• Title/Summary/Keyword: circular distribution

Search Result 649, Processing Time 0.034 seconds

A Three-dimensional Photoelastic Analysis of Stress Distributions Around Osseointegrated Implants and Abutment Teeth According to Bridge Connecting Type (골유착성(骨癒着性) 임플란트와 치아간(齒牙間)의 보철물(補綴物) 연결(連結) 형태(形態)에 따른 주위(周圍) 골조직(骨組織)의 응력분산(應力分散)에 관한 3차원적(次元的) 광탄성(光彈成) 분석(分析))

  • Lee, Moo-Geon;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.120-147
    • /
    • 1994
  • This study was performed for the purpose of evaluating the stress distribution around threaded type implants, cylindrical type implants and teeth connected with rigid or non-rigid connector. The stress distribution around the surrounding bone was analyzed by three-dimensional photoelastic method. Twelve mandibular photoelastic epoxy resin models and a circular polariscope were used to record the isochromatic fringes. After the stress distribution around the implant and tooth was observed, the results were as follows ; 1. In threaded type implants, stress concentrated patterns were observed at the neck either vertical or 25 degree lateral force. 2. The stress concentrated patterns were observed at the tooth apical portion and neck portions of the implant and tooth when a threaded implant was connected with the tooth by either a rigid or non-rigid connector. More force was generated at the tooth neck portion by a rigid connector and more force at the implant neck portion by a non-rigid connector. 3. The stress concentrated patterns were observed at the apical portion of the implant and tooth when a cylindrical type ,implant was connected with the tooth either by a rigid or non-rigid connector. More force was generated at the tooth apical portion by a rigid connector and more force at the neck portion of the tooth and implant by a non-rigid connector. 4. The stress around the tooth was more equally distributed in a threaded type implant than in a cylindrical implant when the tooth was connected with either a rigid or non-rigid connector. 5. The stress around a threaded type implant was progressively more equally distributed in the following order : 1) when used a single implant, 2) a non-rigid connection with the implant and tooth, 3) a rigid connection with the implant and tooth, 4) a rigid connection with two implant fixtures.

  • PDF

A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy (수술중 전자선치료에 있어서 선량분포에 관한 연구)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.1-12
    • /
    • 1992
  • For intraoperative radiation therapy using electron beams, a cone system to deliver a large dose to the tumor during surgical operation and to save the surrounding normal tissue should be developed and dosimetry for the cone system is necessary to find proper X-ray collimator setting as well as to get useful data for clinical use. We developed a docking type of a cone system consisting of two parts made of aluminum: holder and cone. The cones which range from 4cm to 9cm with 1cm step at 100cm SSD of photon beam are 28cm long circular tubular cylinders. The system has two 26cm long holders: one for the cones larger than or equal to 7cm diamter and another for the smaller ones than 7cm. On the side of the holder is an aperture for insertion of a lamp and mirror to observe treatment field. Depth dose curve. dose profile and output factor at dept of dose maximum. and dose distribution in water for each cone size were measured with a p-type silicone detector controlled by a linear scanner for several extra opening of X-ray collimators. For a combination of electron energy and cone size, the opening of the X-ray collimator was caused to the surface dose, depths of dose maximum and 80%, dose profile and output factor. The variation of the output factor was the most remarkable. The output factors of 9MeV electron, as an example, range from 0.637 to 1.549. The opening of X-ray collimators would cause the quantity of scattered electrons coming to the IORT cone system. which in turn would change the dose distribution as well as the output factor. Dosimetry for an IORT cone system is inevitable to minimize uncertainty in the clinical use.

  • PDF

Beam Shaping by Independent Jaw Closure in Steveotactic Radiotherapy (정위방사선치료 시 독립턱 부분폐쇄를 이용하는 선량분포개선 방법)

