• 제목/요약/키워드: circuit stability

검색결과 544건 처리시간 0.027초

고성능 풀 스윙 BiCMOS 논리회로의 설계 (Design of High Performance Full-Swing BiCMOS Logic Circuit)

  • 박종열;한석붕
    • 전자공학회논문지B
    • /
    • 제30B권11호
    • /
    • pp.1-10
    • /
    • 1993
  • This paper proposes a High Performance Full-Swing BiCMOS (HiF-BiCMOS) circuit which improves on the conventional BiCMOS circuit. The HiF-BiCMOS circuit has all the merits of the conventional BiCMOS circuit and can realize full-swing logic operation. Especially, the speed of full-swing logic operation is much faster than that of conventional full-swing BiCMOS circuit. And the number of transistors added in the HiF-BiCMOS for full-swing logic operation is constant regardless of the number of logic gate inputs. The HiF-BiCMOS circui has high stability to variation of environment factors such as temperature. Also, it has a preamorphized Si layer was changed into the perfect crystal Si after the RTA. Remarkable scalability for power supply voltage according to the development of VLSI technology. The power dissipation of HiF-BiCMOS is very small and hardly increases about a large fanout. Though the Spice simulation, the validity of the proposed circuit design is proved.

  • PDF

APD용 TIA 회로의 안정성 개선을 위한 Quenching 저항 영향 분석 (Analysis of Quenching Resistor Effect to Improve Stability of TIA Circuit for APD)

  • 기동한;진유린;김성미;조성익
    • 전기전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.373-379
    • /
    • 2022
  • LTV(Light to Voltage) 변환을 위한 APD(Avalanche Photo Diode)는 다른 PD(Photo Diode)와 다르게 높은전압의 동작영역을 사용하므로 TIA(Transimpedance Amplifier) 사용시 과전류 방지를 위해 Quenching 저항을 직렬로 연결하여야 한다. 그러한 경우 Quenching 저항이 TIA 전달함수에 영향을 미쳐 안정도에 심각한 결과를 초래할 수 있다. 본 논문에서는 APD Quenching 저항이 TIA의 전압과 전류 루프 전달함수에 미치는 영향을 분석하여 안정도 개선을 위한 Quenching 저항 값 결정 방법을 제안하고자 한다. 제안된 방법에 의하여 Quenching 저항을 가지는 TIA 회로를 설계하여 시뮬레이션 및 칩 제작을 통하여 동작의 안정도를 검증하였다.

Influence of Physical Load on the Stability of Organic Solar Cells with Polymer : Fullerene Bulk Heterojunction Nanolayers

  • Lee, Sooyong;Kim, Hwajeong;Kim, Youngkyoo
    • Current Photovoltaic Research
    • /
    • 제4권2호
    • /
    • pp.48-53
    • /
    • 2016
  • We report the effect of physical load on the stability of organic solar cells under physical loads. The active layers in organic solar cells were fabricated with bulk heterojunction films (BHJ) films of poly (3-hexylthiophene) and phenyl-$C_{61}$-butyric methyl ester. The loading time was varied up to 60 s by keeping the physical load constant. Results showed that the open circuit voltage was not influenced by the physical load but other solar cell parameters were sensitive to the loading time. The fill factor was very slightly increased at 15 s, while short circuit current density was well kept for 30 s. The power conversion efficiency was reasonably maintained for 45 s but became significantly decreased by the continuous loading for 60 s.

제주계통에서 동기조상기 기동에 따른 전압안정도 영향 검토 (Analysis of Impact on Voltage Stability by Starting Synchronous Condenser in Jeju AC Network)

  • 최순호;이성두;김찬기
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.23-28
    • /
    • 2015
  • Two old synchronous condensers in Jeju are being replaced by new machines to operate Jeju AC network with Haenam-Jeju HVDC system stably. Before new synchronous condensers operate on site, voltage stability analysis is conducted to verify stable operation of jeju AC network. Through impedance analysis of the synchronous machine, transformer and ac network, the equivalent circuit is constructed and the voltage drop during start-up is calculated. Then, PSS/E fault analysis is performed to acquire short-circuit capacity according to the generator operation scenarios. Voltage variation when starting synchronous condenser is simulated in PSCAD/EMTDC and satisfies the operating condition of jeju AC network and HVDC #1 system.

광대역 항재밍 소형 GPS 안테나용 비 포스터 정합회로 (Non-Foster Matching Circuit for Wideband Anti-Jamming Small GPS Antennas)

  • 하상규;정경영
    • 한국전자파학회논문지
    • /
    • 제27권12호
    • /
    • pp.1112-1115
    • /
    • 2016
  • 위성항법시스템은 민간 및 군수 분야에서 널리 사용되고 있는 유용한 시스템이다. 그러나 지구 상공 2만 km 이상 원거리 송신 신호로 인한 수신 감도 미약으로, 위성항법시스템의 신호는 항재밍 공격에 취약하다. 본 논문에서는 항재밍 소형 GPS 배열안테나 설계를 위한 선행 연구로 전기적으로 초소형인 GPS 안테나 소자를 효율적으로 정합하는 비 포스터 정합회로에 대한 연구를 수행하였다. 전기적으로 소형인 GPS 안테나는 높은 품질계수로 인해 방사 이득이 낮고, 광대역 정합이 어렵다. 이를 해결하기 위해 소형 GPS 안테나용 비 포스터 정합회로(non-Foster matching circuit)를 설계하였다. Linvill의 교차 결합쌍 트랜지스터로 구성된 네거티브 임피던스 변환기 회로를 제작하였으며, 시간 영역에서 안정도 검증을 통해 안정성을 확인하였다. 비 포스터 정합회로를 이용한 소형 GPS 안테나 무반사실 측정결과, 전면방향이득이 17 dB 이상 개선됨을 확인하였다.

