• Title/Summary/Keyword: circuit analysis

Search Result 3,947, Processing Time 0.027 seconds

Dynamic Model and Analysis of a Vacuum Circuit Breaker Mechanism for High-Speed Closing and Opening Simulations (고속 개폐 시뮬레이션을 위한 진공 회로차단기의 동적 모델 및 해석)

  • An, Gil-Yeong;Kim, Su-Hyeon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.10
    • /
    • pp.163-170
    • /
    • 2002
  • The dynamic model of a high-speed vacuum circuit breaker mechanism with spring-actuated cam and linkage is derived to simulate the high-speed closing and opening operations. Its validation for an analysis of high-speed motion behavior is checked through experiments. The characteristics of the friction on the camshaft are investigated using the nonlinear pendulum experiment. The parameters of the friction model are estimated using the optimization technique. The analysis exhibits that the friction of the pendulum depends on stick-slip, Stribeck effect and viscous damping. Comparing simulation results with actual responses using a high-speed camera, the appropriateness of derived dynamic models for the rapid closing and opening operations is shown. The spring motion, which has much influence on the closing responses, is observed.

Design and Analysis with the magnetic shape coefficients of Linear Homopolar Synchronous Motor for vehicles (자기부상/추진 일체형 차량용 LHSM의 자기형상계수를 고려한 설계와 특성해석)

  • Jang, S.M.;Jeong, S.S.;Lee, S.H.;Seo, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.22-24
    • /
    • 1997
  • The 4-pole LHSM was composed of the figure-of-eight shaped 3-phase armature windings. DC field windings, and the segmented secondary with the transverse bar track. The motor was designed on the base of the performance characteristic equations and the equivalent circuit model, with the coefficients of the magnetic shape. These coefficients were computed from the analytical expressions and examined from FEM analysis. The magnetic equivalent circuit of 3-D model of LHSM was obtained. and this concept provided the equivalent models for 2-D FEM analysis. Therefore, the airgap field, the lift and thrust force were calculated and compared with the results of magnetic equivalent circuit method.

  • PDF

Comparison Analysis of Induction Motor using the Equivalent Circuit (등가회로도를 이용한 유도전동기의 특성 비교 분석)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.1
    • /
    • pp.7-11
    • /
    • 2014
  • Induction motor is the most widely used to obtain the driving force in the industrial site. Induction motor is generally applied to the constant speed operation. Induction motor generates a high current at startup. So analysis for both steady state operation and start-up transient is required. In most cases, an equivalent circuit is used for the characteristics analysis of the induction motor. In this study, the two programs are applied to analyze for the rated speed as well as entire speed range. We confirmed that calculation results of the two programs are similar to each other.

A Study on the Instantaneous Characteristics Analysis Method of PMSM using Slot Equivalent Circuit (슬롯등가회로를 이용한 영구자석모터의 순시치 해석법연구)

  • Won, Sung Hong;Han, Ki-Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Recently, many motor analysis methods have been developed and studied. Among these methods, the finite element method(FEM) and the analytic method are most popular in field engineers because of the accuracy of FEM and the convenience and rapid analysis time of the analytic method. Contrary, the finite element method has a weakness in calculation time and it is not easy to obtain the instantaneous characteristics value of motor with the analytic method. In this paper, the authors proposes a novel method for calculating the instantaneous characteristics of motors with the magnetic slot equivalent circuit.

Characteristics analysis of time sharing type high frequencyinverter using serial-parallel resonant (직.병렬공진을 이용한 시분할형고주파 인버터의 특성해석)

  • 조규판;이경호;노채균;배영호;심광렬
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.173-178
    • /
    • 2000
  • The time sharing type high frequency inverter using serial-parallel resonant to give VVVF function in the inverter used as power source of induction heating at high frequency is presented in this paper. This proposed inverter can reduce distribution of the switching current because of using the current of serial resonant circuit to the input current of the parallel one. The analysis of the proposed circuit is generally described by using the normalized parameters. Also, according to the calculated characteristics value, a method of the circuit design and operating characteristics of the inverter is proposed. In addition, this paper proves the validity of theoretical analysis through Simulation. This proposed inverter show that it can be practically used in future as power source system for induction heating application, DC-DC converter etc.