  • Ahn Yong Chan;Cho Byung Chul;Choi Dong Rock;Kim Dae Yong;Huh Seung Jae;Oh Do Hoon;Bae Hoonsik;Yeo In Hwan;Ko Young Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.150-156
    • /
    • 2000
  • Purpose : Stereotactic radiation therapy (SRT) can deliver highly focused radiation to a small and spherical target lesion with very high degree of mechanical accuracy. For non-spherical and large lesions, however, inclusion of the neighboring normal structures within the high dose radiation volume is inevitable in SRT This is to report the beam shaping using the partial closure of the independent jaw in SRT and the verification of dose calculation and the dose display using a home-made soft ware. Materials and Methods : Authors adopted the idea to partially close one or more independent collimator jaw(5) in addition to the circular collimator cones to shield the neighboring normal structures while keeping the target lesion within the radiation beam field at all angles along the arc trajectory. The output factors (OF's) and the tissue-maximum ratios (TMR's) were measured using the micro ion chamber in the water phantom dosimetry system, and were compared with the theoretical calculations. A film dosimetry procedure was peformed to obtain the depth dose profiles at 5 cm, and they were also compared with the theoretical calculations, where the radiation dose would depend on the actual area of irradiation. Authors incorporated this algorithm into the home-made SRT software for the isodose calculation and display, and was tried on an example case with single brain metastasis. The dose-volume histograms (DVH's) of the planning target volume (PTV) and the normal brain derived by the control plan were reciprocally compared with those derived by the plan using the same arc arrangement plus the independent collimator jaw closure. Results : When using 5.0 cm diameter collimator, the measurements of the OF's and the TMR's with one independent jaw set at 30 mm (unblocked), 15.5 mm, 8.6 mm, and 0 mm from th central beam axis showed good correlation to the theoretical calculation within 0.5% and 0.3% error range. The dose profiles at 5 cm depth obtained by the film dosimetry also showed very good correlation to the theoretical calculations. The isodose profiles obtained on the home-made software demonstrated a slightly more conformal dose distribution around the target lesion by using the independent jaw closure, where the DVH's of the PTV were almost equivalent on the two plans, while the DVH's for the normal brain showed that less volume of the normal brain receiving high radiation dose by using this modification than the control plan employing the circular collimator cone only. Conclusions : With the beam shaping modification using the independent jaw closure, authors have realized wider clinical application of SRT with more conformal dose planning. Authors believe that SRT, with beam shaping ideas and efforts, should no longer be limited to the small spherical lesions, but be more widely applied to rather irregularly shaped tumors in the intracranial and the head and neck regions.

  • PDF

Structure and function of the secretory ducts in Panax ginseng C.A. Mayer (인삼 분비관의 구조와 기능)

  • Kim, Woo-Kap;Kim, Eun-Soo
    • Applied Microscopy
    • /
    • v.10 no.1_2
    • /
    • pp.77-86
    • /
    • 1980
  • The distribution of the secretory ducts, fine structures of the secretory epithelial cells, and the ingredients of the metaplasmic inclusions were studied at light and electron microscopical levels in seeds, stems, leaves, and roots of ginseng. The secretory ducts occurred in the hypocotyl of the embryo, in the cortex of the roots, and also both inside and outside of each vascular bundle in the stems and leaves. Especially, it is considered that the circular layers of the secretory ducts in roots may represent their ages. The epithelial cell has well developed nucleolus, mitochondria and smooth endoplasmic reticulum. Sudanophyl and osmiophilic inclusions were found in the epithelial cytoplasm and duct lumen. But these inclusions were not observed when extracted with pyridin or alcohol. In contrast to the lumen with red color, the epithelial cells were blue in color as stained with nile blue, suggesting that the former inclusions are neutral lipid while the latter are acidic lipid. The electron density of the cell inclusions was quite high as fixed with osmium tetroxide, indicating that most of these secretory materials seem to be unsaturated lipid. Therefore, since ginseng secretory ducts are closely associated with the lipid metabolism, it should be called lipid canal or lipid duct.

  • PDF

AA Study of Spatial Composition and Area Distribution by Function in Public Health Centers of Busan (부산도시보건소의 기능별 공간구성 및 면적배분에 관한 연구)

  • Cho, Heeyoung;Yoon, Sohee;Kim, Suktae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.2
    • /
    • pp.55-65
    • /
    • 2015
  • Purpose: Korea is increasing in the demand for medical services due to rapid economic growth and population aging in modern society. Thus, the importance has been emphasized for the health promotion in the community and the publicity and substantiality of public health centers. However, the environment is insufficient, compared to required functions and developed services as a urban public health center. The purpose of this study is to analysis the plane type and area composition of public health centers in Busan and to identify the property of their spatial configuration Methods: Eight public health centers in Busan, were classified, which had been selected as a medical tourism city. Subsequently, space requirements were analyzed, facilities were typed, vertical, horizontal spaces were reviewed, and area ratios by business function were calculated. Results: A review of the property of spatial configuration and an analysis of the area ratio revealed the three findings. 1)The horizontal analysis found various types: a single type, a multi-type, a radial type, and a circular type, 2)The vertical analysis showed that since a care function (general practice), and a task function (maternal and child health) were concentrated in lower level spaces, the lobby and core were closed located for providing quick medical services. 3)The analysis of the area ratio in public health centers in terms of their function indicated that each public health center' programs had the greatest influence on the area. Implications: This study attempted to present spatial structural problems and improvements for city public health center by identifying their state and classify their functions and types and by calculating the ratio of their area configuration according to the spatial composition. It was thus aimed to presenting implications in establish public functions and roles by activating business through in connection with the number of municipalities in many ways, such as regional health. medical welfare, etc. to improve the health of local residents, and by providing differentiated programs in accordance with local characteristics.

