• Title/Summary/Keyword: circular concrete column

Search Result 218, Processing Time 0.024 seconds

Evaluation of Shear Capacity Curve Model for Seismic Design (내진설계를 위한 전단성능곡선 모델의 평가)

  • Ko, Seong-Hyun;Lee, Jae-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.186-189
    • /
    • 2006
  • Since the columns with flexure-shear failure have lower ductility than those with flexural failure, shear capacity curve models shall be applied as well as flexural capacity curve in order to determine ultimate displacement for seismic design or performance evaluation. In this paper, a proposed modified shear capacity curve model is compared with the other models such as the CALTRANS model, Aschheim et al.'s model, and Priestley et al.'s model. Four shear capacity curve models are applied to the 4 full scale and 7 small scale circular bridge column test results and the accuracy of each model is discussed. It may not be fully adequate to drive a final decision from the application to the limited number of test results, however the proposed model provides the better prediction of failure mode and ultimate displacement than the other models for the selected column test results.

  • PDF

Tubular composite beam-columns of annular cross-sections and their design practice

  • Kvedaras, A.K.;Kudzys, A.
    • Steel and Composite Structures
    • /
    • v.10 no.2
    • /
    • pp.109-128
    • /
    • 2010
  • The expediency of using tubular composite steel and concrete columns of annular cross-sections in construction is discussed. The new type space framework with tubular composite columns of multi-storey buildings and its rigid beam-column joints are demonstrated. The features of interaction between the circular steel tube and spun concrete stress-strain states during the concentrical and eccentrical loading of tubular composite members are considered. The modeling of the bearing capacity of beam-columns of composite annular cross-sections is based on the concepts of bending with a concentrical force and compression with a bending moment. The comparison of modeling results for the composite cross-sections of beam-columns is analysed. The expediency of using these concepts for the limit state verification of beam-columns in the methods of the partial safety factors design (PSFD) legitimated in Europe and the load and resistance factors design (LRFD) used in other countries is presented and illustrated by a numerical example.

Stress Distribution Behavior Hollow and Felled Circular Column Column-Box Beam Connections (비충전 및 충전 원형기둥-상자형보 접합부의 응력분포특성)

  • Hwang, Won Sup;Park, Yong Myung;Choi, Won Kyong;Kim, Young Pil
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.3
    • /
    • pp.433-441
    • /
    • 2002
  • This study present the stressdistribution of circular column-box beam connection in steel piers. Experiments were carried out for hollow and concrete filled connections, depending on the joint angle. To determine vertical and shear stress distribution, this study examined the equivalent web depth dc' that is mainly used in existing design equation. Lidewise, as additional equivalent web depth was introduced. Stress values that were calculated using equivalent wev depth were also compared with the test stress value. Results showed that stresses of hollow and filled connections have great differences. However, dc' has a limitation for some joint angles. Likewise, stress of filled connection was less than that of the hollow connection. The test value of filled connection was also compared with design equations that were introduced from the hollow connection.

Experimental Behavior of Reinforced Concrete Column-Bent Piers under Bidirectional Repeated Loading (이축반복하중을 받는 2주형 철근콘크리트 교각의 실험거동)

  • Park, Chang-Kyu;Lee, Beom-Gi;Song, Hee-Won;Chung, Young-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.17-24
    • /
    • 2005
  • Response of reinforced concrete (RC) column-bent piers subjected to bidirectional seismic loadings was experimentally investigated. RC column-bent piers represent one of the most popular shapes of piers used in Korea highway bridges. Four column-bent piers were constructed in 400 mm diameter and 2,000 mm height. Each pier has two circular supporting columns. These piers were tested under bidirectional lateral load reversals with an axial load of $0.1f_{ck}A_g$. The test parameters included : different transverse reinforcement contents and lap-spliced longitudinal reinforcing steels. Test results indicate that the lap splice of longitudinal reinforcing steels have significantly influenced on hysteretic response of column-bent piers similar to previous test results for single columns with corresponding test parameters. Column capacity was changed with the level of transverse confinement. From the comparison of test result for single column under unidirectional loading, the damage of single column was concentrated on lower plastic hinge region but the damage of column-bent piers was scattered to upper and lower plastic hinge region.

Experimental study on reinforced high-strength concrete short columns confined with AFRP sheets

  • Wu, Han-Liang;Wang, Yuan-Feng
    • Steel and Composite Structures
    • /
    • v.10 no.6
    • /
    • pp.501-516
    • /
    • 2010
  • This paper is aiming to study the performances of reinforced high-strength concrete (HSC) short columns confined with aramid fibre-reinforced polymer (AFRP) sheets. An experimental program, which involved 45 confined columns and nine unconfined columns, was carried out in this study. All the columns were circular in cross section and tested under axial compressive load. The considered parameters included the concrete strength, amount of AFRP layers, and ratio of hoop reinforcements. Based on the experimental results, a prediction model for the axial stress-strain curves of the confined columns was proposed. It was observed from the experiment that there was a great increment in the compressive strength of the columns when the amount of AFRP layers increases, similar as the ultimate strain. However, these increments were reduced as the concrete strength increasing. Comparisons with other existing prediction models present that the proposed model can provide more accurate predictions.