스위칭 레귤레이터의 안전성과 이득대역폭적과의 관계 (The Relationship Between Stability and Gain Band-width Product in the Switching Regulator)

  • 김희준;이인환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.399-402
    • /
    • 1988
  • In this paper, the relationship between stability and gain band-width product (GB) is clear ed by evaluating the feedback gain in the buck-boost switching regulator. Especially, considering the effect of the right-half-plane pole on the stability, we found available region of GB on the stability with the one pole compensation for the feedback circuit.

  • PDF

DC - DC콘버어터의 소형화와 안정성 (A Miniturization and Stability of DC-to-DC Converters)

  • Kim, Hee-Jun
    • 대한전기학회논문지
    • /
    • 제37권8호
    • /
    • pp.528-533
    • /
    • 1988
  • The miniturization of a DC-to-DC converter in connection with the stability is investigated in this paper. As both the capacitance of the smoothing capacitor and the inductance of the reactor are reduced by rasing the switching frequency, it is known that the stability of the buck converter declines with the switching frequency but the buck-boost converter has a nearly uniform stability. Furthermore, that the buck-boost converter is suitable for the miniturization of circuit is cleared in the high frequency region above a certain switching frequency.

  • PDF

Dual band Antenna Switch Module의 LTCC 공정변수에 따른 안정성 및 특성 개선에 관한 연구 (Improving Stability and Characteristic of Circuit and Structure with the Ceramic Process Variable of Dualband Antenna Switch Module)

  • 이중근;유찬세;유명재;이우성
    • 마이크로전자및패키징학회지
    • /
    • 제12권2호
    • /
    • pp.105-109
    • /
    • 2005
  • 본 논문은 LTCC 공정에 기반을 둔 GSM/DCS dual band 의 소형화된 antenna switch module을 공정변수 따른 특성의 왜곡을 안정화시키는 연구를 수행하였다. 특히 tape thickness의 변화에 따라 패턴간의 기생 커플링이 주된 변수로 작용한다. 두께 50um인 tape으로 제작된 시편의 사이즈는 $4.5{\times}3.2{\times}0.8 mm^3$이고 insertion loss는 Rx mode와 Tx mode 각각 ldB. 1.2dB 이하이다. 공정상에서 tape thickness의 변화에 따라 개발된 모듈의 특성 안정성을 검증하기 위해 각 블록-다이플렉서,필터, 바이어스 회로-을 probing method을 이용, 측정하였고, 각 블록간의 상호관계는 VSWR을 계산하여 비교하였다. 또한 회로적 관점에서 특성 개선을 위해 바이어스 회로부분의 집중소자형과 분포소자형을 구현하여 서로 비교 분석하였다. 이를 통해 각 블록의 측정과 계산된 VSWR의 데이터는 공정변수에 의해 변화된 전체 module의 특성과 안정성 거동을 파악하는데 좋은 정보를 준다. Tape thickness변화에도 불구하고 다이플렉스의 matching값은 연결되는 바이어스 회로와 LPF의 matching값과 상대 matching이 되면서, 낮은 VSWR을 유지하여 전체 insertion loss가 안정화되는 것을 확인하였다. 더불어 분포소자형 바이어스 회로보다는 집중소자형이 다른 회로블럭과의 관계에서 더 좋은 매칭을 이루어 loss개선에 일조하였다. Tape thickness가 6 um이상의 변화를 가져와도 집중소자형 바이어스 회로는 낮은 손실을 유지하여 더 넓은 안정 범위를 가져오기 때문에 양산에 적합한 구조가 될 수 있다 그리고, probing method에 의한 안정성 특성 추출은 세라믹에 임베디드된 수동회로들의 개발에 충분히 적용될 수 있다.

  • PDF

1차 지연회로를 사용한 ZVS Full-Bridge 컨버터 구동회로 설계 (The Driving Circuit Design for ZVS Full-Bridge Converter with 1st Order Delay Circuit)

  • 조내수;최연호;윤경섭;구본호;권우현
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.569-574
    • /
    • 2010
  • The full bridge converter have been used for high power system that is needed to switch the big current. So, EMI and stability problem is occurred. The Soft switching method is the solution to solve the above problem, But implementation of soft switching(ZVS: Zero Voltage Switching) is so complicate and expensive because of the DSP MCU and shift circuit. In this paper, we introduce the technical method for driving circuit of ZVS full bridge converter with 1st order delay circuit and logic elements. The realization of this method is so simple and cheap. The effectiveness of the proposed circuit is verified by experimental results.

유압유의 동점도와 부하변화에 따른 압력의 영향 (The Effects of Dynamic Viscosity and Load od Hydraulic Oil on Pressures)

  • 박주석;김일수;손준식;안영호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.573-576
    • /
    • 1995
  • The realization by many industrial countries that manufacturing is a critical ingredient for attaining economic strength and stability has led to the development of automated systems which were proviously considered as gimmicks. The adaptive skill of the human operator is now being simulated and reproduced by computer that have become more powerful and less expensive. The work presented in this paper forms an investigation of the effects of dynamic viscosity and load of hydraulic oil an pressures with three different circuit(meter-in, meter-out and bleed off). The experimental results showed that pressures increase with an increase in dynamic viscosity and load in bleed off circuit, but there is no variation of pressure in meter-In meter-out circuit.

  • PDF