A Commensal Thermophile, Symbiobacterium toebii: Distribution, Characterization, and Genome Analysis

  • Bae Jin-Woo;Kim Kwang;Song Jae Jun;Ha Jae Seok;Kim Joong-Jae;Kang Gwan-Tae;Kim Mi-Hwa;Hong Seung-Pyo;Sung Moon-Hee
    • Proceedings of the Microbiological Society of Korea Conference
    • /
    • 2001.11a
    • /
    • pp.46-53
    • /
    • 2001
  • A commensal thermophile, Symbiobacterium toebii, isolated from hay compost (toebii) in Korea commensally interacted with a thermophilic Geobacillus toebii sp. nov., which was a new species within the genus Geobacillus on the basis of the phenotypic traits and molecular systematic data. S. toebii required the crude extracts and/or culture supernatant of the Geobacillus toebii for axenic growth and could grow on the temperature between 45 and $70^{\circ}C$ (optimum: $60^{\circ}C$; 2.4 h doubling time) and pH 6.0 and 9.0 (optimum: pH 7.5). The G+C content of the genomic DNA was $65 mol\%$, and the major quinones were MK-6 and MK-7. A phylogenetic analysis of its 16S rDNA sequence indicated that Symbiobacterium toebii was closely related with solely reported Symbiobacterium thermophilum. The presence of the commensal thermophile 16S rDNA and accumulation of indole in all the enriched cultures indicate that Symbiobacterium toebii is widely distributed in the various soils. The genome of S. toebii constituted a circular chromosome of 3,280,275 base pairs and there was not an extra-chromosomal element (ECE). It contained about 4,107 predicted coding sequences. Of these protein coding genes, about $45.6\%$ was encoded well-known proteins and annotated the functional assignment of 1,874 open reading frames (ORFs), and the rest predicted to have unknown functions. The genes encoding thermostable tyrosine phenol-lyase and tryptophan indole-lyase were cloned from the genomic DNA of S. toebii and the enzymatic production of L-tyrosine and L-tryptophan was carried out with two thermostable enzymes overexpressed in recombinant E. coli.

  • PDF

Effect of the Concentration of Cobalt Chloride Solution for the Preparation of Nano-Sized Cobalt Oxide Powder by Spray Pyrolysis Process

  • Yu, Jae Keun;Cha, Kwang Yong;Seo, Dong Jun;Han, Joung Su;Jang, Jae Bum;Lee, Yong Hwa;Kim, Dong Hee
    • Korean Journal of Materials Research
    • /
    • v.24 no.6
    • /
    • pp.277-284
    • /
    • 2014
  • Using the spray pyrolysis process, nano-sized cobalt oxide powder with average particle size below 50 nm was prepared from cobalt chloride solution. The influences of the raw material solution on the properties of the powder formed examined. When the concentration of Co was low(20 g/L), the average particle size of the powder formed was roughly 20 nm, and the cohesion between these particles was significantly strong. When the concentration of Co increased to 100 g/L, the droplets nearly failed to exist in circular form and reflected a severely divided form. Furthermore, the average size of the particles formed was roughly 40 nm, and the particles reflected a polygonal form. When the solution was increased to nearly saturation level (Co at 200 g/L), the particle size distribution reflected significant unevenness due to severe droplet division while the surface also reflected significant unevenness. Furthermore, the average size of the particles formed increased significantly to 70 nm. The results of XRD analysis showed that the strength of the peaks reflected very little change when the concentration of Co was increased from 20 g/L to 50 g/L. Alternatively, when the concentration was increased to 100 g/L, the strength of the peaks increased compared to when the concentration was 50 g/L. However, when the concentration was increased to 200 g/L, the strength of the peaks failed to reflect significant change compared to when the concentration was 100 g/L. The specific surface area dramatically decreased by 30 % when the concentration of Co was increased from 20 g/L to 50 g/L. Alternatively, when the concentration of Co the solution increased to 100 g/L, the specific surface area decreased by roughly 15 %. Furthermore, when the concentration of Co was increased to nearly saturation level(200 g/L), the specific surface area decreased by roughly 35%.

