code based on the periodic symmetry to circumferential direction. As a result, the maximum stresses are induced around the bodies of all three cylinders. However, the analyses, with the assumption of possible defect demonstrate that the maximum stresses are induced around the dome knuckles for the prolate and the oblate cylinders. The results of the burst tests for the three cylinders show that the burst initiates from the cylinder body of the iso-dome cylinder and from the dome knuckles of the prolate and the oblate cylinders. Finally, it is recommended that, to comply with DOT CFFC 2007, the dome shape should be designed and fabricated as guided by the isotensoid dome theory.

Study for Development of Nondestructive Inspection Device in Natural Gas Pipeline Using MFL Technology (MFL을 이용한 천연가스 배관용 비파괴 검사장비 개발에 관한 연구)

  • Cho S.H.;Kim D.K.;Park D.J.;Park S.S.;Yoo H.R.;Koo S.J.;Rho Y.W.;Kho Y.T.
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.1 s.17
    • /
    • pp.10-16
    • /
    • 2002
  • This paper introduces developed prototype intelligent pig which detects corrosion on pipeline by using Magnetic Flux Leakage technology. The 8 inch developed MFL(Magnetic Flux Leakage) pig is composed of 5 yokes which magnetize pipeline wall and 45 Hall sensors which detect MFL signal. The designed MFL modules are analyzed by using magnetic circuit method in order to confirm whether pipeline wall is fully saturated. A variety of artificial defects are manufactured on 8 inch diameter steel pipeline in order to acquire MFL signals. So leakage flux of the axial, radial and circumferential component was acquired as defects. The results of this paper show that design technique for 8 inch MFL pig can be applied to large diameter MFL pig and 0.5mm defect depth can be detected.

  • PDF

Surgical refinement of the purse-string suture for skin and soft tissue defects of the head and neck

  • Park, Hyochun;Lee, Yunjae;Yeo, Hyeonjung;Park, Hannara
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.4
    • /
    • pp.183-192
    • /
    • 2021
  • Background: The purse-string suture (PSS) is a simple and rapid wound closure method that results in minimal scarring. It has been used to treat circular or oval skin defects caused by tumor excision or trauma. However, due to obscurity, it is not widely used, especially for the head and neck. This study aimed to modify the PSS to obtain predictable and acceptable results. Methods: A total of 45 sites in 39 patients with various types of skin and soft tissue defects in the head and neck were treated with PSS. We used PDS II (2-0 to 5-0), which is an absorbable suture. Minimal dissection of the subcutaneous layer was performed. The suture knot was hidden by placing it in the dissection layer. Depending on the characteristics of the skin and soft tissue defects, additional surgical interventions such as side-to-side advancement sutures, double PSS, or split-thickness skin graft were applied. Results: All wounds healed completely without any serious complications. Large defects up to 45 mm in diameter were successfully reconstructed using only PSS. Postoperative radiating folds were almost flattened after approximately 1-2 months. Conclusion: PSS is simple, rapid, and relatively free from surgical design. Owing to the circumferential advancement of the surrounding tissue, PSS always results in a smaller scar than the initial lesion and less distortion of the body structures around the wound in the completely healed defect. If the operator can predict the process of healing and immediate radiating folds, PSS could be a favorable option for round skin defects in the head and neck.

Evaluation of clinical status of removable partial dentures (가철성 국소의치의 임상적 상태에 대한 평가)

  • Yang, Dong-Seok;Cho, Uk;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.320-327
    • /
    • 2009
  • Statement of Problem: Although many efforts have been continually made to estimate long term prognosis of removable partial dentures, the complication of removable partial dentures was still found because of inaccurate fabrication procedure and improper maintenance care. Purpose: The purpose of this study was to evaluate the clinical status of removable partial dentures. Material and methods: A total of 112 individuals with 153 removable partial dentures (35 - 87 years, 64 women and 48 men) were examined by intra-oral examination, diagnostic cast and radiographic examination. Results and conclusion: The results of this study were as follows: 1. Length of service of removable partial dentures was $5.3{\pm}4.3$ years (mean), 4.0 years (median). 2. A total of 45 removable partial dentures were considered failures. The loss of 18 abutments of 369 was founded. 3. Type of arch, Kennedy classification and type of opposite dentition were found to have no influence on longevity and success rate of removable partial dentures (P > .05). 4. Most common major connector was the palatal plate in maxilla and the number of lingual bar and linguoplate designed in mandible were similar. 5. The circumferential type retainer was the most commonly used retainer. 6. Sixty-three percent of the class I and II removable partial dentures incorporated indirect retention into the design. 7. Approximately 81% of the removable partial dentures had at least one defect. Excessive wear of posterior teeth (27.9%), lack of integrity (23.2%), lack of stability (22.6%) were frequent defects of removable partial dentures.

