• 제목/요약/키워드: circumferential defect

검색결과 61건 처리시간 0.024초

입구 불균일 유동에 의한 원심압축기 스톨에 관한 실험적 연구 (The Effect of Inlet Distortion on a Centrifugal Compressor)

  • 박재형;강신형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.476-481
    • /
    • 2003
  • In this paper, the effect of circumferential inlet distortion on performance and stall has been experimentally investigated in a high-speed centrifugal compressor, comparing distorted cases with undistorted one. The performance of compressor was slightly deteriorated by defect of inlet static pressure which is caused by the circumferential inlet distortion. As stall was fully developed the inlet distortion did not affect the number of stall cell and the propagation velocity. It also did not affect stall inception at 40,000 and 50,000 rpm. However stall occurred at the lower flow rate for distorted flow at 60,000 rpm. For 50,000 rpm a unexpected phenomenon occurred : stall occurred first and then it disappeared.

  • PDF

Soft Tissue Reconstruction of Complete Circumferential Defects of the Upper Extremity

  • Ng, Zhi Yang;Tan, Shaun Shi Yan;Lellouch, Alexandre Gaston;Cetrulo, Curtis Lisante Jr;Chim, Harvey Wei Ming
    • Archives of Plastic Surgery
    • /
    • 제44권2호
    • /
    • pp.117-123
    • /
    • 2017
  • Background Upper extremity soft tissue defects with complete circumferential involvement are not common. Coupled with the unique anatomy of the upper extremity, the underlying etiology of such circumferential soft tissue defects represent additional reconstructive challenges that require treatment to be tailored to both the patient and the wound. The aim of this study is to review the various options for soft tissue reconstruction of complete circumferential defects in the upper extremity. Methods A literature review of PubMed and MEDLINE up to December 2016 was performed. The current study focuses on forearm and arm defects from the level at or proximal to the wrist and were assessed based on Tajima's classification (J Trauma 1974). Data reviewed for analysis included patient demographics, causality, defect size, reconstructive technique(s) employed, and postoperative follow-up and functional outcomes (when available). Results In accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, 14 unique articles were identified for a total of 50 patients (mean=28.1 years). Underlying etiologies varied from extensive thermal or electrical burns to high impact trauma leading to degloving or avulsion, crush injuries, or even occur iatrogenically after tumor extirpation or extensive debridement. Treatment options ranged from the application of negative pressure wound dressings to the opposite end of the spectrum in hand transplantation. Conclusions With the evolution of reconstructive techniques over time, the extent of functional and aesthetic rehabilitation of these complex upper extremity injuries has also improved. The proposed management algorithm comprehensively addresses the inherent challenges associated with these complex cases.

원주 유도초음파의 분산 특성 해석 및 가압중수로 피더관 균열 탐지에의 응용 (Analysis of Dispersion Characteristics of Circumferential Guided Waves and Application to feeder Cracking in Pressurized Heavy Water Reactor)

  • 정용무;김상수;이동훈;정현규
    • 비파괴검사학회지
    • /
    • 제24권4호
    • /
    • pp.307-314
    • /
    • 2004
  • 배관의 축방향 균열 검사를 위하여 원주 방향으로 진행하는 유도초음파 모드를 적용하였다. 배관의 곡률을 변수로 원주 유도초음파의 분산선도를 계산하였으며 이를 배관 검사에 적용하기 위하여 중수로 피더관의 곡관부 축방향 균열을 탐지에 적용하였다. 상대적으로 낮은 주파수에서는 Lamb 파 특성을 따르나 주파수가 증가함에 따라 평판의 경우, 즉 곡률이 무한대인 경우 첫 번째 $A_0$ 모드와 두 번째 $S_0$ 모드가 합쳐져서 Rayleigh 모드 형태로 변화한다. 한편 곡률을 가진 배관의 경우는 주파수가 증가하더라도 첫 번째 모드와 두 번째 모드가 합쳐지지 않았다. 이러한 해석을 기초로 하여 배관의 일종인 중수로 피더관 곡관부 축방향 결함을 탐지하기 위하여 사각 탐촉자를 사용하여 Rocking 원주 유도초음파 기법을 적용하였다. 원주 방향으로 유도파를 진행시키면서 인공 결함으로부터의 수집된 신호를 분석하여 진동 모드를 확인하였으며 두께 대비 10% 깊이의 notch도 검출할 수 있음을 확인할 수 있었다.