Methodologic Aspect of LINAC-based Stereotactic Radiosurgery (선형가속기 기반 뇌정위 방사선 수술기법)

  • Choi, Tae Jin
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.127-137
    • /
    • 2012
  • A conversing beam is firstly designed for radiosurgery by a neurosugern Lars Leksell in 1949 with orthogonal x-rays tube moving through horizontal moving arc to focusing the beam at target center. After 2 decades he composits 201 source of the Co-60 for gamma knife which beams focused at locus. Sveral linac-based stereotactic radiosurgery using the circular collimated beam which size range for 0.4~4.0 cm in a diameter by non-coplanar multiarc have been developed over the decades. The irregular lesions can be treated by superimposing with several spherical shots of radiation over the tumour volume. Linac based techniques include the use of between 4 and 11 non-co-planar arcs and a dynamic rotation technique and use photon beam energies in the range of 6~10 MV. Reviews of the characteristics of several treatment techniques can be found in the literature (Podgorsak 1989, Schell 1991). More in recent, static conformal beams defined by custom shaped collimators or a mini- or micro-multileaf collimator (mMLC) have been used in SRS. Finally, in the last few years, intensity-modulated mMLC SRS has also been introduced. Today, many commercial and in-house SRS programs have also introduced non-invasive immobilization systems include the cyberknife and tomotherapy and proton beam. This document will be compared the characteristics of dose distribution of radiosurgery as introduced gamma knife, BrainLab include photon knife in-house SRS program and cyberknife in currently wide used for a cranial SRS.

A numerical study on pull-out behaviour of cavern-type rock anchorages (수치해석에 의한 암반상의 지중정착식 앵커리지 인발 거동 연구)

  • Hong, Eun-Soo;Cho, Gye-Chun;Baak, Seng Hyoung;Park, Jae-Hyun;Chung, Moonkyung;Lee, Seong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.6
    • /
    • pp.521-531
    • /
    • 2014
  • This paper is a study for behaviour of cavern type anchorage tunnels for suspension bridges with cable tension. Anchorage behaviour, design method for anchorage, and failure surface angle, ${\delta}$ are analyzed by comparing numerical analysis results and ultimate pullout capacities($P_u$) using bilinear corelation equation. Results show that design depths for cavern type anchorage tunnels are easily checked with linear relationships for $P/{\gamma}/H$ vs. displacement and $P_u/{\gamma}/H$ vs. H/b. The analysis results of maximum shear strain distribution and plastic status show that failure shapes are closer to circular arc model than soil cone model which frequently used. To an easy calculation of the ultimate pullout capacity, we propose a simple bilinear failure model in this study. The calculated ultimate pullout capacities from the proposed bilinear corelation equation using two failure angles results are similar to the ultimate pullout capacities from numerical analysis.

Effect of High Dose ${\gamma}-irradiation$ on the Physicochemical Properties of Shell Eggs during Storage (고선량 감마선 조사가 신선란의 저장 중 이화학적 특성에 미치는 영향)

  • Moon, Sun-Ae;Song, Kyung-Bin
    • Applied Biological Chemistry
    • /
    • v.43 no.4
    • /
    • pp.260-265
    • /
    • 2000
  • To determine the quality change of the irradiated eggs during storage, fresh shell eggs were irradiated using $^{60}Co$ at 0, 1, 5, 10, 30 kGy and stored for 30 days. The york index, color, pH, viscosity, egg weight, and SDS-PAGE profile of the irradiated eggs were examined. During storage, york index values of the irradiated eggs and the control were decreased and the increase of dose decreased yolk index. However, the yolk index values were increased temporarily at 10 kGy and 30 kGy. The yolk color had a bright yellow with increases in dose level and there was no significant change during storage. The albumen viscosities were decreased with increases in dosage and were decreased during storage. Also, the albumen pH values of the irradiated eggs were higher than that of the control and were increased during storage. The weight losses of eggs were increased during storage and there were no significant changes by dose level. SDS-PAGE profile of the egg white proteins of the shell eggs showed the change in molecular weight distribution and had aggregation pattern as well as degradation. CD and fluorescence spectroscopy study showed changes in the secondary and tertiary structure of egg white proteins by ${\gamma}-irradiation$. Therefore, this study clearly indicates that irradiation dose of eggs should be appropriate to prevent the loss of egg qualities.

  • PDF