• Title/Summary/Keyword: circulating fluidized bed

Search Result 188, Processing Time 0.026 seconds

Analysis for Particle Motion of Vertical Rayleigh flow (수직 Rayleigh 유동내의 입자 거동 해석)

  • Ko, Seok-Bo;Jun, Yong-Du;Lee, Kum-Bae
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.755-760
    • /
    • 2006
  • The exhaust gas with solid particle goes through the riser in both particle circulating type and circulating fluidized bed type heat exchanger to recover the heat. During heat transfer, gas velocity in vertical riser decreases as viscosity of exhaust gas decreases. In this case, when the particle size is fixed, sometimes the exhaust gas happens to have lower velocity which prohibit them to go out of the riser. In this paper the particle motion in vertical Rayleigh flow was studied. The behavior of heat transfer was investigated by means of velocity and temperature distribution. The result from numerical analysis was validated by the experimental results. Fortran code was used to analyze the particle motion in vertical Rayleigh flow.

  • PDF

Strength Properties of Blast Furnace Slag-based Hardened Materials with Addition Rate of Alkali Stimulant NaOH (알칼리 자극제 NaOH의 첨가율에 따른 고로슬래그 기반 경화체의 강도 특성)

  • Kyung, Seok-Hyun;Choi, Byung-Cheol;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.135-136
    • /
    • 2019
  • Recently, as the interest in environmental issues increases, the construction industry needs to recycle blast furnace slag, circulating fluidized bed Combustion fly ash, etc. to solve industrial by-products, and to develop artificial stone. In this study, the strength characteristics based on blast furnace slag according to the addition rate of alkali stimulant NaOH are investigated. The experimental results showed that the flexural and compressive strengths increased with the addition of alkali stimulants. Based on these results, it will be presented as a basic research data for the manufacture of artificial stone and will be tested later.

  • PDF

Characteristics of Fluid Flow and Heat Transfer in a Fluidized Bed Heat Exchanger (순환유동층 열교환기내 유동과 열전달 특성)

  • 안수환;이병창;김원철;이윤표
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.4
    • /
    • pp.315-323
    • /
    • 2002
  • The commercial viability of heat exchanger is mainly dependent on their long-term fouling characteristics because the fouling increases the pressure loss and degrades the thermal performance of a heat exchanger. An experimental study was performed to investigate the characteristics of fluid flow and heat transfer in a fluidized bed heat exchanger with circulating various solid particles. The present work showed that the drag force coefficients of particles in the internal flow were higher than those in the external flow, in addition, the solid particle periodically hitting the tube wall broke the thermal boundary layer, and increased the rate of heat transfer. Particularly when the flow velocity was low, the effect was more pronounced.

Fouling Reduction Characteristics of a Fluidized Bed Heat Exchanger for Flue Gas Heat Recovery (연도가스 열회수용 순환유동층 열교환기의 오염저감특성)

  • 이금배;전용두
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.770-777
    • /
    • 2004
  • Fouling and cleaning tests are performed for a uniquely designed 7,000 ㎉/hr fluidized bed heat exchanger for exhaust gas heat recovery. Fuel rich condition is maintained in the combustor for a limited time period to generate soot that is to be deposited on the heat transfer surfaces (fouling) and 600 Um glass beads are circulated inside the heat exchanger system for cleaning and enhancing the heat transfer performance. According to the present experimental study, performance degradation mode could be monitored and the effect of particle circulation on the heat transfer improvement could be identified. Through the present study, it is demonstrated that circulating particles contribute not only to the fouling reduction in gas side, but also to the heat transfer enhancement of the unit, while other possible aging factors including water side corrosion seemed to contribute to the accumulated performance deterioration.