적외선열화상 카메라를 이용한 원전 소구경 감육배관의 결함 검출 (Application Defects Detection in the Small-Bore Pipe Using Infrared Thermography Technique)

  • 윤경원;김동률;정현철;홍동표;김경석
    • 비파괴검사학회지
    • /
    • 제33권1호
    • /
    • pp.34-39
    • /
    • 2013
  • 선행 연구에서 적외선열화상기법을 이용하여 원전 배관의 감육 결함을 측정하기 위하여, 4 inch 배관에 인공결함을 가공하여 이에 대한 결함 검출을 도출하였다. 본 논문에서는 선행연구에서 도출된 조건을 이용하여 원전 소구경 배관의 결함 검출 조건에 관한 연구를 수행하였다. 결함의 가공은 감육 길이, 원주방향 각도, 감육 깊이를 변화시켜서 결함 조건을 가공하였다. 사용된 장비는 IR camera와 1 kW용량의 halogen lamp 2개를 사용하였으며, halogen lamp와 대상 배관과의 거리를 1 m, 1.5 m, 2 m 순으로 변화시켜 실험을 수행하였다. 실험 결과의 분석을 위하여 온도분포데이터를 확보하고, 이를 분석하여 결함 길이를 측정하였다. 4 inch 배관의 인공결함은 2 m에서 측정 결과의 신뢰도가 높았으나, 소구경 배관은 1.5 m에서 결함이 명확하게 검출되었다.

전기자극이 성견 골결손부에 매식된 임플란트 주위조직의 치유에 미치는 영향 (Effects of electrical stimulation on healing of endo-osseous titanium implants in circumferential defect)

  • 심재창;김영준;정현주;김옥수
    • Journal of Periodontal and Implant Science
    • /
    • 제34권1호
    • /
    • pp.177-193
    • /
    • 2004
  • Several experimental studies showed that the application of small amounts of electric current to bone stimulated osteogenesis at the site of the cathode and suggested that electrical currents promote osseointegration around dental implants. The purpose of this study was to determine the effect of direct microcurrent to endosseous titanium implants placed in bone defects. The right and left 2nd, 3rd and 4th mandibular premolars in ten mongrel dogs (15Kg of weight) were extracted. One monthe later, Ti-machined screw type implants(3.8 mm diameter x 8.5 mm length, $AVANA^{(R)}$, Ostem) were placed in surgically created circumferential defect area(width 5mm, depth 4mm). The implants were divided into three groups according to the treatment modalities: Control group- implants without electrical stimulation; Experimental group I- implants with allogenic demineralized freeze dried bone grafting; and Experimental group II-implants allogenic demineralized freeze dried bone grafting and electric stimulation. The animals were sacrificed in the 4th and 8th week after implant placement and un-decalcified specimens were prepared for histological and histometrical evaluation of bone-implant contact ratio (BIC) and bone formation area ratio (BFA) in defect area. Some specimens at 8 weeks after implantation were used for removal torque testing. Histologically, there was connective tissue infiltration in the coronal part of defect area in control and the experimental group I, whereas direct bone contact was found in the experimental group II without connective tissue invasion. Average BIC ratios at 4 weeks of healing were 60.1% in the experimental group II, 47.4% in the experimental group I and 42.7% in the control. Average BIC ratios at 8 weeks after implantation were 67.6% in the experimental group II, 55.9% in the experimental group I and 54.6% in the control. The average BFA ratio was 84.0% in the experimental group II, 71.8% in the experimental group I and 58.8% in the control at 4 weeks, and the BFA ratios were 89.6% in the experimental group II, 81.4% in the experimental group I and 70.5% in the control at 8 weeks after implantation. The experimental group II showed also significantly greater BIC and BFA ratios compared to the control and the experimental group I (p<0.05). The removal torque values at 8 weeks after implantation were 56 Ncm in the experimental group II, 49 Ncm in the experimental group I and 43 Ncm in the control. There was a statistically significant difference among 3 groups (p<0.05). These results suggest that electrical stimulation improve and accelerate bone healing around endosseous titanium implants in bone defect.

Buckling of cylindrical shells under external pressure proposition of a new shape of self-stiffened shell

  • Araar, M.;Jullien, J.F.
    • Structural Engineering and Mechanics
    • /
    • 제4권4호
    • /
    • pp.451-460
    • /
    • 1996
  • We propose a new shape of cylindrical shell formed by multiples vaults which gives a self-stiffening against buckling. By an experimental and numerical study of cylindrical shells with a repeated defect, on the circumferential direction made only of outside oriented wave-defects, we show that multiple vault cylindrical shells can have a good behaviour in buckling. An optimal behaviour is obtained by optimization of the vaults number, with conduces to a special multiple vault cylindrical shell named "ASTER shell".