  • PDF

Analysis of SLF Interruption Performance of Self-Blast Circuit Breaker by Means of CFD Calculation

  • Kim, Hong-Kyu;Chong, Jin-Kyo;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.254-258
    • /
    • 2014
  • This paper presents the performance analysis results of a short line fault interruption of a gas circuit breaker, particularly a self-blast type breaker. Hot gas flow analysis was carried out using a CFD calculation combined with the arc model and nozzle ablation model. To evaluate the interruption performance, the index function was defined using the pressure in the heating chamber and the density above the arc region. The simulation and test results showed that the gas flow field and suitable choice of an interruption performance index can be used to predict the interruption characteristics and provide guidelines for designing self-blast breakers with a higher interruption capability.

Analysis of Operating Characteristics of PM-Type Magnetic Circuit Breaker

  • Jun, Hee-Deuk;Woo, Kyung-Il;Kwon, Byung-Il
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.3B no.2
    • /
    • pp.74-78
    • /
    • 2003
  • This paper describes the operating characteristic analysis of the PM-type linear oscillatory actuator used as a magnetic circuit breaker for the electromagnetic field, electric circuit, and mechanical motion problems. Transient calculations are based upon a 2D finite element magnetic field solution including non-linearity of materials. Changes of the dynamic characteristics from the eddy current in the plunger are quantified from finite element analysis. A new laminated model is proposed to decrease the eddy current effect.

Magnetic Excitation Force of a Surface-mounted Permanent Magnet Motor due to Pole/Slot combination (SPM 모터의 극과 슬롯수 변화에 따른 전자기 가진력 특성 연구)

  • Song, Jeongyong;Kim, Doyeon;Jang, Gunhee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.321-326
    • /
    • 2013
  • This paper investigates the magnetic excitation force of a surface-mounted permanent magnet (SPM) motor according to the change of pole/slot combination. The characteristics of magnetic flux and radial magnetic force (RMF) due to pole/slot combination were analyzed by using magnetic circuit analysis. Also, the RMF of motors with the variable pole/slot combination was numerically simulated by using the finite element analysis to verify the result of the magnetic circuit analysis. This research shows that RMF ripple is reduced when the number of pole is smaller than the number of slot.

  • PDF

Transient Voltage Analysis of Low-Voltage Source Circuit inn Thermal Power Plant due to Grounding Potential Rise by Lightening (낙뢰침입에 의한 대지전위상승이 발전소 저압전원회로에 미치는 과전압 해석)

  • Yang, Byeong-Mo;Jeong, Jae-Kee;Min, Byeong-Wook;Lee, Jong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1644-1646
    • /
    • 1998
  • High-Smokestacks have been the symbol of the thermal power plant. Those cause the thermal power plant to be damaged by lightening for reaching several hundreds meter. In this paper, we investigated the accident of low-voltage source circuit due to grounding potential rise by lightening via high-smokestack in practically driving power plant, described examination into the cause and the impulse analysis. We analysed the transient voltage by EMTP(ElectroMagnetic Transient Program) via modeling the grounding system of power plant. This theoretical results coincided with practical accidental state. Therefore, it was verified that we could apply the grounding system of power plant and substation with the distribution-circuit analysis(EMTP).

  • PDF

Performance analysis and Design of self-excited Induction Generators considering output voltage (출력 특성을 고려한 단상 자기여자 유도 발전기의 특성 해석)

  • Kim, Cherl-Jin;Lee, Kwan-Yong;Cho, Young-Rae;Baek, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.76-79
    • /
    • 2005
  • This paper describes the performance analysis and design of 1-phase self-excited induction generators. The minimum parallel capacitance of self-excited capacitor connected auxiliary winding and the series capacitance of regulating voltage capacitor connected main winding is proposed the suitable value using circuit equations of main and auxiliary winding. For the steady state analysis, the equivalent circuit of 1-phase induction generators is used as circuit modeling using the double-revolving field theory. The validity of designed generator system will be confirmed by experimental and computed results.

  • PDF