A Quantitative Method for the Assessment of Myocardial Function using the Polar Analysis of Tc-99m-MIBI Myocardial SPECT (Tc-99m-MIBI 심근 SPECT 극성지도 분석에 의한 심근 기능의 정량적 평가)

  • Kwark, Cheol-Eun;Lee, Dong-Soo;Yeo, Jung-Suk;Lee, Kyung-Han;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.172-176
    • /
    • 1994
  • As the Tc-99m-MIBI myocardial SPECT demonstrated wide application in the diagnosis of myocardial function, the quantitative and severity-dependent information is currently re quired. In this study, we proposed a computerized method for scoring the fixed defects in terms of extent-weighted severity and for identifying the reversibility in ischemic regions. At the first stage of this method, the transverse slices were reconstructed with 0.4 Nyquist freq. and order 5 Butterworth filter. From the oblique/sagittal slices, maximal count per pixel circumferential profiles were extracted for each sector, and then stress/redist. polar maps were normalized and plotted. For reversibility, the stress polar map was subtracted from the de-layed image and positive-valued pixels were categorized into three grades. The extent-weight-ed severity scores were calculated using the assigned grades and their number of pixels. This procedure was done automatically and the reversibility and severity scores were produced for each of the coronary territories (LAD, RCA, LCX) or any combination of these. Clinical ap-plication has shown that the changes In reversibility scores after PTCA were correlated linearly with the pre PTCA scores(r>0.8) in postinfarct cases as well as in angina, and severity scores of persistent defects in stress/rest SPECT study matched to the regional ejection fraction and visual analysis of regional wall motion of gated blood pool scan(r>0.6). We conclude that the computerized severity scoring method for the analysis of myocardial SPECT could be useful in the assessment of the myocardial ischemia and fixed defect.

  • PDF

Outcomes of the Warden Procedure for Anomalous Pulmonary Venous Return to the Superior Vena Cava: A 17-Year Experience

  • Lim, Su Chan;Kwak, Jae Gun;Cho, Sungkyu;Min, Jooncheol;Lee, Sangjun;Kwon, Hye Won;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.55 no.3
    • /
    • pp.206-213
    • /
    • 2022
  • Background: Surgical repair of partial anomalous pulmonary venous return (PAPVR) to the superior vena cava (SVC) using the Warden procedure has favorable outcomes. However, there remain some concerns after the Warden procedure, such as sinoatrial nodal dysfunction and systemic or pulmonary venous stenosis. We investigated the outcomes of the Warden procedure for repair of PAPVR to the SVC. Methods: This retrospective study included 22 consecutive patients who underwent the Warden procedure for PAPVR between 2002 and 2018. The median age and body weight at operation were 27.5 months (interquartile range [IQR], 5.0-56.8 months) and 13.2 kg (IQR, 6.5-16.0 kg), respectively. The median follow-up duration was 6.2 years (IQR, 3.5-11.6 years). Results: There were no cases of early or late mortality. No patients had postoperative heart rhythm problems, except 1 patient who showed transient sinoatrial nodal dysfunction in the immediate postoperative period. Procedure-related complications requiring reintervention occurred in 5 patients, including 3 of 4 SVC stenosis cases and 2 pulmonary venous stenosis cases during follow-up. The rate of freedom from reintervention related to the Warden procedure was 75.9% at 10 years. Conclusion: In cases requiring extension or creation of an atrial septal defect to achieve a sufficient venous pathway, or interposition of an entire circumferential conduit between the SVC and right atrium due to the shortness of the SVC in the Warden procedure, stenotic complications of the venous pathway occurred. Careful observation of changes in the pressure gradient or anatomical stenosis is required in such patients.