결함을 가진 증기발생기 U-튜브의 진동특성 (Vibration Characteristics of Steam Generator U-tubes with Defect)

  • 조종철;정명조;김웅식;김효정;김태형
    • 한국소음진동공학회논문집
    • /
    • 제13권5호
    • /
    • pp.400-408
    • /
    • 2003
  • This paper investigates the vibration characteristics of steam generator (SG) U-tubes with defect. The operating SG shell-side flow field conditions for determining the fluidelastic instability parameters such as added mass are obtained from three-dimensional SG flow calculation. Modal analyses are performed for the U-tubes either with axial or circumferential flaw with different sizes. Special emphases are on the effects of flaw orientation and size on the modal and instability characteristics of tubes, which are expressed in terms of the natural frequency, corresponding mode shape and stability ratio. Also, addressed is the effect of the internal pressure on the vibration characteristics of the tube.

실배관 파열실험을 통한 국부감육 곡관 손상압력 평가 (Failure Pressure Evaluation of Local Wall-Thinned Elbows by Real-scale Burst Tests)

  • 김진원;박치용;이성호
    • 대한기계학회논문집A
    • /
    • 제31권10호
    • /
    • pp.1017-1024
    • /
    • 2007
  • This study performed a series of burst tests at ambient temperature using real-scale elbow specimen containing a local wall-thinning defect at it's intrados or extrados and evaluated failure pressure of locally wall-thinned elbows. In the experiment, a 90-degree 100A, Sch. 80 standard elbow was employed, and various wall-thinning geometries, such as length, depth, and circumferential angle, were considered. From the results of experiment, the dependences of failure pressure of wall-thinned elbows on the defect geometries and locations were investigated. In addition, the reliability of existing models was examined by comparing the tests data with the results predicted from existing failure pressure evaluation models for locally wall-thinned elbow.

유한요소법을 이용한 지상 파이프 반사계수 규명 (Identification of Reflection Coefficients for Overground Pipes Using Finite Element Method)

  • 김영환;박경조;강우석
    • 동력기계공학회지
    • /
    • 제15권3호
    • /
    • pp.18-24
    • /
    • 2011
  • In this study, the reflection of the L(0,2), axially symmetric guided elastic wave from defects in pipes above ground is examined using finite element method. Phase and group velocity dispersion curves for the pipe were presented for the selection of the excitation mode. Some simple signal processing was applied to determine the amplitude of each of the reflected waves and to calculate the reflection coefficient. The results show the reflection coefficient of this mode is very close to a linear function of the circumferential extent of the defect. The motivation for the work was the development of a technique for inspecting chemical plant pipelines, but the study addresses the nature of the reflection function and its general applicability.

Reconstructive Trends in Post-Ablation Patients with Esophagus and Hypopharynx Defect

  • Ki, Sae Hwi;Choi, Jong Hwan;Sim, Seung Hyun
    • 대한두개안면성형외과학회지
    • /
    • 제16권3호
    • /
    • pp.105-113
    • /
    • 2015
  • The main challenge in pharyngoesophageal reconstruction is the restoration of swallow and speech functions. The aim of this paper is to review the reconstructive options and associated complications for patients with head and neck cancer. A literature review was performed for pharynoesophagus reconstruction after ablative surgery of head and neck cancer for studies published between January 1980 to July 2015 and listed in the PubMed database. Search queries were made using a combination of 'esophagus' and 'free flap', 'microsurgical', or 'free tissue transfer'. The search query resulted in 123 studies, of which 33 studies were full text publications that met inclusion criteria. Further review into the reference of these 33 studies resulted in 15 additional studies to be included. The pharyngoesophagus reconstruction should be individualized for each patient and clinical context. Fasciocutaneous free flap and pedicled flap are effective for partial phayngoesophageal defect. Fasciocutaneous free flap and jejunal free flap are effective for circumferential defect. Pedicled flaps remain a safe option in the context of high surgical risk patients, presence of fistula. Among free flaps, anterolateral thigh free flap and jejunal free flap were associated with superior outcomes, when compared with radial forearm free flap. Speech function is reported to be better for the fasciocutaneous free flap than for the jejunal free flap.