A Experiment of Combustion Behavior of Biomass Fuels (바이오매스 연료의 연소 특성 실험)

  • KIM, HAKDEOK;KIM, YOUNGDAE;SONG, JUHUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.5
    • /
    • pp.503-511
    • /
    • 2018
  • There have been many studies of combustion in the circulating fluidized bed. However, little study is available for combustion of wood pellet together fed with wood chip. The mixed ratio of two fuels is an useful information when thermal power company would receive the Renewable Energy Portfolio Standard (RPS) from government. In this study, the combustion behavior and kinetics of such biomass fuels are evaluated using fluidized bed reactor and thermogravimetric analyzers. The mixing ratio of wood chip relative to wood pellet was varied at different temperatures. The results show that a combustion reactivity changed significantly at the wood chip mixing ratio of 40%, particularly at low temperature condition.

Fluid Flow and Heat Transfer in the Fluidized Bed Heat Exchanger (순환 유동층 열교환기내 유체유동과 열전달)

  • 김원철;배성택;이병창;안수환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.39-45
    • /
    • 2004
  • The commercial viability of heat exchanger is mainly dependent on their long-term fouling characteristics because the fouling increases the pressure loss and degrades the thermal Performance of a heat exchanger. An experimental study was performed to investigate the characteristics of fluid flow and heat transfer in a fluidized bed heat exchanger with circulating various solid particles. The Present work showed that the flow velocity range for Possible collision between the tube wall and the particles was higher with heavier density solid particles. in audition. the solid particle periodically hitting the tube wall broke the thermal boundary laver. and increased the rate of heat transfer.

Comparison of Solid Circulation Characteristics with Change of Lower Loop Seal Geometry in a Circulating Fluidized Bed (순환유동층에서 하부 루프실 형태 변화에 따른 고체순환 특성 비교)

  • Lee, Dong-Ho;Jo, Sung-Ho;Jin, Gyoung-Tae;Yi, Chang-Keun;Ryu, Ho-Jung;Park, Seung Bin
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.522-529
    • /
    • 2014
  • Circulating fluidized bed system consists of SEWGS reactor - lower loop seal - regeneration reactor - riser - cyclone - upper loop seal has been used for solid circulation between the SEWGS reactor and the regeneration reactor in a SEWGS system for pre-combustion $CO_2$ capture. A vertical type lower loop seal has been used in current system but this lower loop seal requires high gas flow rate through the lower loop seal for fluidization and smooth solid circulation, and consequently, causes slugging behavior sometimes. To overcome these disadvantages, inclined type lower loop seal was proposed by this study. Solid circulation characteristics with change of lower loop seal geometry were measured and compared in a bubbling - bubbling - riser type circulating fluidized bed using $CO_2$ absorbent (P-78) as bed material at ambient temperature and pressure. We could conclude that the inclined lower loop seal is better than the vertical type lower loop seal from the viewpoints of minimum flow rate requirement for stable solid circulation and solid height change during solid circulation.

Conceptual Design of 50 kW thermal Chemical-Looping Combustor and Analysis of Variables (열량기준 50kW급 매체순환식 가스연소기의 개념설계 및 변수해석)

  • 류호정;진경태
    • Journal of Energy Engineering
    • /
    • v.12 no.4
    • /
    • pp.289-301
    • /
    • 2003
  • To develop a chemical-looping combustion technology, conceptual design of 50 kW thermal chemical-looping combustor, which is composed of two interconnected pressurized circulating fluidized beds, was performed by means of mass and energy balance calculations. A riser type fast fluidized bed was selected as an oxidizer and a bubbling fluidized bed was selected as a reducer by mass balance for the chemical-looping combustor. Calculated values of bed mass, solid circulation flux, and reactor dimension by mass and energy balance calculations were suitable for construction and operation of chemical-looping combustor. It is concluded from the comparison of the design results and operating values of commercial circulating fluidized bed that the process outline is realistic. Moreover, the previous results support that oxygen carrier particle, NiO/bentonite, fulfills the conversion rates needed for the proposed design. The effects of system capacity, metal oxide content in a oxygen carrier particle, amount of steam input, gas velocity, and solid depth on design values were investigated and the changes in the system performance can be estimated by proposed design tool.