Experimental study on reinforced concrete filled circular steel tubular columns

  • Hua, Wei;Wang, Hai-Jun;Hasegawa, Akira
    • Steel and Composite Structures
    • /
    • v.17 no.4
    • /
    • pp.517-533
    • /
    • 2014
  • Experimental results of 39 specimens including concrete columns, RC columns, hollow steel tube columns, concrete filled steel tubular (CFT) columns, and reinforced concrete filled steel tubular (RCFT) columns are presented. Based on the experimental results, the load-carrying capacity, confined effect, ductility, and failure mode of test columns are investigated. The effects of the main factors such as width-thickness ratio (the ratio of external diameter and wall thickness for steel tubes), concrete strength, steel tube with or without rib, and arrangement of reinforcing bars on the mechanical characteristics of columns are discussed as well. The differences between CFT and RCFT are compared. As a result, it is thought that strength, rigidity and ductility of RCFT are improved; especially strength and ductility are improved after the peak of load-displacement curve.

A stress-strain Model of High-strength concrete confined with Transverse Reinforcement (횡보강철근으로 구속된 고강도 콘크리트의 응력-변형률 구속 모델)

  • Moon, Cho-Hwa;Park, Jong-Wook;Kim, Sang-Woo;Kim, Kil-Hee;Lee, Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.87-88
    • /
    • 2010
  • The strength and ductile capacity of reinforced concrete column can be improved by confinement using transverse reinforcement. Variety stress-strain models about the reinforced concrete confined by transverse reinforcement has been proposed. In this paper, parameters which effect to the ultimate confinement stress of circular cylinder confined by high strength transverse steel is examined. And the possion's ratio equation is proposed by analysis of strain between concrete and transverse reinforcement.

  • PDF

Structural response of rectangular composite columns under vertical and lateral loads

  • Sevim, Baris
    • Steel and Composite Structures
    • /
    • v.25 no.3
    • /
    • pp.287-298
    • /
    • 2017
  • The present study aims to determine the structural response of full scaled rectangular columns under both of vertical and lateral loads using numerical methods. In the study, the composite columns considering full concrete filled circular steel tube (FCFRST) and concrete filled double-skin rectangular steel tube (CFDSRST) section types are numerically modelled using ANSYS software. Vertical and lateral loads are applied to models to assess the structural response of the composite elements. Also similar investigations are done for reinforced concrete rectangular (RCR) columns to compare the results with those of composite elements. The analyses of the systems are statically performed for both linear and nonlinear materials. In linear static analyses, both of vertical and lateral loads are applied to models as only one step. However in nonlinear analyses, while vertical loads are applied to model as only one step, lateral loads are applied to systems as step by step. The displacement and stress changes in some critical nodes and sections and contour diagrams are reported by graphs and figures. At the end of the study, it is demonstrated that the nonlinear models reveal more accurate result then those of linear models. Also, it is highlighted that composite columns provide more and more safety, ductility compared to reinforced concrete column.

Assessment of Ductility for the RC Piers with Transverse Reinforcement and Application of Carbon-Fiber Red (횡방향 구속철근의 배근방법에 따른 철근콘크리트 교각의 연성 평가 및 탄소섬유 ROD의 적용)

  • 이영호;이학은
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.1
    • /
    • pp.8-15
    • /
    • 2002
  • This paper presents a study carried out for the seismic capacity in reinforced concrete(RC) piers by the confinement effect of transverse reinforcement as such a hooked-tied, welded-tied and spiral reinforcement. In order to assess the seismic capacity with transverse reinforcement, experiment리 and analytical methods were adopted. A RC column survey was conducted based on eight one-fourth scale single circular column specimens designed and tested under slow horizontal cyclic loads. Two cases were analyzed. The confinement effect of concrete by transverse reinforcement is considered not in Case 1 but in Case 2. Also, we studied the propriety of making use of the method in which a carbon fiber rod replace spiral reinforcement in RC piers. In experimental tests, a welded-tied and spiral reinforcement has a good seismic capacity, but a carbon fiber rod presents low ductility in comparison with a hooked-tied reinforcement. In an analytical study, displacement ductility is approximate to the experimental result because of considering the confinement effect of the transverse reinforcement. Even if the confinement effect of the transverse reinforcement is considered, the analytical results for ductility of the specimens with welded-tied and spiral reinforcement show an excessive underestimation of the experimental results.

Comparative Study of Design Codes on the Transverse Steel Amount of Circular Reinfored Concrete Columns (철근콘크리트 원형단면교각의 횡방향철근량에 관한 설계비교)

  • 배성용;곽동일;김희덕
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.1
    • /
    • pp.98-103
    • /
    • 2001
  • This paper is conducted to compare the seismic design standard of a bridge column such as the Korean Bridge Design Standard(KBDS), EC 8, NZS 3101 and ATC 32. The KBDS adopted the seismic design requirements in 1992. The earthquake magnitude in Korea is compared with those in the west coast of the USA. It may be said that the current seismic design requirements of the KBDS provides design results, that are too conservative especially for transverse reinforcement details and amounts in reinforced concrete columns. This fact usually creates construction problems in concrete casting, due to congestion of transverse reinforcement. Furthermore, the effective stiffness; $I_{eff}$ depends on both the axial load P/$A_gF_{ck}$ and the longitudinal reinforcement ratio $A_{st}/A_g, so it is the conservative to use the effective stiffness I$_{eff}$ than the gross section stiffness Ig. Seismic design for the transverse reinforcement content of the concrete column was analyzed and considered to have an extreme-fiber compression strain, response modification factor, axial load and effective stiffness etc.c.

  • PDF